HYHerun Yang

Herun Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Herun Yang has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Z = 6 magicity in 15C and 14B revealed by the 2H (15C, 3He)14B reaction

    by H.Y. Zhu, J.L. Lou, Y.L. Ye, D.Y. Pang, M.R. Xie, J.G. Li, C.X. Yuan, S.L. Jin, Z.H. Yang, X.F. Yang, et al.

  • Erratum: Development and application of position-sensitive double parallel-plate avalanche counter

    by C. Yuan, F.S. Shi, X.D. Xu, Z.C. Zhang, E.Q. Liu, H.R. Yang, P. Ma, L.M. Duan, H.J. Ong, S. Terashima, et al.

  • Development and application of position-sensitive double parallel-plate avalanche counter

    by C. Yuan, F.S. Shi, X.D. Xu, Z.C. Zhang, E.Q. Liu, H.R. Yang, P. Ma, L.M. Duan, H.J. Ong, S. Terashima, et al.

    Double parallel-plate avalanche counters (DPPACs), each comprising two PPACs with delay-line readout for two-dimensional position determination, have been developed at Institute of Modern Physics, Chinese Academy of Sciences. The detector was tested with a standard α source, achieving a position resolution of about 0.4 mm. Each PPAC measures particle hit positions in two dimensions, with the dual configuration enhancing overall detection efficiency. Two DPPACs were deployed in a month-long experimental campaign at the Radioactive Ion Beam Line in Lanzhou (RIBLL1) with secondary beams of 10 Be and 10,11,16 C, and faint 18 O primary beam at typical intensities of 1.2–1.5 × 10 5 Hz, yielding a stable single DPPAC-detection efficiency > 90% and a typical in-beam position resolution ≈ 0.56 mm. This successful deployment addresses a critical domestic need for reliable, high-resolution beam monitoring and establishes a robust technological foundation for future experiments.

  • Experimental study of bremsstrahlung γ -ray emission and short-range correlations in Sn 124 + Sn 124 collisions at 25 MeV/nucleon

    by Junhuai Xu, Qinglin Niu, Yuhao Qin, Dawei Si, Yijie Wang, Sheng Xiao, Baiting Tian, Zhi Qin, Haojie Zhang, Boyuan Zhang, et al.


  • Open Access

    Development of a semi-cylindrical time projection chamber prototype for ($^{3}{\textrm{He}},t$) charge exchange reaction experiment

    by Zhixuan He, Meng Li, Wenjuan Bu, Chaoyuan Xiao, Xianglun Wei, Yuansheng Yang, Zhi Qin, Shanhaowei He, Tianli Qiu, Peng Ma, et al.

    The charge exchange (CE) reaction is an effective probe to study the structure of atomic nuclei in the isospin dimension, which has been studied for decades. To expand the range of nuclei studied by CE reactions to a wider range and research the structure characteristics of unstable nuclei, including the isospin symmetry, spin-isospin excitation, and nuclear symmetry energy, a semi-cylindrical time projection chamber (scTPC) prototype was designed and constructed to probe ( $$^{\textrm{3}}$$ 3 He,t) CE reactions in inverse kinematics. The 266 nm UV laser was used to achieve electron-drift-velocity calibration. The scTPC has an energy resolution (FWHM) of 5.6% for $$\alpha $$ α particles emitted by $$^{\textrm{241}}$$ 241 Am radioactive source. The position resolution of scTPC is described by the residual method. The spatial resolution on the pad plane is 409 $$\upmu $$ μ m. And the position resolution in the drift direction is 326 $$\upmu $$ μ m, equivalent to an angular resolution of 0.4 $$^\circ $$ ∘ . These performances suggest that the scTPC can measure $$\Delta E $$ Δ E and particle tracks precisely. The successful development of the scTPC prototype provides better conditions for the next step of experimental data analysis and processing.


  • Open Access

    New trapezoid-shaped Frisch-grid ionization chamber for low-energy particle measurements

    by Tianli Qiu, Yuansheng Yang, Xiaohua Yuan, Peng Ma, Meng Li, Junwei Zhang, Dong Guo, Yuxuan Yang, Xianglun Wei, Zhoubo He, et al.

    A new trapezoid-shaped Frisch-grid ionization chamber (TFG-IC) has been built as a part of a $$\varDelta {E}-E$$ Δ E - E telescope system for the detection and identification of charged particles at energies down to a few MeV. To study the effect of the drift electric field uniformity, two types of sealed windows, namely a pair of SSA (split-strip aluminized mylar film) and a pair of DSA (double-sided aluminized mylar film) sealed windows have been investigated. The detector’s performances were studied using a standard $$^{241}$$ 241 Am source at different gas pressures, and the total energy-deposit resolution achieved is about 1.1%(FWHM). The $$\varDelta {E}-E$$ Δ E - E telescope, which was composed of TFG-IC and a DSSSD (double-sided silicon strip detector), has been tested using a three-component $$\alpha $$ α source and the $$^{241}$$ 241 Am source under laboratory conditions. The results show that the energy resolution with the SSA sealed windows which provide uniform drift electric field has a smaller fluctuation than that with the DSA ones; the fluctuations are about 1% and 4% for the former and the latter, respectively. Simulations using the COMSOL software also confirmed the electric-field distortion at the edge of the detector with the DSA windows. A correlation curve between energy resolution and energy deposit of charged particles at various gas pressures and for two gas species is derived for TFG-IC with the SSA sealed windows using the measurement with the $$^{241}$$ 241 Am source. Incorporating the above results, we performed Monte Carlo simulations to evaluate the particle-identification capability of the telescope. The results show that the telescope can be extended to the identification of low-energy particles.


  • Grid ionization chamber based on stainless steel woven wire mesh

    by Meng Li, Zhoubo He, Chaoyuan Xiao, Tianli Qiu, Yuansheng Yang, Peng Ma, Chengui Lu, Xianglun Wei, Rongjiang Hu, Limin Duan, et al.

    The grid electrode of the grid ionization chamber (GIC) is devoted to eliminating the dependence of the anode pulse amplitude on the initial position and orientation of the ionization. The traditional methods of grid production require cumbersome processes and advanced instruments. In this paper, a bonded stainless steel woven wire mesh (SSWWM) grid electrode manufacturing method is proposed. Compared with the traditional grid electrode, the SSWWM grid features the advantages of simple fabrication, low cost, and high mechanical strength. The energy resolutions of the 40-mesh, 60-mesh and 80-mesh SSWWM grids and orthogonal mesh grid realized by the traditional wire winding method were tested using an 241Am source (around 5.486 MeV). The results show that the optimum energy resolution of the SSWWM and orthogonal mesh grids is approximately 47 keV full width at half-maximum (FWHM). The optimal energy resolutions of the 40-mesh and 60-mesh SSWWM grids are comparable, but the initial operating voltages corresponding to the energy resolution plateau are different, mainly because of the effect of the different geometric parameters of the SSWWM grid on the electron transmittance. A simulation program was used to study the electron transmittance of the SSWWM grid. The simulation results are in agreement with the experimental results, indicating that the simulation program can be used as a reference for the selection of the geometric parameters of the SSWWM grid.


  • Open Access

    Exploration of grid scheme for Frisch-grid ionization chamber

    by Meng Li, Yuansheng Yang, Peng Ma, Junwei Zhang, Zhi Qin, Xianglun Wei, Chaoyuan Xiao, Tianli Qiu, Zhoubo He, Zhixuan He, et al.

    A new Frisch-grid ionization chamber has been built to explore the appropriate choice of Frisch-grid. Detailed studies of the relationship between grid geometries and detector performance have been performed with an $$^{241}$$ 241 Am source. This paper describes and compares the energy resolution of ionization chambers with parallel-wire and mesh grids of different grid parameters. Some specific recommendations for grid selection are provided based on the data currently available. To obtain optimal energy resolution, the operating voltage of the chamber must satisfy the condition of minimum electron collection on the grid with distinct geometries and parameters, respectively. Since there is no established theory applicable to both types of grids, we have devised a careful simulation procedure incorporating the COMSOL and Garfield++ codes to search for the conditions of the minimum electron collection on the grid. The simulation results fit the experimental data well, suggesting that this simulation method successfully predicts the suitable voltage setting when using a mesh grid or parallel wires grid as the shielding electrode.