Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Krzysztof Skarżyński has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Energy efficiency of quasi-monochromatic LEDs for road lighting under mesopic vision

    by Sławomir Zalewski, Krzysztof Skarżyński, Piotr Pracki

    The study addresses the energy efficiency of quasi-monochromatic LEDs for road lighting under mesopic vision conditions. It provides the outcome from the initial stage of research into the potential of such lighting at low adaptation levels. Outdoor electric lighting is widespread and essential for ensuring safety after dark, and current developments increasingly emphasize sustainable LED-based solutions. The existing standards define luminance levels for photopic vision, while nighttime conditions on illuminated roads fall within the mesopic range (0.005–5.000 cd/m 2 ). The research aimed to determine potential of quasi-monochromatic LEDs and energy savings resulting from the use of the light sources in road lighting. Laboratory tests included LED chip samples with peak wavelengths between 495 and 605 nm. The analysis considered the spectral power distribution, S/P ratio and mesopic luminous efficacy of the LEDs, normalized power density and annual energy density for road lighting under mesopic vision conditions. The results confirmed that quasi-monochromatic LEDs are an alternative worth studying for mesopic vision conditions and can improve the energy efficiency of road lighting. For LEDs emitting within 495–570 nm range, mesopic luminous efficacy increased as adaptation luminance decreased. The analysis also showed that, compared with HPS lamps, a 570 nm LED and a mixed spectrum combining 2884 K and 500 nm LEDs may offer up to 20% higher energy efficiency at the lowest lighting levels (0.3–0.5 cd/m 2 ). Consequently, annual energy savings in road lighting may reach approximately 20% relative to HPS lamps and even 30% relative to a typical white LED.

  • Open Access

    The visual and photometric properties of LED rear position and stop lamps in cars

    by Julia Kwiatkowska, Krzysztof Skarżyński, Wojciech Żagan


  • Open Access

    Development of Simple and Affordable Integrating Device for Accurate LED Strip Light Measurement

    by Krzysztof Skarżyński, Tomasz Krzysztoń

    LED strips are increasingly used as lighting sources in public and private spaces. However, traditional photometric methods, such as integrating spheres, are unsuitable for measuring their light parameters, often resulting in significant errors and requiring expensive instrumentation or calibration. These errors are typically caused by non-uniform illumination of the internal surface or improper internal geometry, especially when measuring LED sources. This article presents the development of a low-cost integrating device specifically designed to measure LED strips’ light parameters. The device is a compact cube with a volume of less than 1.0 m3. It was tested against alternative methods using an integrating sphere and a goniophotometer in a professional photometric laboratory. The verification results confirmed its effectiveness. The device showed the maximum relative error of luminous flux measurement to be around 5% compared with the accurate, expensive goniophotometric method. For colorimetric measurements, the maximum Correlated Color Temperature (CCT) absolute error was about 35 K for an LED strip with a CCT of 4000 K, indicating a difference imperceptible to the human eye. These results demonstrate the device’s proper relevance in the research and development of LED strip-based lighting equipment to improve lighting equipment quality and control processes. The device is easy to replicate, significantly reducing production and transportation costs, making it an excellent solution for companies and research units seeking a cost-effective method for LED strip measurements. Additionally, the device can measure other light sources or luminaires with reasonably small sizes emitting light in only one hemisphere. The device is the basis of a patent application.


  • Open Access

    Evaluating the Quality of Light Emitted by Smartphone Displays

    by Nina Piechota, Krzysztof Skarżyński, Kamil Kubiak

    The increased use of smartphones in daily life challenges researchers regarding the quality of light emitted by screens. This study aims to analyze displays’ qualitative and quantitative light parameters from various smartphone models available on the market over the last decade. Advanced photometric and colorimetric measurements using complex instrumentation were performed. It covered the color gamut, channel linearity response, refresh rate, flickering, spatial radiation distribution, luminance, uniformity, and static contrast. The analysis showed that, despite advances in smartphone display technology, differences in visible radiation parameters between older and newer models are surprisingly marginal. However, improvements were observed in newer models in terms of viewing angles and compliance with the sRGB standard. Tested built-in blue light reduction filters were ineffective. It only slightly reduces light between 380 nm and 480 nm. In contrast, much higher decreases in this spectral range were achieved for dedicated applications. However, it lowered radiant power density across the visible spectrum, significantly decreasing the displays’ correlated color temperature. Enabling the power-saving mode caused the deterioration of parameters such as refresh rate, but the flicker depth remained constant. Static contrast for most tested devices was also at the same level. The findings confirm the need for further studies on display technology development that supports user well-being while minimizing its harmful effects.


  • Research note: On relation between photopic luminous efficacy and colour rendering of LED strips

    by K Skarżyński

    Light-emitting diode (LED) strips have recently become a top-rated light source, used primarily in interior lighting applications. This increase is mainly due to increased performance in technical parameters, primarily photopic luminous efficacy (PLE) and the CIE general colour rendering index ( R a ). The relation between PLE and R a was investigated for several types of light sources in the past and was found to be inversely related. However, confirming if a similar relation exists for the newest phosphor-converted LED strips based on up-to-date colour rendering metrics, such as TM-30-18 R f (ANSI/IES), is essential. This study was based on measurements of 105 different phosphor-converted LED strips with correlated colour temperatures (CCTs) from 2500 K to 5000 K. The results showed that lower PLE and higher R a usually characterize the group with lower CCTs than those with higher CCTs. In the group of LED strips below 3500 K, there is a strong negative linear correlation ( R 2 = 0.51, p < 0.001) between PLE and R a . However, in the group with CCTs above 3500 K, the linear correlation between PLE and R a is weaker ( R 2 = 0.29, p < 0.001). Moreover, the analysis of the relationship between PLE and TM-30-18 R f showed no association between those variables. Results suggest the need to rethink the influence of PLE on colour rendering in the case of using modern metrics for LED lighting. Finally, the results are a reasonable basis for the further analysis of such associations, which should be done periodically according to the rapid development of LED light sources.


  • Open Access

    The Photometric Testing of High-Resolution Digital Cameras from Smartphones—A Pilot Study

    by Sławomir Zalewski, Krzysztof Skarżyński

    Luminance is the fundamental photometric quantity representing the technical meaning of brightness. It is usually measured from a distance using a matrix sensor, which is the basis of the professional instrument. However, specific technical requirements must be fulfilled to achieve accurate results. This paper considers whether modern high-resolution smartphone cameras are suitable for luminance measurements. Three cameras from high-end smartphones were evaluated on a dedicated laboratory stand. The sensors’ output characteristics showed relatively good linearity of the individual R, G, and B channels. Unfortunately, the spectral sensitivities were unfavorable, as the minimum error achieved was about 17%. This device is classified outside the generally accepted quality scale for photometric instruments. The presented investigation confirmed that none of the high-resolution smartphone cameras tested was suitable for use as a universal luminance camera. However, one of the test devices can be developmental if restrictively calibrated and used only in a specialistic laboratory stand. Using a smartphone (or only its camera) for luminance measurements requires proper advanced calibration. It is possible, but it limits us to only dedicated applications. The pilot study presented in this paper will help create a suitable test stand for spectacle vision systems, e.g., virtual reality equipment.


  • Open Access

    Surface Disinfection Systems with UV-C Lamps – Verification Measurements and Design Procedure Proposal

    by Andrzej Wiśniewski, Krzysztof Skarżyński, Piotr Pracki, Rafał Krupiński, Agnieszka Wolska, Mariusz Wisełka, Andrzej Pawlak


  • Using a Single Sky Quality Meter for Simplified Light Pollution Changes Analysis Across a Big City

    by Krzysztof Skarżyński, Maciej Lach

    Light pollution involves introducing a large amount of electromagnetic radiation in the visible range (from 380 nm to 760 nm) into the Earth's atmosphere. Its source is all electric lighting installations and applications, such as internal and external lighting or automotive lighting. This phenomenon causes significant adverse effects for the entire environment, e.g., skyglow, limiting the visibility of astronomical objects, disturbances in the circadian rhythms of fauna and flora, or electric energy losses. Light pollution has been studied for at least 40 years. Various ways of measuring it using appropriate sensors and measuring equipment have been developed during this time. This paper presents basic information on light pollution and its measurements. It describes the technical characteristics of the commonly used simple photometer Sky Quality Meter and the problem of using LED lighting. It also describes the results of a measurement experiment in the metropolis of Warsaw, Poland, which made it possible to assess changes in light pollution inexpensively. Measurements and a simplified analysis made it possible to determine that light pollution in the capital of Poland increased by approx. 20% compared to 2015. Using only one low-priced sensor and the presented measurement method can also be successfully employed in other cities.


  • Open Access

    A Smart Floodlighting Design System Based on Raster Images

    by Rafał Krupiński, Wolfgang Scherzer, Piotr Pracki, Andrzej Wiśniewski, Krzysztof Skarżyński

    This article describes a system for designing floodlighting of objects using computer graphics. Contrary to the currently used visualisation tools, the developed computer application is based on the daytime photography of the object and not on its three-dimensional geometric model. The advantage of the system is the high photorealism of the simulation, with no need to create a collage of visualisation with photography. The designer uses the photometric data of luminaires, and their photometric and colourimetric parameters are defined. With the system it is possible to perform a precise lighting analysis—the distribution of illuminance and luminance—both for the entire facility and in any plane or point. The system also analyses the total installed power of a given design solution. The system application is presented as an example in the form of a case study. This example shows the features of the system and further expected directions of development.


  • Open Access

    The Interplay between Parameters of Light Pollution and Energy Efficiency for Outdoor Amenity Lighting

    by Krzysztof Skarżyński, Anna Rutkowska

    This paper is related to light pollution and the energy efficiency of outdoor amenity lighting. It concerns the standard design assessment parameters of light pollution, the Upward Light Ratio (ULR) and Upward Flux Ratio (UFR), and the classic energy efficiency parameter—Normalized Power Density (NPD). The motivation for this research was the observation of certain inaccuracies related to the applicability and interpretation of these parameters in practice and the lack of connection between parameters of light pollution and energy efficiency. The multi-variant computer simulations of the exemplary large-area parking lot lighting system were conducted. Over four hundred cases were carefully analyzed. Individual cases differ in the shape of the task area, luminaire arrangements, mounting height, luminous intensity distribution, aiming, and maintenance factor. The results confirmed that the criteria values of ULR and UFR are often overestimated for modern luminaires, which emit luminous flux emitted only downwards. In this case, the ULR and UFR values do not exceed the criteria values for even zones with lower ambient brightness. Thus, lighting solutions with much lower energy efficiency easily meet the requirements of these parameters. This situation is not rational. So, it is crucial to make the criteria of ULR and UFR much more stringent in all environmental zones. Moreover, the research confirms a strong positive linear correlation between UFR and NPD (0.92, p < 0.001), which means that light pollution can be reduced by ensuring an appropriate level of energy efficiency. It is a great help in designing sustainable outdoor amenity lighting.