Katri Nousiainen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Katri Nousiainen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Teemu Mäkelä
HUS Diagnostic Center, Radiology, Helsinki University and Helsinki University Hospital, Haartmaninkatu 4, 00290 Helsinki, Finland; Department of Physics, University of Helsinki, P.O. Box 64, 00014 Helsinki, Finland
3 shared publications - Juha I. Peltonen
HUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
2 shared publications Anneli Piilonen
HUS Medical Imaging Center, Radiology, University of Helsinki and Helsinki University Hospital, P.O. Box 340, FI-00029 HUS, Helsinki, Finland
1 shared publicationCarl Siversson
Spectronic Medical AB Helsingborg Sweden
1 shared publicationGrichar Valdes Santurio
Department of Oncology, Radiotherapy Research Unit, Herlev and Gentofte Hospital Copenhagen University Herlev Denmark
1 shared publication- Henna Kavaluus
Comprehensive Cancer Center University of Helsinki and Helsinki University Hospital Helsinki Finland
1 shared publication
Latest Publications
- Open Access
- 8 November 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (3)
Evaluation of MRI‐only based online adaptive radiotherapy of abdominal region on MR‐linac
Purpose: A hybrid magnetic resonance linear accelerator (MRL) can perform magnetic resonance imaging (MRI) with high soft‐tissue contrast to be used for online adaptive radiotherapy (oART). To obtain electron densities needed for the oART dose calculation, a computed tomography (CT) is often deformably registered to MRI. Our aim was to evaluate an MRI‐only based synthetic CT (sCT) generation as an alternative to the deformed CT (dCT)‐based oART in the abdominal region.Methods: The study data consisted of 57 patients who were treated on a 0.35 T MRL system mainly for abdominal tumors. Simulation MRI‐CT pairs of 43 patients were used for training and validation of a prototype convolutional neural network sCT‐generation algorithm, based on HighRes3DNet, for the abdominal region. For remaining test patients, sCT images were produced from simulation MRIs and daily MRIs. The dCT‐based plans were re‐calculated on sCT with identical calculation parameters. The sCT and dCT were compared in terms of geometric agreement and calculated dose.Results: The mean and one standard deviation of the geometric agreement metrics over dCT–sCT‐pairs were: mean error of 8 ± 10 HU, mean absolute error of 49 ± 10 HU, and Dice similarity coefficient of 55 ± 12%, 60 ± 5%, and 82 ± 15% for bone, fat, and lung tissues, respectively. The dose differences between the sCT and dCT‐based dose for planning target volumes were 0.5 ± 0.9%, 0.6 ± 0.8%, and 0.5 ± 0.8% at D2%, D50%, and D98% in physical dose and 0.8 ± 1.4%, 0.8 ± 1.2%, and 0.6 ± 1.1% in biologically effective dose (BED). For organs‐at‐risk, the dose differences of all evaluated dose–volume histogram points were within [–4.5%, 7.8%] and [–1.1 Gy, 3.5 Gy] in both physical dose and BED.Conclusions: The geometric agreement metrics were within typically reported values and most average relative dose differences were within 1%. Thus, an MRI‐only sCT‐based approach is a promising alternative to the current clinical practice of the abdominal oART on MRL.
- 8 November 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (3)
Open AccessEvaluation of MRI‐only based online adaptive radiotherapy of abdominal region on MR‐linac
Purpose: A hybrid magnetic resonance linear accelerator (MRL) can perform magnetic resonance imaging (MRI) with high soft‐tissue contrast to be used for online adaptive radiotherapy (oART). To obtain electron densities needed for the oART dose calculation, a computed tomography (CT) is often deformably registered to MRI. Our aim was to evaluate an MRI‐only based synthetic CT (sCT) generation as an alternative to the deformed CT (dCT)‐based oART in the abdominal region.Methods: The study data consisted of 57 patients who were treated on a 0.35 T MRL system mainly for abdominal tumors. Simulation MRI‐CT pairs of 43 patients were used for training and validation of a prototype convolutional neural network sCT‐generation algorithm, based on HighRes3DNet, for the abdominal region. For remaining test patients, sCT images were produced from simulation MRIs and daily MRIs. The dCT‐based plans were re‐calculated on sCT with identical calculation parameters. The sCT and dCT were compared in terms of geometric agreement and calculated dose.Results: The mean and one standard deviation of the geometric agreement metrics over dCT–sCT‐pairs were: mean error of 8 ± 10 HU, mean absolute error of 49 ± 10 HU, and Dice similarity coefficient of 55 ± 12%, 60 ± 5%, and 82 ± 15% for bone, fat, and lung tissues, respectively. The dose differences between the sCT and dCT‐based dose for planning target volumes were 0.5 ± 0.9%, 0.6 ± 0.8%, and 0.5 ± 0.8% at D2%, D50%, and D98% in physical dose and 0.8 ± 1.4%, 0.8 ± 1.2%, and 0.6 ± 1.1% in biologically effective dose (BED). For organs‐at‐risk, the dose differences of all evaluated dose–volume histogram points were within [–4.5%, 7.8%] and [–1.1 Gy, 3.5 Gy] in both physical dose and BED.Conclusions: The geometric agreement metrics were within typically reported values and most average relative dose differences were within 1%. Thus, an MRI‐only sCT‐based approach is a promising alternative to the current clinical practice of the abdominal oART on MRL.
- Open Access
- 3 June 2022
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 35 (6) , 983-995
Characterizing geometric distortions of 3D sequences in clinical head MRI
Objective: Phantoms are often used to estimate the geometric accuracy in magnetic resonance imaging (MRI). However, the distortions may differ between anatomical and phantom images. This study aimed to investigate the applicability of a phantom-based and a test-subject-based method in evaluating geometric distortion present in clinical head-imaging sequences. Materials and methods: We imaged a 3D-printed phantom and test subjects with two MRI scanners using two clinical head-imaging 3D sequences with varying patient-table positions and receiver bandwidths. The geometric distortions were evaluated through nonrigid registrations: the displaced acquisitions were compared against the ideal isocenter positioning, and the varied bandwidth volumes against the volume with the highest bandwidth. The phantom acquisitions were also registered to a computed tomography scan. Results: Geometric distortion magnitudes increased with larger table displacements and were in good agreement between the phantom and test-subject acquisitions. The effect of increased distortions with decreasing receiver bandwidth was more prominent for test-subject acquisitions. Conclusion: Presented results emphasize the sensitivity of the geometric accuracy to positioning and imaging parameters. Phantom limitations may become an issue with some sequence types, encouraging the use of anatomical images for evaluating the geometric accuracy.
- 3 June 2022
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 35 (6) , 983-995
Open AccessCharacterizing geometric distortions of 3D sequences in clinical head MRI
Objective: Phantoms are often used to estimate the geometric accuracy in magnetic resonance imaging (MRI). However, the distortions may differ between anatomical and phantom images. This study aimed to investigate the applicability of a phantom-based and a test-subject-based method in evaluating geometric distortion present in clinical head-imaging sequences. Materials and methods: We imaged a 3D-printed phantom and test subjects with two MRI scanners using two clinical head-imaging 3D sequences with varying patient-table positions and receiver bandwidths. The geometric distortions were evaluated through nonrigid registrations: the displaced acquisitions were compared against the ideal isocenter positioning, and the varied bandwidth volumes against the volume with the highest bandwidth. The phantom acquisitions were also registered to a computed tomography scan. Results: Geometric distortion magnitudes increased with larger table displacements and were in good agreement between the phantom and test-subject acquisitions. The effect of increased distortions with decreasing receiver bandwidth was more prominent for test-subject acquisitions. Conclusion: Presented results emphasize the sensitivity of the geometric accuracy to positioning and imaging parameters. Phantom limitations may become an issue with some sequence types, encouraging the use of anatomical images for evaluating the geometric accuracy.
- 1 March 2021
- Published by Elsevier in Physica Medica
- Vol. 83, 138-145
Automating chest radiograph imaging quality control
- 1 March 2021
- Published by Elsevier in Physica Medica
- Vol. 83, 138-145
Automating chest radiograph imaging quality control
- Open Access
- 1 January 2021
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 17, 58-64
Determination of acceptance criteria for geometric accuracy of magnetic resonance imaging scanners used in radiotherapy planning
- 1 January 2021
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 17, 58-64
Open AccessDetermination of acceptance criteria for geometric accuracy of magnetic resonance imaging scanners used in radiotherapy planning
- Open Access
- 23 October 2019
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 33 (3) , 401-410
Measuring geometric accuracy in magnetic resonance imaging with 3D-printed phantom and nonrigid image registration
Objective: We aimed to develop a vendor-neutral and interaction-free quality assurance protocol for measuring geometric accuracy of head and brain magnetic resonance (MR) images. We investigated the usability of nonrigid image registration in the analysis and looked for the optimal registration parameters. Materials and methods: We constructed a 3D-printed phantom and imaged it with 12 MR scanners using clinical sequences. We registered a geometric-ground-truth computed tomography (CT) acquisition to the MR images using an open-source nonrigid-registration-toolbox with varying parameters. We applied the transforms to a set of control points in the CT image and compared their locations to the corresponding visually verified reference points in the MR images. Results: With optimized registration parameters, the mean difference (and standard deviation) of control point locations when compared to the reference method was (0.17 ± 0.02) mm for the 12 studied scanners. The maximum displacements varied from 0.50 to 1.35 mm or 0.89 to 2.30 mm, with vendors’ distortion correction on or off, respectively. Discussion: Using nonrigid CT–MR registration can provide a robust and relatively test-object-agnostic method for estimating the intra- and inter-scanner variations of the geometric distortions.
- 23 October 2019
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 33 (3) , 401-410
Open AccessMeasuring geometric accuracy in magnetic resonance imaging with 3D-printed phantom and nonrigid image registration
Objective: We aimed to develop a vendor-neutral and interaction-free quality assurance protocol for measuring geometric accuracy of head and brain magnetic resonance (MR) images. We investigated the usability of nonrigid image registration in the analysis and looked for the optimal registration parameters. Materials and methods: We constructed a 3D-printed phantom and imaged it with 12 MR scanners using clinical sequences. We registered a geometric-ground-truth computed tomography (CT) acquisition to the MR images using an open-source nonrigid-registration-toolbox with varying parameters. We applied the transforms to a set of control points in the CT image and compared their locations to the corresponding visually verified reference points in the MR images. Results: With optimized registration parameters, the mean difference (and standard deviation) of control point locations when compared to the reference method was (0.17 ± 0.02) mm for the 12 studied scanners. The maximum displacements varied from 0.50 to 1.35 mm or 0.89 to 2.30 mm, with vendors’ distortion correction on or off, respectively. Discussion: Using nonrigid CT–MR registration can provide a robust and relatively test-object-agnostic method for estimating the intra- and inter-scanner variations of the geometric distortions.