Norma Hermawan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Norma Hermawan has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Yoshifumi Saijo
Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
2 shared publicationsAchmad Arifin
Institut Teknologi Sepuluh Nopember
1 shared publication- Achmad Arifin
Departemen Teknik Biomedik Institut Teknologi Sepuluh Nopember Surabaya
1 shared publication Aoi Sato
Tohoku University,Graduate School of Biomedical Engineering,Sendai,Japan,980-8579
1 shared publication- Eko Mulyanto Yuniarno
Institut Teknologi Sepuluh Nopember
1 shared publication Fauzan Arrofiqi
Institut Teknologi Sepuluh Nopember
1 shared publication
Latest Publications
- Open Access
- 1 August 2023
- Published by Universitas Gadjah Mada in Jurnal Nasional Teknik Elektro dan Teknologi Informasi
- Vol. 12 (3) , 212-218
Ultrasound Probe Calibration Method of Single-Wire Phantom Using Levenberg-Marquardt Algorithm
A freehand three-dimensional (3D) ultrasound system is a method of acquiring images using a 3D ultrasound probe or conventional two-dimensional (2D) ultrasound probe to give a 3D visualization of an object inside the body. Ultrasounds are used extensively in clinical applications since they are advantageous in that they do not bring dangerous radiation effects and have a low cost. However, a probe calibration method is needed to transform the coordinate position into a 3D visualization display, especially for image-guided intervention. The current ultrasound probe calibration system usually uses the numerical regression method for the N-wire phantom, which has problems in accuracy and reliability due to nonlinear point scattered ultrasound image data. Hence, a method for ultrasound probe positional calibration of single-wire phantom using the Levenberg-Marquardt algorithm (LMA) was proposed to overcome this weakness. This experiment consisted of an optical tracking system setup, a 2D ultrasound probe with marker, an ultrasound machine, and a single-wire object in a water container equipped with a marker. The position and orientation of the marker in a 2D ultrasound probe and the marker in the water container were tracked using the optical tracking system. A 2D ultrasound probe was equipped with a marker connected wirelessly using an optical tracking system to capture the single-wire object. The resulting sequences of 2D ultrasound images were reconstructed and visualized into 3D ultrasound images using three transformations, ultrasound beam to ultrasound probe’s marker, single-wire phantom position to container’s marker, and the 3D visualization transformation. The LMA was used to determine the best optimization parameters for determining the exact position and representing that 3D visualization. The experiment result showed that the lowest mean square error (MSE), rotation error, and translation error were 0.45 mm, 0.25°, and 0.3828 mm, respectively.
- 1 August 2023
- Published by Universitas Gadjah Mada in Jurnal Nasional Teknik Elektro dan Teknologi Informasi
- Vol. 12 (3) , 212-218
Open AccessUltrasound Probe Calibration Method of Single-Wire Phantom Using Levenberg-Marquardt Algorithm
A freehand three-dimensional (3D) ultrasound system is a method of acquiring images using a 3D ultrasound probe or conventional two-dimensional (2D) ultrasound probe to give a 3D visualization of an object inside the body. Ultrasounds are used extensively in clinical applications since they are advantageous in that they do not bring dangerous radiation effects and have a low cost. However, a probe calibration method is needed to transform the coordinate position into a 3D visualization display, especially for image-guided intervention. The current ultrasound probe calibration system usually uses the numerical regression method for the N-wire phantom, which has problems in accuracy and reliability due to nonlinear point scattered ultrasound image data. Hence, a method for ultrasound probe positional calibration of single-wire phantom using the Levenberg-Marquardt algorithm (LMA) was proposed to overcome this weakness. This experiment consisted of an optical tracking system setup, a 2D ultrasound probe with marker, an ultrasound machine, and a single-wire object in a water container equipped with a marker. The position and orientation of the marker in a 2D ultrasound probe and the marker in the water container were tracked using the optical tracking system. A 2D ultrasound probe was equipped with a marker connected wirelessly using an optical tracking system to capture the single-wire object. The resulting sequences of 2D ultrasound images were reconstructed and visualized into 3D ultrasound images using three transformations, ultrasound beam to ultrasound probe’s marker, single-wire phantom position to container’s marker, and the 3D visualization transformation. The LMA was used to determine the best optimization parameters for determining the exact position and representing that 3D visualization. The experiment result showed that the lowest mean square error (MSE), rotation error, and translation error were 0.45 mm, 0.25°, and 0.3828 mm, respectively.
- 28 February 2022
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 49 (2) , 163-173
Color Doppler shear wave elastography using commercial ultrasound machine with compensated transducer scanning delay
Purpose Tissue elasticity can be measured and mapped using color Doppler elastography. In a previous study, a binary pattern of shear waves was observed using a color flow imaging (CFI) system with matched pulse Doppler packet size as well as shear wave frequency and displacement condition. In the present study, we demonstrate the possibility of mapping shear wave velocity and resolving phantom elasticity using any commercial ultrasound machine without fulfilling that condition. Methods We derive a relation between Doppler autocorrelator integration time and the estimated flow velocity. The underlying principles behind the shear wave shadows captured by a typical modern ultrasound machine are investigated. The ultrasound machine measurement preset is calibrated to remove the effect of transducer array scanning delay in modifying the appearing wavenumber and thus correct the measurement error. Results The method was used to successfully measure the elasticity of a biological tissue-mimicking phantom and distinguish a stiff phantom from a soft phantom. Conclusion Using this method, the elasticity of a biological tissue-mimicking phantom can be recovered with less strict constraint. As a result, it provides more flexibility to be implemented in common ultrasound machines. This method may be practically used to help identify tissue stiffness-related disease.
- 28 February 2022
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 49 (2) , 163-173
Color Doppler shear wave elastography using commercial ultrasound machine with compensated transducer scanning delay
Purpose Tissue elasticity can be measured and mapped using color Doppler elastography. In a previous study, a binary pattern of shear waves was observed using a color flow imaging (CFI) system with matched pulse Doppler packet size as well as shear wave frequency and displacement condition. In the present study, we demonstrate the possibility of mapping shear wave velocity and resolving phantom elasticity using any commercial ultrasound machine without fulfilling that condition. Methods We derive a relation between Doppler autocorrelator integration time and the estimated flow velocity. The underlying principles behind the shear wave shadows captured by a typical modern ultrasound machine are investigated. The ultrasound machine measurement preset is calibrated to remove the effect of transducer array scanning delay in modifying the appearing wavenumber and thus correct the measurement error. Results The method was used to successfully measure the elasticity of a biological tissue-mimicking phantom and distinguish a stiff phantom from a soft phantom. Conclusion Using this method, the elasticity of a biological tissue-mimicking phantom can be recovered with less strict constraint. As a result, it provides more flexibility to be implemented in common ultrasound machines. This method may be practically used to help identify tissue stiffness-related disease.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 3293-3296
Binary Pattern Color Doppler Shear Wave Elastography
Some studies suggested a correlation between tissue elasticity and diseases, such as Adhesive Capsulitis (AC) of the shoulder. One category of method to measure elasticity is by utilizing Doppler imaging. This paper discusses color Doppler shear wave elastography methods and demonstrated an experiment with biological tissue mimicking phantom. A simulation with binary pattern color Doppler shear wave elastography shows that wavelength of a shear wave with suggested magnitude is equal to four multiple of pitch strip in a color flow image. However, the larger amplitude changes the duty ratio and frequency of the pattern. An experiment with biological tissue mimicking Polyvinyl Alcohol (PVA) phantoms has shown that the binary pattern color Doppler method has successfully recovered shear wave velocity map and calculate the elasticity.Clinical Relevance—The result of experiments presents a possibility of using the method for quantitatively access the stage of tissue stiffness related disease.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 3293-3296
Binary Pattern Color Doppler Shear Wave Elastography
Some studies suggested a correlation between tissue elasticity and diseases, such as Adhesive Capsulitis (AC) of the shoulder. One category of method to measure elasticity is by utilizing Doppler imaging. This paper discusses color Doppler shear wave elastography methods and demonstrated an experiment with biological tissue mimicking phantom. A simulation with binary pattern color Doppler shear wave elastography shows that wavelength of a shear wave with suggested magnitude is equal to four multiple of pitch strip in a color flow image. However, the larger amplitude changes the duty ratio and frequency of the pattern. An experiment with biological tissue mimicking Polyvinyl Alcohol (PVA) phantoms has shown that the binary pattern color Doppler method has successfully recovered shear wave velocity map and calculate the elasticity.Clinical Relevance—The result of experiments presents a possibility of using the method for quantitatively access the stage of tissue stiffness related disease.
- Open Access
- 1 October 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2071 (1) , 012034
Large Amplitude Harmonic Vibration under Pulse Doppler Measurement
A flow velocity or tissue motion can be measured by pulse Doppler method. However, when the method is applied to a sinusoid motion or harmonic vibration, the estimation result is deviated. In this paper, the generalized theory of pulse Doppler measurement to the sinusoid motion is explained and the relation between the estimation deviation and the real value is given. Furthermore, a special case of binary velocity estimation is expanded and simulated with different parameters. This simulation result suggested that different selection of parameters may fundamentally affect the output of pulse Doppler estimation.
- 1 October 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2071 (1) , 012034
Open AccessLarge Amplitude Harmonic Vibration under Pulse Doppler Measurement
A flow velocity or tissue motion can be measured by pulse Doppler method. However, when the method is applied to a sinusoid motion or harmonic vibration, the estimation result is deviated. In this paper, the generalized theory of pulse Doppler measurement to the sinusoid motion is explained and the relation between the estimation deviation and the real value is given. Furthermore, a special case of binary velocity estimation is expanded and simulated with different parameters. This simulation result suggested that different selection of parameters may fundamentally affect the output of pulse Doppler estimation.
- 19 March 2021
- Published by Springer Nature
- p. 332-339
Wireless ECG Electrode to Improve Tele-cardiac Monitoring Usability
- 19 March 2021
- Published by Springer Nature
- p. 332-339
Wireless ECG Electrode to Improve Tele-cardiac Monitoring Usability
- Open Access
- 17 October 2018
- Published by Universitas Andalas in JURNAL NASIONAL TEKNIK ELEKTRO
- Vol. 7 (3) , 183-190
Sistem Pelaporan Telecardiac Monitoring Melalui Layanan Pesan Singkat (SMS)
Sistem Pelaporan Telecardiac Monitoring Melalui Layanan Pesan Singkat (SMS)
- 17 October 2018
- Published by Universitas Andalas in JURNAL NASIONAL TEKNIK ELEKTRO
- Vol. 7 (3) , 183-190
Open AccessSistem Pelaporan Telecardiac Monitoring Melalui Layanan Pesan Singkat (SMS)
Sistem Pelaporan Telecardiac Monitoring Melalui Layanan Pesan Singkat (SMS)
- Open Access
- 12 June 2017
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in JAREE (Journal on Advanced Research in Electrical Engineering)
- Vol. 1 (1)
Architecture of RAM-Accumulator based Multichannel Digital PWM
Traditional counter based digital Pulse Width Modulator (PWM) has been a straightforward architecture. However, realization of multichannel PWM with such design requires considerable logic gates. A novel architecture of multichannel PWM based on the usage of RAM block and frequency word accumulator is proposed. This architecture is capable of producing numerous channels while maintaining its performance. The design was tested in Microsemi SmartFusion A2F200 Customizable System on Chip, giving the result of 7.73% FPGA usage to produce 48 channels of 380Hz 16 bits PWM. The output performance for test application is acceptable.
- 12 June 2017
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in JAREE (Journal on Advanced Research in Electrical Engineering)
- Vol. 1 (1)
Open AccessArchitecture of RAM-Accumulator based Multichannel Digital PWM
Traditional counter based digital Pulse Width Modulator (PWM) has been a straightforward architecture. However, realization of multichannel PWM with such design requires considerable logic gates. A novel architecture of multichannel PWM based on the usage of RAM block and frequency word accumulator is proposed. This architecture is capable of producing numerous channels while maintaining its performance. The design was tested in Microsemi SmartFusion A2F200 Customizable System on Chip, giving the result of 7.73% FPGA usage to produce 48 channels of 380Hz 16 bits PWM. The output performance for test application is acceptable.