AVAleksandr Yu. Vaza

Aleksandr Yu. Vaza

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aleksandr Yu. Vaza has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Finger bowstringing contracture correction in cases after flexor tendons laceration treatment

    by Irina Yu. Miguleva, Aleksandr Yu. Vaza, Alexey M. Fain, Файн Алексей Максимович

    INTRODUCTION: The problems of bowstringing deformity management strategies in cases after flexor tendon surgery are not often if ever discussed in Russian-language medical literature. CASES DESCRIPTION: Our experience comprises 25 patients to whom bowstringing deformity correction was carried out in 29 digits. Our findings at surgery and flexor tendon bed exploration let us to point out the two types of bowstringing deformity: with additional loss of extension from iatrogenic longitudinal scar shortening in 22 of our 29 cases (76%) and with no pathology of the skin as 7 cases of 29 (24%) exhibited. In most cases, flexor tendons were found embedded in the skin velum, sutured over intact pulleys; exploration confirmed anatomical integrity of the A2 pulley, despite complete collapse of the underlying canal opening. The developed surgical strategy was based on a staged treatment principle. Correction of cicatricial deformity of the palmar skin was performed as the first stage, after that the two-stage deep flexor tendon grafting procedure was performed with silicone implant insertion initially. In cases of long-standing arthrogenic contractures, external fixation devise at separate stage was mounted and graduated distraction was performed in 2 of 29 fingers (7%). In the course of silicone rod insertion procedure, we succeeded in preserving of the intact A2 and A4 in all cases owing to author-developed pulley transverse cutting in parts technique. Reconstruction of previously damaged A2 pulley was required in 4 cases. Pulley reconstruction was performed using the technique described by Okutsu et al. (1987) and Dy, Daluiski (2013), with a minor modification. CONCLUSION: The outcomes of patients' treatment and results of bowstringing deformity correction are indicative of the developed surgical treatment protocol effectiveness. Bowstringing deformity responsible not only for the grip loss but also for cosmetic implication was corrected completely with no recurrence tendency in all 29 cases. Out of 23 cases, full finger motion was restored in 1 case (4.5%), good functional recovery in 15 cases (65%) was achieved, and fair recovery in 7 cases (30.5%). In 6 cases, patients declined tendon grafting.

  • Assessment of using thread joysticks results for fragment reduction and bone allografting in the treatment of bone defects in patients with proximal humeral fractures

    by R. S. Titov, A. M. Fain, A. Yu. Vaza, N. V. Borovkova, S. F. Gnetetskiy, I. I. Mazhorova, K. A. Rozhkov, K. I. Skuratovskaya

    Introduction Despite significant advances in the development of new fixation systems and improvements in surgical technologies, algorithms that guarantee anatomical reduction in proximal humerus fractures are lacking.The aim of this study was to evaluate the clinical efficacy of using thread joysticks for fragment reduction and allogeneic bone grafting materials to repair bone defects in patients with proximal humerus fractures. Material and methods A total of 219 patients with proximal humerus fractures were treated. The main group consisted of 123 patients and was treated according to the proposed by us osteosynthesis, while the comparison group included 96 patients was managed with traditional methods. Long-term outcomes were assessed at 1 to 4 years postoperatively using the Constant score, as well as two questionnaires: the Simple Shoulder Test (SST) and the Oxford Shoulder Score (OSS). Results In the main group, the Constant score ranged from a maximum of 98 to a minimum of 6, with a mean of 69.8 and a median of 73. In the control group, the maximum score was 93, the minimum was 8, with a mean and median of 54. Poor results were observed in 9 patients (7.3 %) in the main group. Of these, 4 (3.3 %) were due to infection, 3 (2.4 %) to implant migration, and 2 (1.6 %) to poor compliance with rehabilitation, leading to shoulder joint contracture. In the comparison group, 32 patients (33.3 %) had poor outcomes. Among them, 15 (15.6 %) had persistent limitations in abduction and internal rotation, 10 (10.4 %) exhibited implant migration, 5 (5.2 %) developed infection requiring reoperation, and 2 (2.1 %) experienced severe post‑traumatic arthritis and humeral head collapse. Discussion The described technique has a number of advantages compared toexisting methods, which allows for stable fixation in cases of 3- and 4-part fractures and avoids the need for shoulder joint replacement. It features a clearly defined algorithm of procedures that simplifies the reduction and fixation of bone fragments, especially in defects of the proximal humerus. Conclusion The application of this surgical technique reduced operative time and improved treatment outcomes in fractures of the proximal humerus.

  • Open Access

    Optimization of allogeneic bone graft properties

    by Alexandr Yu. Vaza, Alexey M. Fain, Olga A. Zabavskaya, Natalya V. Borovkova, Kristina I. Skuratovskaya, Elena A. Zhirkova, Roman S. Titov, Файн Алексей Максимович

    BACKGROUND: Various biological and non-biological materials are used to repair bone defects resulting from trauma. At the N.V. Sklifosovsky Research Institute for Emergency Medicine, allogeneic bone is routinely applied for bone grafting in intra-articular fractures. However, if a particular graft demonstrates weak osteoconductive properties, cyst formation may occur at the graft site, compromising bone quality. To prevent such complications, we developed a composite allogeneic bone–collagen lyophilized graft. AIM: This study aimed to determine the optimal graft for the repair of traumatic cancellous bone defects by comparing the regenerative properties of allogeneic bone grafts and composite allogeneic bone–collagen grafts. METHODS: A prospective randomized study was conducted with two patient groups. In group 1 (n = 34), osteosynthesis was performed using a cortical block of non-demineralized lyophilized allogeneic bone. In group 2 (n = 34), bone grafting was performed using an allogeneic perforated bone–collagen lyophilized block graft. All patients underwent computed tomography at admission, immediately after grafting, at 1.5 months, and at 6 and 12 months postoperatively. Bone tissue quality and osteointegration were assessed based on 12-month computed tomography data. RESULTS: Significantly higher bone tissue quality was observed in group 2 (82%). No patients in group 2 demonstrated the lowest bone quality grade (grade IV), whereas in group 1 grade IV was observed in six cases, two of which had cystic cavities and bone voids occupying more than 50% of the condylar volume. Adequate osteointegration at 12 months was documented in 16 patients (47%) in group 1 and in 27 patients (79%) in group 2, with a statistically significant difference (p = 0.006; probability calculator). In group 1, grade II–III osteointegration was observed in only 16 patients (47%), whereas in group 2 it was recorded in 27 patients (79%), a statistically significantly higher proportion (p = 0.006; probability calculator). CONCLUSION: Objective, statistically validated data confirm regeneration of bone tissue in traumatic defects of the lateral tibial condyle. Analysis demonstrates that the regenerative potential of the composite bone–collagen graft is superior to that of the allogeneic bone graft lacking collagen.

  • Open Access

    Clinical efficacy of injectable autologous platelet preparations in patients after arthroscopic repair of the anterior cruciate ligament

    by A. A. Budaev, M. S. Makarov, N. V. Borovkova, A. M. Fain, K. I. Skuratovskaya, M. V. Storozheva, A. Yu. Vaza, I. I. Mazhorova

    Background. Platelet-rich plasma (PRP) can be used in the treatment of knee joint defects, including relief of complications in the early postoperative period after arthroscopic repair of the anterior cruciate ligament. Low-pulse laser radiation (LPLR) with wavelength 635 nm stimulates the platelet activity in PRP and increases their realization of reparative potential.Objective. To evaluate the clinical effect of injectable autologous platelet preparations in patients in the early postoperative period after arthroscopic repair of the anterior cruciate ligament.Material and methods. The study included 45 patients, who underwent arthroscopic prosthetics of the anterior cruciate ligament or its fixation to the place of attachment. The patients were divided into 3 groups: in the 1st group (15 people) the operation was performed without using platelet preparations (the comparison group); in the 2nd group (15 people), non-activated autologous PRP was intraoperatively administered; in the 3rd group (15 people), LPLR-activated autologous PRP was intraoperatively administered. The PRP was exposed to LPLR with wavelength 635 nm and power 2 W for 10 minutes. Two ml of the autologous platelet-rich preparation were injected intra-articularly; additionally 1 ml of the same preparation was applied in a fan-like pattern to the surrounding soft tissues.Results. After surgery patients in comparison group had moderate acute pain syndrome, while patients in main groups did not complain about severe pain in the area of surgery. The use of autologous PRP-preparations significantly reduced pain assessments by Visual Analogue Scale by 1.5 times in the 2nd group and 3 times in the 3rd group, comparing to patients without PRP treatment (pConclusions. Intra- and periarticular administration of non-activated and LPLR-activated PRP allowed to reduce pain and the incidence of hemarthrosis after knee surgery. The use of LPLR-activated PRP demonstrates more pronounced anti-inflammatory and hemostatic effects comparing to non-activated PRP.

  • Open Access

    Efficacy of using platelet rich plasma lysate in treatment patients with proximal humerus fracture

    by R. S. Titov, A. M. Fayn, I. N. Ponomarev, N. V. Borovkova, I. I. Mazhorova, L. T. Khamidova, P. G. Evgrafov, A. Yu. Vaza, K. I. Skuratovskaya

    Relevance. Proximal humerus fractures account for up to 75 % of all humerus fractures in patients over 60 years of age. The number of such patients is constantly growing, but there is no consensus on the treatment of this injury.Target. To determine the effectiveness of using platelet-rich lysate in patients with proximal humerus fractures.Object and methods. A randomized prospective study was conducted. All operated patients (n = 34) were divided into 3 groups. The first group (main 1) included patients who were administered platelet-rich plasma lysate at the end of surgery – 13 patients. The second (main 2) included patients who used platelet-rich plasma on the 14th day from the moment of surgery. The third (comparison group) included patients who didn`t use platelet-rich plasma lysate. To objectify the effect of platelet-rich plasma used the ultrasound method of research.Results. An intergroup comparison at different times after surgery showed that in the Main 1 group, in which PRP was started intraoperatively, the relative thickness of the supraspinatus muscle on the side of the operation was significantly lower than in other groups. In a pairwise comparison in the group of patients without PRP and in patients of the 2nd main group (who were administered PRP n the 14th day), the relative thickness of the supraspinatus muscle on the side of surgery after 1 month and after 1,5–2,5 months didn`t differ significantly from surgery.Conclusions. Intraoperative use of platelet-rich plasma can reduce inflammatory changes in the tendons of the supraspinatus and subscapularis muscles, which is reliably confirmed by ultrasound data.


  • Open Access

    Comparative analysis of the integration of autologous and allogeneic cryopreserved tendons in the femoral canal on a model of laboratory animals

    by A. A. Budaev, N. S. Tropskaya, N. V. Borovkova, A. M. Fayn, G. P. Titova, M. S. Makarov, A. Yu. Vaza, I. V. Ponomarev, E. A. Kislyakova, O. S. Kislitsyna, et al.

    Allogeneic tendon grafts are seriously demand in knee joint plastic surgery. The novel method of tendon cryopreservation, including sterilization with supercritical carbon dioxide, was developed in N.V. Sklifosovsky Research Institute for Emergency Cryopreserved tendons retain their normal fiber structure without significant loss of mechanical properties. At the next stage it was necessary to evaluate cryopreserved tendons′ integration inside bone canal in experimental animals.The aim of study. To evaluate morphologic changes of autologous and allogeneic tendons inside the femur in rats and to determine the effect of tendon transplantation on the physical activity.Material and methods. The study was conducted on white inbreed male rats. Three groups of animals were formed: the control group (animals without tendon transplantation), the 1st experimental group – animals with autologous tendon transplantation, the 2nd experimental group – animals with allogeneic tendon transplantation. In animals of the experimental groups the through channel was formed in the distal metaepiphysis of the femur and a tail tendon graft 0.5 x 0.1 cm was placed there. To assess the physical activity of the animals, we studied maximum distance that the animals could run 3 and 6 weeks after transplantation was determined, using treadmill test. The graft structure was evaluated on histological preparations in transmitted light, stained with hematoxylin-eosin and Van Gieson′s stain. To assess the preservation of collagen fibers we checked the autofluorescence intensity of collagen.Results. According to the treadmill test, the distance run by the animals of both experimental groups did not significantly differ from the values in the control group. Histological analysis after 3 weeks in both experimental groups revealed signs of fibers′ decomposition in the absence of inflammatory infiltration and maintaining close contact with bone trabeculae. The autofluorescence intensity of the collagen fibers in grafts corresponded to normal or was close to normal. After 6 weeks, the animals of both experimental groups revealed areas of graft fusion with their own bone, Sharpe fibers were actively formed. In both groups, numerous small vessels with diameters up to 10 microns were detected in the area of tendon-bone contact. Infiltration of grafts by inflammatory cells was absent or very insignificant, active migration of fibroblasts to the tendon area was also not observed. In both groups, tendon grafts had areas where fiber decompactization was observed. In the area of contact with the bone, the autofluorescence of tendon fibers was sharply increased, which indicates the chemical cleavage of collagen. At 3 and 6 weeks after transplantation the effect of fixation (integration) of the tendon with bone tissue was observed in both experimental groups.Conclusions. Allogeneic tendon grafts did not cause a pronounced inflammatory or immune reaction in experimental animals. 6 weeks after transplantation of autologous and allogeneic tendons, the integration of grafts inside the femoral canal was observed. Cryopreserved allogeneic tendons were able to integrate into the body's own tissues without pronounced structural and functional disorders. According to the treadmill test, the distance covered by the animals of both experimental groups did not differ statistically significantly from the values in the control group (without tendon transplantation) after 3 and 6 weeks

  • Open Access

    Evaluation of the effectiveness of allogeneic tendon graft sterilization with supercritical carbon dioxide

    by A. A. Budaev, N. V. Borovkova, A. M. Fayn, A. Yu. Nikolaev, M. S. Makarov, M. V. Storozheva, K. I. Skuratovskaya, A. Yu. Vaza, I. V. Fomicheva, T. V. Chernen'KAya, et al.

    Structural and functional properties of the human tendon tissue complicate process of tendon-based grafts preserving. In the process of preservation, it is necessary to maintain mechanical and functional parameters of the tendon tissue as well as to provide sterility and biological safety of the graft. One could conclude effectiveness of techniques, combining tendon conservation at low temperatures and sterilization with the supercritical carbon dioxide.Aim of work: to find optimal conditions for allogeneic tendon grafts sterilization with supercritical carbon dioxide.Materials and methods. Allogeneic tendons were prepared from the tissue donors, following the rules of asepsis and antisepsis. After quarantine and confirmation of the absence of blood-borne infections the tendon grafts were divided into 3 groups: in the control group the tendons were not subjected to cryopreservation and sterilization procedures; in 2 experimental groups tendons were treated with a cryoprotector 10 % dimethyl sulfoxide (DMSO) solution and sterilized with supercritical carbon dioxide with slow gas discharge (group 2) or with fast gas discharge (group 3); the duration of sterilization in both groups varied from 1 to 12 hours. The toxicity of the grafts was assessed in human mesenchymal multipotent stromal cells (MMSC) culture on the 3rd and 7th days. The sterility of the grafts was confirmed on the 7th and 14th day by bacteriological culture on thioglycol medium and Saburo broth. Mechanical tests were performed on testing machine LLOYD Instruments LR5K Plus with the tensile speed 5 mm/min.Results. Histological analysis showed, that in the group with slow gas discharge collagen fibers retained their integrity and topography and contained only local minor tears; in all terms of treatment, the tendon grafts were sterile and nontoxic. On the contrary, in the group with fast gas discharge there was marked damage of the collagen fibers and growth of bacterial and fungal flora was observed in the culture. The grafts of the control group and the group, where sterilization with supercritical carbon dioxide was performed with slow gas discharge for 1-12 hours, were used to evaluate mechanical characteristics. In the preserved tendons the stiffness and ultimate strain did not significantly differ from the similar values in the control (p > 0.05), on the contrary, the level of ultimate strain in all experimental specimens was significantly reduced by 1.5-2.1 times comparing to the control. Young's modulus and load at rupture in the control grafts and grafts, sterilized for 1 hour, had similar values, whereas in grafts, sterilized from 3 to 12 hours, these parameters were 1.4-2.1 times lower (p < 0.05).Conclusions. The suggested technique of tendon preservation, using cryoprotector DMSO and sterilization with the supercritical carbon dioxide, allows to obtain sterile and non-toxic grafts. The structure of cells and fibers of the preserved tendons did not significantly disturbed. For supercritical carbon dioxide sterilization of tendon grafts the most optimal processing time is 1 hour.


  • Reconstruction of the anterior cruciate ligament with cryopreserved allogeneous anterior tibia tendon graft

    by A.A. Budaev, V.B. Bondarev, N.V. Borovkova, A.M. Fine, M.S. Makarov, A.YU. Vaza, O.L. Evdokimova, M.V. Neznanova, M.V. Storozheva, A.S. Mironov, et al.

    Aim of study. To evaluate the effectiveness of allogeneic tendon, sterilized with supercritical carbon dioxide, in restoration of the anterior cruciate ligament (ACL) during clinical example. Material and methods. The patient was admitted at the N.V. Sklifosovsky Research Institute for Emergency Medicine with the diagnosis: an old rupture of the anterior cruciate ligament of the right knee joint, rupture of the internal meniscus, chondromalacia of the inner condyle of the right femur 2-3 art., according to the ICRS classification. From the anamnesis, it became known about the previous 2 operations for ruptures of the ligaments of the right knee joint and the use of autologous tendons as a plastic material. A conversation was held with the patient about all possible methods of ACL repair and a choice was made in favor of using a cryopreserved allogeneic tibialis anterior tendon graft as a graft due to a shortage of autologous tissues. Allogeneic tendons were taken from tissue donors, treated with 10% dimethyl sulfoxide, sterilized with supercritical carbon dioxide and frozen at -80°C. After confirming the absence of toxicity, as well as the results of bacteriological examination, the allogeneic tendon graft was used for ACL repair. Results. The early postoperative period was uneventful. On the 12th day postoperative wounds healed by primary intention. An MRI examination revealed a graft of the anterior cruciate ligament in the formed bone canals; the graft was not thickened and had a homogeneous structure. After 28 days, the patient gradually began active and passive development of movements in the knee joint. After 6 weeks the range of motion and strength in the right knee joint was comparable to the left knee joint. After 4 months, according to magnetic resonance imaging, ligamentation of the allogenic graft and "synovial sleeve" formation were observed. Conclusion. According to the clinical course and time of rehabilitation, the technique of using allogeneic tendons during ACL plastic surgery was comparable to the use of an autologous graft. The clinical experience of using allogeneic tendons at the early postoperative stage could be assessed as successful. Further observation is necessary to fully assess the reconstruction and integration of the tendon. Keywords: anterior cruciate ligament, arthroscopic repair, graft, tendons, allogeneic, sterilization.

  • Open Access

    Surgical treatment of proximal humerus fractures with using the original allogeneic fibula graft: retrospective cohort study

    by Aleksandr Yu. Vaza, Aleksey M. Fain, Kristina I. Skuratovskaya, Roman S. Titov, Natalya V. Borovkova, Sergey F. Gnetetskiy, Faat A.-K. Sharifullin, Anton A. Fain, Файн Алексей Максимович, Гнетецкий Сергей Феликсович

    BACKGROUND: A proximal humerus fracture (PHF) is quite common and accounts for approximately 5% of all fractures. During surgery, these fractures make it difficult to correctly reattach the bone fragments. Various special techniques are needed for repositioning and stable fixation of the fragments. When considering the most effective ways to facilitate fracture repositioning and prevent secondary displacement, we paid attention to the publications on the use of the fibula graft. AIM: To evaluate the effectiveness of a new allogeneic bone-collagen graft from the fibula head in PHF osteosynthesis with a plate having angular stability in conditions of bone tissue deficit. MATERIALS AND METHODS: An original bone-collagen allogeneic graft from the proximal part of the fibula was developed. We carried out a comparative analysis of the treatment results in patients operated on using the fibula head allograft (group O 48 patients, subgroup O1 - 35 patients; period - not less than 1 year after surgery) and the group without using augmentation graft (group K 32 patients). The results were assessed using clinical, radiological, and standardized Constant Shoulder Score; the statistical analysis was also performed. RESULTS: No patient in group O developed secondary dislocation, while in group K it was noted in 5 (16%) patients. Head collapse developed in 3 patients (7%) in group O and 8 (25%) in group K. Surgery time was shorter in group O than in group K. The mean Constant Scholder Score in subgroup O1 was 78 and in group K 70. Thinning in the cortical layer of the graft and the border disappearance between the spongy part of the graft and the bone tissue of the humeral head were noted in all patients during multispiral CT scanning over time, which was considered a sign of graft remodeling and lysis. CONCLUSION: In severe PHF with bone deficit, it is possible to perform organ preseration surgery regardless of the patients age and obtain functional results satisfying both the patient and the physician. Our suggested method of severe PHF surgical treatment combined with bone deficit facilitates repositioning, reduces operation time, and decreases the number of complications.

  • Open Access

    Available methods to enhance regenerative potential of plastic materials for bone defects replacement in orthopedics. Part 3. Use of autologous human red bone marrow

    by A. M. Fain, A. Yu. Vaza, S. F. Gnetetskiy, K. I. Skuratovskaya, V. B. Bondarev, Yu. A. Bogolyubskiy, R. S. Titov, A. Yu. Sergeev, Ю. А. Боголюбский

    The previous two articles described the use of platelet-rich plasma and platelet lysate. This part of the literature review examines the mechanism of red bone marrow action, indications and contraindications for its use. The results of treatment for delayed consolidation of bone fractures are also described. Hematopoietic stem cells give rise to all cellular components of the circulating blood, such as red blood cells, lymphocytes, neutrophils, and platelets. The most rational way to stimulate bone regeneration is to use the patient's own biological material. The aim of this article is to summarize the results of treatment using autologus bone marrow to improve bone regenerative potential in orthopaedics.