EPEfstathios Papavassiliou

Efstathios Papavassiliou

*This is an algorithmically generated author record based on publicly available information.

Efstathios Papavassiliou has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Foundations of Robotic Spine Surgery: Emerging Technologies and Future Directions

    by Fernando Terry, Alejandro Enriquez-Marulanda, Punit Pandya, Forough Yazdanian, Efstathios Papavassiliou, Ziev B. Moses

    Robotic technology is increasingly employed in minimally invasive spine surgery (MISS) to mitigate morbidity, operative duration, radiation exposure, and complications. The first FDA-approved (2004) robotic platform was the SpineAssist by Mazor Robotics, followed by the Mazor Renaissance (2011), and the Mazor X Stealth System (2016). These sequential Mazor generations featured enhancements in human interface, hardware, software, range of motion and system capacity. Additional robotic spine surgery systems are the ROSA robot by Zimmer Biomet, the ExcelsiusGPS by Globus Medical and REMI by Alphatec Spine. Some modern stations like the TiRobot have been approved by their country’s governmental regulatory agencies. As spine surgery increasingly transitions to outpatient settings, there is a growing preference for smaller robotic platforms. Lastly, robot-guided endoscopic spine surgery (ESS) represents a significant advancement in ultra-minimally invasive techniques, combining robotic precision with endoscopic methods to enhance surgical outcomes. While it offers benefits like reduced recovery time and improved visualization, challenges such as the steep learning curve and high costs exist, necessitating further long-term studies to evaluate its efficacy and viability. Based on this foundation, this chapter will delineate the historical progression of robotic spine surgery techniques, as well as explore the continuous emergence of novel modalities through rigorous methodological assessment.


  • Factors Predictive of Adjacent Segment Disease After Lumbar Spinal Fusion

    by Georgios A. Maragkos, Rouzbeh Motiei-Langroudi, Aristotelis S. Filippidis, Paul A. Glazer, Efstathios Papavassiliou


  • Intracranial hypertension after Chiari decompression resolving after removal of a levonorgestrel-releasing intrauterine device: case report

    by Georgios A. Maragkos, Rouzbeh Motiei-Langroudi, Aristotelis S. Filippidis, Efstathios Papavassiliou

    Levonorgestrel-releasing intrauterine devices (LIUDs) are thought to release this progestin locally in the uterus to limit side effects. Authors here present a case of treatment-refractory hydrocephalus and pseudomeningocele (PMC), both of which fully resolved after LIUD removal.A 35-year-old woman with an implanted LIUD developed symptomatic PMC and hydrocephalus after suboccipital craniectomy for Chiari malformation type I. Over the next 8 months, she underwent ventriculoperitoneal shunt placement and two attempts at needle decompression of the fluid collection, which did not relieve her symptoms or the PMC, except for a few days at a time. Subsequently, she had her LIUD removed. Three weeks after removal of the LIUD, her symptoms as well as the fluid collection resolved completely without any further intervention. Thus, the increased intracranial pressure and associated persistence of the PMC may be partially attributed to the LIUD.This case indicates that a persistent problem (PMC and intracranial hypertension) that may be associated with the LIUD rapidly resolves after its removal. Implication of LIUDs as the cause of intracranial hypertension is still a matter of controversy. Further studies are needed to evaluate any potential causal relationship between LIUDs and intracranial hypertension, and physicians are advised to consider this scenario in their differential diagnosis.


  • Open Access

    Commentary: Thoracolumbar Vertebral Column Resection With Rectangular Endplate Cages Through a Posterior Approach: Surgical Techniques and Early Postoperative Outcomes

    by Georgios A Maragkos, Efstathios Papavassiliou

    The authors1 present a case series of 45 patients undergoing thoracolumbar vertebral column resection (VCR) and fusion through a posterior-only approach. They utilized wide-footprint, expandable cages with rectangular endplates, originally designed for transthoracic and retroperitoneal approaches. The reasoning is that these cages take advantage of the apophyseal ring, the strongest part of the vertebral endplate, in order to potentially have better area contact, higher fusion rates, and less subsidence. Their series primarily consists of tumors and osteomyelitis cases, and less so deformities. The authors should be commended on providing such an informative description of the procedure in their methods section, as well as incorporating a video to help visualize the technique. Overall, the manuscript is well-written and addresses key questions that arise. We would like to point out some additional details that should be considered by the reader.