Lucien Chassin-Trubert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lucien Chassin-Trubert has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Pierre Alric
Department of Thoracic and Vascular Surgery, Arnaud de Villeneuve Hospital, Montpellier, France
6 shared publicationsBaris Ata Ozdemir
Centre for Surgical Research, Bristol Medical School, University of Bristol, Bristol, United Kingdom
4 shared publicationsLudovic Canaud
Department of Thoracic and Vascular Surgery, Arnaud de Villeneuve Hospital, Montpellier, France
4 shared publications- Ludovic Canaud
Department of Thoracic and Vascular Surgery, Arnaud de Villeneuve Hospital, Montpellier, France
4 shared publications Thomas Gandet
Department of Thoracic and Vascular Surgery, Arnaud de Villeneuve Hospital, Montpellier, France
3 shared publications- Youcef Lounes
Institut Cardiovasculaire Paris-Sud, Hôpital Jacques Cartier, 91300 Massy, France
3 shared publications
Latest Publications
- 27 September 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (4) , 921-928
Fenestrated Physician-Modified Endovascular Grafts for Aberrant Right Subclavian Artery and/or Kommerell’s diverticulum
Objective: The aim of this case series is to report feasibility, efficiency, and safety of fenestrated physician-modified endografts (PMEGs) in aortic arch pathologies with aberrant right subclavian artery (ARSA) and/or Kommerell’s diverticulum (KD). Methods: All consecutive patients with ARSA and/or KD who underwent hybrid aortic arch repair combined with homemade fenestrated stent-graft from 2018 to 2022 were reviewed. Results: Six patients with ARSA and/or KD underwent hybrid surgery for aortic repair, 4 of whom were men, with a mean age of 49 years. Furthermore, 2 of them were symptomatic with dysphagia, 1 was taken in emergency, 1 had a bovine arch and a KD, and 2 had right descending thoracic aortas. The mean operation time was 138 (111–216) minutes. In addition, 83% of the homemade grafts were double fenestrated. All the proximal landings were in zone 0; the mean proximal aortic diameter was 29 (23–34) mm. The range of diameters for the endografts were 24 to 38 mm. There was a 100% technical success, with 0% 30 days mortality, no stroke, and no endoleak. During the follow-up, no aortic-related death or secondary intervention was required and all supra-aortic vessels remain patent. Conclusion: Hybrid aortic arch repair, with fenestrated PMEGs for ARSA and/or KD, is associated with acceptable early and midterm major morbidity and mortality. Clinical Impact: This retrospective case series analyzed outcomes in 6 patients with an aberrant right subclavian artery and/or Kommerell’s diverticulum treated with fenestrated PMEGs during an average 16 month follow-up. The case series suggests that the use of these fenestrated PMEGs for the management of patients with an aberrant right subclavian artery is a safe, effective and durable method in the medium-term.
- 27 September 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (4) , 921-928
Fenestrated Physician-Modified Endovascular Grafts for Aberrant Right Subclavian Artery and/or Kommerell’s diverticulum
Objective: The aim of this case series is to report feasibility, efficiency, and safety of fenestrated physician-modified endografts (PMEGs) in aortic arch pathologies with aberrant right subclavian artery (ARSA) and/or Kommerell’s diverticulum (KD). Methods: All consecutive patients with ARSA and/or KD who underwent hybrid aortic arch repair combined with homemade fenestrated stent-graft from 2018 to 2022 were reviewed. Results: Six patients with ARSA and/or KD underwent hybrid surgery for aortic repair, 4 of whom were men, with a mean age of 49 years. Furthermore, 2 of them were symptomatic with dysphagia, 1 was taken in emergency, 1 had a bovine arch and a KD, and 2 had right descending thoracic aortas. The mean operation time was 138 (111–216) minutes. In addition, 83% of the homemade grafts were double fenestrated. All the proximal landings were in zone 0; the mean proximal aortic diameter was 29 (23–34) mm. The range of diameters for the endografts were 24 to 38 mm. There was a 100% technical success, with 0% 30 days mortality, no stroke, and no endoleak. During the follow-up, no aortic-related death or secondary intervention was required and all supra-aortic vessels remain patent. Conclusion: Hybrid aortic arch repair, with fenestrated PMEGs for ARSA and/or KD, is associated with acceptable early and midterm major morbidity and mortality. Clinical Impact: This retrospective case series analyzed outcomes in 6 patients with an aberrant right subclavian artery and/or Kommerell’s diverticulum treated with fenestrated PMEGs during an average 16 month follow-up. The case series suggests that the use of these fenestrated PMEGs for the management of patients with an aberrant right subclavian artery is a safe, effective and durable method in the medium-term.
- 4 August 2022
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 31 (1) , 89-97
Total Arch Thoracic Endovascular Aortic Repair Using Double Fenestrated Physician-Modified Stent-Grafts: 100 Patients
Objective: The aim was to evaluate early and medium-term outcomes of double fenestrated physician-modified endovascular grafts for total endovascular aortic arch repair. Methods: This single-center retrospective analysis of prospectively-collected data included 100 patients, from January 2017 to December 2021, undergoing thoracic endovascular aortic repair (TEVAR) for zone 0. The fenestrations were a proximal larger fenestration that incorporated the brach2iocephalic trunk and left common carotid artery and a distal smaller fenestration for the left subclavian artery (LSA). Only the LSA fenestration was stented. Results: The median duration for stent-graft modification was 23±6 minutes. Of the 100 patients, 70 were men. The mean patient age was 70±10.5 years. Indications for treatment included degenerative aortic arch aneurysm (n=32), dissecting aortic arch aneurysm after type A dissections (n=23) and (n=19) after type B dissections, acute complicated type B dissection (n=16), and other pathologies (n=10). Technical success rate was 97%. The 30 day mortality was 2% (n=2). Four patients (4%) had minor stroke with full recovery. One patient (1%) had a type IA endoleak, 1 patient (1%) had a type IB endoleak, and 2 patients (2%) have a type II endoleak from the LSA. Eight patients (8%) required reintervention: 1 type IA endoleak, 1 type IB endoleak, 1 retrograde type A dissection, and 5 because of access-related complications. During a mean follow-up of 24±7.2 months, there were no aortic rupture, paraplegia, and all supra-aortic trunks were patent. Conclusions: Double homemade fenestrated TEVAR is both feasible and effective for total endovascular aortic arch repair avoiding the need for anatomical and extra-anatomical surgical revascularization. The long-term durability will need to be assessed in studies with long-term follow-up. Clinical Impact: Double homemade fenestrated TEVAR is effective for total endovascular aortic arch repair avoiding the need for anatomical and extra-anatomical surgical revascularization. The standout feature of this double fenestrated device is its simple handling during operation with the proximal fenestrations being directed to the orifices of the BT and LCCA automatically when the LSA fenestration is catheterized and secured by covered stent placement. The deployment algorithm actively steers the operator away from superfluous manipulations of the device within the arch and avoids guidewire manipulation in carotid arteries. The long-term durability will need to be assessed in studies with long-term follow-up.
- 4 August 2022
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 31 (1) , 89-97
Total Arch Thoracic Endovascular Aortic Repair Using Double Fenestrated Physician-Modified Stent-Grafts: 100 Patients
Objective: The aim was to evaluate early and medium-term outcomes of double fenestrated physician-modified endovascular grafts for total endovascular aortic arch repair. Methods: This single-center retrospective analysis of prospectively-collected data included 100 patients, from January 2017 to December 2021, undergoing thoracic endovascular aortic repair (TEVAR) for zone 0. The fenestrations were a proximal larger fenestration that incorporated the brach2iocephalic trunk and left common carotid artery and a distal smaller fenestration for the left subclavian artery (LSA). Only the LSA fenestration was stented. Results: The median duration for stent-graft modification was 23±6 minutes. Of the 100 patients, 70 were men. The mean patient age was 70±10.5 years. Indications for treatment included degenerative aortic arch aneurysm (n=32), dissecting aortic arch aneurysm after type A dissections (n=23) and (n=19) after type B dissections, acute complicated type B dissection (n=16), and other pathologies (n=10). Technical success rate was 97%. The 30 day mortality was 2% (n=2). Four patients (4%) had minor stroke with full recovery. One patient (1%) had a type IA endoleak, 1 patient (1%) had a type IB endoleak, and 2 patients (2%) have a type II endoleak from the LSA. Eight patients (8%) required reintervention: 1 type IA endoleak, 1 type IB endoleak, 1 retrograde type A dissection, and 5 because of access-related complications. During a mean follow-up of 24±7.2 months, there were no aortic rupture, paraplegia, and all supra-aortic trunks were patent. Conclusions: Double homemade fenestrated TEVAR is both feasible and effective for total endovascular aortic arch repair avoiding the need for anatomical and extra-anatomical surgical revascularization. The long-term durability will need to be assessed in studies with long-term follow-up. Clinical Impact: Double homemade fenestrated TEVAR is effective for total endovascular aortic arch repair avoiding the need for anatomical and extra-anatomical surgical revascularization. The standout feature of this double fenestrated device is its simple handling during operation with the proximal fenestrations being directed to the orifices of the BT and LCCA automatically when the LSA fenestration is catheterized and secured by covered stent placement. The deployment algorithm actively steers the operator away from superfluous manipulations of the device within the arch and avoids guidewire manipulation in carotid arteries. The long-term durability will need to be assessed in studies with long-term follow-up.
- Open Access
- 7 March 2022
- Published by Elsevier in Annals of Vascular Surgery - Brief Reports and Innovations
- Vol. 2 (1) , 100056
Renal artery reimplantation for secondary hypertension due to diaphragmatic crus compression: A case report and literature review.
- 7 March 2022
- Published by Elsevier in Annals of Vascular Surgery - Brief Reports and Innovations
- Vol. 2 (1) , 100056
Open AccessRenal artery reimplantation for secondary hypertension due to diaphragmatic crus compression: A case report and literature review.
- Open Access
- 19 July 2021
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 33 (3) , 500
Corrigendum to ‘Endovascular aortic arch repair with a pre-cannulated double-fenestrated physician-modified stent graft: a benchtop experiment’ [Interact CardioVasc Thorac Surg 2021;32:942–9; doi:10.1093/icvts/ivab023]
In the original version of this article, the first name of author Pierre-Antoine Peyron and his affiliation were misspelled. This has now been corrected above and in the full article.
- 19 July 2021
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 33 (3) , 500
Open AccessCorrigendum to ‘Endovascular aortic arch repair with a pre-cannulated double-fenestrated physician-modified stent graft: a benchtop experiment’ [Interact CardioVasc Thorac Surg 2021;32:942–9; doi:10.1093/icvts/ivab023]
In the original version of this article, the first name of author Pierre-Antoine Peyron and his affiliation were misspelled. This has now been corrected above and in the full article.
- 1 June 2021
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 73 (6) , 1898-1905.e1
Double fenestrated physician-modified stent-grafts for total aortic arch repair in 50 patients
- 1 June 2021
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 73 (6) , 1898-1905.e1
Double fenestrated physician-modified stent-grafts for total aortic arch repair in 50 patients
- 21 September 2020
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 70, 570.e1-570.e5
Asymptomatic Internal Carotid Aneurysm: An Uncommon Disease of the Carotid Arteries
- 21 September 2020
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 70, 570.e1-570.e5
Asymptomatic Internal Carotid Aneurysm: An Uncommon Disease of the Carotid Arteries
- 4 June 2020
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 27 (5) , 785-791
Aortic Arch Anatomy Pattern in Patients Treated Using Double Homemade Fenestrated Stent-Grafts for Total Endovascular Aortic Arch Repair
Purpose: To analyze the structural variation of the aortic arch and the supra-aortic arteries and establish an average spatial configuration that would be a pattern for a “universal double fenestration” design for physician-modified endovascular grafts (PMEGs) used in total thoracic endovascular aortic repair (TEVAR). Materials and Methods: Aortic arch morphology was retrospectively analyzed by reviewing the preoperative thoracic computed tomography angiography scans in 33 consecutive patients (mean age 68 years; 27 men) treated between January 2017 and March 2019 using double-fenestrated PMEGs for zone 0 TEVAR. Image analysis was completed according to a standardized technique on a vascular workstation with center lumen line reconstruction for all measurements. Variations in branching pattern of the aortic arch were classified into 8 types. Results: The arch trunk configuration was type I in 26 patients (79%), type II in 5 (15%), type III in 1, and type IV in 1. Mean aortic diameters at the level of mid ascending aorta, innominate artery (IA), left common carotid artery (LCCA), and left subclavian artery (LSA) were 35.7±3.7, 34.2±4.5, 33.3±6.7, and 33.7±4.7 mm, respectively. Mean diameters of the trunk were 12.2±1.7, 7.5±1.4, and 8.0±0.8 mm, respectively. Mean longitudinal center to center lengths were 15.9±2.5 mm between the LSA and LCCA and 12.1±3.0 mm between the LCCA and IA. Mean clock positions using the LSA as reference were 12:50 for the IA and 12:05 for the LCCA. In 32 patients (97%) all the supra-aortic branch vessels fit perfectly inside two delimited areas defined by a proximal common square area of 30×30 mm for the IA and LCCA and a second distal 8-mm-diameter circle for the LSA. Conclusion: Variations of the aortic arch anatomy are numerous and common. A general morphological pattern is described that delimits the aortic area where these variations occur. This information can be utilized for the design of an off-the-shelf double-fenestrated stent-graft for zone 0 TEVAR.
- 4 June 2020
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 27 (5) , 785-791
Aortic Arch Anatomy Pattern in Patients Treated Using Double Homemade Fenestrated Stent-Grafts for Total Endovascular Aortic Arch Repair
Purpose: To analyze the structural variation of the aortic arch and the supra-aortic arteries and establish an average spatial configuration that would be a pattern for a “universal double fenestration” design for physician-modified endovascular grafts (PMEGs) used in total thoracic endovascular aortic repair (TEVAR). Materials and Methods: Aortic arch morphology was retrospectively analyzed by reviewing the preoperative thoracic computed tomography angiography scans in 33 consecutive patients (mean age 68 years; 27 men) treated between January 2017 and March 2019 using double-fenestrated PMEGs for zone 0 TEVAR. Image analysis was completed according to a standardized technique on a vascular workstation with center lumen line reconstruction for all measurements. Variations in branching pattern of the aortic arch were classified into 8 types. Results: The arch trunk configuration was type I in 26 patients (79%), type II in 5 (15%), type III in 1, and type IV in 1. Mean aortic diameters at the level of mid ascending aorta, innominate artery (IA), left common carotid artery (LCCA), and left subclavian artery (LSA) were 35.7±3.7, 34.2±4.5, 33.3±6.7, and 33.7±4.7 mm, respectively. Mean diameters of the trunk were 12.2±1.7, 7.5±1.4, and 8.0±0.8 mm, respectively. Mean longitudinal center to center lengths were 15.9±2.5 mm between the LSA and LCCA and 12.1±3.0 mm between the LCCA and IA. Mean clock positions using the LSA as reference were 12:50 for the IA and 12:05 for the LCCA. In 32 patients (97%) all the supra-aortic branch vessels fit perfectly inside two delimited areas defined by a proximal common square area of 30×30 mm for the IA and LCCA and a second distal 8-mm-diameter circle for the LSA. Conclusion: Variations of the aortic arch anatomy are numerous and common. A general morphological pattern is described that delimits the aortic area where these variations occur. This information can be utilized for the design of an off-the-shelf double-fenestrated stent-graft for zone 0 TEVAR.
- 24 October 2019
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 27 (3) , 377-384
Midterm Follow-up of Fenestrated and Scalloped Physician-Modified Endovascular Grafts for Zone 2 TEVAR
Purpose: To investigate the midterm outcomes of scalloped or fenestrated physician-modified endovascular grafts (PMEGs) for zone 2 thoracic endovascular aortic repairs (TEVAR). Materials and Methods: Between November 2013 and May 2019, 54 consecutive patients (mean age 63 years; 41 men) were treated with thoracic PMEGs modified with 7 scallops or 47 fenestrations for the left subclavian artery (LSA). Indications for aortic repair were acute complicated type B aortic dissection (17, 31%), degenerative aneurysm (13, 24%), acute traumatic rupture of the aortic isthmus (9, 16%), post chronic dissection aneurysmal evolution (8, 15%), penetrating aortic ulcer (3, 6%), intramural hematoma (2, 4%), and floating thrombus (2, 4%). Results: Technical success was 94%; 3 (6%) LSAs were unintentionally covered. An intraoperative type Ia endoleak was treated during the index procedure. One (2%) patient suffered spinal cord ischemia, with irreversible bilateral paraplegia. Three (6%) patients experience postoperative minor strokes with full neurological recovery. Four (7%) patients died in the perioperative period; 2 (2%) were due to aneurysm rupture. Mean follow-up was 26±16 months; 15 (28%) patients had at least 3 years of follow-up. Two (4%) type II endoleaks were identified and successfully treated (4% reintervention rate); no other endoleaks were identified. All the LSAs remained clinically and radiologically patent. There were no conversions to open repair, ruptures, retrograde dissection, stent fracture, migrations, or other aortic complications. Conclusion: Scalloped or single-fenestrated PMEGs for the LSA appear to be durable and safe in the midterm. Combined with low periprocedural morbidity and mortality, these results suggest that this approach can be considered as an off-label alternative to extend proximal seal to zone 2 for TEVAR. Further studies with a larger number of patients and long-term outcomes are needed to fully validate this approach.
- 24 October 2019
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 27 (3) , 377-384
Midterm Follow-up of Fenestrated and Scalloped Physician-Modified Endovascular Grafts for Zone 2 TEVAR
Purpose: To investigate the midterm outcomes of scalloped or fenestrated physician-modified endovascular grafts (PMEGs) for zone 2 thoracic endovascular aortic repairs (TEVAR). Materials and Methods: Between November 2013 and May 2019, 54 consecutive patients (mean age 63 years; 41 men) were treated with thoracic PMEGs modified with 7 scallops or 47 fenestrations for the left subclavian artery (LSA). Indications for aortic repair were acute complicated type B aortic dissection (17, 31%), degenerative aneurysm (13, 24%), acute traumatic rupture of the aortic isthmus (9, 16%), post chronic dissection aneurysmal evolution (8, 15%), penetrating aortic ulcer (3, 6%), intramural hematoma (2, 4%), and floating thrombus (2, 4%). Results: Technical success was 94%; 3 (6%) LSAs were unintentionally covered. An intraoperative type Ia endoleak was treated during the index procedure. One (2%) patient suffered spinal cord ischemia, with irreversible bilateral paraplegia. Three (6%) patients experience postoperative minor strokes with full neurological recovery. Four (7%) patients died in the perioperative period; 2 (2%) were due to aneurysm rupture. Mean follow-up was 26±16 months; 15 (28%) patients had at least 3 years of follow-up. Two (4%) type II endoleaks were identified and successfully treated (4% reintervention rate); no other endoleaks were identified. All the LSAs remained clinically and radiologically patent. There were no conversions to open repair, ruptures, retrograde dissection, stent fracture, migrations, or other aortic complications. Conclusion: Scalloped or single-fenestrated PMEGs for the LSA appear to be durable and safe in the midterm. Combined with low periprocedural morbidity and mortality, these results suggest that this approach can be considered as an off-label alternative to extend proximal seal to zone 2 for TEVAR. Further studies with a larger number of patients and long-term outcomes are needed to fully validate this approach.