Kazuhiro Harasaka
Research Subjects
Kazuhiro Harasaka has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Mitsuru Suzuki
Ricoh Company 2 , LTD. 5-10 Yokarakami, Kumanodo, Takadate, Natori, Miyagi 981-1241, Japan
2 shared publicationsShigeyoshi Goka
Graduate School of System Design, Tokyo Metropolitan University 3 , Hachioji, Tokyo 192-0397, Japan
2 shared publications- Shinya Yanagimachi
National Metrology Institute of Japan (NMIJ), AIST, Tsukuba, Ibaraki 305-8563
2 shared publications - Aravind Tharayil Narayanan
Tokyo Institute of Technology, Tokyo, Japan
1 shared publication - Atsushi Shirane
Department of Electrical and Electronic Engineering, Institute of Science Tokyo, Tokyo, Japan
1 shared publication - Hans Herdian
Department of Electrical and Electronic Engineering, Institute of Science Tokyo, Tokyo, Japan
1 shared publication
Latest Publications
- Open Access
- 9 March 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 116 (10) , 104102
Reducing frequency drift caused by light shift in coherent population trapping-based low-power atomic clocks
We propose a model to reduce the influence that the light-shift induced frequency drift has on the long-term stability of coherent population trapping (CPT)-based low-power atomic clocks. We experimentally validated the proposed model using the chip-scale atomic clock architecture. The model considers both the drift of the dc-bias current to compensate for the wavelength aging of the vertical-cavity surface-emitting laser (VCSEL) and the variation in the modulation index of the light field generated by the VCSEL. We investigated the dc-bias-current-dependency of the frequency drift in an atomic clock module both theoretically and experimentally, confirming that the frequency drift can change as a function of the VCSEL basic parameters. When the atomic clock module was operated over a period of five months at the dc-bias current affording a zero-crossing of the clock frequency drift, the Allan standard deviation and clock frequency drift for long-term stability were for averaging times of s and /day, respectively. Our approach is promising to improve the long-term stability of CPT-based low-power atomic clocks.- 9 March 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 116 (10) , 104102
Open AccessReducing frequency drift caused by light shift in coherent population trapping-based low-power atomic clocks
We propose a model to reduce the influence that the light-shift induced frequency drift has on the long-term stability of coherent population trapping (CPT)-based low-power atomic clocks. We experimentally validated the proposed model using the chip-scale atomic clock architecture. The model considers both the drift of the dc-bias current to compensate for the wavelength aging of the vertical-cavity surface-emitting laser (VCSEL) and the variation in the modulation index of the light field generated by the VCSEL. We investigated the dc-bias-current-dependency of the frequency drift in an atomic clock module both theoretically and experimentally, confirming that the frequency drift can change as a function of the VCSEL basic parameters. When the atomic clock module was operated over a period of five months at the dc-bias current affording a zero-crossing of the clock frequency drift, the Allan standard deviation and clock frequency drift for long-term stability were for averaging times of s and /day, respectively. Our approach is promising to improve the long-term stability of CPT-based low-power atomic clocks. - 7 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (11) , 3135-3148
ULPAC: A Miniaturized Ultralow-Power Atomic Clock
This article introduces a chip-scale ultralow-power atomic clock (ULPAC) in the microwave frequency region. A new suspended quantum package architecture along with a fully integrated frequency probing and locking loop implemented in CMOS technology results in a compact package and ultralow-power consumption. In addition, dedicated low-noise magnetic field and temperature control loops are incorporated for isolating and mitigating the internal and external factors affecting the frequency stability. The output frequency of a crystal oscillator is continuously compensated and stabilized by locking to the peak of a coherent population trapping signal, thereby inheriting the superior frequency stability of the atomic resonance. The proposed ULPAC system achieves a frequency stability of 2.2 x 10⁻¹² at an averaging time of 10⁵ s, while consuming 59.9 mW. The frequency probing and locking circuits implemented in a standard 65-nm CMOS process node occupy an area of 2.55 mm². The prototype of this atomic clock occupies a volume of 15 cm³.
- 7 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (11) , 3135-3148
ULPAC: A Miniaturized Ultralow-Power Atomic Clock
This article introduces a chip-scale ultralow-power atomic clock (ULPAC) in the microwave frequency region. A new suspended quantum package architecture along with a fully integrated frequency probing and locking loop implemented in CMOS technology results in a compact package and ultralow-power consumption. In addition, dedicated low-noise magnetic field and temperature control loops are incorporated for isolating and mitigating the internal and external factors affecting the frequency stability. The output frequency of a crystal oscillator is continuously compensated and stabilized by locking to the peak of a coherent population trapping signal, thereby inheriting the superior frequency stability of the atomic resonance. The proposed ULPAC system achieves a frequency stability of 2.2 x 10⁻¹² at an averaging time of 10⁵ s, while consuming 59.9 mW. The frequency probing and locking circuits implemented in a standard 65-nm CMOS process node occupy an area of 2.55 mm². The prototype of this atomic clock occupies a volume of 15 cm³.