Fan Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fan Yang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Xin Chen
Jiangsu Key Laboratory of New Energy Generation and Power Conversion, Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publications - Ahmed Abu-Siada
Curtin University, Perth, WA, Australia
1 shared publication Donghui Zhang
School of Nanjing University of Aeronautics and Astronautics, Nanjing, China
1 shared publication- Donghui Zhang
Jiangsu Key Laboratory of New Energy Generation and Power Conversion, Nanjing University of Aeronautics and Astronautics, Nanjing, China
1 shared publication - Hong Shen
College of Electrical Engineering, Yanshan University, Qinhaungdao, China
1 shared publication - Tong Huang
Department of Electrical Engineering, Nanjing University of Aeronautics and Astronautics, No.29 Yudao Street, Nangjing 211106, China
1 shared publication
Latest Publications
- 6 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Dynamic Performance Improvement for Brushless Generator System Based on Dynamic Field Current Tracking Method
Due to the presence of large DC-link capacitors in more-electric aircraft (MEA) electric power system (EPS), the brushless synchronous DC generator (BSDG) often fails to meet the dynamic performance requirements of the DC-link voltage under abrupt load changes. As a widely used optimization method, the load current feedforward (LCF) control estimates the required field current under various operating conditions and superimposes it onto the voltage loop output, thereby accelerating its response. However, as the parameters of BSDG are susceptible to variations, the compensated field current may significantly deviate from the actual requirement. To achieve a robust dynamic performance, this paper develops an accurate model of the BSDG’s field current that accounts for the coupling relationship between the DC-link voltage and the load current, as well as the effects of operational parameters and parameter drift. Based on this model, a dynamic field current tracking (DFCT) strategy incorporating full-variable voltage and current feedforward is proposed. This method ensures optimized dynamic performance even under parameter drift conditions. Finally, comparative experiments conducted on a 1 kW brushless generator platform demonstrate the superior dynamic performance of the proposed DFCT method compared with conventional LCF control.
- 6 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Dynamic Performance Improvement for Brushless Generator System Based on Dynamic Field Current Tracking Method
Due to the presence of large DC-link capacitors in more-electric aircraft (MEA) electric power system (EPS), the brushless synchronous DC generator (BSDG) often fails to meet the dynamic performance requirements of the DC-link voltage under abrupt load changes. As a widely used optimization method, the load current feedforward (LCF) control estimates the required field current under various operating conditions and superimposes it onto the voltage loop output, thereby accelerating its response. However, as the parameters of BSDG are susceptible to variations, the compensated field current may significantly deviate from the actual requirement. To achieve a robust dynamic performance, this paper develops an accurate model of the BSDG’s field current that accounts for the coupling relationship between the DC-link voltage and the load current, as well as the effects of operational parameters and parameter drift. Based on this model, a dynamic field current tracking (DFCT) strategy incorporating full-variable voltage and current feedforward is proposed. This method ensures optimized dynamic performance even under parameter drift conditions. Finally, comparative experiments conducted on a 1 kW brushless generator platform demonstrate the superior dynamic performance of the proposed DFCT method compared with conventional LCF control.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 4223-4235
A General Adaptive Stabilization of a Brushless Generator-Based DC Electrical Power System
The escalating integration of constant power loads in advanced DC aircraft electrical power systems introduces critical stability challenges when interfacing with DC three stage brushless generator (DC-TSBG). Traditional capacitance augmentation approaches are high cost under aviation-grade weight and power density constraints. This paper proposes a parameter-independent adaptive stabilization methodology for diode-rectifier-based DC-TSBG systems, addressing both self-stability and source-load interactive stability. Firstly, an enhanced impedance modeling framework capturing the wide frequency-domain characteristics of DC-TSBG is derived, and the stability analysis of a system consisting of DC-TSBG and DC/DC converters is presented. Furthermore, a general adaptive stabilization method of DC-TSBG is proposed, which enables a stable operation of the aircraft power system with a diode rectifier. Experimental verification confirms the precision of the impedance model and the effectiveness of the proposed adaptive stabilization technique.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 4223-4235
A General Adaptive Stabilization of a Brushless Generator-Based DC Electrical Power System
The escalating integration of constant power loads in advanced DC aircraft electrical power systems introduces critical stability challenges when interfacing with DC three stage brushless generator (DC-TSBG). Traditional capacitance augmentation approaches are high cost under aviation-grade weight and power density constraints. This paper proposes a parameter-independent adaptive stabilization methodology for diode-rectifier-based DC-TSBG systems, addressing both self-stability and source-load interactive stability. Firstly, an enhanced impedance modeling framework capturing the wide frequency-domain characteristics of DC-TSBG is derived, and the stability analysis of a system consisting of DC-TSBG and DC/DC converters is presented. Furthermore, a general adaptive stabilization method of DC-TSBG is proposed, which enables a stable operation of the aircraft power system with a diode rectifier. Experimental verification confirms the precision of the impedance model and the effectiveness of the proposed adaptive stabilization technique.
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
- Vol. 12 (1) , 59-72
High-Frequency Stability Analysis and Impedance Optimization for an MMC-HVDC Integrated System Considering Delay Effects
Delay generated by digital control will inevitably lead to negative damping of Modular Multilevel Converter (MMC), which also has significant impacts on the high-frequency stability of the integrated system. Controller parameter optimization is an effectively method for MMC impedance optimization and high-frequency resonance suppression. This paper firstly extends the sequence impedance model of MMC by considering delay effects, and analyzes the high-frequency impedance characteristics as well as the stability of the MMC integrated system. Then, the effect of delay on the frequency range of MMC shows negative damping can be analyzed quantitatively by a vector diagram. Based on the quantified frequency range, the boundary of controller parameters can be derived. Finally, an MMC impedance optimization method that traversal all the values within the derived parameter boundaries to obtain the optimal controller parameters that maximize the phase margin of the system.
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
- Vol. 12 (1) , 59-72
High-Frequency Stability Analysis and Impedance Optimization for an MMC-HVDC Integrated System Considering Delay Effects
Delay generated by digital control will inevitably lead to negative damping of Modular Multilevel Converter (MMC), which also has significant impacts on the high-frequency stability of the integrated system. Controller parameter optimization is an effectively method for MMC impedance optimization and high-frequency resonance suppression. This paper firstly extends the sequence impedance model of MMC by considering delay effects, and analyzes the high-frequency impedance characteristics as well as the stability of the MMC integrated system. Then, the effect of delay on the frequency range of MMC shows negative damping can be analyzed quantitatively by a vector diagram. Based on the quantified frequency range, the boundary of controller parameters can be derived. Finally, an MMC impedance optimization method that traversal all the values within the derived parameter boundaries to obtain the optimal controller parameters that maximize the phase margin of the system.
- Open Access
A New Control Strategy for Active Power Filter
The significant increase in electronic devices has resulted in serious harmonic pollutions in electricity grids. In addition, due to the resonance of the system capacitance and inductance, the harmonic current may be amplified dramatically when it goes through the transmission line which is harmful to the normal operation of electrical equipment. To suppress the voltage and current harmonics resonance, many control strategies of active power filter (APF) are proposed. Nevertheless, these strategies cannot attenuate the amplified harmonic voltage and current due to resonance. In this paper, the harmonic propagation characteristics are investigated on a long transmission line and a new control strategy called VI-APF based on current-controlled and voltage-controlled current sources connected in parallel is presented. According to the simulation results, the proposed control strategy can suppress the total harmonic distortion to a low level. Finally, the effectiveness of VI-APF is demonstrated through the simulation on the IEEE 33-bus distribution system.
Open AccessA New Control Strategy for Active Power Filter
The significant increase in electronic devices has resulted in serious harmonic pollutions in electricity grids. In addition, due to the resonance of the system capacitance and inductance, the harmonic current may be amplified dramatically when it goes through the transmission line which is harmful to the normal operation of electrical equipment. To suppress the voltage and current harmonics resonance, many control strategies of active power filter (APF) are proposed. Nevertheless, these strategies cannot attenuate the amplified harmonic voltage and current due to resonance. In this paper, the harmonic propagation characteristics are investigated on a long transmission line and a new control strategy called VI-APF based on current-controlled and voltage-controlled current sources connected in parallel is presented. According to the simulation results, the proposed control strategy can suppress the total harmonic distortion to a low level. Finally, the effectiveness of VI-APF is demonstrated through the simulation on the IEEE 33-bus distribution system.