Jaebin Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jaebin Choi has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Adriaan Johannes Taal
Department of Electrical Engineering, Columbia University, New York, NY 10027, USA
2 shared publications Eric H. Pollmann
Department of Electrical Engineering, Columbia University, New York, USA
2 shared publications- Kenneth L. Shepard
Columbia University
2 shared publications Michael L. Roukes
Department of Physics, California Institute of Technology, Pasadena, USA
2 shared publicationsAdriaan J. Taal
Department of Electrical Engineering, Columbia University, New York, USA
1 shared publication- Alejandro Akrouh
Department of Electrical Engineering, Columbia University, New York, USA
1 shared publication
Latest Publications
- Open Access
Implantable CMOS Deep-Brain Fluorescence Imager with Single-Neuron Resolution
Despite the advantages of optical imaging over electrophysiology, such as cell-type specificity, its application has been limited to the investigation of shallow brain regions (< 2 mm) because of the light scattering property of brain tissue. Passive optical conduits such as graded-index lenses and waveguides have permitted access to deeper locales but with restricted resolution and field of view, while creating massive lesions along the inserted path, with little pathway to improvement in the technology. As an alternative, we present the Acus device, an active implantable complementary metal-oxide-semiconductor (CMOS) neural imager with a 512-pixel silicon image sensor post- processed into a 4.1-mm-long, 120-μm-wide shank with a collinear fiber for illumination, which is able to record transient fluorescent signals in deep brain regions at 400 frames/sec. Acus can achieve single-neuron resolution in functional imaging of GCaMP6s-expressing neurons at a frame rate of 400 frames/sec.
Open AccessImplantable CMOS Deep-Brain Fluorescence Imager with Single-Neuron Resolution
Despite the advantages of optical imaging over electrophysiology, such as cell-type specificity, its application has been limited to the investigation of shallow brain regions (< 2 mm) because of the light scattering property of brain tissue. Passive optical conduits such as graded-index lenses and waveguides have permitted access to deeper locales but with restricted resolution and field of view, while creating massive lesions along the inserted path, with little pathway to improvement in the technology. As an alternative, we present the Acus device, an active implantable complementary metal-oxide-semiconductor (CMOS) neural imager with a 512-pixel silicon image sensor post- processed into a 4.1-mm-long, 120-μm-wide shank with a collinear fiber for illumination, which is able to record transient fluorescent signals in deep brain regions at 400 frames/sec. Acus can achieve single-neuron resolution in functional imaging of GCaMP6s-expressing neurons at a frame rate of 400 frames/sec.
- 10 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (4) , 636-645
Fully Integrated Time-Gated 3D Fluorescence Imager for Deep Neural Imaging
This paper presents a device for time-gated fluorescence imaging in the deep brain, consisting of two on-chip laser diodes and 512 single-photon avalanche diodes (SPADs). The edge-emitting laser diodes deliver fluorescence excitation above the SPAD array, parallel to the imager. In the time domain, laser diode illumination is pulsed and the SPAD is time-gated, allowing a fluorescence excitation rejection up to O.D. 3 at 1 ns of time-gate delay. Each SPAD pixel is masked with Talbot gratings to enable the mapping of 2D array photon counts into a 3D image. The 3D image achieves a resolution of 40, 35, and 73 μm in the x, y, and z directions, respectively, in a noiseless environment, with a maximum frame rate of 50 kilo-frames-per-second. We present measurement results of the spatial and temporal profiles of the dual-pulsed laser diode illumination and of the photon detection characteristics of the SPAD array. Finally, we show the imager's ability to resolve a glass micropipette filled with red fluorescent microspheres. The system's 420 μm-wide cross section allows it to be inserted at arbitrary depths of the brain while achieving a field of view four times larger than fiber endoscopes of equal diameter.
- 10 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (4) , 636-645
Fully Integrated Time-Gated 3D Fluorescence Imager for Deep Neural Imaging
This paper presents a device for time-gated fluorescence imaging in the deep brain, consisting of two on-chip laser diodes and 512 single-photon avalanche diodes (SPADs). The edge-emitting laser diodes deliver fluorescence excitation above the SPAD array, parallel to the imager. In the time domain, laser diode illumination is pulsed and the SPAD is time-gated, allowing a fluorescence excitation rejection up to O.D. 3 at 1 ns of time-gate delay. Each SPAD pixel is masked with Talbot gratings to enable the mapping of 2D array photon counts into a 3D image. The 3D image achieves a resolution of 40, 35, and 73 μm in the x, y, and z directions, respectively, in a noiseless environment, with a maximum frame rate of 50 kilo-frames-per-second. We present measurement results of the spatial and temporal profiles of the dual-pulsed laser diode illumination and of the photon detection characteristics of the SPAD array. Finally, we show the imager's ability to resolve a glass micropipette filled with red fluorescent microspheres. The system's 420 μm-wide cross section allows it to be inserted at arbitrary depths of the brain while achieving a field of view four times larger than fiber endoscopes of equal diameter.
- 23 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (11) , 2957-2968
A 512-Pixel, 51-kHz-Frame-Rate, Dual-Shank, Lens-Less, Filter-Less Single-Photon Avalanche Diode CMOS Neural Imaging Probe
We present an implantable single-photon shank-based imager, monolithically integrated onto a single CMOS IC. The imager comprises of 512 single-photon avalanche diodes distributed along two shanks, with a 6-bit depth in-pixel memory and an on-chip digital-to-time converter. To scale down the system to a minimally invasive form factor, we substitute optical filtering and focusing elements with a time-gated, angle-sensitive detection system. The imager computationally reconstructs the position of fluorescent sources within a 3-D volume of 3.4 mm$\times $ 600$\mathrm {\mu }\text{m}\,\,\times $ 400$\mu \text{m}$ .- 23 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (11) , 2957-2968
A 512-Pixel, 51-kHz-Frame-Rate, Dual-Shank, Lens-Less, Filter-Less Single-Photon Avalanche Diode CMOS Neural Imaging Probe
We present an implantable single-photon shank-based imager, monolithically integrated onto a single CMOS IC. The imager comprises of 512 single-photon avalanche diodes distributed along two shanks, with a 6-bit depth in-pixel memory and an on-chip digital-to-time converter. To scale down the system to a minimally invasive form factor, we substitute optical filtering and focusing elements with a time-gated, angle-sensitive detection system. The imager computationally reconstructs the position of fluorescent sources within a 3-D volume of 3.4 mm$\times $ 600$\mathrm {\mu }\text{m}\,\,\times $ 400$\mu \text{m}$ .