Dong-In Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dong-In Shin has a total of 218 co-authors. Here are the top co-authors by number of shared publications:
- Christian Blockhaus
Heart Centre Niederrhein, Department of Cardiology, Helios Clinic Krefeld, 47805 Krefeld, Germany
5 shared publications - Anja Schade
Department of Interventional Electrophysiology, Helios Hospital Erfurt , Nordhäuser Strasse 74, 99089 Erfurt
4 shared publications Carsten Wunderlich
Helios Klinikum Pirna, Klinik für Innere Medizin II , Struppener Strasse 13, 01796 Pirna
4 shared publications- Christian Sohns
Department of Electrophysiology, Heart and Diabetes Center NRW Ruhr University Bochum Bad Oeynhausen Germany
4 shared publications - Christian-Hendrik Heeger
Department of Rhythmology, Cardiology and Internal Medicine, Asklepios Klinik Hamburg Altona , Hamburg
4 shared publications - Philipp Sommer
Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-University Bochum , Bad Oeynhausen
4 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 6 (5)
Sex-based differences in the management and outcomes of oesophageal fistula following atrial fibrillation ablation: a subanalysis of the worldwide POTTER-AF study
Aims: Oesophageal fistula (OF) is a rare but life-threatening complication of atrial fibrillation (AF) ablation. Data on sex-related differences in its management and outcomes are limited. Methods and results: The PrOgnosis following oesophageal fisTula formaTion in patients undergoing cathetER ablation for AF study is a global, multicentre study evaluating the incidence, management, and outcome of OF following AF ablation. Among 553 729 patients treated across 214 centres in 35 countries between 1996 and 2022, 138 developed OF. Sex-specific data on management and outcome were available in 117 cases and are analysed herein. Females comprised 47% of the analysed cohort. Baseline characteristics, ablation modality, and use of oesophageal temperature monitoring were not different between sexes in patients developing OF. Fewer women received proton pump inhibitors post-procedure (64.8% vs. 84.7%; P = 0.017). Among patients with OF, less women developed atrio-OF (90.9% vs. 100%; P = 0.021). Oesophageal perforation and oesophageal–pericardial fistula occurred exclusively in females. The median duration until symptoms onset was 20 days for women and 16.5 days for men (P = 0.14). Echocardiography was more frequently used in women (36.4% vs. 15%; P = 0.01). Stroke was more common in women (32.7% vs. 14.8%; P = 0.040), however only before adjusting for potential cofounders. Other complications were comparable. Women underwent endoscopic therapy more often (35.8% vs. 17.7%; P = 0.034) and surgical treatment alone less frequently (28.3% vs. 51.6%; P = 0.014). Fatality rates were high and not different (63.6% in women vs. 67.2% in men; P = 0.70). Conclusion: While OF incidence for each sex could not be calculated, nearly half of all patients with OF were female. Women underwent more often endoscopic and less often surgical interventions; outcomes were comparable.
- 1 September 2026
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 6 (5)
Open AccessSex-based differences in the management and outcomes of oesophageal fistula following atrial fibrillation ablation: a subanalysis of the worldwide POTTER-AF study
Aims: Oesophageal fistula (OF) is a rare but life-threatening complication of atrial fibrillation (AF) ablation. Data on sex-related differences in its management and outcomes are limited. Methods and results: The PrOgnosis following oesophageal fisTula formaTion in patients undergoing cathetER ablation for AF study is a global, multicentre study evaluating the incidence, management, and outcome of OF following AF ablation. Among 553 729 patients treated across 214 centres in 35 countries between 1996 and 2022, 138 developed OF. Sex-specific data on management and outcome were available in 117 cases and are analysed herein. Females comprised 47% of the analysed cohort. Baseline characteristics, ablation modality, and use of oesophageal temperature monitoring were not different between sexes in patients developing OF. Fewer women received proton pump inhibitors post-procedure (64.8% vs. 84.7%; P = 0.017). Among patients with OF, less women developed atrio-OF (90.9% vs. 100%; P = 0.021). Oesophageal perforation and oesophageal–pericardial fistula occurred exclusively in females. The median duration until symptoms onset was 20 days for women and 16.5 days for men (P = 0.14). Echocardiography was more frequently used in women (36.4% vs. 15%; P = 0.01). Stroke was more common in women (32.7% vs. 14.8%; P = 0.040), however only before adjusting for potential cofounders. Other complications were comparable. Women underwent endoscopic therapy more often (35.8% vs. 17.7%; P = 0.034) and surgical treatment alone less frequently (28.3% vs. 51.6%; P = 0.014). Fatality rates were high and not different (63.6% in women vs. 67.2% in men; P = 0.70). Conclusion: While OF incidence for each sex could not be calculated, nearly half of all patients with OF were female. Women underwent more often endoscopic and less often surgical interventions; outcomes were comparable.
- Open Access
- 7 October 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (10)
Influence of proton pump inhibitors on the incidence and clinical course of oesophageal fistula following catheter ablation for atrial fibrillation: a subanalysis of the POTTER-AF study
- 7 October 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (10)
Open AccessInfluence of proton pump inhibitors on the incidence and clinical course of oesophageal fistula following catheter ablation for atrial fibrillation: a subanalysis of the POTTER-AF study
- 8 April 2025
- Published by Springer Nature
- p. 25-36
Puncture Techniques in the Catheter Lab
- 8 April 2025
- Published by Springer Nature
- p. 19-24
Setup in the EP Lab
- Open Access
- 19 September 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (18) , e030615
Use of the Wearable Cardioverter‐Defibrillator Among Patients With Myocarditis and Reduced Ejection Fraction or Ventricular Tachyarrhythmia: Data From a Multicenter Registry
Background: Data on the use of the wearable cardioverter‐defibrillator (WCD) among patients with myocarditis remain sparse. Consequently, evidence for guideline recommendations in this patient population is lacking. Methods and Results: In total, 1596 consecutive patients were included in a multicenter registry from 8 European centers, with 124 patients (8%) having received the WCD due to myocarditis and reduced left ventricular ejection fraction or prior ventricular tachyarrhythmia. The mean age was 51.6±16.3 years, with 74% being male. Patients were discharged after index hospitalization on heart failure medication: Angiotensin‐converting enzyme inhibitors (62.5%), angiotensin‐receptor‐neprilysin inhibitor (22.9%), aldosterone‐antagonists (51%), or beta blockers (91.4%). The initial median left ventricular ejection fraction was 30% (22%–45%) and increased to 48% (39%–55%) over long‐term follow‐up ( P P =0.022). The mean wear time was 79.7±52.1 days and 21.0±4.9 hours per day. Arrhythmic event rates documented by the WCD were 9.7% for nonsustained ventricular tachycardia, 6.5% for sustained ventricular tachycardia, and 0% for ventricular fibrillation. Subsequently, 2.4% of patients experienced an appropriate WCD shock. The rate of inappropriate WCD shocks was 0.8%. All 3 patients with appropriate WCD shock had experienced ventricular tachycardia/ventricular fibrillation before WCD prescription, with only 1 patient showing a left ventricular ejection fraction <35%. Conclusions: Patients with myocarditis and risk for occurrence of ventricular tachyarrhythmia may benefit from WCD use. Prior ventricular arrhythmia might appear as a better risk predictor than a reduced left ventricular ejection fraction <35% in this population.
- 19 September 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (18) , e030615
Open AccessUse of the Wearable Cardioverter‐Defibrillator Among Patients With Myocarditis and Reduced Ejection Fraction or Ventricular Tachyarrhythmia: Data From a Multicenter Registry
Background: Data on the use of the wearable cardioverter‐defibrillator (WCD) among patients with myocarditis remain sparse. Consequently, evidence for guideline recommendations in this patient population is lacking. Methods and Results: In total, 1596 consecutive patients were included in a multicenter registry from 8 European centers, with 124 patients (8%) having received the WCD due to myocarditis and reduced left ventricular ejection fraction or prior ventricular tachyarrhythmia. The mean age was 51.6±16.3 years, with 74% being male. Patients were discharged after index hospitalization on heart failure medication: Angiotensin‐converting enzyme inhibitors (62.5%), angiotensin‐receptor‐neprilysin inhibitor (22.9%), aldosterone‐antagonists (51%), or beta blockers (91.4%). The initial median left ventricular ejection fraction was 30% (22%–45%) and increased to 48% (39%–55%) over long‐term follow‐up ( P P =0.022). The mean wear time was 79.7±52.1 days and 21.0±4.9 hours per day. Arrhythmic event rates documented by the WCD were 9.7% for nonsustained ventricular tachycardia, 6.5% for sustained ventricular tachycardia, and 0% for ventricular fibrillation. Subsequently, 2.4% of patients experienced an appropriate WCD shock. The rate of inappropriate WCD shocks was 0.8%. All 3 patients with appropriate WCD shock had experienced ventricular tachycardia/ventricular fibrillation before WCD prescription, with only 1 patient showing a left ventricular ejection fraction <35%. Conclusions: Patients with myocarditis and risk for occurrence of ventricular tachyarrhythmia may benefit from WCD use. Prior ventricular arrhythmia might appear as a better risk predictor than a reduced left ventricular ejection fraction <35% in this population.
- Open Access
- 12 December 2022
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (2) , 600-609
EASY-WPW: a novel ECG-algorithm for easy and reliable localization of manifest accessory pathways in children and adults
Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients’ heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (ϰ>0.8; P < 0.001*). The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.
- 12 December 2022
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (2) , 600-609
Open AccessEASY-WPW: a novel ECG-algorithm for easy and reliable localization of manifest accessory pathways in children and adults
Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients’ heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (ϰ>0.8; P < 0.001*). The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.
- Open Access
- 1 June 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (6) , 175
Telemonitoring Potential of Wearable Cardioverter-Defibrillators during the Follow-Up of Patients with Heart Failure
Background: Wearable cardioverter-defibrillators (WCDs) are a well-established tool to bridge the recovery time of left ventricular ejection fraction (LVEF) until the implantation of an implantable cardioverter defibrillator (ICD), as recommended by the current guidelines. Besides their function to detect and treat malignant arrhythmias, WCDs may be used as a telemonitoring system. In this study, we sought to illustrate and discuss the telemonitoring potential of WCDs and to analyze physical activity in specific patient cohorts. Methods and Results: We retrospectively included 140 patients with reduced LVEF who were prescribed WCDs in our clinic. We analyzed the patients’ physical activity (n = 105 with a WCD compliance above 21 h/day), body position and resting position. We found a reduced physical activity in women and in patients over the age of 65 compared to younger patients. Furthermore, the patients who were overweight or obese showed significantly reduced physical activity compared to the patients with a normal weight (6365 ± 3572 vs. 4972 ± 2476 vs. 7045 ± 3521, p = 0.02). Conclusion: WCDs may be used as a telemonitoring and intervention tool in patients with reduced LVEF. Specific patient groups may benefit from guidance from their treating physician regarding physical activity.
- 1 June 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (6) , 175
Open AccessTelemonitoring Potential of Wearable Cardioverter-Defibrillators during the Follow-Up of Patients with Heart Failure
Background: Wearable cardioverter-defibrillators (WCDs) are a well-established tool to bridge the recovery time of left ventricular ejection fraction (LVEF) until the implantation of an implantable cardioverter defibrillator (ICD), as recommended by the current guidelines. Besides their function to detect and treat malignant arrhythmias, WCDs may be used as a telemonitoring system. In this study, we sought to illustrate and discuss the telemonitoring potential of WCDs and to analyze physical activity in specific patient cohorts. Methods and Results: We retrospectively included 140 patients with reduced LVEF who were prescribed WCDs in our clinic. We analyzed the patients’ physical activity (n = 105 with a WCD compliance above 21 h/day), body position and resting position. We found a reduced physical activity in women and in patients over the age of 65 compared to younger patients. Furthermore, the patients who were overweight or obese showed significantly reduced physical activity compared to the patients with a normal weight (6365 ± 3572 vs. 4972 ± 2476 vs. 7045 ± 3521, p = 0.02). Conclusion: WCDs may be used as a telemonitoring and intervention tool in patients with reduced LVEF. Specific patient groups may benefit from guidance from their treating physician regarding physical activity.
- 14 February 2022
- Published by Springer Nature in Herzschrittmachertherapie + Elektrophysiologie
- Vol. 33 (1) , 88-97
Katheterablation ventrikulärer Tachykardien bei Patienten mit ischämischer Kardiomyopathie
Zusammenfassung Die Radiofrequenz-Katheterablation stellt eine erfolgreiche Therapieoption für Patienten mit narbenabhängigen ventrikulären Tachykardien (VT) im Rahmen einer ischämischen Kardiomyopathie dar. Der Nutzen der Katheterablation ventrikulärer Tachykardien konnte in zahlreichen klinischen Studien belegt werden, und das Verfahren zählt zur klinischen Routine vieler elektrophysiologischer Katheterlabore. Dieser Artikel stellt eine praxisnahe Anleitung zur Durchführung einer Ablation von ischämischen ventrikulären Tachykardien zur Verfügung. Die Autoren beschreiben dazu sowohl konventionelle als auch substratorientierte Mapping- und Ablationsstrategien sowie Ansätze zur Integration von Bildgebungsmodalitäten. Diese Arbeit setzt eine Reihe von Artikeln fort, die für eine Weiterbildung im Bereich der speziellen Rhythmologie erstellt worden sind.
- 14 February 2022
- Published by Springer Nature in Herzschrittmachertherapie + Elektrophysiologie
- Vol. 33 (1) , 88-97
Katheterablation ventrikulärer Tachykardien bei Patienten mit ischämischer Kardiomyopathie
Zusammenfassung Die Radiofrequenz-Katheterablation stellt eine erfolgreiche Therapieoption für Patienten mit narbenabhängigen ventrikulären Tachykardien (VT) im Rahmen einer ischämischen Kardiomyopathie dar. Der Nutzen der Katheterablation ventrikulärer Tachykardien konnte in zahlreichen klinischen Studien belegt werden, und das Verfahren zählt zur klinischen Routine vieler elektrophysiologischer Katheterlabore. Dieser Artikel stellt eine praxisnahe Anleitung zur Durchführung einer Ablation von ischämischen ventrikulären Tachykardien zur Verfügung. Die Autoren beschreiben dazu sowohl konventionelle als auch substratorientierte Mapping- und Ablationsstrategien sowie Ansätze zur Integration von Bildgebungsmodalitäten. Diese Arbeit setzt eine Reihe von Artikeln fort, die für eine Weiterbildung im Bereich der speziellen Rhythmologie erstellt worden sind.
- Open Access
- 4 February 2022
- Published by Wiley in Journal of Arrhythmia
- Vol. 38 (2) , 238-244
Transesophageal echocardiography guided transseptal puncture and nadir temperatures in cryoballoon pulmonary vein isolation
Introduction Cryoballoon (CB) guided pulmonary vein isolation (PVI) is an established procedure in the treatment of atrial fibrillation (AF). Transseptal access is an indispensable step during PVI and may be associated with severe complications. For specific interventions, specific puncture sites of the fossa ovalis are advantageous. Here, we analyzed the potential impact of a transesophageal echocardiography (TOE) guided transseptal puncture on nadir temperatures in CB PVI. Methods and Results We retrospectively analyzed 209 patients undergoing CB PVI in our hospital. The use of TOE had been at the operator’s discretion. No TOE-related complications such as perforation of the pharynx or esophagus or loss of teeth were noted. Concerning the applied freezes, we found significantly lower nadir temperatures in all PVs in the TOE group than in the non-TOE group. Procedure time and fluoroscopy time and complications were similar in both groups. Conclusion TOE-guided TSP in CB PVI is safe and feasible. Our study found significantly lower nadir temperatures of CB freezes after TOE-guided TSP which potentially underscores the value of a more infero-anterior puncture site.
- 4 February 2022
- Published by Wiley in Journal of Arrhythmia
- Vol. 38 (2) , 238-244
Open AccessTransesophageal echocardiography guided transseptal puncture and nadir temperatures in cryoballoon pulmonary vein isolation
Introduction Cryoballoon (CB) guided pulmonary vein isolation (PVI) is an established procedure in the treatment of atrial fibrillation (AF). Transseptal access is an indispensable step during PVI and may be associated with severe complications. For specific interventions, specific puncture sites of the fossa ovalis are advantageous. Here, we analyzed the potential impact of a transesophageal echocardiography (TOE) guided transseptal puncture on nadir temperatures in CB PVI. Methods and Results We retrospectively analyzed 209 patients undergoing CB PVI in our hospital. The use of TOE had been at the operator’s discretion. No TOE-related complications such as perforation of the pharynx or esophagus or loss of teeth were noted. Concerning the applied freezes, we found significantly lower nadir temperatures in all PVs in the TOE group than in the non-TOE group. Procedure time and fluoroscopy time and complications were similar in both groups. Conclusion TOE-guided TSP in CB PVI is safe and feasible. Our study found significantly lower nadir temperatures of CB freezes after TOE-guided TSP which potentially underscores the value of a more infero-anterior puncture site.