    Ultrasound Probe Calibration Method of Single-Wire Phantom Using Levenberg-Marquardt Algorithm

    by Tri Arief Sardjono, Eko Mulyanto Yuniarno, I Made Gede Sunarya, I Ketut Eddy Purnama, Mauridhi Hery Purnomo, Norma Hermawan

    A freehand three-dimensional (3D) ultrasound system is a method of acquiring images using a 3D ultrasound probe or conventional two-dimensional (2D) ultrasound probe to give a 3D visualization of an object inside the body. Ultrasounds are used extensively in clinical applications since they are advantageous in that they do not bring dangerous radiation effects and have a low cost. However, a probe calibration method is needed to transform the coordinate position into a 3D visualization display, especially for image-guided intervention. The current ultrasound probe calibration system usually uses the numerical regression method for the N-wire phantom, which has problems in accuracy and reliability due to nonlinear point scattered ultrasound image data. Hence, a method for ultrasound probe positional calibration of single-wire phantom using the Levenberg-Marquardt algorithm (LMA) was proposed to overcome this weakness. This experiment consisted of an optical tracking system setup, a 2D ultrasound probe with marker, an ultrasound machine, and a single-wire object in a water container equipped with a marker. The position and orientation of the marker in a 2D ultrasound probe and the marker in the water container were tracked using the optical tracking system. A 2D ultrasound probe was equipped with a marker connected wirelessly using an optical tracking system to capture the single-wire object. The resulting sequences of 2D ultrasound images were reconstructed and visualized into 3D ultrasound images using three transformations, ultrasound beam to ultrasound probe’s marker, single-wire phantom position to container’s marker, and the 3D visualization transformation. The LMA was used to determine the best optimization parameters for determining the exact position and representing that 3D visualization. The experiment result showed that the lowest mean square error (MSE), rotation error, and translation error were 0.45 mm, 0.25°, and 0.3828 mm, respectively.

  • Color Doppler shear wave elastography using commercial ultrasound machine with compensated transducer scanning delay

    by Norma Hermawan, Takuro Ishii, Yoshifumi Saijo

    Purpose Tissue elasticity can be measured and mapped using color Doppler elastography. In a previous study, a binary pattern of shear waves was observed using a color flow imaging (CFI) system with matched pulse Doppler packet size as well as shear wave frequency and displacement condition. In the present study, we demonstrate the possibility of mapping shear wave velocity and resolving phantom elasticity using any commercial ultrasound machine without fulfilling that condition. Methods We derive a relation between Doppler autocorrelator integration time and the estimated flow velocity. The underlying principles behind the shear wave shadows captured by a typical modern ultrasound machine are investigated. The ultrasound machine measurement preset is calibrated to remove the effect of transducer array scanning delay in modifying the appearing wavenumber and thus correct the measurement error. Results The method was used to successfully measure the elasticity of a biological tissue-mimicking phantom and distinguish a stiff phantom from a soft phantom. Conclusion Using this method, the elasticity of a biological tissue-mimicking phantom can be recovered with less strict constraint. As a result, it provides more flexibility to be implemented in common ultrasound machines. This method may be practically used to help identify tissue stiffness-related disease.


  • Binary Pattern Color Doppler Shear Wave Elastography

    by Norma Hermawan, Aoi Sato, Mizuki Fujiwara, Takuro Ishii, Yoshihiro Hagiwara, Yoshiki Yamakoshi, Yoshifumi Saijo

    Some studies suggested a correlation between tissue elasticity and diseases, such as Adhesive Capsulitis (AC) of the shoulder. One category of method to measure elasticity is by utilizing Doppler imaging. This paper discusses color Doppler shear wave elastography methods and demonstrated an experiment with biological tissue mimicking phantom. A simulation with binary pattern color Doppler shear wave elastography shows that wavelength of a shear wave with suggested magnitude is equal to four multiple of pitch strip in a color flow image. However, the larger amplitude changes the duty ratio and frequency of the pattern. An experiment with biological tissue mimicking Polyvinyl Alcohol (PVA) phantoms has shown that the binary pattern color Doppler method has successfully recovered shear wave velocity map and calculate the elasticity.Clinical Relevance—The result of experiments presents a possibility of using the method for quantitatively access the stage of tissue stiffness related disease.

  • Open Access

    Large Amplitude Harmonic Vibration under Pulse Doppler Measurement

    by N Hermawan, T Ishii, Y Yamakoshi, Y Saijo

    A flow velocity or tissue motion can be measured by pulse Doppler method. However, when the method is applied to a sinusoid motion or harmonic vibration, the estimation result is deviated. In this paper, the generalized theory of pulse Doppler measurement to the sinusoid motion is explained and the relation between the estimation deviation and the real value is given. Furthermore, a special case of binary velocity estimation is expanded and simulated with different parameters. This simulation result suggested that different selection of parameters may fundamentally affect the output of pulse Doppler estimation.

  • Wireless ECG Electrode to Improve Tele-cardiac Monitoring Usability

    by Norma Hermawan, Achmad Arifin, Fauzan Arrofiqi, Mohammad Nuh, Yoshifumi Saijo

  • Open Access

    Sistem Pelaporan Telecardiac Monitoring Melalui Layanan Pesan Singkat (SMS)

    by Norma Hermawan, Achmad Arifin, Muhammad Farid Retistianto

    Sistem Pelaporan Telecardiac Monitoring Melalui Layanan Pesan Singkat (SMS)


  • Open Access

    Architecture of RAM-Accumulator based Multichannel Digital PWM

    by Norma Hermawan

    Traditional counter based digital Pulse Width Modulator (PWM) has been a straightforward architecture. However, realization of multichannel PWM with such design requires considerable logic gates. A novel architecture of multichannel PWM based on the usage of RAM block and frequency word accumulator is proposed. This architecture is capable of producing numerous channels while maintaining its performance. The design was tested in Microsemi SmartFusion A2F200 Customizable System on Chip, giving the result of 7.73% FPGA usage to produce 48 channels of 380Hz 16 bits PWM. The output performance for test application is acceptable.