Lin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lin Zhang has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Shi Bu
Changzhou University School of Mechanical Engineering and Rail Transit No. 21, Gehu Road, Wujin District, Changzhou, Jiangsu 213164 , China
7 shared publicationsWeigang Xu
7 shared publicationsChen Xu
Changzhou Zhongyuan Engineering Technology Co., Ltd, Changzhou, China
3 shared publicationsChengcheng Shi
3 shared publicationsChengman Zhou
Changzhou Univ, Sch Mech Engn & Rail Transit, Changzhou 213164, Peoples R China
3 shared publicationsFang Xu
Changzhou Univ, Sch Mech Engn & Rail Transit, Changzhou 213164, Peoples R China
3 shared publications
Latest Publications
- Open Access
Deposition Distribution and Thermal Resistance Analysis of Fins in Heat Exchangers
The deposition of fly ash on the heat exchanger will reduce the heat transfer efficiency of the system. This article conducted experiments and simulations on the deposition, exploring the effects of velocity, particle size on the deposition position. In addition, deposition density distribution was demonstrated, the calculation method of fin thermal resistance was improved, and the efficiency of fins was also calculated. The results showed that deposition decreased with velocity increasing, and the simulation results were in good agreement with the experimental results. The deposition distribution of the first section of the fin is unimodal, and the maximum deposition value approaches the peak of the fin. The distribution of the second section of the fin becomes bimodal with increasing velocity. In addition, as the speed increases, due to the decrease in deposition mass, the thermal resistance decreases by 53.2% and the fin efficiency increases by 8.82%.
Open AccessDeposition Distribution and Thermal Resistance Analysis of Fins in Heat Exchangers
The deposition of fly ash on the heat exchanger will reduce the heat transfer efficiency of the system. This article conducted experiments and simulations on the deposition, exploring the effects of velocity, particle size on the deposition position. In addition, deposition density distribution was demonstrated, the calculation method of fin thermal resistance was improved, and the efficiency of fins was also calculated. The results showed that deposition decreased with velocity increasing, and the simulation results were in good agreement with the experimental results. The deposition distribution of the first section of the fin is unimodal, and the maximum deposition value approaches the peak of the fin. The distribution of the second section of the fin becomes bimodal with increasing velocity. In addition, as the speed increases, due to the decrease in deposition mass, the thermal resistance decreases by 53.2% and the fin efficiency increases by 8.82%.
- 1 April 2024
- Published by Springer Nature in Aerosol Science and Engineering
- Vol. 8 (2) , 168-183
Numerical Study on the Flow Field Characteristics and Dust Removal Efficiency of Tubular Electrofiltration Equipment
- 1 April 2024
- Published by Springer Nature in Aerosol Science and Engineering
- Vol. 8 (2) , 168-183
Numerical Study on the Flow Field Characteristics and Dust Removal Efficiency of Tubular Electrofiltration Equipment
- 16 June 2023
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 196, 144-157
Thermodynamic properties of evaporative crystallization of high-salt wastewater
- 16 June 2023
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 196, 144-157
Thermodynamic properties of evaporative crystallization of high-salt wastewater
- 14 October 2022
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 15 (2) , 1-35
The Quantitative Study on the Influence of Operating Parameters Upon Thermal Performance of Heating Furnace
With the development of the social economy, people’s demand for energy is increasing. As a kind of high energy consumption equipment in petrochemical enterprises, the heating furnace is imperative to reduce its energy consumption. Therefore, in order to further improve the thermal efficiency of the heating furnace and reduce the emission of pollutants, this paper combines the actual operation of the SRT-III heating furnace in the chemical plant to establish a fluid domain model. The effects of different values of excess air coefficient, air preheating temperature, and oxygen concentration on the flow field characteristics and furnace thermal efficiency under two kinds of blackness were analyzed by numerical simulation. The results show that higher blackness has higher furnace thermal efficiency. Under the conditions of a balance between thermal efficiency and environmental protection performance, the optimal values of excess air coefficient, air preheating temperature, and oxygen concentration are 1.20, 473 K, and 25%, respectively.
- 14 October 2022
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 15 (2) , 1-35
The Quantitative Study on the Influence of Operating Parameters Upon Thermal Performance of Heating Furnace
With the development of the social economy, people’s demand for energy is increasing. As a kind of high energy consumption equipment in petrochemical enterprises, the heating furnace is imperative to reduce its energy consumption. Therefore, in order to further improve the thermal efficiency of the heating furnace and reduce the emission of pollutants, this paper combines the actual operation of the SRT-III heating furnace in the chemical plant to establish a fluid domain model. The effects of different values of excess air coefficient, air preheating temperature, and oxygen concentration on the flow field characteristics and furnace thermal efficiency under two kinds of blackness were analyzed by numerical simulation. The results show that higher blackness has higher furnace thermal efficiency. Under the conditions of a balance between thermal efficiency and environmental protection performance, the optimal values of excess air coefficient, air preheating temperature, and oxygen concentration are 1.20, 473 K, and 25%, respectively.
- 21 January 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (24) , 36208-36215
A microscopic and quantitative analysis on the separation of chloride ion by fly ash washing: Effect of liquid-to-solid ratio, washing time and temperature
In order to understand the removal characteristics of Cl− (chloride ion) in the fly ash from municipal solid waste incineration, so as to realize the harmless treatment of fly ash. The fly ash washing treatment experimental system was designed and built. The single factor experiments were used to explore the effect of liquid-to-solid ratio, washing time and temperature on the leaching rate of Cl− in the fly ash. The best experimental parameters of fly ash washing were obtained. At the same time, the microscopic morphology and crystal phase composition of fly ash before and after washing were explored. The results showed that the maximum removal rate of Cl− in the fly ash was 88.72% when the liquid-to-solid ratio was 8:1, the washing time was 5 min and the washing temperature was 70 ℃. It can be seen from the scanning electron microscope (SEM) image that most of the irregularly shaped square fly ash particles gradually transformed into regular spherical or elliptical shapes after washing. The X-ray diffractometer (XRD) results proved that the chlorine salt content in the fly ash after washing was significantly reduced, and the CaSO4•2(H2O), SiO2, CaCO3 and other substances were formed.
- 21 January 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (24) , 36208-36215
A microscopic and quantitative analysis on the separation of chloride ion by fly ash washing: Effect of liquid-to-solid ratio, washing time and temperature
In order to understand the removal characteristics of Cl− (chloride ion) in the fly ash from municipal solid waste incineration, so as to realize the harmless treatment of fly ash. The fly ash washing treatment experimental system was designed and built. The single factor experiments were used to explore the effect of liquid-to-solid ratio, washing time and temperature on the leaching rate of Cl− in the fly ash. The best experimental parameters of fly ash washing were obtained. At the same time, the microscopic morphology and crystal phase composition of fly ash before and after washing were explored. The results showed that the maximum removal rate of Cl− in the fly ash was 88.72% when the liquid-to-solid ratio was 8:1, the washing time was 5 min and the washing temperature was 70 ℃. It can be seen from the scanning electron microscope (SEM) image that most of the irregularly shaped square fly ash particles gradually transformed into regular spherical or elliptical shapes after washing. The X-ray diffractometer (XRD) results proved that the chlorine salt content in the fly ash after washing was significantly reduced, and the CaSO4•2(H2O), SiO2, CaCO3 and other substances were formed.
- 1 October 2021
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 154, 433-446
Water recovery efficiency improvement using the enhanced structure of the mist eliminator
- 1 October 2021
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 154, 433-446
Water recovery efficiency improvement using the enhanced structure of the mist eliminator
- 26 July 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 14 (3) , 1-34
Thermodynamic Investigation on the Performance of Closed Wet Cooling Tower
Closed wet cooling tower (CWCT) is an indirect-contact evaporative cooler, in which ambient air, spray water, and process water function together. In order to improve its thermal performance, a new heat transfer strategy is proposed. The influence of fan frequency, spray density, and processing water flow on the thermal performance of CWCT is obtained by combining theoretical and experimental research. By fitting the experimental data, the empirical formula of heat and mass transfer coefficient is obtained. The research results can be used to improve the cooling efficiency and enhance the heat and mass transfer of CWCT.
- 26 July 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 14 (3) , 1-34
Thermodynamic Investigation on the Performance of Closed Wet Cooling Tower
Closed wet cooling tower (CWCT) is an indirect-contact evaporative cooler, in which ambient air, spray water, and process water function together. In order to improve its thermal performance, a new heat transfer strategy is proposed. The influence of fan frequency, spray density, and processing water flow on the thermal performance of CWCT is obtained by combining theoretical and experimental research. By fitting the experimental data, the empirical formula of heat and mass transfer coefficient is obtained. The research results can be used to improve the cooling efficiency and enhance the heat and mass transfer of CWCT.
- Open Access
- 1 June 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 774 (1) , 012142
Numerical simulation of hydraulic transients in hydropower station with complicated water conveyance system
With the construction of Jinping II hydropower station with extra-large diversion tunnel, Baihetan hydropower station with complicated tailwater system, Yangfanggou hydropower station with complicated surge chamber, High requirements are put forward for the calculation and analysis of hydraulic transient process. In the water transmission and power generation system design of these projects, the following technical problems was solved by Power China Huadong Engineering Corporation Limited: simulation of variable impedance coefficient of differential surge chamber, interface tracking analysis of free-surface-pressure flow system, narrow upper chamber open channel effect and simulation of trigeminy surge chamber. The solutions to those technical problems and were summarized, and the hydraulic transients simulation and calculation software of complex waterway system - Hysim was developed. Based on the field test of Jinping II Hydropower Station, Baihetan hydropower station and Yangfanggou hydropower station, the simulation calculations were carried out. The accuracy of the hydraulic transients simulation software is verified by comparing the inversion results with the test values.
- 1 June 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 774 (1) , 012142
Open AccessNumerical simulation of hydraulic transients in hydropower station with complicated water conveyance system
With the construction of Jinping II hydropower station with extra-large diversion tunnel, Baihetan hydropower station with complicated tailwater system, Yangfanggou hydropower station with complicated surge chamber, High requirements are put forward for the calculation and analysis of hydraulic transient process. In the water transmission and power generation system design of these projects, the following technical problems was solved by Power China Huadong Engineering Corporation Limited: simulation of variable impedance coefficient of differential surge chamber, interface tracking analysis of free-surface-pressure flow system, narrow upper chamber open channel effect and simulation of trigeminy surge chamber. The solutions to those technical problems and were summarized, and the hydraulic transients simulation and calculation software of complex waterway system - Hysim was developed. Based on the field test of Jinping II Hydropower Station, Baihetan hydropower station and Yangfanggou hydropower station, the simulation calculations were carried out. The accuracy of the hydraulic transients simulation software is verified by comparing the inversion results with the test values.