Daniel M.G. Winson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Daniel M.G. Winson has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Anne-Marie Hutchinson
Physiotherapy Department, Morriston Hospital, Swansea SA6 6NL, UK
1 shared publication- Daniel W. Lewis
Trauma and Orthopaedics, Royal Glamorgan Hospital, Llantrisant, GBR
1 shared publication - David Miller
Southmead Hospital, Westbury-on-Trym, Bristol, BS10 5NB, UK
1 shared publication - David Pemberton
Trauma and Orthopaedics, Royal Glamorgan Hospital, Llantrisant, GBR
1 shared publication - Ian G. Winson
Department of Trauma and Orthopedics, Southmead Hospital, Bristol, BS10 5NB, United Kingdom
1 shared publication - Joshua K. Nadimi
Trauma and Orthopaedics, University Hospital of Wales, Cardiff, GBR
1 shared publication
Latest Publications
- Open Access
- 7 March 2022
- Published by Springer Nature in Cureus
- Vol. 14 (3) , e22908
Patella-Femoral Joint Revision Surgery Following a Rare and Interesting Case of Implant Failure: A Case Report and Retrospective Analysis of Our Hospitals Implant Data
According to the national joint registry, patello-femoral joint (PFJ) replacement accounts for 1% of all knee arthroplasty procedures in the UK, 1014 of which were performed in 2018. The femoro-patella vialla (FPV) implant by MicroPort orthopaedics has a high reported rate of revision, more than four times that of other knee replacements. The mechanisms of failure are usually loss of fixation at the bone-implant interface. We observe a rare and unusual case form of patella component failure whereby the facets of the implant remain imbedded within the patella as a result of shear force, leaving a loose patella button within the knee. A literature review was conducted of reported modes of failure of the FPV implant and retrospective analysis of our units’ results looking into rate of revision, modes of failure, and assessment of a single surgeon’s patient outcome measure (Knee Society Scores). Retrospective analysis of our hospital's data revealed that 11% of FPV implants were revised in our unit, a large percentage of which were due to pain and progressive osteoarthritis. We observed revision rates of 5.84% at 3 years, 10.21% at 5 years, and 13.13% at 10 years, which is favourable to national joint registry revision estimates of 6.99%, 10.13%, and 19.10%, respectively. Knee Society Scores reveal a mean improvement of 39.65 (−38 to 100) at follow-up following FPV unicompartmental knee arthroplasty surgery. Our unit demonstrated better results from patient outcome measures when compared to literature and a lower rate of revision when compared to national figures.
- 7 March 2022
- Published by Springer Nature in Cureus
- Vol. 14 (3) , e22908
Open AccessPatella-Femoral Joint Revision Surgery Following a Rare and Interesting Case of Implant Failure: A Case Report and Retrospective Analysis of Our Hospitals Implant Data
According to the national joint registry, patello-femoral joint (PFJ) replacement accounts for 1% of all knee arthroplasty procedures in the UK, 1014 of which were performed in 2018. The femoro-patella vialla (FPV) implant by MicroPort orthopaedics has a high reported rate of revision, more than four times that of other knee replacements. The mechanisms of failure are usually loss of fixation at the bone-implant interface. We observe a rare and unusual case form of patella component failure whereby the facets of the implant remain imbedded within the patella as a result of shear force, leaving a loose patella button within the knee. A literature review was conducted of reported modes of failure of the FPV implant and retrospective analysis of our units’ results looking into rate of revision, modes of failure, and assessment of a single surgeon’s patient outcome measure (Knee Society Scores). Retrospective analysis of our hospital's data revealed that 11% of FPV implants were revised in our unit, a large percentage of which were due to pain and progressive osteoarthritis. We observed revision rates of 5.84% at 3 years, 10.21% at 5 years, and 13.13% at 10 years, which is favourable to national joint registry revision estimates of 6.99%, 10.13%, and 19.10%, respectively. Knee Society Scores reveal a mean improvement of 39.65 (−38 to 100) at follow-up following FPV unicompartmental knee arthroplasty surgery. Our unit demonstrated better results from patient outcome measures when compared to literature and a lower rate of revision when compared to national figures.
- 1 August 2020
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 26 (6) , 597-600
Foot injuries, playing surface and shoe design: Should we be thinking more about injury prevention
- 1 August 2020
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 26 (6) , 597-600
Foot injuries, playing surface and shoe design: Should we be thinking more about injury prevention