Yiqing Zou
Yiqing Zou has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Lei Qin
Liuzhou OVM Machinery Co Ltd, Liuzhou, Peoples R China
2 shared publications- Limin Sun
Tongji University
2 shared publications - Lin Chen
Tongji University
2 shared publications - Damin Lu
School of Civil and Architectural Engineering, Guangxi University of Science and Technology, Liuzhou 545006, China
1 shared publication Fangwei Huang
1 shared publication- Guilin Yang
School of Civil and Architectural Engineering, Guangxi University of Science and Technology, Liuzhou 545006, China
1 shared publication
Latest Publications
- Open Access
Mechanical Property Degradation Behavior and Fatigue Life Analysis of Corroded High-Strength Steel Wires
Investigating the effects of corrosion on the mechanical and fatigue properties of steel wires is critical for the safety assessment of bridge cable structures.This study focuses on high-strength galvanized steel wires used for bridge cables, with a diameter of 7 mm and a strength grade of 1770 MPa. Specimens with varying mass loss rates η were prepared by electrochemical corrosion method, and systematic tensile and fatigue tests were conducted to study the effects of corrosion on the fundamental mechanical properties and fatigue life of the steel wires. The results indicate that the elastic modulus of the steel wires decreases slightly with the increase of η but still meets the requirements of relevant standards. In contrast, the yield strength and tensile strength degrade significantly, while ductility is particularly susceptible to corrosion, showing more severe deterioration. When η is less than 2.75%, the corroded steel wires still maintain favorable fatigue resistance at a nominal stress amplitude of 360 MPa. Once η exceeds this threshold, their fatigue life decreases significantly in a nonlinear manner with increasing η. The fatigue life predicted by a finite element model (FEM) reconstructed based on the 3D scanning geometry of corroded steel wires and combined with the Abaqus/fe-safe module shows good agreement with the experimental results, indicating that this approach can provide a valuable reference for the durability assessment of bridge cables.
Open AccessMechanical Property Degradation Behavior and Fatigue Life Analysis of Corroded High-Strength Steel Wires
Investigating the effects of corrosion on the mechanical and fatigue properties of steel wires is critical for the safety assessment of bridge cable structures.This study focuses on high-strength galvanized steel wires used for bridge cables, with a diameter of 7 mm and a strength grade of 1770 MPa. Specimens with varying mass loss rates η were prepared by electrochemical corrosion method, and systematic tensile and fatigue tests were conducted to study the effects of corrosion on the fundamental mechanical properties and fatigue life of the steel wires. The results indicate that the elastic modulus of the steel wires decreases slightly with the increase of η but still meets the requirements of relevant standards. In contrast, the yield strength and tensile strength degrade significantly, while ductility is particularly susceptible to corrosion, showing more severe deterioration. When η is less than 2.75%, the corroded steel wires still maintain favorable fatigue resistance at a nominal stress amplitude of 360 MPa. Once η exceeds this threshold, their fatigue life decreases significantly in a nonlinear manner with increasing η. The fatigue life predicted by a finite element model (FEM) reconstructed based on the 3D scanning geometry of corroded steel wires and combined with the Abaqus/fe-safe module shows good agreement with the experimental results, indicating that this approach can provide a valuable reference for the durability assessment of bridge cables.
- Open Access
Binocular Stereo Vision-Based Structured Light Scanning System Calibration and Workpiece Surface Measurement Accuracy Analysis
Precise online measurement of large structural components is urgently needed in modern manufacturing and intelligent construction, requiring a measurement range over 1 m, near-millimeter accuracy, second-level measurement speed, and adaptability to complex environments. In this paper, three mainstream measurement technologies, namely the image method, line laser scanning method, and structured light method, are comparatively analyzed. The structured light method exhibits remarkable comprehensive advantages in terms of accuracy and speed; however, it suffers from the issue of occlusion during contour measurement. To tackle this problem, multi-camera stitching is employed, wherein the accuracy of camera calibration plays a crucial role in determining the quality of point cloud stitching. Focusing on the cable tightening scenario of meter-diameter cables in cable-stayed bridges, this study develops a contour measurement system based on the collaboration of multiple structured light cameras. Measurement indicators are optimized through modeling analysis, system construction, and performance verification. During verification, four structured light scanners were adopted, and measurements were repeated 11 times for the test workpieces. Experimental results demonstrate that although the current measurement errors have not yet been stably controlled within the millimeter level, this research provides technical exploration and practical experience for high-precision measurement in the field of intelligent construction, thus laying a solid foundation for subsequent accuracy improvement.
Open AccessBinocular Stereo Vision-Based Structured Light Scanning System Calibration and Workpiece Surface Measurement Accuracy Analysis
Precise online measurement of large structural components is urgently needed in modern manufacturing and intelligent construction, requiring a measurement range over 1 m, near-millimeter accuracy, second-level measurement speed, and adaptability to complex environments. In this paper, three mainstream measurement technologies, namely the image method, line laser scanning method, and structured light method, are comparatively analyzed. The structured light method exhibits remarkable comprehensive advantages in terms of accuracy and speed; however, it suffers from the issue of occlusion during contour measurement. To tackle this problem, multi-camera stitching is employed, wherein the accuracy of camera calibration plays a crucial role in determining the quality of point cloud stitching. Focusing on the cable tightening scenario of meter-diameter cables in cable-stayed bridges, this study develops a contour measurement system based on the collaboration of multiple structured light cameras. Measurement indicators are optimized through modeling analysis, system construction, and performance verification. During verification, four structured light scanners were adopted, and measurements were repeated 11 times for the test workpieces. Experimental results demonstrate that although the current measurement errors have not yet been stably controlled within the millimeter level, this research provides technical exploration and practical experience for high-precision measurement in the field of intelligent construction, thus laying a solid foundation for subsequent accuracy improvement.
- 1 January 2025
- Published by Prestress Technology in Prestress Technology
- Vol. 3 (04) , 11-24
A Study on the Mechanical Performance of Concrete Anchorage Zones with Welded Bearing Plates
A welded bearing plate is a novel structural component for force transmission in prestressed concrete. Its bearing capacity in the anchorage zone is directly related to the overall safety of the prestressed concrete structure. Elastoplastic deformation, damage evolution, and failure mechanisms within the anchorage zone under prestressing loads remain pivotal scientific issues that necessitate in-depth investigation. In this study, a numerical model of the concrete anchorage zone with welded bearing plates is developed with ANSYS software. Comprehensive simulations are carried out to analyze the structural response from initial deformation to ultimate failure under cyclic and vertical displacement loads. The accuracy of the proposed numerical model is verified through a comparative analysis with existing experimental results. Parametric studies are conducted to systematically assess the influence of key design parameters, such as the base plate thickness, flared tube diameter, and wall thickness, on the stress distribution and ultimate load, leading to structural optimization of the bearing plate, which is further validated by physical testing. The results indicate that the plastic-damage microplane model effectively captures the localized compressive behavior and agrees with the experimental observations, thus confirming its feasibility and applicability. In addition, the load-carrying capacity and stress distribution are significantly improved by increasing the base plate and flared tube thickness, with the base plate thickness having a more pronounced effect. Both parameters are generally positively correlated with structural performance. In contrast, variations in the flared tube diameter have a relatively marginal effect. Following structural optimization, the load-transfer performance of the welded bearing plate is superior to that of the original design, particularly in terms of its higher ultimate load capacity and ability to controls cracks control (i.e., delayed initiation and reduced propagation). These findings provide valuable theoretical insights and data support for evaluating load capacity, understanding stress distribution mechanisms, and optimizing the engineering design of concrete anchorage zones.
- 1 January 2025
- Published by Prestress Technology in Prestress Technology
- Vol. 3 (04) , 11-24
A Study on the Mechanical Performance of Concrete Anchorage Zones with Welded Bearing Plates
A welded bearing plate is a novel structural component for force transmission in prestressed concrete. Its bearing capacity in the anchorage zone is directly related to the overall safety of the prestressed concrete structure. Elastoplastic deformation, damage evolution, and failure mechanisms within the anchorage zone under prestressing loads remain pivotal scientific issues that necessitate in-depth investigation. In this study, a numerical model of the concrete anchorage zone with welded bearing plates is developed with ANSYS software. Comprehensive simulations are carried out to analyze the structural response from initial deformation to ultimate failure under cyclic and vertical displacement loads. The accuracy of the proposed numerical model is verified through a comparative analysis with existing experimental results. Parametric studies are conducted to systematically assess the influence of key design parameters, such as the base plate thickness, flared tube diameter, and wall thickness, on the stress distribution and ultimate load, leading to structural optimization of the bearing plate, which is further validated by physical testing. The results indicate that the plastic-damage microplane model effectively captures the localized compressive behavior and agrees with the experimental observations, thus confirming its feasibility and applicability. In addition, the load-carrying capacity and stress distribution are significantly improved by increasing the base plate and flared tube thickness, with the base plate thickness having a more pronounced effect. Both parameters are generally positively correlated with structural performance. In contrast, variations in the flared tube diameter have a relatively marginal effect. Following structural optimization, the load-transfer performance of the welded bearing plate is superior to that of the original design, particularly in terms of its higher ultimate load capacity and ability to controls cracks control (i.e., delayed initiation and reduced propagation). These findings provide valuable theoretical insights and data support for evaluating load capacity, understanding stress distribution mechanisms, and optimizing the engineering design of concrete anchorage zones.
- Open Access
- 14 September 2024
- Published by Elsevier in Measurement
- Vol. 242
Simplification and improvement of cable tension identification based on effective vibration length estimated from multiple sensors located near one support
- 14 September 2024
- Published by Elsevier in Measurement
- Vol. 242
Open AccessSimplification and improvement of cable tension identification based on effective vibration length estimated from multiple sensors located near one support
- 28 March 2023
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 42 (2) , 1-19
Defect Characterization Method for Bridge Cables Based on Topology of Dynamical Reconstruction of Magnetostrictive Guided Wave Testing Signals
- 28 March 2023
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 42 (2) , 1-19
Defect Characterization Method for Bridge Cables Based on Topology of Dynamical Reconstruction of Magnetostrictive Guided Wave Testing Signals
- 1 January 2023
- Published by Prestress Technology in Prestress Technology
- Vol. 27 (01) , 53-67
Technical Research on Fatigue Resistance and Durability of OVM250 Parallel Strand Cable System
With the development of modern long-span cable-stayed bridges, due to the parallel strand cable (PSC) being assembled on-site strand by strand, which has the advantages such as no need for large-scale equipment for cable-making, delivery, hoisting, traction, tensioning, and the corrosion protection of the cable is excellent, it is more and more favored by designers. As load-bearing components, the stay cables are known as the life cable of the cable-stayed bridge. Its reliability and durability are the key factors that determine the safety and the service life of the cable-stayed bridge. In accordance with the requirements specified in international recommendations, in-depth research has been carried out on cable fatigue, anti-corrosion, and vibration control to optimize OVM250 PSC system. All research results have been successfully applied to cable stayed bridge projects.
- 1 January 2023
- Published by Prestress Technology in Prestress Technology
- Vol. 27 (01) , 53-67
Technical Research on Fatigue Resistance and Durability of OVM250 Parallel Strand Cable System
With the development of modern long-span cable-stayed bridges, due to the parallel strand cable (PSC) being assembled on-site strand by strand, which has the advantages such as no need for large-scale equipment for cable-making, delivery, hoisting, traction, tensioning, and the corrosion protection of the cable is excellent, it is more and more favored by designers. As load-bearing components, the stay cables are known as the life cable of the cable-stayed bridge. Its reliability and durability are the key factors that determine the safety and the service life of the cable-stayed bridge. In accordance with the requirements specified in international recommendations, in-depth research has been carried out on cable fatigue, anti-corrosion, and vibration control to optimize OVM250 PSC system. All research results have been successfully applied to cable stayed bridge projects.
- 1 January 2021
- Published by International Association for Bridge and Structural Engineering (IABSE)
- Vol. 20, 1651-1657
An experimental study of cable tension identification based on measurements of mode shapes
Cable tension identification based on mode shapes extracted from vibration measurements is a relatively new method. In this method, the cable is equivalent to a beam model hinged at its ends and under axial tension with an unknown length to eliminate the effects of boundary conditions. This study focuses on the influences of sensor arrangement in the measurements on the accuracy of the tension identification. For this purpose, full-scale cable experiments have been carried out, where a number of sensors were attached to the cable to record cable acceleration during artificial excitation. The eigenvalue realization algorithm (ERA) has then been applied to identify the mode shapes and frequencies of the cables from the multiple acceleration measurements. The effects of different sensor arrangement schemes and cable tension identification method based on higher- order modes are compared and discussed.
- 1 January 2021
- Published by International Association for Bridge and Structural Engineering (IABSE)
- Vol. 20, 1651-1657
An experimental study of cable tension identification based on measurements of mode shapes
Cable tension identification based on mode shapes extracted from vibration measurements is a relatively new method. In this method, the cable is equivalent to a beam model hinged at its ends and under axial tension with an unknown length to eliminate the effects of boundary conditions. This study focuses on the influences of sensor arrangement in the measurements on the accuracy of the tension identification. For this purpose, full-scale cable experiments have been carried out, where a number of sensors were attached to the cable to record cable acceleration during artificial excitation. The eigenvalue realization algorithm (ERA) has then been applied to identify the mode shapes and frequencies of the cables from the multiple acceleration measurements. The effects of different sensor arrangement schemes and cable tension identification method based on higher- order modes are compared and discussed.