William J. Tom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
William J. Tom has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Adrien Ponticorvo
Dept. of Biomed. Eng., Univ. of Texas at Austin, Austin, TX
2 shared publicationsAndrew K. Dunn
University of Texas at Austin
2 shared publicationsA. K. Dunn
Univ. of Texas at Austin (United States)
1 shared publicationAnders M. Dale
Center for Multimodal Imaging and Genetics, University of California, San Diego, La Jolla, CA, United States
1 shared publication- Andrew K. Dunn
The University of Texas at Austin
1 shared publication - Ashwin B. Parthasarathy
University of South Florida, Department of Electrical Engineering, Tampa, Florida, United States
1 shared publication
Latest Publications
- 21 May 2020
- Published by Morressier GmbH
Risk of Aneurysm Development at Intracranial Arterial Fenestrations
Purpose: In prior studies, aneurysms have been identified at the sites of intracranial arterial fenestrations suggesting that intracranial arterial fenestrations are a risk factor for aneurysm formation. However, prior studies being cross-sectional in design have been unable to quantify the risk of developing new aneurysms at arterial fenestrations. Materials and Methods: We
- 21 May 2020
- Published by Morressier GmbH
Risk of Aneurysm Development at Intracranial Arterial Fenestrations
Purpose: In prior studies, aneurysms have been identified at the sites of intracranial arterial fenestrations suggesting that intracranial arterial fenestrations are a risk factor for aneurysm formation. However, prior studies being cross-sectional in design have been unable to quantify the risk of developing new aneurysms at arterial fenestrations. Materials and Methods: We
- Open Access
- 28 January 2020
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 10, 24
Restriction Spectrum Imaging Differentiates True Tumor Progression From Immune-Mediated Pseudoprogression: Case Report of a Patient With Glioblastoma
Immunotherapy is increasingly used in the treatment of glioblastoma (GBM), with immune checkpoint therapy gaining in popularity given favorable outcomes achieved for other tumors. However, immune-mediated (IM)-pseudoprogression is common, remains poorly characterized, and renders conventional imaging of little utility when evaluating for treatment response. We present the case of a 64- year old man with GBM who developed pathologically proven IM-pseudoprogression after initiation of a checkpoint inhibitor, and who subsequently developed true tumor progression at a distant location. Based on both qualitative and quantitative analysis, we demonstrate that an advanced diffusion-weighted imaging (DWI) technique called restriction spectrum imaging (RSI) can differentiate IM-pseudoprogression from true progression even when conventional imaging, including standard DWI/apparent diffusion coefficient (ADC), is not informative. These data complement existing literature supporting the ability of RSI to estimate tumor cellularity, which may help to resolve complex diagnostic challenges such as the identification of IM-pseudoprogression.
- 28 January 2020
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 10, 24
Open AccessRestriction Spectrum Imaging Differentiates True Tumor Progression From Immune-Mediated Pseudoprogression: Case Report of a Patient With Glioblastoma
Immunotherapy is increasingly used in the treatment of glioblastoma (GBM), with immune checkpoint therapy gaining in popularity given favorable outcomes achieved for other tumors. However, immune-mediated (IM)-pseudoprogression is common, remains poorly characterized, and renders conventional imaging of little utility when evaluating for treatment response. We present the case of a 64- year old man with GBM who developed pathologically proven IM-pseudoprogression after initiation of a checkpoint inhibitor, and who subsequently developed true tumor progression at a distant location. Based on both qualitative and quantitative analysis, we demonstrate that an advanced diffusion-weighted imaging (DWI) technique called restriction spectrum imaging (RSI) can differentiate IM-pseudoprogression from true progression even when conventional imaging, including standard DWI/apparent diffusion coefficient (ADC), is not informative. These data complement existing literature supporting the ability of RSI to estimate tumor cellularity, which may help to resolve complex diagnostic challenges such as the identification of IM-pseudoprogression.
- 1 January 2020
- Published by Elsevier in Clinical Imaging
- Vol. 59 (1) , 39-44
Follicular pancreatitis: A rare pancreatic inflammatory pseudotumor
- 1 January 2020
- Published by Elsevier in Clinical Imaging
- Vol. 59 (1) , 39-44
Follicular pancreatitis: A rare pancreatic inflammatory pseudotumor
- 5 February 2014
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 31 (3) , 412-422
Focusing light within turbid media with weakly discriminating filters
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 5 February 2014
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 31 (3) , 412-422
Focusing light within turbid media with weakly discriminating filters
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 16 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 27 (12) , 1728-1738
Efficient Processing of Laser Speckle Contrast Images
Though laser speckle contrast imaging enables the measurement of scattering particle dynamics with high temporal resolution, the subsequent processing has previously been much slower. In prior studies, generating a laser speckle contrast image required about 1 s to process a raw image potentially collected in 10 ms or less. In this paper, novel algorithms are described which are demonstrated to convert 291 raw images per second to laser speckle contrast images and as many as 410 laser speckle contrast images per second to relative correlation time images. As long as image processing occurs during image acquisition, these algorithms render processing time irrelevant in most circumstances and enable real-time imaging of blood flow dynamics.
- 16 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 27 (12) , 1728-1738
Efficient Processing of Laser Speckle Contrast Images
Though laser speckle contrast imaging enables the measurement of scattering particle dynamics with high temporal resolution, the subsequent processing has previously been much slower. In prior studies, generating a laser speckle contrast image required about 1 s to process a raw image potentially collected in 10 ms or less. In this paper, novel algorithms are described which are demonstrated to convert 291 raw images per second to laser speckle contrast images and as many as 410 laser speckle contrast images per second to relative correlation time images. As long as image processing occurs during image acquisition, these algorithms render processing time irrelevant in most circumstances and enable real-time imaging of blood flow dynamics.
- Top Cited Papers
- 1 January 2008
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (3) , 1975-1989
Robust flow measurement with multi-exposure speckle imaging
Laser Speckle Contrast Imaging (LSCI) is a minimally invasive full field optical technique used to generate blood flow maps with high spatial and temporal resolution. The lack of quantitative accuracy and the inability to predict flows in the presence of static scatterers such as an intact or thinned skull have been the primary limitation of LSCI. We present a new Multi-Exposure Speckle Imaging (MESI) instrument that has potential to obtain quantitative baseline flow measures. We show that the MESI instrument extends the range over which relative flow measurements are linear. We also present a new speckle model which can discriminate flows in the presence of static scatters. We show that in the presence of static scatterers the new model used along with the new MESI instrument can predict correlation times of flow consistently to within 10% of the value without static scatterers compared to an average deviation of more than 100% from the value without static scatterers using traditional LSCI. We also show that the new speckle model used with the MESI instrument can maintain the linearity of relative flow measurements in the presence of static scatterers.
- 1 January 2008
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (3) , 1975-1989
Top Cited PapersRobust flow measurement with multi-exposure speckle imaging
Laser Speckle Contrast Imaging (LSCI) is a minimally invasive full field optical technique used to generate blood flow maps with high spatial and temporal resolution. The lack of quantitative accuracy and the inability to predict flows in the presence of static scatterers such as an intact or thinned skull have been the primary limitation of LSCI. We present a new Multi-Exposure Speckle Imaging (MESI) instrument that has potential to obtain quantitative baseline flow measures. We show that the MESI instrument extends the range over which relative flow measurements are linear. We also present a new speckle model which can discriminate flows in the presence of static scatters. We show that in the presence of static scatterers the new model used along with the new MESI instrument can predict correlation times of flow consistently to within 10% of the value without static scatterers compared to an average deviation of more than 100% from the value without static scatterers using traditional LSCI. We also show that the new speckle model used with the MESI instrument can maintain the linearity of relative flow measurements in the presence of static scatterers.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6446, 64460U-64460
Imaging hemodynamic effects of ET-1 on cerebral blood flow in rats
Endothelin-1 (ET-1) is a potent vasoconstrictor sometimes used in studies of cerebral ischemia. Its ability to create ischemic regions of various sizes with little additional damage has made it a popular tool in evaluating anti-stroke drugs. Despite its emergence in stroke models, it remains poorly characterized. Attempts to do this with Laser Doppler Flowmetry (LDF) or a histological analysis provide good temporal resolution or good spatial resolution respectively, but not both. An imaging modality that provides both temporal and spatial resolution would be able to better characterize the acute and chronic effects of ET-1 on cerebral blood flow. We have used laser speckle contrast imaging to study the effects of ET-1 after topical application on rats. We observed an immediate decrease in blood flow corresponding to the amount of ET-1 used. After the initial decrease, the blood flow slowly increases towards the baseline value with occasional vasospastic responses observed. Future studies involving multi-spectral reflectance imaging combined with the laser speckle contrast analysis would lead to a better understanding of the hemodynamic effects of ET-1.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6446, 64460U-64460
Imaging hemodynamic effects of ET-1 on cerebral blood flow in rats
Endothelin-1 (ET-1) is a potent vasoconstrictor sometimes used in studies of cerebral ischemia. Its ability to create ischemic regions of various sizes with little additional damage has made it a popular tool in evaluating anti-stroke drugs. Despite its emergence in stroke models, it remains poorly characterized. Attempts to do this with Laser Doppler Flowmetry (LDF) or a histological analysis provide good temporal resolution or good spatial resolution respectively, but not both. An imaging modality that provides both temporal and spatial resolution would be able to better characterize the acute and chronic effects of ET-1 on cerebral blood flow. We have used laser speckle contrast imaging to study the effects of ET-1 after topical application on rats. We observed an immediate decrease in blood flow corresponding to the amount of ET-1 used. After the initial decrease, the blood flow slowly increases towards the baseline value with occasional vasospastic responses observed. Future studies involving multi-spectral reflectance imaging combined with the laser speckle contrast analysis would lead to a better understanding of the hemodynamic effects of ET-1.