Jidong Zhang
Jidong Zhang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Qiaogen Zhou
Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
2 shared publications - Bocheng Jiang
Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute (SARI), Chinese Academy of Sciences, 239 Zhangheng Road, Pudong District, Shanghai 201210, People's Republic of China
1 shared publication - Geyang Jiang
Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute (SARI), Chinese Academy of Sciences, 239 Zhangheng Road, Pudong District, Shanghai 201210, People's Republic of China
1 shared publication Jingmin Zhang
Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China
1 shared publication- Jingwei Zhuo
Shanghai Xiangou Automation System CO, 988 Datong Road B-2003, Zhabei District, Shanghai 200070, People's Republic of China
1 shared publication - Lifang Zheng
Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute (SARI), Chinese Academy of Sciences, 239 Zhangheng Road, Pudong District, Shanghai 201210, People's Republic of China
1 shared publication
Latest Publications
- 6 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-4
Cooling Design for the Magnetic Structure of SHINE Superconducting Undulator
- 6 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-4
Cooling Design for the Magnetic Structure of SHINE Superconducting Undulator
- 23 October 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (6) , 1911-1916
Confined-walking mode for an elliptical polarized undulator and its application
Elliptical polarized undulators (EPUs) are broadly used in the soft X-ray energy range. They have the advantage of providing photons with both varied energy and polarization through adjustments to the value of the gap and/or shift magnet arrays in an undulator. Yet these adjustments may create a disturbance on the stability of the electron beam in a storage ring. To correct such a disturbance, it is necessary to establish a feed-forward table of key nodes in the gap-shift-defined two-dimensional parameter space. Such a table can only be scanned during machine-study time. For a free-walking mode, whereby an undulator is allowed to manoeuvre in the whole gap-shift space, all the key nodes need to be scanned at the expense of a large amount of machine-study time. This will greatly delay the employment of a full-polarization capable undulator (especially circularly polarized). By analyzing data-collecting patterns of user experiments, this paper defines a reduced set of key nodes in gap-shift parameter space, with the number of key nodes to be scanned for feed-forwarding scaled down to one-third of the original; and introduces a new walking mode for EPUs: confined-walking mode, whereby the undulator is manoeuvred only within the reduced set of key nodes. Such a mode is firstly realized on the EPUs at the DREAMLINE beamline at Shanghai Synchrotron Radiation Facility (SSRF). Under confined-walking mode, the undulator movements are stable and there is no obvious disturbance to the electron beam with the feed-forward system in operation. Successful experiments have been carried out using the circularly polarized light obtained via the new walking mode. This mode is expected to be applied to future EPUs at SSRF with the increasing requirements for various polarization modes.
- 23 October 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (6) , 1911-1916
Confined-walking mode for an elliptical polarized undulator and its application
Elliptical polarized undulators (EPUs) are broadly used in the soft X-ray energy range. They have the advantage of providing photons with both varied energy and polarization through adjustments to the value of the gap and/or shift magnet arrays in an undulator. Yet these adjustments may create a disturbance on the stability of the electron beam in a storage ring. To correct such a disturbance, it is necessary to establish a feed-forward table of key nodes in the gap-shift-defined two-dimensional parameter space. Such a table can only be scanned during machine-study time. For a free-walking mode, whereby an undulator is allowed to manoeuvre in the whole gap-shift space, all the key nodes need to be scanned at the expense of a large amount of machine-study time. This will greatly delay the employment of a full-polarization capable undulator (especially circularly polarized). By analyzing data-collecting patterns of user experiments, this paper defines a reduced set of key nodes in gap-shift parameter space, with the number of key nodes to be scanned for feed-forwarding scaled down to one-third of the original; and introduces a new walking mode for EPUs: confined-walking mode, whereby the undulator is manoeuvred only within the reduced set of key nodes. Such a mode is firstly realized on the EPUs at the DREAMLINE beamline at Shanghai Synchrotron Radiation Facility (SSRF). Under confined-walking mode, the undulator movements are stable and there is no obvious disturbance to the electron beam with the feed-forward system in operation. Successful experiments have been carried out using the circularly polarized light obtained via the new walking mode. This mode is expected to be applied to future EPUs at SSRF with the increasing requirements for various polarization modes.
- 16 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054 (1) , 030020
High-precision Hall sensor array magnetic field measurement system
A Hall sensor array magnetic field measurement system consists of 16 HHP-MU [1] Hall sensors powered by a Keithley 6220 precision current source, which has been built and deployed at SSRF [2]. The voltages of the 16 sensors are sampled by 4 NI PCI-4462 and further converted to the magnetic field strength. The sensors mounted on a high-precision three-dimensional translating stage are used to scan the surface of a magnet block with the step-length of 1 mm. The surface field distributions of the magnet blocks within an in-vacuum undulator are obtainable using this system. Based on the data measured, the magnet blocks are sorted and installed on the undulator girders. The magnetic measurement results of this undulator indicate that this sorting strategy works well.
- 16 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054 (1) , 030020
High-precision Hall sensor array magnetic field measurement system
A Hall sensor array magnetic field measurement system consists of 16 HHP-MU [1] Hall sensors powered by a Keithley 6220 precision current source, which has been built and deployed at SSRF [2]. The voltages of the 16 sensors are sampled by 4 NI PCI-4462 and further converted to the magnetic field strength. The sensors mounted on a high-precision three-dimensional translating stage are used to scan the surface of a magnet block with the step-length of 1 mm. The surface field distributions of the magnet blocks within an in-vacuum undulator are obtainable using this system. Based on the data measured, the magnet blocks are sorted and installed on the undulator girders. The magnetic measurement results of this undulator indicate that this sorting strategy works well.