JRJeff Ross

Jeff Ross

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jeff Ross has a total of 76 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Transplantation of decellularized porcine kidney grafts repopulated with primary human cells demonstrates filtration function in pigs

    by David Y. Lo, Boyukkhanim Ahmadzada, MacKenna A. Stachel, Melia Schaefer, Usman Ashraf, John I. Wagner, Ethan J. Vanderslice, Madie Tornquist, Kendra Mariakis, Peggy Halsten, et al.

    Background End-stage renal disease is a growing global health issue, disproportionately impacting low- and middle-income countries. While kidney transplantation remains the best treatment for end-stage renal disease, access to this treatment modality is limited by chronic donor organ shortages. To address this critical need, we are developing transplantable bioengineered kidney grafts. Methods Podocyte differentiation was achieved in adherent monoculture through Wnt and TGF-β inhibition with IWR-1 and SB431542, respectively. Podocytes along with endothelial cells were then used to recapitulate glomeruli within decellularized porcine kidney scaffolds to generate bioengineered kidneys grafts. These bioengineered kidney grafts were functionally assessed via normothermic perfusion which compared kidney grafts recellularized with only endothelial cells as a control to bi-culture kidney grafts comprised of endothelial cells and podocytes. Heterotopic implantation further tested bi-culture kidney graft function over 3 successive implant sessions with 1–2 grafts per session. Results We demonstrate the ability to source primary human podocytes at scale. Decellularized porcine kidney grafts repopulated with podocytes and endothelial cells exhibit native glomerular structure and display blood filtration capabilities during normothermic perfusion testing. Extending these findings to a clinically relevant model, bioengineered kidneys produce urine with indices of filtration when heterotopically implanted in pigs. Conclusions Our results showcase a human-scale, transplantable bioengineered kidney capable of performing requisite filtration function. This study reinforces the possibility for the bioengineering of transplantable human kidneys, which could someday provide increased and more equitable access to kidney grafts for the treatment of end-stage renal disease.


  • Open Access

    First Application of a Mixed Porcine–Human Repopulated Bioengineered Liver in a Preclinical Model of Post-Resection Liver Failure

    by Philipp Felgendreff, Seyed Mohammad Hosseiniasl, Anna Minshew, Bruce P. Amiot, Silvana Wilken, Boyukkhanim Ahmadzada, Robert C. Huebert, Nidhi Jalan Sakrikar, Noah G. Engles, Peggy Halsten, et al.

    In this study, a mixed porcine–human bioengineered liver (MPH-BEL) was used in a preclinical setup of extracorporeal liver support devices as a treatment for a model of post-resection liver failure (PRLF). The potential for human clinical application is further illustrated by comparing the functional capacity of MPH-BEL grafts as assessed using this porcine PRLF model with fully human (FH-BEL) grafts which were perfused and assessed in vitro. BEL grafts were produced by reseeding liver scaffolds with HUVEC and primary porcine hepatocytes (MPH-BEL) or primary human hepatocytes (FH-BEL). PRLF was induced by performing an 85% liver resection in domestic white pigs and randomized into the following three groups 24 h after resection: standard medical therapy (SMT) alone, SMT + extracorporeal circuit (ECC), and SMT + MPH-BEL. The detoxification and metabolic functions of the MPH-BEL grafts were compared to FH-BEL grafts which were perfused in vitro. During the 24 h treatment interval, INR values normalized within 18 h in the MPH-BEL therapy group and urea synthesis increased as compared to the SMT and SMT + ECC control groups. The MPH-BEL treatment was associated with more rapid decline in hematocrit and platelet count compared to both control groups. Histological analysis demonstrated platelet sequestration in the MPH-BEL grafts, possibly related to immune activation. Significantly higher rates of ammonia clearance and metabolic function were observed in the FH-BEL grafts perfused in vitro than in the MPH-BEL grafts. The MPH-BEL treatment was associated with improved markers of liver function in PRLF. Further improvement in liver function in the BEL grafts was observed by seeding the biomatrix with human hepatocytes. Methods to reduce platelet sequestration within BEL grafts is an area of ongoing research.


  • Open Access

    Xenotransplantation and the Role of the Patient Voice

    by Kevin John Fowler, Vanessa A. Evans, Vineeta Kumar, Jeff Ross

    An abstract is unavailable. This article is available as a PDF only.


  • Open Access

    Manufacturing and Functional Characterization of Bioengineered Liver Grafts for Extracorporeal Liver Assistance in Acute Liver Failure

    by Victoria L. Nelson, Aron R. Stumbras, R. Noelle Palumbo, Shawn A. Riesgraf, Marie S. Balboa, Zachary A. Hannah, Isaac J. Bergstrom, Christopher J. Fecteau, John R. Lake, John J. Barry, et al.

    Acute Liver Failure (ALF) is a life-threatening illness characterized by the rapid onset of abnormal liver biochemistries, coagulopathy, and the development of hepatic encephalopathy. Extracorporeal bioengineered liver (BEL) grafts could offer a bridge therapy to transplant or recovery. The present study describes the manufacture of clinical scale BELs created from decellularized porcine-derived liver extracellular matrix seeded entirely with human cells: human umbilical vein endothelial cells (HUVECs) and primary human liver cells (PHLCs). Decellularized scaffolds seeded entirely with human cells were shown to adhere to stringent sterility and safety guidelines and demonstrated increased functionality when compared to grafts seeded with primary porcine liver cells (PPLCs). BELs with PHLCs were able to clear more ammonia than PPLCs and demonstrated lower perfusion pressures during patency testing. Additionally, to determine the full therapeutic potential of BELs seeded with PHLCs, longer culture periods were assessed to address the logistical constraints associated with manufacturing and transporting a product to a patient. The fully humanized BELs were able to retain their function after cold storage simulating a product transport period. Therefore, this study demonstrates the manufacture of bioengineered liver grafts and their potential in the clinical setting as a treatment for ALF.


  • Open Access

    Sustained in vivo perfusion of a re-endothelialized tissue engineered kidney graft in a human-scale animal model

    by Joseph S. Uzarski, Emily C. Beck, Emily E. Russell, Ethan J. Vanderslice, Matthew L. Holzner, Vikram Wadhera, Dylan Adamson, Ron Shapiro, Dominique S. Davidow, Jeff J. Ross, et al.

    Introduction: Despite progress in whole-organ decellularization and recellularization, maintaining long-term perfusion in vivo remains a hurdle to realizing clinical translation of bioengineered kidney grafts. The objectives for the present study were to define a threshold glucose consumption rate (GCR) that could be used to predict in vivo graft hemocompatibility and utilize this threshold to assess the in vivo performance of clinically relevant decellularized porcine kidney grafts recellularized with human umbilical vein endothelial cells (HUVECs).Materials and methods: Twenty-two porcine kidneys were decellularized and 19 were re-endothelialized using HUVECs. Functional revascularization of control decellularized (n = 3) and re-endothelialized porcine kidneys (n = 16) was tested using an ex vivo porcine blood flow model to define an appropriate metabolic glucose consumption rate (GCR) threshold above which would sustain patent blood flow. Re-endothelialized grafts (n = 9) were then transplanted into immunosuppressed pigs with perfusion measured using angiography post-implant and on days 3 and 7 with 3 native kidneys used as controls. Patent recellularized kidney grafts underwent histological analysis following explant.Results: The glucose consumption rate of recellularized kidney grafts reached a peak of 39.9 ± 9.7 mg/h at 21 ± 5 days, at which point the grafts were determined to have sufficient histological vascular coverage with endothelial cells. Based on these results, a minimum glucose consumption rate threshold of 20 mg/h was set. The revascularized kidneys had a mean perfusion percentage of 87.7% ± 10.3%, 80.9% ± 33.1%, and 68.5% ± 38.6% post-reperfusion on Days 0, 3 and 7, respectively. The 3 native kidneys had a mean post-perfusion percentage of 98.4% ± 1.6%. These results were not statistically significant.Conclusion: This study is the first to demonstrate that human-scale bioengineered porcine kidney grafts developed via perfusion decellularization and subsequent re-endothelialization using HUVEC can maintain patency with consistent blood flow for up to 7 days in vivo. These results lay the foundation for future research to produce human-scale recellularized kidney grafts for transplantation.


  • Open Access

    Sustained In Vivo Perfusion of a Re-Endothelialized Tissue Engineered Kidney Graft in a Human-Scale Animal Model

    by Joseph S. Uzarski, Emily C. Beck, Emily E. Russell, Ethan J. Vanderslice, Matthew L. Holzner, Vikram Wadhera, Dylan Adamson, Ron Shapiro, Dominique S. Davidow, Jeff J. Ross, et al.

    Introduction: Despite progress in whole-organ decellularization and recellularization, maintaining long-term perfusion in vivo remains a hurdle to realizing clinical translation of bioengineered kidney grafts. The objectives for the present study were to define a threshold glucose consumption rate (GCR) that could be used to predict in vivo graft hemocompatibility and utilize this threshold to assess the in vivo performance of clinically relevant decellularized porcine kidney grafts recellularized with human umbilical vein endothelial cells (HUVECs). Materials and Methods: Twenty-two porcine kidneys were decellularized and 19 were re-endothelialized using HUVECs. Functional revascularization of control decellularized (n=3) and re-endothelialized porcine kidneys (n=16) was tested using an ex vivo porcine blood flow model to define an appropriate metabolic glucose consumption rate (GCR) threshold above which would sustain patent blood flow. Re-endothelialized grafts (n=9) were then transplanted into immunosuppressed pigs with perfusion measured using angiography post-implant and on days 3 and 7 with 3 native kidneys used as controls. Patent recellularized kidney grafts underwent histological analysis following explant. Results: The glucose consumption rate of recellularized kidney grafts reached a peak of 41.3±10.2 mg/hour at 21±5 days, at which point the grafts were determined to have sufficient histological vascular coverage with endothelial cells. Based on these results, a minimum glucose consumption rate threshold of 20 mg/hour was set. The revascularized kidneys had a mean perfusion percentage of 87.7±10.3%, 80.9±33.1%, and 68.5±38.6% post-reperfusion on Days 0, 3 and 7, respectively. The 3 native kidneys had a mean post-perfusion percentage of 98.4±1.6%. These results were not statistically significant. Conclusion: This study is the first to demonstrate that human-scale bioengineered porcine kidney grafts developed via perfusion decellularization and subsequent re-endothelialization using HUVEC can maintained patency with consistent blood flow for up to 7 days in vivo . These results lay the foundation for future research to produce human-scale recellularized kidney grafts for transplantation.

  • Open Access

    Author Correction: Functional characterization of a bioengineered liver after heterotopic implantation in pigs

    by Brett D. Anderson, Erek D. Nelson, DongJin Joo, Bruce P. Amiot, Aleksandr A. Katane, Alyssa Mendenhall, Benjamin G. Steiner, Aron R. Stumbras, Victoria L. Nelson, R. Noelle Palumbo, et al.


  • Open Access

    Functional characterization of a bioengineered liver after heterotopic implantation in pigs

    by Brett D. Anderson, Erek D. Nelson, DongJin Joo, Bruce P. Amiot, Aleksandr A. Katane, Alyssa Mendenhall, Benjamin G. Steiner, Aron R. Stumbras, Victoria L. Nelson, R. Noelle Palumbo, et al.

    Organ bioengineering offers a promising solution to the persistent shortage of donor organs. However, the progression of this technology toward clinical use has been hindered by the challenges of reconstituting a functional vascular network, directing the engraftment of specific functional cell types, and defining appropriate culture conditions to concurrently support the health and phenotypic stability of diverse cell lineages. We previously demonstrated the ability to functionally reendothelialize the vasculature of a clinically scaled decellularized liver scaffold with human umbilical vein endothelial cells (HUVECs) and to sustain continuous perfusion in a large animal recovery model. We now report a method for seeding and engrafting primary porcine hepatocytes into a bioengineered liver (BEL) scaffold previously reendothelialized with HUVECs. The resulting BELs were competent for albumin production, ammonia detoxification and urea synthesis, indicating the presence of a functional hepatocyte compartment. BELs additionally slowed ammonia accumulation during in vivo perfusion in a porcine model of surgically induced acute liver failure. Following explant of the graft, BEL parenchyma showed maintenance of canonical endothelial and hepatocyte markers. Taken together, these results support the feasibility of engineering a clinically scaled functional BEL and establish a platform for optimizing the seeding and engraftment of additional liver specific cells.


  • Author Correction: Sustained perfusion of revascularized bioengineered livers heterotopically transplanted into immunosuppressed pigs

    by Mohammed F. Shaheen, Dong Jin Joo, Jeffrey J. Ross, Brett D. Anderson, Harvey S. Chen, Robert C. Huebert, Yi Li, Bruce Amiot, Anne Young, Viviana Zlochiver, et al.

    An amendment to this paper has been published and can be accessed via a link at the top of the paper.


  • Sustained perfusion of revascularized bioengineered livers heterotopically transplanted into immunosuppressed pigs

    by Mohammed F. Shaheen, Dong Jin Joo, Jeffrey J. Ross, Brett D. Anderson, Harvey S. Chen, Robert C. Huebert, Yi Li, Bruce Amiot, Anne Young, Viviana Zlochiver, et al.

    Implanted bioengineered livers have not exceeded three days of continuous perfusion. Here we show that decellularized whole porcine livers revascularized with human umbilical vein endothelial cells and implanted heterotopically into immunosuppressed pigs whose spleens had been removed can sustain perfusion for up to 15 days. We identified peak glucose consumption rate as a main predictor of the patency of the revascularized bioengineered livers (rBELs). Heterotopic implantation of rBELs into pigs in the absence of anticoagulation therapy led to sustained perfusion for three days, followed by a pronounced immune responses directed against the human endothelial cells. A 10 day steroid-based immunosuppression protocol and a splenectomy at the time of rBEL implantation reduced the immune responses and resulted in continuous perfusion of the rBELs for over two weeks. We also show that the human endothelial cells in the perfused rBELs colonize the liver sinusoids and express sinusoidal endothelial markers similar to those in normal liver tissue. Revascularized liver scaffolds that can maintain blood perfusion at physiological pressures might eventually help to overcome the chronic shortage of transplantable human livers.