MCMatthew J. Comstock

Matthew J. Comstock

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Matthew J. Comstock has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Andrea A. Putnam

    Department of Biochemistry and Center for RNA Science and Therapeutics, Case Western University, Cleveland, USA

    2 shared publications
  • Cho-Ying Chuang

    Department of Physics and Astronomy , Michigan State University , East Lansing , Michigan 48824 , United States

    2 shared publications
  • Eckhard Jankowsky

    Department of Biochemistry and Center for RNA Science and Therapeutics, Case Western University, Cleveland, USA

    2 shared publications
  • Eric M. Patrick

    Department of Physics and Astronomy, Michigan State University, East Lansing, USA

    2 shared publications
  • Joseph D. Slivka

    Department of Physics and Astronomy, Michigan State University, East Lansing, USA

    2 shared publications
  • Kasun Senanayake

    Department of Physics and Astronomy, Michigan State University, East Lansing, USA

    2 shared publications

Latest Publications

  • Open Access

    High-resolution fleezers reveal duplex opening and stepwise assembly by an oligomer of the DEAD-box helicase Ded1p

    by Eric M. Patrick, Rajeev Yadav, Kasun Senanayake, Kyle Cotter, Andrea A. Putnam, Eckhard Jankowsky, Matthew J. Comstock

    DEAD-box RNA-dependent ATPases are ubiquitous in all domains of life where they bind and remodel RNA and RNA-protein complexes. DEAD-box ATPases with helicase activity unwind RNA duplexes by local opening of helical regions without directional movement through the duplexes and some of these enzymes, including Ded1p from Saccharomyces cerevisiae, oligomerize to effectively unwind RNA duplexes. Whether and how DEAD-box helicases coordinate oligomerization and unwinding is not known and it is unclear how many base pairs are actively opened. Using high-resolution optical tweezers and fluorescence, we reveal a highly dynamic and stochastic process of multiple Ded1p protomers assembling on and unwinding an RNA duplex. One Ded1p protomer binds to a duplex-adjacent ssRNA tail and promotes binding and subsequent unwinding of the duplex by additional Ded1p protomers in 4–6 bp steps. The data also reveal rapid duplex unwinding and rezipping linked with binding and dissociation of individual protomers and coordinated with the ATP hydrolysis cycle.


  • Open Access

    High-resolution fleezers reveal duplex opening and stepwise assembly by an oligomer of the DEAD-box helicase Ded1p

    by Eric M. Patrick, Rajeev Yadav, Kasun Senanayake, Kyle Cotter, Andrea A. Putnam, Eckhard Jankowsky, Matthew J. Comstock

    DEAD-box RNA helicases are ubiquitous in all domains of life where they bind and remodel RNA and RNA-protein complexes. DEAD-box helicases unwind RNA duplexes by local opening of helical regions without directional movement through the duplexes and some of these enzymes, including Ded1p from Saccharomyces cerevisiae, oligomerize to effectively unwind RNA duplexes. Whether and how DEAD-box helicases coordinate oligomerization and unwinding is not known and it is unclear how many base pairs are actively opened. Using high-resolution optical tweezers and fluorescence, we reveal a highly dynamic and stochastic process of multiple Ded1p protomers assembling on and unwinding an RNA duplex. One Ded1p protomer binds to a duplex-adjacent ssRNA tail and promotes binding and subsequent unwinding of the duplex by additional Ded1p protomers in 4-6 bp steps. The data also reveal rapid duplex unwinding and rezipping linked with binding and dissociation of individual protomers and coordinated with the ATP hydrolysis cycle.

  • Open Access

    An accurate probabilistic step finder for time-series analysis

    by Alex Rojewski, Maxwell Schweiger, Ioannis Sgouralis, Matthew Comstock, Steve Pressé

    Noisy time-series data is commonly collected from sources including Förster Resonance Energy Transfer experiments, patch clamp and force spectroscopy setups, among many others. Two of the most common paradigms for the detection of discrete transitions in such time-series data include: hidden Markov models (HMMs) and step-finding algorithms. HMMs, including their extensions to infinite state-spaces, inherently assume in analysis that holding times in discrete states visited are geometrically–or, loosely speaking in common language, exponentially–distributed. Thus the determination of step locations, especially in sparse and noisy data, is biased by HMMs toward identifying steps resulting in geometric holding times. In contrast, existing step-finding algorithms, while free of this restraint, often rely on ad hoc metrics to penalize steps recovered in time traces (by using various information criteria) and otherwise rely on approximate greedy algorithms to identify putative global optima. Here, instead, we devise a robust and general probabilistic (Bayesian) step-finding tool that neither relies on ad hoc metrics to penalize step numbers nor assumes geometric holding times in each state. As the number of steps themselves in a time-series are, a priori unknown, we treat these within a Bayesian nonparametric (BNP) paradigm. We find that the method developed, Bayesian Nonparametric Step (BNP-Step), accurately determines the number and location of transitions between discrete states without any assumed kinetic model and learns the emission distribution characteristic of each state. In doing so, we verify that BNP-Step can analyze sparser data sets containing higher noise and more closely-spaced states than otherwise resolved by current state-of-the-art methods. What is more, BNP-Step rigorously propagates measurement uncertainty into uncertainty over state transition locations, numbers, and emission levels as characterized by the posterior. We demonstrate the performance of BNP-Step on both synthetic data as well as data drawn from force spectroscopy experiments. SIGNIFICANCE: Many time-series data sets exist which are challenging to analyze with current state-of-the-art methods, either because they contain excessive noise or because they violate one or more assumptions inherent to the chosen analysis method. To our knowledge, BNP-Step is the first time-series analysis algorithm which leverages Bayesian nonparametrics to learn the number and location of transitions between states and the emission levels associated to each state, while providing rigorous estimates of uncertainty for the learned quantities. We anticipate our algorithm will allow analysis of data sets at levels of noise or sparsity beyond what current state-of-the-art methods allow, and could potentially reveal previously unknown features in data sets analyzed using existing methods.

  • Open Access

    Few-body hydrodynamic interactions probed by optical trap pulling experiment

    by Julian Lee, Kyle Cotter, Ibrahim Elsadek, Matthew J. Comstock, Steve Pressé

    We study the hydrodynamic coupling of neighboring micro-beads placed in a multiple optical trap setup allowing us to precisely control the degree of coupling and directly measure time-dependent trajectories of entrained beads. We performed measurements on configurations with increasing complexity starting with a pair of entrained beads moving in one dimension, then in two dimensions, and finally a triplet of beads moving in two dimensions. The average experimental trajectories of a probe bead compare well with the theoretical computation, illustrating the role of viscous coupling and setting timescales for probe bead relaxation. The findings also provide direct experimental corroborations of hydrodynamic coupling at large, micrometer spatial scales and long, millisecond timescales, of relevance to, e.g., microfluidic device design and hydrodynamic-assisted colloidal assembly, improving the capability of optical tweezers, and understanding the coupling between micrometer-scale objects within a living cell.


  • High-Resolution Optical Tweezers Combined with Multicolor Single-Molecule Microscopy

    by Rajeev Yadav, Kasun B. Senanayake, Matthew J. Comstock

    We present an instrument that combines high-resolution optical tweezers and multicolor confocal fluorescence spectroscopy. Biological macromolecules exhibit complex conformation and stoichiometry changes in coordination with their motion and activity. To further our understanding of the complex machinery of life, we need methods that can simultaneously probe more than one degree of freedom of single molecules and complexes. Fluorescence optical tweezers, or “fleezers,” combine the capabilities of optical tweezers and single-molecule fluorescence microscopy into a single instrument. Here we present the latest generation of a high-resolution fleezers instrument integrated with multicolor fluorescence spectroscopy. The tweezers portion of the instrument can manipulate biological macromolecules with pN scale forces while measuring subnanometer distances. Simultaneous with tweezers measurements, the multicolor fluorescence capability allows the direct observation of multiple molecules or multiple degrees of freedom which allows, for example, the observation of multiple proteins simultaneously within a complex. The instrument incorporates three fluorescence excitation lasers, all sourced from a single-mode optical fiber allowing a reliable alignment scheme, that allows, for example, three independent fluorescent probes or fluorescence resonance energy transfer (FRET) measurements and also increases flexibility in the choice of fluorescent probes. To avoid photobleaching and improve tweezers stability, the instrument implements a timesharing (using a single trap laser to produce a pair of traps via rapid switching between two locations) and interlacing (turning the trapping beam off when the fluorescence excitation beams are on and vice versa) scheme using acousto-optic modulators (AOM) to rapidly and precisely modulate lasers. Our latest “random phase” trap AOM control method obliterates previous residual trap positioning and bead position measurement errors. Here we present the general design principles and detailed construction and testing protocols for the instrument. Key words Optical tweezers Optical trapping Single-molecule fluorescence Multicolor fluorescence Förster Resonance Energy Transfer (FRET) Confocal microscopy Fleezers Acousto-optic device Timesharing tweezers


  • Open Access

    Observation of processive telomerase catalysis using high-resolution optical tweezers

    by Eric M. Patrick, Joseph D. Slivka, Bramyn Payne, Matthew J. Comstock, Jens C. Schmidt

    Telomere maintenance by telomerase is essential for continuous proliferation of human cells and is vital for the survival of stem cells and 90% of cancer cells. To compensate for telomeric DNA lost during DNA replication, telomerase processively adds GGTTAG repeats to chromosome ends by copying the template region within its RNA subunit. Between repeat additions, the RNA template must be recycled. How telomerase remains associated with substrate DNA during this critical translocation step remains unknown. Using a single-molecule telomerase activity assay utilizing high-resolution optical tweezers, we demonstrate that stable substrate DNA binding at an anchor site within telomerase facilitates the processive synthesis of telomeric repeats. The product DNA synthesized by telomerase can be recaptured by the anchor site or fold into G-quadruplex structures. Our results provide detailed mechanistic insights into telomerase catalysis, a process of critical importance in aging and cancer.


  • Combined High-Resolution Optical Tweezers and Multicolor Single-Molecule Fluorescence with an Automated Single-Molecule Assembly Line

    by Cho-Ying Chuang, Matthew Zammit, Miles L. Whitmore, Matthew J. Comstock

    We present an instrument that combines high-resolution optical tweezers and multi-color confocal fluorescence spectroscopy along with automated single molecule assembly. Multi-color allows the simultaneous observation of multiple molecules or multiple degrees of freedom which allows e.g., the observation of multiple proteins simultaneously within a complex. The instrument incorporates three fluorescence excitation lasers, with a reliable alignment scheme, that will allow three independent fluorescent probe or fluorescence resonance energy transfer (FRET) measurements and also increases flexibility in the choice of fluorescent molecules. We demonstrate the ability to simultaneously measure angstrom-scale changes in tether extension and fluorescence signals. Simultaneous tweezers and fluorescence measurement are particularly challenging due to fluorophore photobleaching, even more so if multiple fluorophores are to be measured. Therefore, 1) fluorescence excitation and detection is interlaced with time-shared dual optical traps. 2) We investigated the photostability of common fluorophores. The mean number of photons emitted before bleaching was unaffected by the trap laser and decreased only slightly with increasing excitation laser intensity. Surprisingly, we found that Cy5 outperforms other commonly used fluorophores by more than 5-fold. 3) We devised computer-controlled automation, which conserves fluorophore lifetime by quickly detecting fluorophore-labeled molecule binding, turning off lasers, and moving to add the next fluorophore-labeled component. The single-molecule assembly line enables the precise assembly of multi-molecule complexes while preserving fluorophores.


  • Combined Force Ramp and Equilibrium High-Resolution Investigations Reveal Multipath Heterogeneous Unfolding of Protein G

    by Dena Izadi, Yujie Chen, Miles L. Whitmore, Joseph D. Slivka, Kevin Ching, Lisa J. Lapidus, Matthew J. Comstock

    Over the past two decades, one of the standard models of protein folding has been the “two-state” model, in which a protein only resides in the folded or fully unfolded states with a single pathway between them. Recent advances in spatial and temporal resolution of biophysical measurements have revealed “beyond-two-state” complexity in protein folding, even for small, single-domain proteins. In this work, we used high-resolution optical tweezers to investigate the folding/unfolding kinetics of the B1 domain of immunoglobulin-binding protein G (GB1), a well-studied model system. Experiments were performed for GB1 both in and out of equilibrium using force spectroscopy. When the force was gradually ramped, simple single-peak folding force distributions were observed, while multiple rupture peaks were seen in the unfolding force distributions, consistent with multiple force-dependent parallel unfolding pathways. Force-dependent folding and unfolding rate constants were directly determined by both force-jump and fixed-trap measurements. Monte Carlo modeling using these rate constants was in good agreement with the force ramp data. The unfolding rate constants exhibited two different behaviors at low vs high force. At high force, the unfolding rate constant increased with increasing force, as previously reported by high force, high pulling speed force ramp measurements. However, at low force, the situation reversed and the unfolding rate constant decreased with increasing force. Taken together, these data indicate that this small protein has multiple distinct pathways to the native state on the free energy landscape.


  • Open Access

    Randomizing phase to remove acousto-optic device wiggle errors for high-resolution optical tweezers

    by Andrew G. Baker, Cho-Ying Chuang, Miles Whitmore, Matthew J. Comstock

    Acousto-optic (AO) devices have been used extensively in optical tweezers because of their flexibility and speed; however, these devices have trap positioning inaccuracies that limit their usefulness, especially for high-resolution applications. We show that these inaccuracies are due to interference patterns within the AO device sound fields. We have devised a method that removes these inaccuracies by reducing the coherence of the sound fields by directly controlling and randomizing the phase of the radio frequency voltage input signal. We demonstrate that the trapping inaccuracies are eliminated, for both constant trap position and force-ramp measurements, and that no additional noise is added. We show that this random phase method is applicable to both acousto-optic modulator and deflector type devices and can be easily integrated via software upgrade into existing instruments.