Nan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nan Li has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Caihong Zhang
4 shared publicationsWanteng Wang
Yanshan University
4 shared publicationsMenglin Li
3 shared publications- Xingwang Tang
College of Automotive Engineering, Jilin University, Changchun, China
3 shared publications - Yaowang Pei3 shared publications
Fengxiang Chen
2 shared publications
Latest Publications
- Open Access
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Control-Oriented Modeling and Compensation-Based Temperature Regulation of Open-Cathode PEMFCs Under Multiple Disturbances
Proton exchange membrane fuel cell (PEMFC) performance is highly sensitive to stack temperature. Effective thermal management is therefore critical for enhancing output performance and prolonging system lifetime. However, the intrinsic nonlinear characteristics and external disturbances in open-cathode air-cooled PEMFC systems complicate the thermal regulation process, thereby increasing the difficulty of accurate temperature control. To address this issue, this study develops a model-based nonlinear compensation framework for temperature regulation in PEMFC systems. First, a control-oriented lumped-parameter model is developed. Key model parameters, including the fan-forced convective heat transfer coefficient under different fan duty cycles and the stack heat capacity, are experimentally identified to accurately characterize the thermal dynamics. Then, the inherent system nonlinearity and the effects of external disturbances, including ambient temperature variations and load-current fluctuations, are analyzed. Based on this analysis, a nonlinear transformation-based control strategy is developed to compensate for the inherent system nonlinearity and enhance disturbance rejection capability. Comparative tests demonstrate that the proposed strategy achieves improved control performance under multiple operating conditions. Under ambient temperature disturbances of 20°C, the temperature fluctuation is restricted to within 0.42°C, compared with 1.39°C for PI control. Under load current variations of 30A, the temperature fluctuation remains within 0.62°C, compared with 1.83°C for PI control.
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessControl-Oriented Modeling and Compensation-Based Temperature Regulation of Open-Cathode PEMFCs Under Multiple Disturbances
Proton exchange membrane fuel cell (PEMFC) performance is highly sensitive to stack temperature. Effective thermal management is therefore critical for enhancing output performance and prolonging system lifetime. However, the intrinsic nonlinear characteristics and external disturbances in open-cathode air-cooled PEMFC systems complicate the thermal regulation process, thereby increasing the difficulty of accurate temperature control. To address this issue, this study develops a model-based nonlinear compensation framework for temperature regulation in PEMFC systems. First, a control-oriented lumped-parameter model is developed. Key model parameters, including the fan-forced convective heat transfer coefficient under different fan duty cycles and the stack heat capacity, are experimentally identified to accurately characterize the thermal dynamics. Then, the inherent system nonlinearity and the effects of external disturbances, including ambient temperature variations and load-current fluctuations, are analyzed. Based on this analysis, a nonlinear transformation-based control strategy is developed to compensate for the inherent system nonlinearity and enhance disturbance rejection capability. Comparative tests demonstrate that the proposed strategy achieves improved control performance under multiple operating conditions. Under ambient temperature disturbances of 20°C, the temperature fluctuation is restricted to within 0.42°C, compared with 1.39°C for PI control. Under load current variations of 30A, the temperature fluctuation remains within 0.62°C, compared with 1.83°C for PI control.
- Open Access
- 7 July 2026
- Published by Elsevier in SSRN Electronic Journal
Energy Flow Analysis and Nonlinear Compensation-Based Temperature Control of Air-Cooled PEMFCs
In air-cooled proton exchange membrane fuel cell (PEMFC) systems, thermal regulation is challenged by complex heat transfer processes and the strong nonlinearity between fan actuation and stack temperature. To address this challenge, this study quantitatively investigates stack energy flow distribution and develops nonlinear temperature control strategies. A control-oriented dynamic model of the air-cooled PEMFC system is first developed. Based on this model, the energy-flow distribution within the stack is quantitatively analyzed. The results indicate that at the rated power of 2.1kW, the stack heat generation reaches 3.0kW, while the exhaust gas removes approximately 1.0kW of heat and fan-forced convective heat dissipation is about 1.9kW. Furthermore, the nonlinear relationship between fan duty cycle and heat transfer coefficient is experimentally characterized. Based on this relationship, two nonlinear-transformation-based control strategies are proposed to compensate for the fan-induced nonlinearity. Comparative studies under various operating conditions demonstrate that the proposed strategies provide fast dynamic response and effective temperature regulation. Under ambient-temperature disturbances, Strategy 2 limits the temperature fluctuation to below 0.1°C, compared with 0.43°C for Strategy 1 and 1.40°C for PI control. The proposed methods provide quantitative insights into stack energy flows and facilitate thermal management design for air-cooled PEMFC systems.
- 7 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnergy Flow Analysis and Nonlinear Compensation-Based Temperature Control of Air-Cooled PEMFCs
In air-cooled proton exchange membrane fuel cell (PEMFC) systems, thermal regulation is challenged by complex heat transfer processes and the strong nonlinearity between fan actuation and stack temperature. To address this challenge, this study quantitatively investigates stack energy flow distribution and develops nonlinear temperature control strategies. A control-oriented dynamic model of the air-cooled PEMFC system is first developed. Based on this model, the energy-flow distribution within the stack is quantitatively analyzed. The results indicate that at the rated power of 2.1kW, the stack heat generation reaches 3.0kW, while the exhaust gas removes approximately 1.0kW of heat and fan-forced convective heat dissipation is about 1.9kW. Furthermore, the nonlinear relationship between fan duty cycle and heat transfer coefficient is experimentally characterized. Based on this relationship, two nonlinear-transformation-based control strategies are proposed to compensate for the fan-induced nonlinearity. Comparative studies under various operating conditions demonstrate that the proposed strategies provide fast dynamic response and effective temperature regulation. Under ambient-temperature disturbances, Strategy 2 limits the temperature fluctuation to below 0.1°C, compared with 0.43°C for Strategy 1 and 1.40°C for PI control. The proposed methods provide quantitative insights into stack energy flows and facilitate thermal management design for air-cooled PEMFC systems.
- Open Access
- 30 June 2026
- Published by Elsevier in SSRN Electronic Journal
Physics-informed composite temperature control of liquid-cooled PEMFC systems through nonlinear compensation and thermal-coupling suppression
Operating temperature significantly influences the efficiency and durability of proton exchange membrane fuel cells (PEMFCs). However, the intrinsic nonlinearity and thermal-coupling disturbances of the thermal management system pose challenges to precise temperature regulation. To compensate for these effects, a composite temperature-control framework combining nonlinear transformation (NT), dynamic feedforward (DF) compensation, and internal model control-based PI control (IMC-PI) is proposed. Based on the experimentally identified nonlinear flow-allocation characteristic of the thermostat, a nonlinear inverse transformation is incorporated to compensate for the system nonlinearity. Furthermore, a dynamic feedforward compensation is designed based on the thermal-coupling relationship between coolant inlet and outlet temperatures to mitigate coupling disturbances under load transients. Comparative evaluations of the PI, PI+NT, and PI+NT+DF strategies are conducted under multiple current-step conditions. Results demonstrate that the PI+NT+DF significantly improves temperature control accuracy, dynamic performance, and system robustness. Under the 200–300A current-step condition, the overshoot of the PI, PI+NT, and PI+NT+DF strategies is reduced from 2.61°C and 0.84°C to an almost negligible response. Under the 100–500A current-step condition, the PI+NT+DF strategy further provides anticipatory thermostat regulation and improved transient temperature response. The proposed framework offers a physically interpretable solution for high-precision thermal management of PEMFC systems.
- 30 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPhysics-informed composite temperature control of liquid-cooled PEMFC systems through nonlinear compensation and thermal-coupling suppression
Operating temperature significantly influences the efficiency and durability of proton exchange membrane fuel cells (PEMFCs). However, the intrinsic nonlinearity and thermal-coupling disturbances of the thermal management system pose challenges to precise temperature regulation. To compensate for these effects, a composite temperature-control framework combining nonlinear transformation (NT), dynamic feedforward (DF) compensation, and internal model control-based PI control (IMC-PI) is proposed. Based on the experimentally identified nonlinear flow-allocation characteristic of the thermostat, a nonlinear inverse transformation is incorporated to compensate for the system nonlinearity. Furthermore, a dynamic feedforward compensation is designed based on the thermal-coupling relationship between coolant inlet and outlet temperatures to mitigate coupling disturbances under load transients. Comparative evaluations of the PI, PI+NT, and PI+NT+DF strategies are conducted under multiple current-step conditions. Results demonstrate that the PI+NT+DF significantly improves temperature control accuracy, dynamic performance, and system robustness. Under the 200–300A current-step condition, the overshoot of the PI, PI+NT, and PI+NT+DF strategies is reduced from 2.61°C and 0.84°C to an almost negligible response. Under the 100–500A current-step condition, the PI+NT+DF strategy further provides anticipatory thermostat regulation and improved transient temperature response. The proposed framework offers a physically interpretable solution for high-precision thermal management of PEMFC systems.
- 28 May 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 12 (26) , 15705-15715
Optimizing the active interface structure of MnO2 to achieve sustainable water oxidation in an acidic medium
Developing cost-effective electrocatalysts for the oxygen evolution reaction (OER) in proton exchange membrane (PEM) water electrolysis is crucial to achieving large-scale hydrogen production through water electrolysis. Here, we propose the utilization of a compound Er2O3 to enhance the catalytic performance of MnO2 in acidic OER. In situ Raman and DFT calculations reveal that Er2O3 not only suppresses the phase transition of MnO2 but also undergoes dissolution at the interface, thereby optimizing the structure of the active catalytic layer. The optimization of the Mn active site through the incorporation of robust Mn–O bonds in the catalytic interface layer, along with the accumulation of active MnO species during OER, are both pivotal factors for enhancing catalytic performance. Due to these inherent advantages, the MnO2@Er2O3 heterostructure catalyst exhibits a low overpotential of 342 ± 5 mV at a current density of 10 mA cm−2. The long-term stability test at a high current density of 50 mA cm−2 for 20 h exhibited no significant performance degradation. This study develops a cost-effective electrocatalyst for acidic OER and provides a new avenue for developing low-cost electrocatalysts for OER under acidic conditions in water electrolysis.
- 28 May 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 12 (26) , 15705-15715
Optimizing the active interface structure of MnO2 to achieve sustainable water oxidation in an acidic medium
Developing cost-effective electrocatalysts for the oxygen evolution reaction (OER) in proton exchange membrane (PEM) water electrolysis is crucial to achieving large-scale hydrogen production through water electrolysis. Here, we propose the utilization of a compound Er2O3 to enhance the catalytic performance of MnO2 in acidic OER. In situ Raman and DFT calculations reveal that Er2O3 not only suppresses the phase transition of MnO2 but also undergoes dissolution at the interface, thereby optimizing the structure of the active catalytic layer. The optimization of the Mn active site through the incorporation of robust Mn–O bonds in the catalytic interface layer, along with the accumulation of active MnO species during OER, are both pivotal factors for enhancing catalytic performance. Due to these inherent advantages, the MnO2@Er2O3 heterostructure catalyst exhibits a low overpotential of 342 ± 5 mV at a current density of 10 mA cm−2. The long-term stability test at a high current density of 50 mA cm−2 for 20 h exhibited no significant performance degradation. This study develops a cost-effective electrocatalyst for acidic OER and provides a new avenue for developing low-cost electrocatalysts for OER under acidic conditions in water electrolysis.
- 22 May 2024
- Published by Springer Nature
- p. 1-10
Study on the Influence of Different Inlet Humidification Temperatures on the PEMFC of Tri-Serpentine Channel
- 22 May 2024
- Published by Springer Nature
- p. 1-10
Study on the Influence of Different Inlet Humidification Temperatures on the PEMFC of Tri-Serpentine Channel
- Open Access
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Study of Liquid‐Cooled Fuel Cell Stack Uniformity considering Global and Local Characteristics under Air Starvation Conditions
Gas starvation significantly affects the uniformity of stack. To reduce this phenomenon, a three‐dimensional, nonisothermal, and two‐phase full‐size liquid‐cooled stack model was developed, and the characteristics of the global and local nonuniformities of oxygen and liquid water in the flow field, membrane temperature, and current density were analyzed under sufficient oxygen supply and three different degrees of gas shortage. Advanced uniformity evaluation criteria (AUEC) were proposed to evaluate the overall uniformity of the stack, which can effectively characterize the local high nonuniformity of the cell units and the differences between edge and intermediate cell units. The results showed that with a decrease in cathode stoichiometric ratio, the AUEC of oxygen, liquid water, membrane temperature, and current density all decreased. The increase in the cooling liquid velocity increased the AUEC of the membrane temperature and current density in the stack, and the AUEC increased further when the oxygen supply was sufficient. In addition, the improvement scheme of GDL gradient porosity was proposed, which can effectively improve the uniformity of each parameter in the stack.
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Open AccessStudy of Liquid‐Cooled Fuel Cell Stack Uniformity considering Global and Local Characteristics under Air Starvation Conditions
Gas starvation significantly affects the uniformity of stack. To reduce this phenomenon, a three‐dimensional, nonisothermal, and two‐phase full‐size liquid‐cooled stack model was developed, and the characteristics of the global and local nonuniformities of oxygen and liquid water in the flow field, membrane temperature, and current density were analyzed under sufficient oxygen supply and three different degrees of gas shortage. Advanced uniformity evaluation criteria (AUEC) were proposed to evaluate the overall uniformity of the stack, which can effectively characterize the local high nonuniformity of the cell units and the differences between edge and intermediate cell units. The results showed that with a decrease in cathode stoichiometric ratio, the AUEC of oxygen, liquid water, membrane temperature, and current density all decreased. The increase in the cooling liquid velocity increased the AUEC of the membrane temperature and current density in the stack, and the AUEC increased further when the oxygen supply was sufficient. In addition, the improvement scheme of GDL gradient porosity was proposed, which can effectively improve the uniformity of each parameter in the stack.
- 19 April 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 21 (3) , 640-650
Characteristics of a composite flow field with drop-shaped gas distribution zones and a honeycomb-like staggered channel for proton exchange membrane fuel cells
On the basis of previous studies, a staggered honeycomb-like flow field with drop-shaped gas distribution zone is proposed in this paper, and the staggered honeycomb-like flow channel can make the oxygen concentration higher, and the drop-shaped gas distribution zone can improve the uniformity of reaction gas in the flow field. A three-dimensional (3D), non-isothermal two-phase numerical model is established to study the flow field performance. First, the reaction gases in the flow field are analyzed, and it is found that the proposed flow field structure can effectively improve the concentration and uniformity of reactants. Second, the volume fraction of liquid water at the (GDL)/channel (CH) interface is analyzed, and it is found that compared with the model of the symmetrical honeycomb channel without considering the gas distribution zone, the proposed model has better water removal effect at the cathode. Finally, the effects of the proposed flow field structure on the membrane properties are discussed. In addition, the temperature uniformity and liquid water removal of PEMFC are improved under the condition of reverse flow of cathode and anode reaction gases. Graphical Abstract
- 19 April 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 21 (3) , 640-650
Characteristics of a composite flow field with drop-shaped gas distribution zones and a honeycomb-like staggered channel for proton exchange membrane fuel cells
On the basis of previous studies, a staggered honeycomb-like flow field with drop-shaped gas distribution zone is proposed in this paper, and the staggered honeycomb-like flow channel can make the oxygen concentration higher, and the drop-shaped gas distribution zone can improve the uniformity of reaction gas in the flow field. A three-dimensional (3D), non-isothermal two-phase numerical model is established to study the flow field performance. First, the reaction gases in the flow field are analyzed, and it is found that the proposed flow field structure can effectively improve the concentration and uniformity of reactants. Second, the volume fraction of liquid water at the (GDL)/channel (CH) interface is analyzed, and it is found that compared with the model of the symmetrical honeycomb channel without considering the gas distribution zone, the proposed model has better water removal effect at the cathode. Finally, the effects of the proposed flow field structure on the membrane properties are discussed. In addition, the temperature uniformity and liquid water removal of PEMFC are improved under the condition of reverse flow of cathode and anode reaction gases. Graphical Abstract
- Open Access
- 30 March 2023
- Published by Wiley in International Journal of Energy Research
- Vol. 2023, 1-12
Thermal Management Analysis of Proton Exchange Membrane Fuel Cell Filled with Phase Change Material in Cooling Channel
Passive thermal management using a phase-change material (PCM) for proton exchange membrane fuel cells (PEMFCs) has been proposed and widely used in the thermal management of Li-ion batteries. A three-dimensional and nonisothermal numerical model of a PEMFC with a PCM cooling channel (PCC) is established in this study. The PCC is better than an air-cooling channel (ACC) in terms of reactant distribution and water removal. Its temperature at the interface of the gas diffusion layer and catalyst layer is lower, and the uniformity of temperature is better. The peak current and power density of the PCC are 4.60% and 5.14% higher than those of the ACC, respectively. Furthermore, the PCC does not increase parasitic power, unlike the ACC. In addition, owing to the high temperature near the outlet, the cooling effects of filling 1/3 PCM and filling 2/3 PCM near the outlet and filling of all PCM are investigated, which shows that the filling of 2/3 PCM provides a better cooling performance.
- 30 March 2023
- Published by Wiley in International Journal of Energy Research
- Vol. 2023, 1-12
Open AccessThermal Management Analysis of Proton Exchange Membrane Fuel Cell Filled with Phase Change Material in Cooling Channel
Passive thermal management using a phase-change material (PCM) for proton exchange membrane fuel cells (PEMFCs) has been proposed and widely used in the thermal management of Li-ion batteries. A three-dimensional and nonisothermal numerical model of a PEMFC with a PCM cooling channel (PCC) is established in this study. The PCC is better than an air-cooling channel (ACC) in terms of reactant distribution and water removal. Its temperature at the interface of the gas diffusion layer and catalyst layer is lower, and the uniformity of temperature is better. The peak current and power density of the PCC are 4.60% and 5.14% higher than those of the ACC, respectively. Furthermore, the PCC does not increase parasitic power, unlike the ACC. In addition, owing to the high temperature near the outlet, the cooling effects of filling 1/3 PCM and filling 2/3 PCM near the outlet and filling of all PCM are investigated, which shows that the filling of 2/3 PCM provides a better cooling performance.
- 14 September 2022
- Published by Springer Nature in Korean Journal of Chemical Engineering
- Vol. 39 (12) , 3434-3441
Study on temperature characteristics of gasoline engine particulate filters during fuel cut-off
- 14 September 2022
- Published by Springer Nature in Korean Journal of Chemical Engineering
- Vol. 39 (12) , 3434-3441
Study on temperature characteristics of gasoline engine particulate filters during fuel cut-off
- Open Access
- 1 October 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 612 (4) , 042005
Impact of wind power grid connection and interline short circuit faults on power grid
With the gradual increase of electricity demand in China, wind power and other power generation has developed rapidly, which makes the structure of power grid more complex. The complex structure increases the risk of short-circuit fault of power grid. The rapid development of wind power intensifies the randomness of power grid operation. This paper uses MATLAB/Simulink to model power system, construct simulation, and analyse the influence of grid-connected wind power and short-circuit faults on grid stability. The results show that the fluctuation and impact of the active power on the user side are significantly weakened compared with those of the single wind power grid when the high-power stable power supply is connected to the wind power grid. The single-phase short-circuit fault has no disturbance to the user of the grid, and the two-phase short-circuit and three-phase short-circuit have greater impact on the voltage, current and speed of the user end.
- 1 October 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 612 (4) , 042005
Open AccessImpact of wind power grid connection and interline short circuit faults on power grid
With the gradual increase of electricity demand in China, wind power and other power generation has developed rapidly, which makes the structure of power grid more complex. The complex structure increases the risk of short-circuit fault of power grid. The rapid development of wind power intensifies the randomness of power grid operation. This paper uses MATLAB/Simulink to model power system, construct simulation, and analyse the influence of grid-connected wind power and short-circuit faults on grid stability. The results show that the fluctuation and impact of the active power on the user side are significantly weakened compared with those of the single wind power grid when the high-power stable power supply is connected to the wind power grid. The single-phase short-circuit fault has no disturbance to the user of the grid, and the two-phase short-circuit and three-phase short-circuit have greater impact on the voltage, current and speed of the user end.