Eva S. Peper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eva S. Peper has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Jessica A. M. Bastiaansen
Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital Bern University Hospital, University of Bern Bern Switzerland
7 shared publications - Bram F. Coolen
Amsterdam University Medical Center
3 shared publications - Gustav J. Strijkers
Department of Biomedical Engineering and Physics, Amsterdam Cardiovascular Sciences, Amsterdam UMC University of Amsterdam Amsterdam The Netherlands
3 shared publications - Jean-Baptiste Ledoux
Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
3 shared publications - Pim van Ooij
Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, the Netherlands
3 shared publications - Aart Johannes Nederveen
Department of Radiology and Nuclear Medicine Amsterdam University Medical Centres Amsterdam The Netherlands
2 shared publications
Latest Publications
- Open Access
- 16 November 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (12)
Fat Fraction Mapping in the Presence of Magnetic Field Inhomogeneities With Phase‐Cycled bSSFP at 3 T
Magnetic field inhomogeneities (Δ B 0 ) can cause fat–water swaps in proton density fat fraction (PDFF) mapping using phase‐cycled balanced steady‐state free‐precession (bSSFP). In this work, a graph‐cuts–based smoothness‐imposing optimization was developed to estimate Δ B 0 from phase‐cycled bSSFP data obtained in fat–water compartments. Data were acquired in phantoms spanning PDFF of 0%–100% to quantify robustness to Δ B 0 and to determine the effect of RF excitation angle ( α ) on PDFF estimation. The approach was further tested in healthy volunteer knee data ( n = 9) and chronic liver disease patients data ( n = 5). Phase‐cycled bSSFP‐based Δ B 0 and PDFF maps were compared with multi‐echo gradient‐echo (MEGRE) reference maps in phantoms and knees. In liver patients, PDFF maps were compared visually and by retrospective ROI analysis with reference quantitative Dixon (qDixon) PDFF maps. Estimated Δ B 0 maps matched the reference, with a root‐mean‐squared error (RMSE) of 9 ± 2 Hz for a Δ B 0 range of ±400 Hz in phantoms and 17 ± 4 Hz for a range of ±150 Hz in knees. PDFF mapping accuracy improved after Δ B 0 correction, with mean RMSE reduced from 35% ± 9% to 3.55% ± 0.92% and mean R 2 increased from 0.29 ± 0.3 to 0.99 ± 0 ( p < 0.0001) across the six phantom experiments (mean ± SD of experiments). PDFF quantification showed significant bias for α = 5°, 40°, and 45° (bias = 2.7%, −2.9%, and −5.8%; p < 0.05), whereas no significant bias was observed for 10° ≤ α ≤ 35° ( p > 0.05). Mean PDFF differences versus MEGRE reference were 2.4% ± 3%, −0.1% ± 0.8%, and 0.2% ± 0.3% for muscle, subcutaneous fat, and bone marrow, respectively. In liver patients, whole‐liver ROI analysis demonstrated a mean PDFF difference of 3% relative to qDixon. Fat–water swaps were successfully removed in knee and patient liver PDFF maps. These results demonstrate that the proposed approach accurately estimates Δ B 0 and mitigates fat–water swaps in phantoms and healthy volunteer knees, while the patient liver study demonstrates the technical feasibility of the proposed framework for phase‐cycled bSSFP‐based PDFF mapping in vivo.
- 16 November 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (12)
Open AccessFat Fraction Mapping in the Presence of Magnetic Field Inhomogeneities With Phase‐Cycled bSSFP at 3 T
Magnetic field inhomogeneities (Δ B 0 ) can cause fat–water swaps in proton density fat fraction (PDFF) mapping using phase‐cycled balanced steady‐state free‐precession (bSSFP). In this work, a graph‐cuts–based smoothness‐imposing optimization was developed to estimate Δ B 0 from phase‐cycled bSSFP data obtained in fat–water compartments. Data were acquired in phantoms spanning PDFF of 0%–100% to quantify robustness to Δ B 0 and to determine the effect of RF excitation angle ( α ) on PDFF estimation. The approach was further tested in healthy volunteer knee data ( n = 9) and chronic liver disease patients data ( n = 5). Phase‐cycled bSSFP‐based Δ B 0 and PDFF maps were compared with multi‐echo gradient‐echo (MEGRE) reference maps in phantoms and knees. In liver patients, PDFF maps were compared visually and by retrospective ROI analysis with reference quantitative Dixon (qDixon) PDFF maps. Estimated Δ B 0 maps matched the reference, with a root‐mean‐squared error (RMSE) of 9 ± 2 Hz for a Δ B 0 range of ±400 Hz in phantoms and 17 ± 4 Hz for a range of ±150 Hz in knees. PDFF mapping accuracy improved after Δ B 0 correction, with mean RMSE reduced from 35% ± 9% to 3.55% ± 0.92% and mean R 2 increased from 0.29 ± 0.3 to 0.99 ± 0 ( p < 0.0001) across the six phantom experiments (mean ± SD of experiments). PDFF quantification showed significant bias for α = 5°, 40°, and 45° (bias = 2.7%, −2.9%, and −5.8%; p < 0.05), whereas no significant bias was observed for 10° ≤ α ≤ 35° ( p > 0.05). Mean PDFF differences versus MEGRE reference were 2.4% ± 3%, −0.1% ± 0.8%, and 0.2% ± 0.3% for muscle, subcutaneous fat, and bone marrow, respectively. In liver patients, whole‐liver ROI analysis demonstrated a mean PDFF difference of 3% relative to qDixon. Fat–water swaps were successfully removed in knee and patient liver PDFF maps. These results demonstrate that the proposed approach accurately estimates Δ B 0 and mitigates fat–water swaps in phantoms and healthy volunteer knees, while the patient liver study demonstrates the technical feasibility of the proposed framework for phase‐cycled bSSFP‐based PDFF mapping in vivo.
- Open Access
Improved 3D Radial Phyllotaxis Trajectories for Uniform Density Distribution of Readout Directions and Sequential Binning
Summary: Purpose: To develop 3D radial spiral phyllotaxis trajectories that provide a uniform density distribution of readout directions and support retrospective sequential binning, thereby reducing ringing artifacts and improving image quality. Methods: UPhy trajectory redefines the polar angle to achieve uniform density distribution of readout directions. FlexiPhy further decouples the azimuthal and polar ordering of interleaves through a randomized permutation, improving robustness to sequential binning. The proposed trajectories were evaluated in vivo on 10 healthy volunteers using two gradient-echo sequences on a 3T MRI scanner. Sequential temporal reconstructions were compared with reference reconstructions using structural similarity and relative L2 error metrics. Results: UPhy presents analytically demonstrated uniform density distribution of readout directions. Quantitative analysis shows significantly higher SSIM values and lower relative L2 errors for FlexiPhy compared with both the original phyllotaxis and UPhy trajectories after Bonferroni correction ( p corrected < 0.05). Conclusion: FlexiPhy enables more reliable sequential binning reconstructions by reducing trajectory-induced ringing artifacts and temporal inconsistencies. Moreover, its randomized construction is not tied to a specific binning strategy, making it broadly compatible with retrospective binning approaches used in dynamic and motion-resolved MRI.
Open AccessImproved 3D Radial Phyllotaxis Trajectories for Uniform Density Distribution of Readout Directions and Sequential Binning
Summary: Purpose: To develop 3D radial spiral phyllotaxis trajectories that provide a uniform density distribution of readout directions and support retrospective sequential binning, thereby reducing ringing artifacts and improving image quality. Methods: UPhy trajectory redefines the polar angle to achieve uniform density distribution of readout directions. FlexiPhy further decouples the azimuthal and polar ordering of interleaves through a randomized permutation, improving robustness to sequential binning. The proposed trajectories were evaluated in vivo on 10 healthy volunteers using two gradient-echo sequences on a 3T MRI scanner. Sequential temporal reconstructions were compared with reference reconstructions using structural similarity and relative L2 error metrics. Results: UPhy presents analytically demonstrated uniform density distribution of readout directions. Quantitative analysis shows significantly higher SSIM values and lower relative L2 errors for FlexiPhy compared with both the original phyllotaxis and UPhy trajectories after Bonferroni correction ( p corrected < 0.05). Conclusion: FlexiPhy enables more reliable sequential binning reconstructions by reducing trajectory-induced ringing artifacts and temporal inconsistencies. Moreover, its randomized construction is not tied to a specific binning strategy, making it broadly compatible with retrospective binning approaches used in dynamic and motion-resolved MRI.
- Open Access
- 4 January 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2627-2643
Pole‐To‐Pole 3D Radial Trajectory Designs Improve Image Quality and Quantitative Parametric Mapping in the Brain and Heart
Purpose: To design 3D radial spiral phyllotaxis trajectories aimed at removing phase inconsistencies, improving image quality, and enhancing parametric mapping accuracy by acquiring nearly opposing spokes starting from both hemispheres in 3D radial k ‐space. Methods: Two 3D radial trajectories, pole‐to‐pole and continuous spiral phyllotaxis, were developed and implemented on a 3T MRI scanner in a phase‐cycled balanced steady‐state free precession (bSSFP) and a spoiled gradient‐echo (GRE) sequence. Image quality and k ‐space center phase variations were evaluated in a spherical phantom using the original and new radial phyllotaxis designs. T1/T2 was quantified and compared using phase‐cycled bSSFP data acquired with the new radial trajectory designs, as well as the original phyllotaxis trajectory and a Cartesian trajectory as references, in both an MRI system phantom and the brains of three healthy volunteers. ECG‐triggered whole‐heart GRE data were acquired using the original and pole‐to‐pole phyllotaxis trajectories in three healthy volunteers and compared for image quality improvement. Results: All 3D radial trajectory designs showed variations in the k ‐space center phase depending on the orientation of the readout spokes. Image quality improved when using the pole‐to‐pole and continuous phyllotaxis over the original trajectory. Scans using the original trajectory had higher T1/T2 estimation errors in comparison to the new trajectories and the Cartesian trajectory. The pole‐to‐pole and continuous trajectories improved T1/T2 maps of the brain and image quality for all cardiac images. Conclusion: Acquiring nearly opposing spokes in 3D radial trajectory designs compensates phase inconsistencies without requiring additional corrections, which improves quantitative imaging and anatomical visualizations.
- 4 January 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2627-2643
Open AccessPole‐To‐Pole 3D Radial Trajectory Designs Improve Image Quality and Quantitative Parametric Mapping in the Brain and Heart
Purpose: To design 3D radial spiral phyllotaxis trajectories aimed at removing phase inconsistencies, improving image quality, and enhancing parametric mapping accuracy by acquiring nearly opposing spokes starting from both hemispheres in 3D radial k ‐space. Methods: Two 3D radial trajectories, pole‐to‐pole and continuous spiral phyllotaxis, were developed and implemented on a 3T MRI scanner in a phase‐cycled balanced steady‐state free precession (bSSFP) and a spoiled gradient‐echo (GRE) sequence. Image quality and k ‐space center phase variations were evaluated in a spherical phantom using the original and new radial phyllotaxis designs. T1/T2 was quantified and compared using phase‐cycled bSSFP data acquired with the new radial trajectory designs, as well as the original phyllotaxis trajectory and a Cartesian trajectory as references, in both an MRI system phantom and the brains of three healthy volunteers. ECG‐triggered whole‐heart GRE data were acquired using the original and pole‐to‐pole phyllotaxis trajectories in three healthy volunteers and compared for image quality improvement. Results: All 3D radial trajectory designs showed variations in the k ‐space center phase depending on the orientation of the readout spokes. Image quality improved when using the pole‐to‐pole and continuous phyllotaxis over the original trajectory. Scans using the original trajectory had higher T1/T2 estimation errors in comparison to the new trajectories and the Cartesian trajectory. The pole‐to‐pole and continuous trajectories improved T1/T2 maps of the brain and image quality for all cardiac images. Conclusion: Acquiring nearly opposing spokes in 3D radial trajectory designs compensates phase inconsistencies without requiring additional corrections, which improves quantitative imaging and anatomical visualizations.
- Open Access
Monalisa: an open source, documented MATLAB toolbox for magnetic resonance imaging reconstruction
Summary: Purpose: An open-source, user-friendly MATLAB framework for Magnetic Resonance Imaging (MRI) reconstruction was developed to simplify the reconstruction process, with a specific focus on non-Cartesian imaging and dynamic applications in the presence of motion. Methods: Monalisa is decomposing the reconstruction pipeline into clear modular steps, including raw data reading with flexible file-type abstraction, trajectory computation, density compensation, advanced coil sensitivity mapping, and tailored binning strategies through its “mitosius” preprocessing stage. The framework supports a suite of reconstruction methods, including iterative-SENSE (also named CG-SENSE), GeneRalized Autocalibrating Partial Parallel Acquisition (GRAPPA) reconstructions, and regularized reconstructions supporting both spatial and temporal regularization using l 1 (Compressed Sensing (CS)) and l 2 techniques, accommodating both Cartesian and non-Cartesian acquisitions. We performed benchmark experiments comparing Monalisa with the Berkeley Advanced Reconstruction Toolbox (BART) toolbox on simulated 2D radial acquisitions. Results: Results of the comparison demonstrate competitive performance, yielding higher Structural Similarity Index (SSIM) and lower l 2 error. Notably, Monalisa reconstructions exhibited fewer visible artifacts than BART. Conclusion: By providing comprehensive documentation, Monalisa serves not only as a powerful tool for research and clinical imaging but also as an educational platform to facilitate innovation in MRI reconstruction.
Open AccessMonalisa: an open source, documented MATLAB toolbox for magnetic resonance imaging reconstruction
Summary: Purpose: An open-source, user-friendly MATLAB framework for Magnetic Resonance Imaging (MRI) reconstruction was developed to simplify the reconstruction process, with a specific focus on non-Cartesian imaging and dynamic applications in the presence of motion. Methods: Monalisa is decomposing the reconstruction pipeline into clear modular steps, including raw data reading with flexible file-type abstraction, trajectory computation, density compensation, advanced coil sensitivity mapping, and tailored binning strategies through its “mitosius” preprocessing stage. The framework supports a suite of reconstruction methods, including iterative-SENSE (also named CG-SENSE), GeneRalized Autocalibrating Partial Parallel Acquisition (GRAPPA) reconstructions, and regularized reconstructions supporting both spatial and temporal regularization using l 1 (Compressed Sensing (CS)) and l 2 techniques, accommodating both Cartesian and non-Cartesian acquisitions. We performed benchmark experiments comparing Monalisa with the Berkeley Advanced Reconstruction Toolbox (BART) toolbox on simulated 2D radial acquisitions. Results: Results of the comparison demonstrate competitive performance, yielding higher Structural Similarity Index (SSIM) and lower l 2 error. Notably, Monalisa reconstructions exhibited fewer visible artifacts than BART. Conclusion: By providing comprehensive documentation, Monalisa serves not only as a powerful tool for research and clinical imaging but also as an educational platform to facilitate innovation in MRI reconstruction.
- 7 December 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 60 (3) , 939-940
Editorial for “Glioma Tumor Grading Using Radiomics on MRI: A Comparative Study of WHO 2021 and WHO 2016 Classification of Central Nervous Tumors”
- 7 December 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 60 (3) , 939-940
Editorial for “Glioma Tumor Grading Using Radiomics on MRI: A Comparative Study of WHO 2021 and WHO 2016 Classification of Central Nervous Tumors”
- Open Access
- 16 June 2023
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 39 (10) , 1963-1977
Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications
Cardiac magnetic resonance (CMR) four-dimensional (4D) flow is a novel method for flow quantification potentially helpful in management of mitral valve regurgitation (MVR). In this systematic review, we aimed to depict the clinical role of intraventricular 4D-flow in MVR. The reproducibility, technical aspects, and comparison against conventional techniques were evaluated. Published studies on SCOPUS, MEDLINE, and EMBASE were included using search terms on 4D-flow CMR in MVR. Out of 420 screened articles, 18 studies fulfilled our inclusion criteria. All studies (n = 18, 100%) assessed MVR using 4D-flow intraventricular annular inflow (4D-flowAIM) method, which calculates the regurgitation by subtracting the aortic forward flow from the mitral forward flow. Thereof, 4D-flow jet quantification (4D-flowjet) was assessed in 5 (28%), standard 2D phase-contrast (2D-PC) flow imaging in 8 (44%) and the volumetric method (the deviation of left ventricle stroke volume and right ventricular stroke volume) in 2 (11%) studies. Inter-method correlations among the 4 MVR quantification methods were heterogeneous across studies, ranging from moderate to excellent correlations. Two studies compared 4D-flowAIM to echocardiography with moderate correlation. In 12 (63%) studies the reproducibility of 4D-flow techniques in quantifying MVR was studied. Thereof, 9 (75%) studies investigated the reproducibility of the 4D-flowAIM method and the majority (n = 7, 78%) reported good to excellent intra- and inter-reader reproducibility. Intraventricular 4D-flowAIM provides high reproducibility with heterogeneous correlations to conventional quantification methods. Due to the absence of a gold standard and unknown accuracies, future longitudinal outcome studies are needed to assess the clinical value of 4D-flow in the clinical setting of MVR.
- 16 June 2023
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 39 (10) , 1963-1977
Open AccessMitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications
Cardiac magnetic resonance (CMR) four-dimensional (4D) flow is a novel method for flow quantification potentially helpful in management of mitral valve regurgitation (MVR). In this systematic review, we aimed to depict the clinical role of intraventricular 4D-flow in MVR. The reproducibility, technical aspects, and comparison against conventional techniques were evaluated. Published studies on SCOPUS, MEDLINE, and EMBASE were included using search terms on 4D-flow CMR in MVR. Out of 420 screened articles, 18 studies fulfilled our inclusion criteria. All studies (n = 18, 100%) assessed MVR using 4D-flow intraventricular annular inflow (4D-flowAIM) method, which calculates the regurgitation by subtracting the aortic forward flow from the mitral forward flow. Thereof, 4D-flow jet quantification (4D-flowjet) was assessed in 5 (28%), standard 2D phase-contrast (2D-PC) flow imaging in 8 (44%) and the volumetric method (the deviation of left ventricle stroke volume and right ventricular stroke volume) in 2 (11%) studies. Inter-method correlations among the 4 MVR quantification methods were heterogeneous across studies, ranging from moderate to excellent correlations. Two studies compared 4D-flowAIM to echocardiography with moderate correlation. In 12 (63%) studies the reproducibility of 4D-flow techniques in quantifying MVR was studied. Thereof, 9 (75%) studies investigated the reproducibility of the 4D-flowAIM method and the majority (n = 7, 78%) reported good to excellent intra- and inter-reader reproducibility. Intraventricular 4D-flowAIM provides high reproducibility with heterogeneous correlations to conventional quantification methods. Due to the absence of a gold standard and unknown accuracies, future longitudinal outcome studies are needed to assess the clinical value of 4D-flow in the clinical setting of MVR.
- Open Access
- 9 December 2022
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 9, 1052068
Advances in machine learning applications for cardiovascular 4D flow MRI
Four-dimensional flow magnetic resonance imaging (MRI) has evolved as a non-invasive imaging technique to visualize and quantify blood flow in the heart and vessels. Hemodynamic parameters derived from 4D flow MRI, such as net flow and peak velocities, but also kinetic energy, turbulent kinetic energy, viscous energy loss, and wall shear stress have shown to be of diagnostic relevance for cardiovascular diseases. 4D flow MRI, however, has several limitations. Its long acquisition times and its limited spatio-temporal resolutions lead to inaccuracies in velocity measurements in small and low-flow vessels and near the vessel wall. Additionally, 4D flow MRI requires long post-processing times, since inaccuracies due to the measurement process need to be corrected for and parameter quantification requires 2D and 3D contour drawing. Several machine learning (ML) techniques have been proposed to overcome these limitations. Existing scan acceleration methods have been extended using ML for image reconstruction and ML based super-resolution methods have been used to assimilate high-resolution computational fluid dynamic simulations and 4D flow MRI, which leads to more realistic velocity results. ML efforts have also focused on the automation of other post-processing steps, by learning phase corrections and anti-aliasing. To automate contour drawing and 3D segmentation, networks such as the U-Net have been widely applied. This review summarizes the latest ML advances in 4D flow MRI with a focus on technical aspects and applications. It is divided into the current status of fast and accurate 4D flow MRI data generation, ML based post-processing tools for phase correction and vessel delineation and the statistical evaluation of blood flow.
- 9 December 2022
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 9, 1052068
Open AccessAdvances in machine learning applications for cardiovascular 4D flow MRI
Four-dimensional flow magnetic resonance imaging (MRI) has evolved as a non-invasive imaging technique to visualize and quantify blood flow in the heart and vessels. Hemodynamic parameters derived from 4D flow MRI, such as net flow and peak velocities, but also kinetic energy, turbulent kinetic energy, viscous energy loss, and wall shear stress have shown to be of diagnostic relevance for cardiovascular diseases. 4D flow MRI, however, has several limitations. Its long acquisition times and its limited spatio-temporal resolutions lead to inaccuracies in velocity measurements in small and low-flow vessels and near the vessel wall. Additionally, 4D flow MRI requires long post-processing times, since inaccuracies due to the measurement process need to be corrected for and parameter quantification requires 2D and 3D contour drawing. Several machine learning (ML) techniques have been proposed to overcome these limitations. Existing scan acceleration methods have been extended using ML for image reconstruction and ML based super-resolution methods have been used to assimilate high-resolution computational fluid dynamic simulations and 4D flow MRI, which leads to more realistic velocity results. ML efforts have also focused on the automation of other post-processing steps, by learning phase corrections and anti-aliasing. To automate contour drawing and 3D segmentation, networks such as the U-Net have been widely applied. This review summarizes the latest ML advances in 4D flow MRI with a focus on technical aspects and applications. It is divided into the current status of fast and accurate 4D flow MRI data generation, ML based post-processing tools for phase correction and vessel delineation and the statistical evaluation of blood flow.
- 22 April 2022
- Published by Springer Nature
- p. 333-348
Magnetic Resonance Imaging-Based 4D Flow: The Role of Artificial Intelligence
- 22 April 2022
- Published by Springer Nature
- p. 333-348
Magnetic Resonance Imaging-Based 4D Flow: The Role of Artificial Intelligence
- 25 June 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (7) , 1201-1208
High Spatiotemporal Resolution 4D Flow MRI of Intracranial Aneurysms at 7T in 10 Minutes
BACKGROUND AND PURPOSE: Patients with intracranial aneurysms may benefit from 4D flow MR imaging because the derived wall shear stress is considered a useful marker for risk assessment and growth of aneurysms. However, long scan times limit the clinical implementation of 4D flow MR imaging. Therefore, this study aimed to investigate whether highly accelerated, high resolution, 4D flow MR imaging at 7T provides reliable quantitative blood flow values in intracranial arteries and aneurysms. MATERIALS AND METHODS: We used pseudospiral Cartesian undersampling with compressed sensing reconstruction to achieve high spatiotemporal resolution (0.5 mm isotropic, ∼30 ms) in a scan time of 10 minutes. We analyzed the repeatability of accelerated 4D flow scans and compared flow rates, stroke volume, and the pulsatility index with 2D flow and conventional 4D flow MR imaging in a flow phantom and 15 healthy subjects. Additionally, accelerated 4D flow MR imaging with high spatiotemporal resolution was acquired in 5 patients with aneurysms to derive wall shear stress. RESULTS: Flow-rate bias compared with 2D flow was lower for accelerated than for conventional 4D flow MR imaging (0.31 ± 0.13, P = .22, versus 0.79 ± 0.17 mL/s, P < .01). Pulsatility index bias gave similar results. Stroke volume bias showed no difference for accelerated as well as for conventional 4D flow compared to 2D flow MR imaging. Repeatability for accelerated 4D flow was similar to that of 2D flow MR imaging. Increased temporal resolution for wall shear stress measurements in 5 intracranial aneurysms did not show a consistent effect for the wall shear stress but did show an effect for the oscillatory shear index. CONCLUSIONS: Highly accelerated high spatiotemporal resolution 4D flow MR imaging at 7T in intracranial arteries and aneurysms provides repeatable and accurate quantitative flow values. Flow rate accuracy is significantly increased compared with conventional 4D flow scans.
- 25 June 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (7) , 1201-1208
High Spatiotemporal Resolution 4D Flow MRI of Intracranial Aneurysms at 7T in 10 Minutes
BACKGROUND AND PURPOSE: Patients with intracranial aneurysms may benefit from 4D flow MR imaging because the derived wall shear stress is considered a useful marker for risk assessment and growth of aneurysms. However, long scan times limit the clinical implementation of 4D flow MR imaging. Therefore, this study aimed to investigate whether highly accelerated, high resolution, 4D flow MR imaging at 7T provides reliable quantitative blood flow values in intracranial arteries and aneurysms. MATERIALS AND METHODS: We used pseudospiral Cartesian undersampling with compressed sensing reconstruction to achieve high spatiotemporal resolution (0.5 mm isotropic, ∼30 ms) in a scan time of 10 minutes. We analyzed the repeatability of accelerated 4D flow scans and compared flow rates, stroke volume, and the pulsatility index with 2D flow and conventional 4D flow MR imaging in a flow phantom and 15 healthy subjects. Additionally, accelerated 4D flow MR imaging with high spatiotemporal resolution was acquired in 5 patients with aneurysms to derive wall shear stress. RESULTS: Flow-rate bias compared with 2D flow was lower for accelerated than for conventional 4D flow MR imaging (0.31 ± 0.13, P = .22, versus 0.79 ± 0.17 mL/s, P < .01). Pulsatility index bias gave similar results. Stroke volume bias showed no difference for accelerated as well as for conventional 4D flow compared to 2D flow MR imaging. Repeatability for accelerated 4D flow was similar to that of 2D flow MR imaging. Increased temporal resolution for wall shear stress measurements in 5 intracranial aneurysms did not show a consistent effect for the wall shear stress but did show an effect for the oscillatory shear index. CONCLUSIONS: Highly accelerated high spatiotemporal resolution 4D flow MR imaging at 7T in intracranial arteries and aneurysms provides repeatable and accurate quantitative flow values. Flow rate accuracy is significantly increased compared with conventional 4D flow scans.