Dimitar D. Deliyski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dimitar D. Deliyski has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Hamzeh Ghasemzadeh
Voice and Speech Informatics Lab, School of Communication Sciences and Disorders, University of Central Florida, Orlando
2 shared publications - Maryam Naghibolhosseini
Department of Communicative Sciences and Disorders, Michigan State University, East Lansing, Michigan
2 shared publications - Stephanie R. C. Zacharias
Center for Pediatric Voice Disorders, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio; Division of Speech-Language Pathology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio; Department of Otolaryngology Head & Neck Surgery, University of Cincinnati, Ohio; Division of Pediatric Otolaryngology-Head and Neck Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio
2 shared publications - Ahmed M. Yousef
Department of Communicative Sciences and Disorders, Michigan State University, East Lansing, Michigan
1 shared publication Alessandro de Alarcon
Cincinnati Childrens Hosp Med Ctr, Div Pediat Otolaryngol, Cincinnati, OH 45229 USA
1 shared publication- Alessandro de Alarcon
Department of Otolaryngology‐Head and Neck Surgery University of Cincinnati Cincinnati Ohio USA
1 shared publication
Latest Publications
- Open Access
- 25 February 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (5) , 2979
Laryngeal Imaging Study of Glottal Attack/Offset Time in Adductor Spasmodic Dysphonia during Connected Speech
Adductor spasmodic dysphonia (AdSD) disrupts laryngeal muscle control during speech and, therefore, affects the onset and offset of phonation. In this study, the goal is to use laryngeal high-speed videoendoscopy (HSV) to measure the glottal attack time (GAT) and glottal offset time (GOT) during connected speech for normophonic (vocally normal) and AdSD voices. A monochrome HSV system was used to record readings of six CAPE-V sentences and part of the “Rainbow Passage” from the participants. Three raters visually analyzed the HSV data using a playback software to measure the GAT and GOT. The results show that the GAT was greater in the AdSD group than in the normophonic group; however, the clinical significance of the amount of this difference needs to be studied further. More variability was observed in both GATs and GOTs of the disorder group. Additionally, the GAT and GOT time series were found to be nonstationary for the AdSD group while they were stationary for the normophonic voices. This study shows that the GAT and GOT measures can be potentially used as objective markers to characterize AdSD. The findings will potentially help in the development of standardized measures for voice evaluation and the accurate diagnosis of AdSD.
- 25 February 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (5) , 2979
Open AccessLaryngeal Imaging Study of Glottal Attack/Offset Time in Adductor Spasmodic Dysphonia during Connected Speech
Adductor spasmodic dysphonia (AdSD) disrupts laryngeal muscle control during speech and, therefore, affects the onset and offset of phonation. In this study, the goal is to use laryngeal high-speed videoendoscopy (HSV) to measure the glottal attack time (GAT) and glottal offset time (GOT) during connected speech for normophonic (vocally normal) and AdSD voices. A monochrome HSV system was used to record readings of six CAPE-V sentences and part of the “Rainbow Passage” from the participants. Three raters visually analyzed the HSV data using a playback software to measure the GAT and GOT. The results show that the GAT was greater in the AdSD group than in the normophonic group; however, the clinical significance of the amount of this difference needs to be studied further. More variability was observed in both GATs and GOTs of the disorder group. Additionally, the GAT and GOT time series were found to be nonstationary for the AdSD group while they were stationary for the normophonic voices. This study shows that the GAT and GOT measures can be potentially used as objective markers to characterize AdSD. The findings will potentially help in the development of standardized measures for voice evaluation and the accurate diagnosis of AdSD.
- 1 November 2022
- Published by Elsevier in Journal of Voice
- Vol. 36 (6) , 755-769
Non-Linear Image Distortions in Flexible Fiberoptic Endoscopes and their Effects on Calibrated Horizontal Measurements Using High-Speed Videoendoscopy
- 1 November 2022
- Published by Elsevier in Journal of Voice
- Vol. 36 (6) , 755-769
Non-Linear Image Distortions in Flexible Fiberoptic Endoscopes and their Effects on Calibrated Horizontal Measurements Using High-Speed Videoendoscopy
- Open Access
- 27 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (3) , 1179
A Hybrid Machine-Learning-Based Method for Analytic Representation of the Vocal Fold Edges during Connected Speech
Investigating the phonatory processes in connected speech from high-speed videoendoscopy (HSV) demands the accurate detection of the vocal fold edges during vibration. The present paper proposes a new spatio-temporal technique to automatically segment vocal fold edges in HSV data during running speech. The HSV data were recorded from a vocally normal adult during a reading of the “Rainbow Passage.” The introduced technique was based on an unsupervised machine-learning (ML) approach combined with an active contour modeling (ACM) technique (also known as a hybrid approach). The hybrid method was implemented to capture the edges of vocal folds on different HSV kymograms, extracted at various cross-sections of vocal folds during vibration. The k-means clustering method, an ML approach, was first applied to cluster the kymograms to identify the clustered glottal area and consequently provided an initialized contour for the ACM. The ACM algorithm was then used to precisely detect the glottal edges of the vibrating vocal folds. The developed algorithm was able to accurately track the vocal fold edges across frames with low computational cost and high robustness against image noise. This algorithm offers a fully automated tool for analyzing the vibratory features of vocal folds in connected speech.
- 27 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (3) , 1179
Open AccessA Hybrid Machine-Learning-Based Method for Analytic Representation of the Vocal Fold Edges during Connected Speech
Investigating the phonatory processes in connected speech from high-speed videoendoscopy (HSV) demands the accurate detection of the vocal fold edges during vibration. The present paper proposes a new spatio-temporal technique to automatically segment vocal fold edges in HSV data during running speech. The HSV data were recorded from a vocally normal adult during a reading of the “Rainbow Passage.” The introduced technique was based on an unsupervised machine-learning (ML) approach combined with an active contour modeling (ACM) technique (also known as a hybrid approach). The hybrid method was implemented to capture the edges of vocal folds on different HSV kymograms, extracted at various cross-sections of vocal folds during vibration. The k-means clustering method, an ML approach, was first applied to cluster the kymograms to identify the clustered glottal area and consequently provided an initialized contour for the ACM. The ACM algorithm was then used to precisely detect the glottal edges of the vibrating vocal folds. The developed algorithm was able to accurately track the vocal fold edges across frames with low computational cost and high robustness against image noise. This algorithm offers a fully automated tool for analyzing the vibratory features of vocal folds in connected speech.
- Open Access
- 17 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (2) , 822
Method for Horizontal Calibration of Laser-Projection Transnasal Fiberoptic High-Speed Videoendoscopy
Objective: Calibrated horizontal measurements (e.g., mm) from endoscopic procedures could be utilized for advancement of evidence-based practice and personalized medicine. However, the size of an object in endoscopic images is not readily calibrated and depends on multiple factors, including the distance between the endoscope and the target surface. Additionally, acquired images may have significant non-linear distortion that would further complicate calibrated measurements. This study used a recently developed in vivo laser-projection fiberoptic laryngoscope and proposes a method for calibrated spatial measurements. Method: A set of circular grids was recorded at multiple working distances. A statistical model was trained that would map from pixel length of the object, the working distance, and the spatial location of the target object into its mm length. Result: A detailed analysis of the performance of the proposed method is presented. The analyses have shown that the accuracy of the proposed method does not depend on the working distance and length of the target object. The estimated average magnitude of error was 0.27 mm, which is three times lower than the existing alternative. Conclusion: The presented method can achieve sub-millimeter accuracy in horizontal measurement. Significance: Evidence-based practice and personalized medicine could significantly benefit from the proposed method. Implications of the findings for other endoscopic procedures are also discussed.
- 17 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (2) , 822
Open AccessMethod for Horizontal Calibration of Laser-Projection Transnasal Fiberoptic High-Speed Videoendoscopy
Objective: Calibrated horizontal measurements (e.g., mm) from endoscopic procedures could be utilized for advancement of evidence-based practice and personalized medicine. However, the size of an object in endoscopic images is not readily calibrated and depends on multiple factors, including the distance between the endoscope and the target surface. Additionally, acquired images may have significant non-linear distortion that would further complicate calibrated measurements. This study used a recently developed in vivo laser-projection fiberoptic laryngoscope and proposes a method for calibrated spatial measurements. Method: A set of circular grids was recorded at multiple working distances. A statistical model was trained that would map from pixel length of the object, the working distance, and the spatial location of the target object into its mm length. Result: A detailed analysis of the performance of the proposed method is presented. The analyses have shown that the accuracy of the proposed method does not depend on the working distance and length of the target object. The estimated average magnitude of error was 0.27 mm, which is three times lower than the existing alternative. Conclusion: The presented method can achieve sub-millimeter accuracy in horizontal measurement. Significance: Evidence-based practice and personalized medicine could significantly benefit from the proposed method. Implications of the findings for other endoscopic procedures are also discussed.
- 1 January 2021
- Published by Elsevier in Journal of Voice
- Vol. 35 (1) , 122-128
Laser-Calibrated System for Transnasal Fiberoptic Laryngeal High-Speed Videoendoscopy
- 1 January 2021
- Published by Elsevier in Journal of Voice
- Vol. 35 (1) , 122-128
Laser-Calibrated System for Transnasal Fiberoptic Laryngeal High-Speed Videoendoscopy
- Open Access
- 25 February 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (5) , 1556
Laryngeal Image Processing of Vocal Folds Motion
This review provides a comprehensive compilation, from a digital image processing point of view of the most important techniques currently developed to characterize and quantify the vibration behaviour of the vocal folds, along with a detailed description of the laryngeal image modalities currently used in the clinic. The review presents an overview of the most significant glottal-gap segmentation and facilitative playbacks techniques used in the literature for the mentioned purpose, and shows the drawbacks and challenges that still remain unsolved to develop robust vocal folds vibration function analysis tools based on digital image processing.
- 25 February 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (5) , 1556
Open AccessLaryngeal Image Processing of Vocal Folds Motion
This review provides a comprehensive compilation, from a digital image processing point of view of the most important techniques currently developed to characterize and quantify the vibration behaviour of the vocal folds, along with a detailed description of the laryngeal image modalities currently used in the clinic. The review presents an overview of the most significant glottal-gap segmentation and facilitative playbacks techniques used in the literature for the mentioned purpose, and shows the drawbacks and challenges that still remain unsolved to develop robust vocal folds vibration function analysis tools based on digital image processing.