SSScott J. Seltzer

Scott J. Seltzer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Scott J. Seltzer has a total of 88 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Permeability from NMR in the Unconventional Point-Pleasant Formation

    by Xinglin Wang, Philip M. Singer, Yunke Liu, Zeliang Chen, George J. Hirasaki, Zheng Yang, Scott J. Seltzer, Boqin Sun, Marcus O. Wigand, Jon E. Burger


  • Open Access

    Dielectric Polarization Studies in Partially Saturated Shale Cores

    by Paul R. J. Connolly, Matthew Josh, Keelan T. O'NEill, Scott J. Seltzer, Marcus O. Wigand, Michael B. Clennell, Eric F. May, Michael L. Johns

    Dielectric measurements of reservoir rocks are used to estimate important petro‐physical properties such as water‐filled porosity and pore surface textures. However, complex dielectric polarization processes that occur in rocks are strongly dependent on frequency, making physically meaningful interpretation of broadband dielectric data difficult. At high frequency (> 10 MHz) dielectric permittivity primarily relates to the volume fractions of constituents (i.e., saturation, minerals), while at lower frequency (< 10 MHz), interpretation is complicated by interfacial polarization, electro‐diffusion phenomena, and ohmic conduction. The ability to de‐convolve these electrical processes is critical for interpreting petro‐physical properties from broadband dielectric data. Here we demonstrate the application of Tikhonov regularization methods to compute dielectric relaxation time distributions from broadband (40 Hz to 110 MHz) dielectric data for ten shale core samples at varying partial saturation. Furthermore, via the Kramers‐Kronig relation, the contribution from in‐phase conduction currents to the imaginary component of the dielectric response was quantified. The evolution of dielectric polarization processes with increasing moisture content was analyzed directly from changes in relaxation time distributions. It was found that the dominant polarization mechanism, up to a critical partial saturation, occurred as surface polarization within the electrical double layer. Above this critical partial saturation, electro‐diffusion mechanisms acting between the Stern and diffuse layers resulted in a large low frequency response. This work provides valuable insight into dielectric polarization mechanisms in shales and demonstrates such measurements are sensitive to electrical double layer properties and electro‐diffusion length scales that are potentially relevant to characterizing pore‐scale properties in shales.


  • Open Access

    An optimized microfabricated platform for the optical generation and detection of hyperpolarized 129Xe

    by Daniel J. Kennedy, Scott J. Seltzer, Ricardo Jiménez-Martínez, Hattie L. Ring, Nicolas S. Malecek, Svenja Knappe, Elizabeth A. Donley, John Kitching, Vikram S. Bajaj, Alexander Pines

    Low thermal-equilibrium nuclear spin polarizations and the need for sophisticated instrumentation render conventional nuclear magnetic resonance (NMR) spectroscopy and imaging (MRI) incompatible with small-scale microfluidic devices. Hyperpolarized129Xe gas has found use in the study of many materials but has required very large and expensive instrumentation. Recently a microfabricated device with modest instrumentation demonstrated all-optical hyperpolarization and detection of129Xe gas. This device was limited by129Xe polarizations less than 1%,129Xe NMR signals smaller than 20 nT, and transport of hyperpolarized129Xe over millimeter lengths. Higher polarizations, versatile detection schemes, and flow of129Xe over larger distances are desirable for wider applications. Here we demonstrate an ultra-sensitive microfabricated platform that achieves129Xe polarizations reaching 7%, NMR signals exceeding 1 μT, lifetimes up to 6 s, and simultaneous two-mode detection, consisting of a high-sensitivityin situchannel with signal-to-noise of 105and a lower-sensitivityex situdetection channel which may be useful in a wider variety of conditions.129Xe is hyperpolarized and detected in locations more than 1 cm apart. Our versatile device is an optimal platform for microfluidic magnetic resonance in particular, but equally attractive for wider nuclear spin applications benefitting from ultra-sensitive detection, long coherences, and simple instrumentation.


  • An NMR Experimental Study and Model Validation on Capillary Condensation of Hydrocarbons Confined in Shale Gas Condensate Reservoirs

    by Haijing Wang, Scott J. Seltzer, Boqin Sun, Marcus Wigand, Carsten Horch, Frank Stallmach, Baoyan Li, Holger Thern, Alberto Mezzatesta, Roberto Arro, et al.

    Unlike conventional gas reservoirs, shale gas reservoirs contain organic mesopores that have pore sizes ranging from 2 to 50 nm. These organic pores may cause capillary condensation of confined hydrocarbons due to the non-negligible capillary pressure. A novel phase equilibrium model has been developed to quantify effects of pore size distribution on the phase behavior of confined hydrocarbons, including the occurrence of capillary condensation. However, it remains a challenge to assess the phase behavior of confined hydrocarbons by laboratory experiments. This is because the conventional pressure-volume-temperature (PVT) method measures the phase behavior of a bulk fluid. Here, we employ low- and high-field nuclear magnetic resonance (NMR) techniques to experimentally probe the capillary effect on phase behavior using retrograde condensates in synthetic porous media and shale rock samples. In low-field NMR experiments, water-wet porous glass and oil-wet polymer-based spherical activated carbon (PBSAC) beads are used as porous media. NMR relaxation times are used to observe the occurrence of capillary condensation for pure and mixed hydrocarbons at room temperature under controlled pressure. High-field NMR is employed to gain further sensitivity and resolution for the phase behavior of a confined methane-butane mixture. NMR spectroscopic signatures of the dew point were identified, enabling the comparison of dew-point pressures of the bulk hydrocarbons and hydrocarbons confined in grinded shale rock. NMR-measured dew point of confined hydrocarbons is ~115 psi higher than that of bulk phase. This pressure shift agrees well with simulation results. In summary, we present NMR experimental studies and model validation on the capillary condensation effect, showing a shift of dew-point pressures of confined hydrocarbons mixtures in porous media. The agreement between NMR and simulation results validates the novel phase equilibrium model implemented in the newly developed PVT simulation software. The lab measurements and model validation results show that a) oil-wet is one key condition for the occurrence of capillary condensation of confined hydrocarbons; b) the shift of an upper dew-point pressure of hydrocarbons confined in shale rock can be tens of psi to slightly over 100 psi for the retrograde condensate system being used; c) the phase equilibrium model is valid for modeling phase behavior of multi-component hydrocarbons confined in mesopores.


  • Ultra‐Low‐Field NMR Relaxation and Diffusion Measurements Using an Optical Magnetometer

    by Paul J. Ganssle, Hyun D. Shin, Scott J. Seltzer, Vikram S. Bajaj, Micah P. Ledbetter, Dmitry Budker, Svenja Knappe, John Kitching, Alexander Pines

    Nuclear magnetic resonance (NMR) relaxometry and diffusometry are important tools for the characterization of heterogeneous materials and porous media, with applications including medical imaging, food characterization and oil‐well logging. These methods can be extremely effective in applications where high‐resolution NMR is either unnecessary, impractical, or both, as is the case in the emerging field of portable chemical characterization. Here, we present a proof‐of‐concept experiment demonstrating the use of high‐sensitivity optical magnetometers as detectors for ultra‐low‐field NMR relaxation and diffusion measurements.


  • Open Access

    Optically detected cross-relaxation spectroscopy of electron spins in diamond

    by Hai-Jing Wang, Chang S. Shin, Scott J. Seltzer, Claudia E. Avalos, Alexander Pines, Vikram S. Bajaj

    The application of magnetic resonance spectroscopy at progressively smaller length scales may eventually permit ‘chemical imaging’ of spins at the surfaces of materials and biological complexes. In particular, the negatively charged nitrogen-vacancy (NV−) centre in diamond has been exploited as an optical transducer for nanoscale nuclear magnetic resonance. However, the spectra of detected spins are generally broadened by their interaction with proximate paramagnetic NV− centres through coherent and incoherent mechanisms. Here we demonstrate a detection technique that can resolve the spectra of electron spins coupled to NV− centres, in this case, substitutional nitrogen and neutral nitrogen-vacancy centres in diamond, through optically detected cross-relaxation. The hyperfine spectra of these spins are a unique chemical identifier, suggesting the possibility, in combination with recent results in diamonds harbouring shallow NV− implants, that the spectra of spins external to the diamond can be similarly detected.


  • Open Access

    Optical hyperpolarization and NMR detection of 129Xe on a microfluidic chip

    by Ricardo Jiménez-Martínez, Daniel J. Kennedy, Michael Rosenbluh, Elizabeth A. Donley, Svenja Knappe, Scott J. Seltzer, Hattie L. Ring, Vikram S. Bajaj, John Kitching

    Optically hyperpolarized 129Xe gas has become a powerful contrast agent in nuclear magnetic resonance (NMR) spectroscopy and imaging, with applications ranging from studies of the human lung to the targeted detection of biomolecules. Equally attractive is its potential use to enhance the sensitivity of microfluidic NMR experiments, in which small sample volumes yield poor sensitivity. Unfortunately, most 129Xe polarization systems are large and non-portable. Here we present a microfabricated chip that optically polarizes 129Xe gas. We have achieved 129Xe polarizations >0.5% at flow rates of several microlitres per second, compatible with typical microfluidic applications. We employ in situ optical magnetometry to sensitively detect and characterize the 129Xe polarization at magnetic fields of 1 μT. We construct the device using standard microfabrication techniques, which will facilitate its integration with existing microfluidic platforms. This device may enable the implementation of highly sensitive 129Xe NMR in compact, low-cost, portable devices.


  • Optically detected nuclear quadrupolar interaction ofN14in nitrogen-vacancy centers in diamond

    by Chang S. Shin, Mark C. Butler, Hai-Jing Wang, Claudia E. Avalos, Scott J. Seltzer, Ren-Bao Liu, Alexander Pines, Vikram S. Bajaj

    We report sensitive detection of the nuclear quadrupolar interaction of the N14 nuclear spin of the nitrogen-vacancy (NV) center using the electron spin-echo envelope modulation technique. We applied a weak transverse magnetic field to the spin system so that certain forbidden transitions became weakly allowed due to second-order effects involving the nonsecular terms of the hyperfine interaction. The weak transitions cause modulation of the electron spin-echo signal, and a theoretical analysis suggests that the modulation frequency is primarily determined by the nuclear quadrupolar frequency; numerical simulations confirm the analytical results and show excellent quantitative agreement with experiments. This is an experimentally simple method of detecting quadrupolar interactions, and it can be used to study spin systems with an energy structure similar to that of the NV center.


  • Suppression of electron spin decoherence of the diamond NV center by a transverse magnetic field

    by Chang S. Shin, Claudia E. Avalos, Mark C. Butler, Hai-Jing Wang, Scott J. Seltzer, Ren-Bao Liu, Alexander Pines, Vikram S. Bajaj

    We demonstrate that the spin decoherence of nitrogen vacancy (NV) centers in diamond can be suppressed by a transverse magnetic field if the electron spin bath is the primary decoherence source. The NV spin coherence, created in “a decoherence-free subspace,” is protected by the transverse component of the zero-field splitting, increasing the spin-coherence time about twofold. The decoherence due to the electron spin bath is also suppressed at magnetic fields stronger than ∼25 G when applied parallel to the NV symmetry axis. Our method can be used to extend the spin-coherence time of similar spin systems for applications in quantum computing, field sensing, and other metrologies.