In vivo measurement of the elastic modulus of the human periodontal ligament
The present study was designated to determine the elastic properties of the periodontal ligament (PDL) in human subjects. A maxillary central incisor was experimentally translated so that stress or strain could be uniformly distributed in the PDL by applying a single force passing through the center of resistance. Displacements were measured under different magnitudes of load using a magnet-magnetic sensing system. From the load-displacement relations, Young's modulus of the PDL was calculated. The values determined were approximately 0.12 MPa under load ranging from 0 to 0.5 N, 0.25 MPa within the range of 0.5-1.0 N, 0.44 MPa under load 1.0-1.5 N, and between 0.69 and 0.96 MPa with 1.5-2.0 N. The values of Young's moduli increased almost exponentially with the increment of load due to a non-linear elasticity of the PDL.
- 1 October 2001
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 23 (8) , 567-572
In vivo measurement of the elastic modulus of the human periodontal ligament
The present study was designated to determine the elastic properties of the periodontal ligament (PDL) in human subjects. A maxillary central incisor was experimentally translated so that stress or strain could be uniformly distributed in the PDL by applying a single force passing through the center of resistance. Displacements were measured under different magnitudes of load using a magnet-magnetic sensing system. From the load-displacement relations, Young's modulus of the PDL was calculated. The values determined were approximately 0.12 MPa under load ranging from 0 to 0.5 N, 0.25 MPa within the range of 0.5-1.0 N, 0.44 MPa under load 1.0-1.5 N, and between 0.69 and 0.96 MPa with 1.5-2.0 N. The values of Young's moduli increased almost exponentially with the increment of load due to a non-linear elasticity of the PDL.
- 1 August 2001
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 120 (2) , 190-197
Experimental evaluation of initial tooth displacement, center of resistance, and center of rotation under the influence of an orthodontic force
- 1 August 2001
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 120 (2) , 190-197
Experimental evaluation of initial tooth displacement, center of resistance, and center of rotation under the influence of an orthodontic force
- 1 March 2001
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 48 (3) , 354-360
Development of a magnetic sensing device for tooth displacement under orthodontic forces
The authors are developed a system for measuring tooth displacement from orthodontic force. Eight small magnetic sensors and a magnet are combined to measure three-dimensional displacement. Sensors, arranged cubically in the three planes of space, are placed in the mouth and fixed to the posterior teeth by a splint. A magnet is placed in the center of the 8 sensors and attached to a front tooth that is subjected to orthodontic force. Sensors detect the magnet's movement as target tooth displacement. The system was designed to achieve displacement resolution of 1 /spl mu/m. The mean percentage of measurement errors was determined to be less than 1% in a 600-cubic-/spl mu/m volume from calibration. The system was tested clinically on human teeth. Although the oral environment, with high temperature and humidity, was not agreeable with the sensors, this system was stable and accurate enough for quantitative measurement of tooth displacement. The advantage of this system is the ability to detect tooth trajectories by decomposing displacement into translation and rotation and to determine the position of the center of rotation from these parameters.
- 1 March 2001
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 48 (3) , 354-360
Development of a magnetic sensing device for tooth displacement under orthodontic forces
The authors are developed a system for measuring tooth displacement from orthodontic force. Eight small magnetic sensors and a magnet are combined to measure three-dimensional displacement. Sensors, arranged cubically in the three planes of space, are placed in the mouth and fixed to the posterior teeth by a splint. A magnet is placed in the center of the 8 sensors and attached to a front tooth that is subjected to orthodontic force. Sensors detect the magnet's movement as target tooth displacement. The system was designed to achieve displacement resolution of 1 /spl mu/m. The mean percentage of measurement errors was determined to be less than 1% in a 600-cubic-/spl mu/m volume from calibration. The system was tested clinically on human teeth. Although the oral environment, with high temperature and humidity, was not agreeable with the sensors, this system was stable and accurate enough for quantitative measurement of tooth displacement. The advantage of this system is the ability to detect tooth trajectories by decomposing displacement into translation and rotation and to determine the position of the center of rotation from these parameters.