Bala Subramanya Pavan Kumar Kandala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Bala Subramanya Pavan Kumar Kandala has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Vesselin Shanov
Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH 45221, USA
3 shared publications Capucine Lcorriveau
Charles River Laboratories Montreal ULC, Boisbriand, Quebec, J7H 1N8, Canada
1 shared publication- Chandra Sekharan Nair Omana Amma Sreekala
Department of Chemistry, Amrita School of Arts and Sciences, Amritapuri, Amrita Vishwa Vidyapeetham, Amrita University, Kollam, India
1 shared publication Dana Begun
Waygate Technologies, Baker Hughes, Cincinnati, OH, 45241, USA
1 shared publicationG Zhang
Department of Mechanical and Materials Engineering, University of Cincinnati, OH 45221
1 shared publicationGuangqi Zhang
Department of Mechanical and Materials Engineering, University of Cincinnati, OH, 45221, USA
1 shared publication
Latest Publications
- Open Access
- 1 June 2021
- Published by KEAI Publishing in Bioactive Materials
- Vol. 6 (6) , 1663-1675
Preliminary study on modelling, fabrication by photo-chemical etching and in vivo testing of biodegradable magnesium AZ31 stents
Magnesium metal (Mg) is a promising material for stent applications due to its biocompatibility and ability to be resorbed by the body. Manufacturing of stents by laser cutting has become an industry standard. Our alternative approach uses photo-chemical etching to transfer a pattern of the stent onto a Mg sheet. In this study, we present three stages of creating and validating a stent prototype, which includes design and simulation using finite element analysis (FEA), followed by fabrication based on AZ31 alloy and, finally, in vivo testing in peripheral arteries of domestic pigs. Due to the preliminary character of this study, only six stents were implanted in two domestic farm pigs weighing 25–28 kg and they were evaluated after 28 days, with an interim follow-up on day 14. The left and right superficial femoral, the left iliac, and the right renal artery were selected for this study. The diameters of the stented artery segments were evaluated at the time of implantation, on day 14 and then, finally, on day 28, by quantitative vessel analysis (QVA) using fluoroscopic imaging. Optical Coherence Tomography (OCT) imaging displayed some malposition, breaks, stacking, and protrusion into the lumen at the proximal, distal, and mid-sections of the stented arteries. The stents degraded with time, but simultaneously became embedded in the intima. After 28 days, the animals were euthanized, and explanted vessels were fixed for micro-CT imaging and histology studies. Micro-CT imaging revealed stent morphological and volumetric changes due to the in-body degradation. An in vivo corrosion rate of 0.75 mm/year was obtained by the CT evaluation. The histology suggested no-life threatening effects, although moderate injury, inflammation, and endothelialization scores were observed.
- 1 June 2021
- Published by KEAI Publishing in Bioactive Materials
- Vol. 6 (6) , 1663-1675
Open AccessPreliminary study on modelling, fabrication by photo-chemical etching and in vivo testing of biodegradable magnesium AZ31 stents
Magnesium metal (Mg) is a promising material for stent applications due to its biocompatibility and ability to be resorbed by the body. Manufacturing of stents by laser cutting has become an industry standard. Our alternative approach uses photo-chemical etching to transfer a pattern of the stent onto a Mg sheet. In this study, we present three stages of creating and validating a stent prototype, which includes design and simulation using finite element analysis (FEA), followed by fabrication based on AZ31 alloy and, finally, in vivo testing in peripheral arteries of domestic pigs. Due to the preliminary character of this study, only six stents were implanted in two domestic farm pigs weighing 25–28 kg and they were evaluated after 28 days, with an interim follow-up on day 14. The left and right superficial femoral, the left iliac, and the right renal artery were selected for this study. The diameters of the stented artery segments were evaluated at the time of implantation, on day 14 and then, finally, on day 28, by quantitative vessel analysis (QVA) using fluoroscopic imaging. Optical Coherence Tomography (OCT) imaging displayed some malposition, breaks, stacking, and protrusion into the lumen at the proximal, distal, and mid-sections of the stented arteries. The stents degraded with time, but simultaneously became embedded in the intima. After 28 days, the animals were euthanized, and explanted vessels were fixed for micro-CT imaging and histology studies. Micro-CT imaging revealed stent morphological and volumetric changes due to the in-body degradation. An in vivo corrosion rate of 0.75 mm/year was obtained by the CT evaluation. The histology suggested no-life threatening effects, although moderate injury, inflammation, and endothelialization scores were observed.
- Open Access
- 1 January 2020
- Published by Knowledge Enterprise Journals in Medical Research Archives
- Vol. 8 (3)
Effect of Surface-Modification on In Vitro Corrosion of Biodegradable Magnesium-Based Helical Stent Fabricated by Photo-chemical Etching
During the last decade, magnesium and its alloys have been extensively studied to develop a new generation of biodegradable medical implants. The fast degradation rate of pure magnesium and related alloys in the physiological environment poses significant challenges to devices made of these materials for biomedical applications. In this study we have designed and fabricated biodegradable helical stents made of AZ31 magnesium alloy, and have explored their in vitro corrosion behavior in Dulbecco's Modified Eagle's Medium (DMEM). The corrosion rate was significantly reduced by surface modifications of the helical stent, achieved through applying a biocompatible Parylene C polymer coating, or via appropriate chemical etching of the devices in inorganic solutions. The corrosion rates of the coated AZ31 Mg helical stents were compared with uncoated samples used as a control. The results achieved indicated that all tested surface modifications successfully inhibited metal corrosion rates in vitro. Materials coated with Parylene C coating revealed a maximum corrosion rate reduction of 70% to 85% in DMEM solution.
- 1 January 2020
- Published by Knowledge Enterprise Journals in Medical Research Archives
- Vol. 8 (3)
Open AccessEffect of Surface-Modification on In Vitro Corrosion of Biodegradable Magnesium-Based Helical Stent Fabricated by Photo-chemical Etching
During the last decade, magnesium and its alloys have been extensively studied to develop a new generation of biodegradable medical implants. The fast degradation rate of pure magnesium and related alloys in the physiological environment poses significant challenges to devices made of these materials for biomedical applications. In this study we have designed and fabricated biodegradable helical stents made of AZ31 magnesium alloy, and have explored their in vitro corrosion behavior in Dulbecco's Modified Eagle's Medium (DMEM). The corrosion rate was significantly reduced by surface modifications of the helical stent, achieved through applying a biocompatible Parylene C polymer coating, or via appropriate chemical etching of the devices in inorganic solutions. The corrosion rates of the coated AZ31 Mg helical stents were compared with uncoated samples used as a control. The results achieved indicated that all tested surface modifications successfully inhibited metal corrosion rates in vitro. Materials coated with Parylene C coating revealed a maximum corrosion rate reduction of 70% to 85% in DMEM solution.
- Open Access
- 24 October 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (21) , 4503
In Vitro and In Vivo Testing of Zinc as a Biodegradable Material for Stents Fabricated by Photo-Chemical Etching
There is an increasing interest in biodegradable metal implants made from magnesium (Mg), iron (Fe), zinc (Zn) and their alloys because they are well tolerated in vivo and have mechanical properties that approach those of non-degradable metals. In particular, Zn and its alloys show the potential to be the next generation of biodegradable materials for medical implants. However, Zn has not been as well-studied as Mg, especially for stent applications. Manufacturing stents by laser cutting has become an industry standard. Nevertheless, the use of this approach with Zn faces some challenges, such as generating thermal stress, dross sticking on the device, surface oxidation, and the need for expensive thin-walled Zn tubing and post-treatment. All of these challenges motivated us to employ photo-chemical etching for fabricating different designs of Zn (99.95% pure) stents. The stents were constructed with different strut patterns, made by photo-chemical etching, and mechanically tested to evaluate radial forces. Stents with rhombus design patterns showed a promising 0.167N/mm radial force, which was comparable to Mg-based stents. In vitro studies were conducted with uncoated Zn stents as control and Parylene C-coated Zn stents to determine corrosion rates. The Parylene C coating reduced the corrosion rate by 50% compared to uncoated stents. In vivo studies were carried out by implanting photo-chemically etched, uncoated Zn stent segments subcutaneously in a C57BL/6 mice model. Histological analyses provided favorable data about the surrounding tissue status, as well as nerve and blood vessel responses near the implant, providing insights into the in vivo degradation of the metal struts. All of these experiments confirmed that Zn has the potential for use in biodegradable stent applications.
- 24 October 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (21) , 4503
Open AccessIn Vitro and In Vivo Testing of Zinc as a Biodegradable Material for Stents Fabricated by Photo-Chemical Etching
There is an increasing interest in biodegradable metal implants made from magnesium (Mg), iron (Fe), zinc (Zn) and their alloys because they are well tolerated in vivo and have mechanical properties that approach those of non-degradable metals. In particular, Zn and its alloys show the potential to be the next generation of biodegradable materials for medical implants. However, Zn has not been as well-studied as Mg, especially for stent applications. Manufacturing stents by laser cutting has become an industry standard. Nevertheless, the use of this approach with Zn faces some challenges, such as generating thermal stress, dross sticking on the device, surface oxidation, and the need for expensive thin-walled Zn tubing and post-treatment. All of these challenges motivated us to employ photo-chemical etching for fabricating different designs of Zn (99.95% pure) stents. The stents were constructed with different strut patterns, made by photo-chemical etching, and mechanically tested to evaluate radial forces. Stents with rhombus design patterns showed a promising 0.167N/mm radial force, which was comparable to Mg-based stents. In vitro studies were conducted with uncoated Zn stents as control and Parylene C-coated Zn stents to determine corrosion rates. The Parylene C coating reduced the corrosion rate by 50% compared to uncoated stents. In vivo studies were carried out by implanting photo-chemically etched, uncoated Zn stent segments subcutaneously in a C57BL/6 mice model. Histological analyses provided favorable data about the surrounding tissue status, as well as nerve and blood vessel responses near the implant, providing insights into the in vivo degradation of the metal struts. All of these experiments confirmed that Zn has the potential for use in biodegradable stent applications.
- Open Access
- 24 April 2013
- Published by Springer Nature in Journal of Nanostructure in Chemistry
- Vol. 3 (1) , 19
Functionalized multi-walled carbon nanotubes for enhanced photocurrent in dye-sensitized solar cells
- 24 April 2013
- Published by Springer Nature in Journal of Nanostructure in Chemistry
- Vol. 3 (1) , 19
Open AccessFunctionalized multi-walled carbon nanotubes for enhanced photocurrent in dye-sensitized solar cells