Lucie Delaroche
Research Subjects
Lucie Delaroche has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Fabienne Bazin
HORIANA, Bordeaux, France
3 shared publicationsLucile Besnard
Biogroup Paris Sud, Laboratoire d’AMP, Hôpital Privé de Parly 2, Le Chesnay Rocquencourt, France
3 shared publicationsEmmanuel Genauzeau
Affiliations Ramsay Santé, Hôpital Privé de Parly 2, Institut Fertilité Maternité Parly 2, Le Chesnay, France, Centre de Biologie Médicale, Hôpital Privé de Parly 2, Le Chesnay, France
2 shared publicationsFrédéric Lamazou
Affiliation Ramsay Santé, Hôpital Privé de Parly 2, Institut Fertilité Maternité Parly 2, Le Chesnay, France
2 shared publicationsPhilippe Meicler
Affiliation Ramsay Santé, Hôpital Privé de Parly 2, Institut Fertilité Maternité Parly 2, Le Chesnay, France
2 shared publicationsPierre Oger
Affiliation Ramsay Santé, Hôpital Privé de Parly 2, Institut Fertilité Maternité Parly 2, Le Chesnay, France
2 shared publications
Latest Publications
- Open Access
- 20 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
The sequential use of IVF disposable devices doesn’t cause cumulative toxicity unless a defective device compromises the entire procedure
This study investigated whether the sequential use of disposable devices in routine IVF procedures induces cumulative embryotoxicity. Ten combinations, each including 7 to 25 disposables covering essential IVF steps—sperm collection, oocyte retrieval, fertilization, embryo culture, transfer, and freezing/thawing—were tested using the Mouse Embryo Assay (MEA) in triplicate. A defined volume of culture medium was employed to extract potential toxic compounds from device associations. Both extracts and controls underwent MEA. Fresh zygotes were cultured for 120 h at 37.3 °C in a tri-gas incubator. Embryo development was monitored morphologically at E1.5, E4.0, and E5.0. At E5.0, blastocysts were fixed and analyzed for total cell counts. Of the ten tested combinations, two (20%) demonstrated toxicity, evidenced by reduced blastocyst formation and lower cell numbers at E5.0. Toxicity was attributed to specific consumables—sperm straws and embryo transfer catheters—rather than cumulative effects. Although previously certified as non-toxic, these devices were found harmful both individually and in combination. Variability in MEA protocols may explain inconsistencies in manufacturer assessments. The study concludes that sequential disposable use does not inherently cause cumulative toxicity unless a defective device intervenes, emphasizing the need for standardized preclinical MEA testing to ensure embryo safety and optimize IVF outcomes.
- 20 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessThe sequential use of IVF disposable devices doesn’t cause cumulative toxicity unless a defective device compromises the entire procedure
This study investigated whether the sequential use of disposable devices in routine IVF procedures induces cumulative embryotoxicity. Ten combinations, each including 7 to 25 disposables covering essential IVF steps—sperm collection, oocyte retrieval, fertilization, embryo culture, transfer, and freezing/thawing—were tested using the Mouse Embryo Assay (MEA) in triplicate. A defined volume of culture medium was employed to extract potential toxic compounds from device associations. Both extracts and controls underwent MEA. Fresh zygotes were cultured for 120 h at 37.3 °C in a tri-gas incubator. Embryo development was monitored morphologically at E1.5, E4.0, and E5.0. At E5.0, blastocysts were fixed and analyzed for total cell counts. Of the ten tested combinations, two (20%) demonstrated toxicity, evidenced by reduced blastocyst formation and lower cell numbers at E5.0. Toxicity was attributed to specific consumables—sperm straws and embryo transfer catheters—rather than cumulative effects. Although previously certified as non-toxic, these devices were found harmful both individually and in combination. Variability in MEA protocols may explain inconsistencies in manufacturer assessments. The study concludes that sequential disposable use does not inherently cause cumulative toxicity unless a defective device intervenes, emphasizing the need for standardized preclinical MEA testing to ensure embryo safety and optimize IVF outcomes.
- Open Access
- 4 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Over one-third of professionals in French ART centers experience job strain
This study aimed to evaluate the level of strain experienced by professionals across 104 French assisted reproductive technology (ART) centers. A cross-sectional survey was conducted from November 2023 to January 2024, using an online questionnaire based on Karasek’s and Siegrist’s models to assess psychological demands, decision latitude, social support, and the balance between efforts and rewards. Additional questions collected personal and professional details. Job strain was defined by high demands and low decision latitude, while iso-strain also included low social support. Effort-reward imbalance (ERI) referred to a situation where individuals experience high effort in their work but perceive the rewards as insufficient. The study included 464 participants (13% participation rate), comprising biologists (n = 124, 26.7%), gynecologists (n = 129, 27.8%), technicians (n = 107, 23.1%), secretaries (n = 51, 11.0%), midwives (n = 31, 6.7%), and other professions (n = 22, 4.7%). We found that 35.7% of professionals in French ART centers experienced job strain, with 20.9% in an iso-strain situation and 14.9% showing an imbalance between efforts and rewards. Multivariate logistic regression analysis revealed a significant impact of occupational roles on job strain, with secretaries (OR 9.76 [3.70; 25.78]) and technicians (OR 8.62 [3.45; 21.53]) facing a higher risk compared to gynecologists. A strong correlation was found between perceived work stress or job satisfaction and the risk of job strain, iso-strain, and ERI. In conclusion, our study revealed that over a third of French ART professionals experienced job strain, a condition linked to increased risks of stress, burnout, and health concerns. Secretaries and technicians appeared particularly vulnerable, highlighting the need for targeted interventions. Future research should aim to identify specific stressors and protective factors to help create tailored support programs that promote staff well-being.
- 4 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Open AccessOver one-third of professionals in French ART centers experience job strain
This study aimed to evaluate the level of strain experienced by professionals across 104 French assisted reproductive technology (ART) centers. A cross-sectional survey was conducted from November 2023 to January 2024, using an online questionnaire based on Karasek’s and Siegrist’s models to assess psychological demands, decision latitude, social support, and the balance between efforts and rewards. Additional questions collected personal and professional details. Job strain was defined by high demands and low decision latitude, while iso-strain also included low social support. Effort-reward imbalance (ERI) referred to a situation where individuals experience high effort in their work but perceive the rewards as insufficient. The study included 464 participants (13% participation rate), comprising biologists (n = 124, 26.7%), gynecologists (n = 129, 27.8%), technicians (n = 107, 23.1%), secretaries (n = 51, 11.0%), midwives (n = 31, 6.7%), and other professions (n = 22, 4.7%). We found that 35.7% of professionals in French ART centers experienced job strain, with 20.9% in an iso-strain situation and 14.9% showing an imbalance between efforts and rewards. Multivariate logistic regression analysis revealed a significant impact of occupational roles on job strain, with secretaries (OR 9.76 [3.70; 25.78]) and technicians (OR 8.62 [3.45; 21.53]) facing a higher risk compared to gynecologists. A strong correlation was found between perceived work stress or job satisfaction and the risk of job strain, iso-strain, and ERI. In conclusion, our study revealed that over a third of French ART professionals experienced job strain, a condition linked to increased risks of stress, burnout, and health concerns. Secretaries and technicians appeared particularly vulnerable, highlighting the need for targeted interventions. Future research should aim to identify specific stressors and protective factors to help create tailored support programs that promote staff well-being.
- Open Access
- 29 August 2024
- Published by Elsevier in Reproductive BioMedicine Online
- Vol. 50 (1) , 104431
Assessment of bisphenol accumulation from disposable devices used sequentially in IVF routine procedures
- 29 August 2024
- Published by Elsevier in Reproductive BioMedicine Online
- Vol. 50 (1) , 104431
Open AccessAssessment of bisphenol accumulation from disposable devices used sequentially in IVF routine procedures
- Open Access
- 4 March 2024
- Published by Oxford University Press (OUP) in Human Reproduction
- Vol. 39 (5) , 936-954
Disposables used cumulatively in routine IVF procedures could display toxicity
Is there a cumulative toxicity of disposables used in IVF procedures? A toxicity may be detected when consumables are used cumulatively, while no toxicity is detected when the same consumables are used and tested individually. Many components of items used in IVF laboratories may impair human embryonic development. Consequently, it is necessary to screen all reagents and materials which could be in contact with gametes and embryos. Toxicity tests, such as the mouse embryo assay and the human sperm motility assay (HSMA), are used by manufacturers as quality control tools to demonstrate the safety of their products. This evaluation is currently individually performed for each single consumable. However, during an IVF cycle, several devices are used sequentially, potentially creating a cumulative exposure to chemical contaminants, which could not be detected for individually tested consumables. The objective of this observational study conducted from March 2021 to October 2022 was to evaluate with the HSMA methodology if there was a cumulative toxicity when several disposables are sequentially used. Fourteen categories of consumables currently used in routine IVF procedures were studied, which included devices used for sperm and oocyte collection (cups, condoms, and oocyte aspiration needles), manipulation (flasks, tubes, tips, pipettes, embryo transfer catheters, syringes, and gloves), culture (dishes), and storage (straws). After obtaining patient consent, the surplus semen assessed as having normal parameters according to the World Health Organization 2010 criteria were used to perform the HSMAs. First, each consumable was tested individually. Then, associations of three, four, and five consumables, previously validated as non-toxic when tested individually, were analyzed. HSMAs were conducted three times to ensure reproducibility, with a defined toxicity threshold of a sperm motility index (SMI) below 0.85 in at least two of three tests. Thirty-six references of disposables were first individually tested across 53 lots. Forty-nine (92%) demonstrated compliance. However, four (8%) devices revealed toxicity: one lot of 1 ml syringes, two lots of sperm cups, and one lot of 25 cm2 flasks. These four references were excluded from the IVF routine procedures. A total of 48 combinations of consumables were assessed, involving 41 lots from 32 references that were previously individually tested. Among the evaluated combinations, 17 out of 48 (35%) associations exhibited toxicity with a SMI below 0.85 for two of the three tests (n = 8) or all the three tests (n = 9). Notably, three out of 17 (18%) of the three-consumable associations, five out of 16 (31%) of the four-consumable associations, and nine out of 15 (60%) of the five-consumable associations were found not compliant. The toxicity did not originate from a single consumable, because only consumables that were individually pre-validated as non-toxic were included in the combinations, but the toxicity had a cumulative origin. The risk of cumulative toxicity increased with the number of consumables included in the association (Cochran–Mantel–Haenszel statistic, P = 0.013). The high proportion of non-compliant combinations of disposables can be attributed directly to the extreme rigorous extraction conditions employed during the tests, which could deviate from the conditions encountered in routine clinical use. Also, the methodology employed in the HSMAs (e.g. toxicity extraction duration, sperm concentrations, and protein supplementation of the medium) can influence the sensitivity of the tests. This study highlights the significance of performing toxicity testing on devices before introducing them into clinical practice. Disposables should be tested individually to detect immediate toxicities and also in combination. Our results advocate rationalizing the number of consumables used in each IVF procedure and re-evaluating the use of glass consumables. This study received fundings from GCS Ramsay Santé pour l’Enseignement et la Recherche (Paris, France) and the Centre de Biologie Médicale BIOGROUP (Le Chesnay-Rocquencourt, France). The authors declare that they have no conflict of interest that could be perceived as prejudicing the impartiality of the reported research. N/A.
- 4 March 2024
- Published by Oxford University Press (OUP) in Human Reproduction
- Vol. 39 (5) , 936-954
Open AccessDisposables used cumulatively in routine IVF procedures could display toxicity
Is there a cumulative toxicity of disposables used in IVF procedures? A toxicity may be detected when consumables are used cumulatively, while no toxicity is detected when the same consumables are used and tested individually. Many components of items used in IVF laboratories may impair human embryonic development. Consequently, it is necessary to screen all reagents and materials which could be in contact with gametes and embryos. Toxicity tests, such as the mouse embryo assay and the human sperm motility assay (HSMA), are used by manufacturers as quality control tools to demonstrate the safety of their products. This evaluation is currently individually performed for each single consumable. However, during an IVF cycle, several devices are used sequentially, potentially creating a cumulative exposure to chemical contaminants, which could not be detected for individually tested consumables. The objective of this observational study conducted from March 2021 to October 2022 was to evaluate with the HSMA methodology if there was a cumulative toxicity when several disposables are sequentially used. Fourteen categories of consumables currently used in routine IVF procedures were studied, which included devices used for sperm and oocyte collection (cups, condoms, and oocyte aspiration needles), manipulation (flasks, tubes, tips, pipettes, embryo transfer catheters, syringes, and gloves), culture (dishes), and storage (straws). After obtaining patient consent, the surplus semen assessed as having normal parameters according to the World Health Organization 2010 criteria were used to perform the HSMAs. First, each consumable was tested individually. Then, associations of three, four, and five consumables, previously validated as non-toxic when tested individually, were analyzed. HSMAs were conducted three times to ensure reproducibility, with a defined toxicity threshold of a sperm motility index (SMI) below 0.85 in at least two of three tests. Thirty-six references of disposables were first individually tested across 53 lots. Forty-nine (92%) demonstrated compliance. However, four (8%) devices revealed toxicity: one lot of 1 ml syringes, two lots of sperm cups, and one lot of 25 cm2 flasks. These four references were excluded from the IVF routine procedures. A total of 48 combinations of consumables were assessed, involving 41 lots from 32 references that were previously individually tested. Among the evaluated combinations, 17 out of 48 (35%) associations exhibited toxicity with a SMI below 0.85 for two of the three tests (n = 8) or all the three tests (n = 9). Notably, three out of 17 (18%) of the three-consumable associations, five out of 16 (31%) of the four-consumable associations, and nine out of 15 (60%) of the five-consumable associations were found not compliant. The toxicity did not originate from a single consumable, because only consumables that were individually pre-validated as non-toxic were included in the combinations, but the toxicity had a cumulative origin. The risk of cumulative toxicity increased with the number of consumables included in the association (Cochran–Mantel–Haenszel statistic, P = 0.013). The high proportion of non-compliant combinations of disposables can be attributed directly to the extreme rigorous extraction conditions employed during the tests, which could deviate from the conditions encountered in routine clinical use. Also, the methodology employed in the HSMAs (e.g. toxicity extraction duration, sperm concentrations, and protein supplementation of the medium) can influence the sensitivity of the tests. This study highlights the significance of performing toxicity testing on devices before introducing them into clinical practice. Disposables should be tested individually to detect immediate toxicities and also in combination. Our results advocate rationalizing the number of consumables used in each IVF procedure and re-evaluating the use of glass consumables. This study received fundings from GCS Ramsay Santé pour l’Enseignement et la Recherche (Paris, France) and the Centre de Biologie Médicale BIOGROUP (Le Chesnay-Rocquencourt, France). The authors declare that they have no conflict of interest that could be perceived as prejudicing the impartiality of the reported research. N/A.
- Open Access
- 14 December 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (12) , e0260187
Evaluation of SARS-CoV-2 in semen, seminal plasma, and spermatozoa pellet of COVID-19 patients in the acute stage of infection
To date, there is limited information about the presence of SARS-CoV-2 in semen especially in the acute phase of the infection. While available data from cohort studies including a total of 342 patients in the acute or recovery phase of the infection are reassuring, one study mentioned detecting virus in the semen of 6/38 COVID-19 patients. Here we assessed SARS-CoV-2 presence in the semen of COVID-19 positive patients in the acute stage of infection, within 24 hours of the positive nasopharyngeal swabs. Semen, seminal plasma and spermatozoa pellet were screened for SARS-CoV-2 and manual or airborne contamination during semen sampling. Among the 32 COVID-19 volunteers, the median interval from the onset of symptoms to semen collection was 4 days [IQR: 0–8]. Only one presented positive SARS-CoV-2 PCR in semen and seminal plasma fractions, although the spermatozoa pellet was negative. Viral cultures were all negative. We observed slightly higher concentrations of bacterial DNA in the SARS-CoV-2 positive specimen than in all negative samples. The bacteria identified neither confirm nor rule out contamination by oropharyngeal secretions during collection. SARS-CoV-2 was rarely present in semen during the acute phase of the disease. This very rare situation could be connected to oral or manual contamination during semen collection. The possible presence of SARS-CoV-2 in semen calls for nasopharyngeal viral testing and strict hygiene protocols during semen collection before assisted reproductive attempts.
- 14 December 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (12) , e0260187
Open AccessEvaluation of SARS-CoV-2 in semen, seminal plasma, and spermatozoa pellet of COVID-19 patients in the acute stage of infection
To date, there is limited information about the presence of SARS-CoV-2 in semen especially in the acute phase of the infection. While available data from cohort studies including a total of 342 patients in the acute or recovery phase of the infection are reassuring, one study mentioned detecting virus in the semen of 6/38 COVID-19 patients. Here we assessed SARS-CoV-2 presence in the semen of COVID-19 positive patients in the acute stage of infection, within 24 hours of the positive nasopharyngeal swabs. Semen, seminal plasma and spermatozoa pellet were screened for SARS-CoV-2 and manual or airborne contamination during semen sampling. Among the 32 COVID-19 volunteers, the median interval from the onset of symptoms to semen collection was 4 days [IQR: 0–8]. Only one presented positive SARS-CoV-2 PCR in semen and seminal plasma fractions, although the spermatozoa pellet was negative. Viral cultures were all negative. We observed slightly higher concentrations of bacterial DNA in the SARS-CoV-2 positive specimen than in all negative samples. The bacteria identified neither confirm nor rule out contamination by oropharyngeal secretions during collection. SARS-CoV-2 was rarely present in semen during the acute phase of the disease. This very rare situation could be connected to oral or manual contamination during semen collection. The possible presence of SARS-CoV-2 in semen calls for nasopharyngeal viral testing and strict hygiene protocols during semen collection before assisted reproductive attempts.
- 1 January 2021
- Published by Elsevier in Reproductive BioMedicine Online
- Vol. 42 (1) , 117-124
Live birth after intrauterine insemination: is there an upper cut-off for the number of motile spermatozoa inseminated?
- 1 January 2021
- Published by Elsevier in Reproductive BioMedicine Online
- Vol. 42 (1) , 117-124
Live birth after intrauterine insemination: is there an upper cut-off for the number of motile spermatozoa inseminated?