Andrzej Bobrowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrzej Bobrowski has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Agnieszka Królicka
Department of Building Materials Technology, Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, 30-059 Krakow, Poland
11 shared publications Jerzy Zarębski
Department of Building Materials Technology, Faculty of Materials Science and Ceramics AGH University of Science and Technology Mickiewicza 30 30-059 Krakow Poland
6 shared publicationsAnastasios Economou
Department of Chemistry, Laboratory of Analytical Chemistry, University of Athens, Athens, Greece
4 shared publications- Jerzy Zarębski
Department of Building Materials Technology, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Krakow, Poland
3 shared publications Julia Gonciarczyk
Department of Building Materials Technology, Faculty of Materials Science and Ceramics AGH University of Science and Technology Mickiewicza 30 30-059 Krakow Poland
3 shared publicationsMariola Maczuga
Faculty of Materials Science and Ceramics, Department of Building Materials Technology, AGH University of Science and Technology, Kraków, Poland
2 shared publications
Latest Publications
- Open Access
- 16 January 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (1) , 36
Application of Aminopolycarboxylic Complexes of V(IV) in Catalytic Adsorptive Stripping Voltammetry of Germanium
In the review, voltammetric analytical procedures that employ vanadium(IV) and aminopolycarboxylic complexes of V(IV) are presented and discussed. The focus of the paper is on the mechanism of vanadium-catalyzed reactions responsible for the amplification of the analytical signal of Ge(IV). The analytical efficacy of different catalytic systems is compared, and the optimal parameters of the respective procedures are reported.
- 16 January 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (1) , 36
Open AccessApplication of Aminopolycarboxylic Complexes of V(IV) in Catalytic Adsorptive Stripping Voltammetry of Germanium
In the review, voltammetric analytical procedures that employ vanadium(IV) and aminopolycarboxylic complexes of V(IV) are presented and discussed. The focus of the paper is on the mechanism of vanadium-catalyzed reactions responsible for the amplification of the analytical signal of Ge(IV). The analytical efficacy of different catalytic systems is compared, and the optimal parameters of the respective procedures are reported.
- Open Access
Catalytic Adsorptive Stripping Voltammetric Determination of Germanium Employing the Oxidizing Properties of V(IV)-HEDTA Complex and Bismuth-Modified Carbon-Based Electrodes
An efficient procedure that may be used to determine germanium traces and combines the advantages of catalytic adsorptive stripping voltammetry (CAdSV) with the convenience of screen-printed electrodes was developed. To induce the CAdSV response of the germanium(IV)-catechol complex, the vanadium(IV)-HEDTA compound was employed in combination with various bismuth-modified homogeneous (glassy carbon, gold coated with a bismuth layer via physical vapor deposition) and heterogeneous (screen-printed carbon, mesoporous carbon, graphene and reduced graphene oxide, polymer-encapsuled carbon fiber) electrodes. This solution had never before been implemented for this purpose. To achieve the most favorable performance of the working electrode, the parameters of bismuth deposition were optimized using a central composite design methodology. SEM imaging and contact angle measurements confirmed the long-term stability and high chemical resistance of the electrodes against the oxidizing action of V(IV)-HEDTA. Under optimized conditions, the method made it possible to detect nanomolar concentrations of germanium with favorable detection limits, high sensitivity, and a wide linear range of 5–90 nM of Ge(IV).
Open AccessCatalytic Adsorptive Stripping Voltammetric Determination of Germanium Employing the Oxidizing Properties of V(IV)-HEDTA Complex and Bismuth-Modified Carbon-Based Electrodes
An efficient procedure that may be used to determine germanium traces and combines the advantages of catalytic adsorptive stripping voltammetry (CAdSV) with the convenience of screen-printed electrodes was developed. To induce the CAdSV response of the germanium(IV)-catechol complex, the vanadium(IV)-HEDTA compound was employed in combination with various bismuth-modified homogeneous (glassy carbon, gold coated with a bismuth layer via physical vapor deposition) and heterogeneous (screen-printed carbon, mesoporous carbon, graphene and reduced graphene oxide, polymer-encapsuled carbon fiber) electrodes. This solution had never before been implemented for this purpose. To achieve the most favorable performance of the working electrode, the parameters of bismuth deposition were optimized using a central composite design methodology. SEM imaging and contact angle measurements confirmed the long-term stability and high chemical resistance of the electrodes against the oxidizing action of V(IV)-HEDTA. Under optimized conditions, the method made it possible to detect nanomolar concentrations of germanium with favorable detection limits, high sensitivity, and a wide linear range of 5–90 nM of Ge(IV).
- Open Access
- 30 June 2021
- Published by MDPI AG in Chemistry Proceedings
- Vol. 5 (1) , 7
Implementation of Metallic Film Electrodes for Catalytic Adsorptive Stripping Voltammetric Determination of Germanium(IV)
In the present work, it has been shown that bismuth film electrodes deposited on screen-printed carbon supports could be successfully used to provide well-shaped, sensitive and reproducible catalytic adsorptive stripping signals of Ge(IV) in the presence of catechol and V(IV)-HEDTA (HEDTA-N-hydroxyethyl-ethylene diamine-triacetic acid) complex.
- 30 June 2021
- Published by MDPI AG in Chemistry Proceedings
- Vol. 5 (1) , 7
Open AccessImplementation of Metallic Film Electrodes for Catalytic Adsorptive Stripping Voltammetric Determination of Germanium(IV)
In the present work, it has been shown that bismuth film electrodes deposited on screen-printed carbon supports could be successfully used to provide well-shaped, sensitive and reproducible catalytic adsorptive stripping signals of Ge(IV) in the presence of catechol and V(IV)-HEDTA (HEDTA-N-hydroxyethyl-ethylene diamine-triacetic acid) complex.
- 14 July 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (10) , 2213-2219
Selection of Optimal Ligand and Vanadium(IV) Complexonate for Sensitive Catalytic Adsorptive Stripping Voltammetric Quantification of Germanium
The study describes the properties of catalytic adsorptive stripping voltammetric (CAdSV) systems based on complexes of Ge(IV) with gallic acid, catechol or pyrogallol as well as vanadium complexes with complexones such as NTA, DHPTA, EDTA, and HEDTA, used as catalytic agents. The most pronounced CAdSV response was observed when the Ge(IV)‐pyrogallol complex was coupled with V(IV)‐HEDTA. In 0.05 M of acetate buffer containing 1 mM of pyrogallol, 2 mM of V(IV) and 4 mM of HEDTA, the peak current of germanium exhibited good linearity for Ge(IV) concentrations over the range from 0.25 nM to 25 nM and a low limit of detection (LOD=0.02 nM). The method was verified by measuring Ge(IV) in real water samples.
- 14 July 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (10) , 2213-2219
Selection of Optimal Ligand and Vanadium(IV) Complexonate for Sensitive Catalytic Adsorptive Stripping Voltammetric Quantification of Germanium
The study describes the properties of catalytic adsorptive stripping voltammetric (CAdSV) systems based on complexes of Ge(IV) with gallic acid, catechol or pyrogallol as well as vanadium complexes with complexones such as NTA, DHPTA, EDTA, and HEDTA, used as catalytic agents. The most pronounced CAdSV response was observed when the Ge(IV)‐pyrogallol complex was coupled with V(IV)‐HEDTA. In 0.05 M of acetate buffer containing 1 mM of pyrogallol, 2 mM of V(IV) and 4 mM of HEDTA, the peak current of germanium exhibited good linearity for Ge(IV) concentrations over the range from 0.25 nM to 25 nM and a low limit of detection (LOD=0.02 nM). The method was verified by measuring Ge(IV) in real water samples.
- Open Access
- 11 July 2020
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 24 (11-12) , 2891-2899
A novel catalytic adsorptive stripping voltammetric method for the determination of germanium ultratraces in the presence of chloranilic acid and the V(IV)·HEDTA complex
A novel, sensitive catalytic adsorptive stripping voltammetric procedure which can be used to determine trace amounts of germanium is described. The method is based on the interfacial accumulation of the complex formed by Ge(IV) and the product of the reduction of chloranilic acid on the hanging mercury drop electrode or the renewable silver amalgam film electrode, and its subsequent reduction from the adsorbed state followed by the catalytic action of the V(IV)·HEDTA complex. The presence of V(IV)·HEDTA greatly enhances the adsorptive stripping response of Ge. The reduction of the Ge(IV) in the presence of chloranilic acid and V(IV)·HEDTA was investigated in detail and the effects of pH, electrolyte composition, and instrumental parameters were studied. Under optimal conditions, the catalytic peak current of germanium exhibited good linearity for Ge(IV) concentrations in the range of 0.75–60 nM (for 60 s of accumulation at −0.1 V,r2= 0.995) and a low limit of detection (LOD = 0.085 nM). The procedure was successfully applied to determine Ge in water samples.
- 11 July 2020
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 24 (11-12) , 2891-2899
Open AccessA novel catalytic adsorptive stripping voltammetric method for the determination of germanium ultratraces in the presence of chloranilic acid and the V(IV)·HEDTA complex
A novel, sensitive catalytic adsorptive stripping voltammetric procedure which can be used to determine trace amounts of germanium is described. The method is based on the interfacial accumulation of the complex formed by Ge(IV) and the product of the reduction of chloranilic acid on the hanging mercury drop electrode or the renewable silver amalgam film electrode, and its subsequent reduction from the adsorbed state followed by the catalytic action of the V(IV)·HEDTA complex. The presence of V(IV)·HEDTA greatly enhances the adsorptive stripping response of Ge. The reduction of the Ge(IV) in the presence of chloranilic acid and V(IV)·HEDTA was investigated in detail and the effects of pH, electrolyte composition, and instrumental parameters were studied. Under optimal conditions, the catalytic peak current of germanium exhibited good linearity for Ge(IV) concentrations in the range of 0.75–60 nM (for 60 s of accumulation at −0.1 V,r2= 0.995) and a low limit of detection (LOD = 0.085 nM). The procedure was successfully applied to determine Ge in water samples.
- 11 May 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (9) , 2004-2010
Tellurium Film Electrodes Deposited on Carbon and Mesoporous Carbon Screen‐printed Substrates for Anodic Stripping Voltammetric Determination of Copper
The performance of screen‐printed electrodes modified in situ with tellurium film for the anodic stripping voltammetric (ASV) determination of Cu(II) is reported. It was found that two types of screen‐printed substrates, namely carbon and mesoporous carbon, were optimal for this application. The selected in situ tellurium film modified electrodes were applied for the square wave ASV determination of copper at μg L−1 concentration levels. Well‐defined and reproducible Cu oxidation stripping peaks were produced at a potential more negative than the anodic dissolution of tellurium. The highest sensitivity of Cu determination was achieved in 0.05 M HCl containing 50 μg L−1 Te(IV) after 300 s of accumulation at −0.5 V. Using the optimized procedure, a linear range from 2 to 35 μg L−1 of Cu(II) was obtained with a detection limit of 0.5 μg L−1 Cu(II) (S/N=3) for 300 s of deposition time. Both sensors, carbon TeF‐SPE and mesoporous carbon TeF‐SPE, were successfully applied for the quantification of Cu in a certified reference surface water sample.
- 11 May 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (9) , 2004-2010
Tellurium Film Electrodes Deposited on Carbon and Mesoporous Carbon Screen‐printed Substrates for Anodic Stripping Voltammetric Determination of Copper
The performance of screen‐printed electrodes modified in situ with tellurium film for the anodic stripping voltammetric (ASV) determination of Cu(II) is reported. It was found that two types of screen‐printed substrates, namely carbon and mesoporous carbon, were optimal for this application. The selected in situ tellurium film modified electrodes were applied for the square wave ASV determination of copper at μg L−1 concentration levels. Well‐defined and reproducible Cu oxidation stripping peaks were produced at a potential more negative than the anodic dissolution of tellurium. The highest sensitivity of Cu determination was achieved in 0.05 M HCl containing 50 μg L−1 Te(IV) after 300 s of accumulation at −0.5 V. Using the optimized procedure, a linear range from 2 to 35 μg L−1 of Cu(II) was obtained with a detection limit of 0.5 μg L−1 Cu(II) (S/N=3) for 300 s of deposition time. Both sensors, carbon TeF‐SPE and mesoporous carbon TeF‐SPE, were successfully applied for the quantification of Cu in a certified reference surface water sample.
- 21 September 2017
- Published by Taylor & Francis in Analytical Letters
- Vol. 50 (18) , 2920-2936
Determination of Copper(II) Through Anodic Stripping Voltammetry in Tartrate Buffer Using an Antimony Film Screen-printed Carbon Electrode
The voltammetric performance of an in situ plated antimony film screen-printed carbon electrode in hydrochloric acid, acetate buffer, and tartrate buffer was evaluated for the detection of copper(II) with differential pulse anodic stripping voltammetry. The tartrate buffer was superior, providing high sensitivity and good separation of copper and antimony stripping peaks. The analytical conditions for the determination of copper(II) were optimized. The detection limit was estimated to be 0.14 µg L−1 copper(II) and the relative standard deviation for 2.5 µg L−1 copper(II) was 3%. The applicability of the method was illustrated by the analysis of soil conditioner samples.
- 21 September 2017
- Published by Taylor & Francis in Analytical Letters
- Vol. 50 (18) , 2920-2936
Determination of Copper(II) Through Anodic Stripping Voltammetry in Tartrate Buffer Using an Antimony Film Screen-printed Carbon Electrode
The voltammetric performance of an in situ plated antimony film screen-printed carbon electrode in hydrochloric acid, acetate buffer, and tartrate buffer was evaluated for the detection of copper(II) with differential pulse anodic stripping voltammetry. The tartrate buffer was superior, providing high sensitivity and good separation of copper and antimony stripping peaks. The analytical conditions for the determination of copper(II) were optimized. The detection limit was estimated to be 0.14 µg L−1 copper(II) and the relative standard deviation for 2.5 µg L−1 copper(II) was 3%. The applicability of the method was illustrated by the analysis of soil conditioner samples.
- 9 June 2016
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 20 (12) , 3217-3228
Renewable silver amalgam film electrodes in electrochemical stripping analysis—a review
- 9 June 2016
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 20 (12) , 3217-3228
Renewable silver amalgam film electrodes in electrochemical stripping analysis—a review
- 29 July 2015
- Published by Wiley in Electroanalysis
- Vol. 28 (2) , 343-349
Highly Sensitive and Selective Adsorptive Stripping Voltammetric Method Employing a Lead Film Screen‐printed Electrode for Determination of Cobalt as its Nioximate Complex
A carbon screen‐printed electrode modified in‐situ with lead film (PbF‐SPCE) was applied for the adsorptive stripping voltammetric determination of Co(II) in the form of a complex with 1,2‐cyclohexanedione dioxime. Lead film was electrochemically deposited in situ on SPCE from a 0.2 M ammonia buffer solution (pH 8.7) containing 5 ⋅ 10−5 M Pb(NO3)2 and 5 ⋅ 10−5 M nioxime. Due to the very low LOD (0.003 µgL−1, i.e., 0.05 nmol L−1 Co(II); tacc=120s), the developed procedure could be rated among the most sensitive methods employing SPEs. The Ni(II) signal was significantly lower than the Co(II) one and the separation of Ni(II) and Co(II) peaks was even better at the PbF‐SPCE than at the hanging mercury drop electrode.
- 29 July 2015
- Published by Wiley in Electroanalysis
- Vol. 28 (2) , 343-349
Highly Sensitive and Selective Adsorptive Stripping Voltammetric Method Employing a Lead Film Screen‐printed Electrode for Determination of Cobalt as its Nioximate Complex
A carbon screen‐printed electrode modified in‐situ with lead film (PbF‐SPCE) was applied for the adsorptive stripping voltammetric determination of Co(II) in the form of a complex with 1,2‐cyclohexanedione dioxime. Lead film was electrochemically deposited in situ on SPCE from a 0.2 M ammonia buffer solution (pH 8.7) containing 5 ⋅ 10−5 M Pb(NO3)2 and 5 ⋅ 10−5 M nioxime. Due to the very low LOD (0.003 µgL−1, i.e., 0.05 nmol L−1 Co(II); tacc=120s), the developed procedure could be rated among the most sensitive methods employing SPEs. The Ni(II) signal was significantly lower than the Co(II) one and the separation of Ni(II) and Co(II) peaks was even better at the PbF‐SPCE than at the hanging mercury drop electrode.