MKMetin Karayilan

Metin Karayilan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Metin Karayilan has a total of 122 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Injectable Ultrahigh Molecular Weight Fluorescent Copolymers for Bioimaging and Surgical Guidance

    by Yichun Yuan, Sophia Beilharz, Audrey N. Hostetler, Heather R. Everson, Era Srivastava, LeAnne Young, Nehal Nupnar, Oliver B. Giebelhaus, Michael J. A. Hore, Faruk H. ÖrGe, et al.

    Injectable fluorescent polymers can enable real-time surgical guidance and bioimaging, but combining high transparency, low cellular uptake, clinically relevant viscosity, and hydrolytic stability remains challenging. Here, we report ultrahigh molecular weight (UHMW, >106 g mol−1) fluorescent copolymers synthesized by photoiniferter RAFT polymerization as injectable biomaterials for fluorescent ophthalmic viscosurgical devices (OVDs). Simulation results showed that fluorophore-rich segments collapse, promoting aggregation and self-quenching, and identified random monomer distribution with low fluorophore loading as key design criteria. Guided by these insights, N,N-dimethylacrylamide was copolymerized with fluorescein acrylate (0.1−1 mol %) to produce poly(DMA-co-FluA) with molecular weights up to 1.4 MDa and bright green fluorescence under blue illumination. Compared with (meth)acrylate analogues, the acrylamide backbone provided access to UHMW and optical clarity while offering greater intrinsic hydrolytic stability. The 1.4 MDa copolymer matched commercial Healon GV viscosity at ∼30 wt %, exhibited a pronounced frequency-dependent decrease in complex viscosity, reduced HEK293 cellular internalization, and enabled ex vivo porcine-eye OVD visualization and visual assessment of residual material.

  • Open Access

    Predictive framework for degradation-aware plastic classification using spectroscopy and machine learning for proper recycling

    by Dhoopshikha Lakshmi Devi Basgeet, Jaser Hasan, Konpal Raheja, Divita Mathur, Sanmukh Kuppannagari, Metin Karayilan

  • Open Access

    Automation-guided RAFT copolymerization via semi-batch reaction for sequence control

    by Yichun Yuan, Audrey N. Hostetler, Junqi Cui, Nehal Nupnar, Oliver B. Giebelhaus, Md. Bablu Hasan, Michael J. A. Hore, Metin Karayilan

    Sequence control in radical polymerization plays a critical role in defining polymer properties, yet achieving such control typically relies on high-cost automated platforms with limited accessibility. Here, we present a semi-batch reversible addition-fragmentation chain transfer (RAFT) copolymerization strategy using a syringe pump as a low-cost and modular alternative to high-end robotic systems. Using the copolymerization of oligo(ethylene glycol) methyl ether acrylate and fluorescein o -acrylate as a model system, we directly benchmark this approach against previously reported Chemspeed-enabled workflows. The results highlight that syringe pump-based semi-batch systems can offer a practical and accessible alternative to fully automated platforms.


  • Open Access

    Thermoresponsive Fluorescent Polymers: Influence of Size, Composition, and Architecture

    by Konpal Raheja, Sophia Beilharz, Ajitesh Lalam, Md Bablu Hasan, Divita Mathur, Metin Karayilan

    Thermoresponsive fluorescent polymers (TFPs) provide a versatile platform for optical temperature sensing by coupling phase transitions with changes in fluorescence. Here, we report TFPs based on poly(N-isopropylacrylamide) (PNIPAM) and poly(ethylene glycol methacrylate) (PEGMA), incorporating fluorescein acrylate (FluA) as a model fluorophore via reversible addition-fragmentation chain transfer (RAFT) copolymerization. Linear and hyperbranched architectures were synthesized, with different compositions to position cloud point temperatures (Tcp) within a physiologically relevant temperature window, and their fluorescence behavior was investigated as a function of temperature, concentration, and pH. Distinct responses were observed across the Tcp, governed by the interplay between polymer collapse, microenvironmental confinement, and chromophore-chromophore interactions. Systems with low fluorescein loading exhibited fluorescence enhancement near the Tcp followed by quenching at higher temperatures, whereas higher loading systems showed predominantly decreased fluorescence intensity upon heating. Because all samples were compared at equal mass concentration, raw emission intensity scaled primarily with fluorophore loading per chain; we therefore interpret intensity differences cautiously and emphasize the temperature-dependent response as the diagnostic readout. Fluorescence intensity was strongly concentration-dependent, and pH studies revealed changes in both fluorescence intensity and emission maxima, with temperature-responsive fluorescence most prominent at pH 7 and moderately retained at pH 9. Rheological measurements further demonstrated changes in complex viscosity across the Tcp, linking macroscopic behavior to structural transitions. Hyperbranched polymers displayed responses distinct from their linear analogues. We summarize these observations as a set of provisional design rules that link each structural variable, such as composition, fluorophore loading, and architecture, to its dominant effect on Tcp, fluorescence, and viscosity. We note that several of these variables co-vary across the present sample set. Trends are therefore interpreted within controlled compositional windows rather than as fully orthogonal factors, and the resulting rules are intended as practical guidelines for designing polymer-based optical thermometers.


  • Open Access

    Ultrahigh Molecular Weight Fluorescent Copolymers as Injectable Biomaterials

    by Yichun Yuan, Sophia Beilharz, Audrey Hostetler, Heather R. Everson, Era Srivastava, LeAnne Young, Nehal Nupnar, Oliver B. Giebelhaus, Michael J. A. Hore, Faruk H. Örge, et al.

    Injectable fluorescent polymers enable real-time surgical guidance and bioimaging, but simultaneously achieving high transparency, low cellular uptake, clinically practical viscosity, and long-term hydrolytic stability remains challenging. We report ultrahigh molecular weight (UHMW, > 106 g mol-1) fluorescent copolymers synthesized by photoiniferter reversible addition-fragmentation chain-transfer (RAFT) polymerization as injectable biomaterials, with a focus on fluorescent ophthalmic viscosurgical devices (OVDs). Dissipative particle dynamics (eDPD) simulations of diblock and random architectures revealed that fluorophore-rich segments collapse and drive aggregation and self-quenching, identifying random monomer distribution and low fluorophore loading as key design levers. Guided by these simulations, N,N-dimethylacrylamide (DMA) was copolymerized with fluorescein acrylate (FluA) at low loading (0.1–1 mol%) to yield poly(DMA-co-FluA) with molecular weights from ∼50 kDa to 1.4 MDa and bright green fluorescence under blue illumination. Comparison with (meth)acrylate analogues (OEGA, CEA, DMAEMA) showed that the acrylamide backbone uniquely combines hydrolytic stability, optical clarity, and access to UHMW. The 1.4 MDa copolymer matched commercial Healon GV viscosity at ∼30 wt%, retained shear-thinning injectability, and exhibited markedly lower HEK293 cellular internalization than the 50 kDa analogue while preserving viability. Ex vivo porcine-eye cataract surgery confirmed intraoperative visualization under cobalt-blue light, enabling OVD removal verification.

  • Open Access

    Accessible Automation-Inspired RAFT Copolymerization for Sequence-Controlled Polymer Design

    by Yichun Yuan, Audrey N. Hostetler, Junqi Cui, Nehal Nupnar, Oliver B. Giebelhaus, Michael J. A. Hore, Metin Karayilan

    Sequence control in radical polymerization plays a critical role in defining polymer properties, yet achieving such control typically relies on high-cost automated platforms with limited accessibility. Here, we present a semi-batch reversible addition-fragmentation chain transfer (RAFT) copolymerization strategy using a syringe pump as a low-cost and modular alternative to high-end robotic systems. Using the copolymerization of oligo(ethylene glycol) methyl ether acrylate and fluorescein o-acrylate as a model system, we directly benchmark this approach against previously reported Chemspeed-enabled workflows. The results highlight that syringe pump-based semi-batch systems can offer a practical and accessible alternative to fully automated platforms.

  • Open Access

    Degradation-Aware Plastic Sorting Using Spectroscopy, Barcode Additives, and Deep Learning

    by Dhoopshikha Basgeet, Jaser Hasan, Konpal Raheja, Divita Mathur, Sanmukh Kuppannagari, Metin Karayilan

    Plastics undergo complex degradation processes that signiQicantly inQluence their recyclability, performance, and value in circular materials systems. However, traditional sorting practices classify plastics solely by polymer type (e.g., polypropylene, PP; poly(ethylene terephthalate), PET), ignoring their degree of degradation (i.e., age, conditions), and resulting in post-consumer recycled (PCR) materials (i.e., downcycling) with reduced material quality. This work presents a predictive, nondestructive framework for determining the age of plastics using vibrational spectroscopy, machine learning, and a forward-looking additive-based strategy. Mild thermal aging experiments on commercial PET (at 50 °C for two weeks) revealed no measurable chemical or structural changes in FTIR spectra and no signiQicant mass loss in thermogravimetric analysis (TGA), demonstrating the insensitivity of conventional methods to early-stage degradation. In contrast, Raman spectroscopy data collected from the literature combined with deep learning enabled robust classiQication of aged versus unaged materials. Two architectures were evaluated, namely Figure2CNN and ResNet1D, achieving mean accuracies of 90.16% ± 4.50% and 89.61% ± 2.27%, respectively, with Figure2CNN achieving higher overall accuracy and ResNet1D exhibiting lower variance across folds. However, per-sample evaluation revealed that ResNet1D exhibited complete majority-class collapse, correctly classifying zero stable samples across all folds, while Figure2CNN demonstrated balanced discrimination across both classes and is therefore the recommended architecture for this task. To promote practical deployment, an interactive inference dashboard was developed that performs real-time preprocessing and classiQication of Raman spectral data. Finally, a forward-looking additive-based "age barcode" approach using triazole-derived UV absorber additives is proposed to enhance sensitivity and interpretability of degradation detection. This integrated framework combines spectroscopy, advanced computation, and chemical design to offer the potential for accurate, scalable aging assessment for improved plastic recycling.

  • Open Access

    Structure–Property Relationships in Thermoresponsive Fluorescent Polymers: Roles of Size, Composition, and Architecture

    by Konpal Raheja, Sophia Beilharz, Ajitesh Lalam, Bablu Hasan, Divita Mathur, Metin Karayilan

    Thermoresponsive fluorescent polymers (TFPs) provide a versatile platform for optical temperature sensing by coupling phase transitions with changes in fluorescence. Here, we report TFPs based on poly(N-isopropylacrylamide) (PNIPAM) and poly(ethylene glycol methacrylate) (PEGMA), incorporating fluorescein acrylate (FluA) as a model fluorophore via reversible additionfragmentation chain transfer (RAFT) copolymerization. Linear and hyperbranched architectures were synthesized, with different compositions to exhibit cloud point temperatures (Tcp) within a physiologically relevant temperature window. Fluorescence behavior was investigated as a function of temperature, concentration, and pH. Distinct responses were observed across the Tcp, governed by the interplay between polymer collapse, microenvironmental confinement, and chromophorechromophore interactions. PNIPAM and PEGMA systems containing low fluorescein loading exhibited fluorescence enhancement near the Tcp, followed by quenching at higher temperatures, whereas higher loading systems showed predominantly decreased fluorescence intensity upon heating due to increased chromophore-chromophore interactions. Fluorescence intensity was strongly concentration-dependent, highlighting the role of aggregation, and pH studies revealed changes in both fluorescence intensity and emission maxima, with temperature-responsive fluorescence being most prominent at pH 7 and moderately retained at pH 9. Rheological measurements further demonstrated changes in complex viscosity across the Tcp, linking macroscopic behavior to structural transitions. Hyperbranched polymers exhibited distinct fluorescence and rheological responses compared to linear analogues, underscoring the influence of topology. These results establish structure-property relationships that enable tunable fluorescence responses, providing design guidelines for polymer-based optical thermometers.

  • Open Access

    Structure–Property Relationships in Thermoresponsive Fluorescent Polymers: Roles of Size, Composition, and Architecture

    by Konpal Raheja, Sophia Beilharz, Ajitesh Lalam, Hasan, Divita Mathur, Metin Karayilan

    Thermoresponsive fluorescent polymers (TFPs) provide a versatile platform for optical temperature sensing by coupling phase transitions with changes in fluorescence. Here, we report TFPs based on poly(N-isopropylacrylamide) (PNIPAM) and poly(ethylene glycol methacrylate) (PEGMA), incorporating fluorescein acrylate (FluA) as a model fluorophore via reversible additionfragmentation chain transfer (RAFT) copolymerization. Linear and hyperbranched architectures were synthesized, with different compositions to exhibit cloud point temperatures (Tcp) within a physiologically relevant temperature window. Fluorescence behavior was investigated as a function of temperature, concentration, and pH. Distinct responses were observed across the Tcp, governed by the interplay between polymer collapse, microenvironmental confinement, and chromophorechromophore interactions. PNIPAM and PEGMA systems containing low fluorescein loading exhibited fluorescence enhancement near the Tcp, followed by quenching at higher temperatures, whereas higher loading systems showed predominantly decreased fluorescence intensity upon heating due to increased chromophore-chromophore interactions. Fluorescence intensity was strongly concentration-dependent, highlighting the role of aggregation, and pH studies revealed changes in both fluorescence intensity and emission maxima, with temperature-responsive fluorescence being most prominent at pH 7 and moderately retained at pH 9. Rheological measurements further demonstrated changes in complex viscosity across the Tcp, linking macroscopic behavior to structural transitions. Hyperbranched polymers exhibited distinct fluorescence and rheological responses compared to linear analogues, underscoring the influence of topology. These results establish structure-property relationships that enable tunable fluorescence responses, providing design guidelines for polymer-based optical thermometers.

  • Open Access

    Cultivating Safety Culture through Peer-Led Safety Minute Slides and Videos in Chemistry Research Environments

    by Griffin Pardo, Aaryan Patel, Konpal Raheja, Maryam Behzad Khoshgoee, Md Bablu Hasan, Audrey N. Hostetler, Yichun Yuan, Metin Karayilan