HFHerman J. Friedericy

Herman J. Friedericy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Herman J. Friedericy has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Decision-making Factors in Surgical Techniques and Attitudes Towards Environmental Sustainability

    by Kim E. van Nieuwenhuizen, Herman J. Friedericy, Anne C. PhD van der Eijk, Frank Willem Jansen, M. PhD Elske van den Akker-Van Marle

    Objective: Our study examines factors influencing surgical specialists’ choice of surgical technique and assesses the significance of the carbon footprint in this decision-making process. It also investigates their attitudes, behaviors, and barriers to environmental sustainability. Background: Climate change significantly threatens health, with surgery being a major contributor to health care’s carbon footprint. Methods: A cross-sectional study was conducted using a discrete choice experiment (DCE) and a questionnaire. Respondents were Dutch-speaking surgeons, gynecologists, and urologists with experience in minimally invasive surgery. They judged 14 choice sets, each presenting 2 hypothetical surgical scenarios that varied in postoperative length of stay, patient’s preference, specialists’ experience, costs, national guideline recommendations, and carbon footprint. The questionnaire explored attitudes, behaviors, and barriers to environmental sustainability. Results: Among the 116 respondents, patient’s preference emerged as the most important factor in the choice of a surgical technique [relative importance (RI) 27.35 (95% CI: 19.57–35.12], followed by postoperative length of stay [RI 21.41 (95% CI: 14.07–28.75)], specialists’ experience [RI 16.07 (95% CI: 11.45–20.69)], costs [RI 13.98 (95% CI: 8.42–19.55)], national guideline recommendations [RI 13.29 (95% CI: 8.41–18.16)] and carbon footprint [RI 7.90 (95% CI: 3.63–12.18)]. Respondents expressed concern about climate change (105/116; 90%), with 85% (98/116) altering personal behaviors, and 49% (57/116) changing work practices. They feel surgical specialists have a responsibility to be aware of surgery’s environmental impact (97/116; 84%), and a part has the knowledge to decrease this impact (39/116; 34%). The main barriers are time (73/116; 63%), costs (74/116; 64%), and inadequate training and information (67/116; 58%). Conclusions: Patient preference and postoperative length of stay are prioritized in surgical decision-making, while carbon footprint is the least significant factor. To enhance sustainability in surgical practice, barriers must be addressed, and sustainable techniques and devices should be developed and standardized, ensuring sustainability is inherent in the available options, rather than just relying on individual choice.


  • Open Access

    Greenhouse gas emissions due to inhalation anaesthetics in the Netherlands, usage data and a survey of preferences among Dutch anaesthesiologists

    by Herman J. Friedericy, Pascale A.H.T. Venema, Jessica F. Lockyer, Dinemarie M. Kweekel, Anne C. van der Eijk, Frank Willem Jansen, Elise Y. Sarton

    BACKGROUND: Anaesthetic gases are an important source of greenhouse gas emissions from operating theatres and can attribute significantly to the carbon footprint of a nation's healthcare system. OBJECTIVE: To estimate the magnitude of the climate impact of inhaled anaesthetics in the Netherlands. Furthermore, the goal was to assess the preferences of Dutch anaesthesiologists for anaesthesia techniques, and to explore opportunities for reducing greenhouse gas emissions due to anaesthesia practice. DESIGN: A 2019 bottom-up purchase analysis of inhalation anaesthetics used in all of the Dutch hospitals was executed and an online survey was conducted among Dutch anaesthesiologists regarding their preferences for anaesthetic agents. RESULTS: Purchasing quantities of volatile anaesthetic agents were obtained from 61 of the 69 hospital organisations in the Netherlands (response rate 88.4%). A total of 12.2 kilotons CO2 equivalent (0.07% of the Dutch healthcare system) was emitted due to inhalation anaesthetics in the Netherlands in 2019. The volume of the in 2019 purchased inhalation volatile anaesthetics was 9.178 l of sevoflurane (93.4%), 404 l of desflurane (4.1%) and 245 l of isoflurane (2.5%). The survey in which 182 anaesthesiologists participated demonstrated that propofol was the first drug of choice of 70% of respondents, desflurane was available in 16% of Dutch hospitals and 83% of anaesthesiologists answered never using desflurane. Nitrous oxide was not used by 63% of respondents, the remaining 27% reported using nitrous oxide only in less than 5% of their cases. CONCLUSION: The relatively low emission of greenhouse gases due to inhalation anaesthetics in Dutch healthcare compared to other countries can be explained by the limited use of nitrous oxide and desflurane by Dutch anaesthesiologists and their strong preference for intravenously administered propofol as an anaesthetic.


  • Open Access

    Optimising Surgical Instrument Trays for Sustainability and Patient Safety by Combining Actual Instrument Usage and Expert Recommendations

    by Kim E. van Nieuwenhuizen, Teun van Trier, Herman J. Friedericy, Frank Willem Jansen, Jenny Dankelman, Anne C. van der Eijk

    Annually, over 300 million surgeries occur globally, requiring numerous surgical instruments. However, many instruments on the tray are returned to the central sterile supply department (CSSD) unused, creating an unsustainable pattern of unnecessary consumption. To address this, we developed a method for optimising surgical instrument trays (SITs) that is straightforward to implement in other hospitals. This optimisation aims to enhance patient safety and sustainability and to improve working conditions and reduce costs. We identified actual instrument usage (IU) in the operating room (OR) and obtained expert recommendations (ERs). Data from both methods were combined in a computer model (CM) to adjust the SITs. The performance of the adjusted SITs was assessed over a year. IU of three different SITs was collected during 16 procedures (mean = 28.4%, SD = 6.4%). Combining IU and ERs resulted in a 36.7% reduction in instruments and a 31.3% weight reduction. These measures contribute to reducing the carbon footprint and enhancing sustainability. During the evaluation of the new SIT contents (n = 7 procedures), mean IU increased from 28.4% (SD = 6.4%) to 46.5% (SD = 11.0%), with no missing instruments during surgery. A one-year follow-up showed no need for further alterations. Combining both methods yields better results than using them individually, efficiently reducing unnecessary items in SITs without compromising patient safety.


  • Open Access

    Effect of unidirectional airflow ventilation on surgical site infection in cardiac surgery: environmental impact as a factor in the choice for turbulent mixed air flow

    by H.J. Friedericy, A.F. Friedericy, A. de Weger, E.L.A. van Dorp, R.A.A.L. Traversari, A.C. van der Eijk, F.W. Jansen


  • Open Access

    A New Method to Improve the Environmental Sustainability of the Operating Room: Healthcare Sustainability Mode and Effect Analysis (HSMEA)

    by Else F. de Ridder, Herman J. Friedericy, Anne C. van der Eijk, Jenny Dankelman, Frank Willem Jansen

    The purpose of this study was to describe a new method to effectively improve the environmental impact of operating rooms through a systematic approach. A proven successful prospective risk analysis tool to improve the safety of complex healthcare processes (Healthcare Failure Mode and Effect Analysis) was adapted to reduce the environmental impact of surgical waste. For this novel method, named the Healthcare Sustainability Mode and Effect Analysis (HSMEA), a multidisciplinary team, using a structured step-by-step approach, systematically inventories surgical waste, quantifies its environmental impacts, identifies hotspots, and provides solutions for improvement. The five steps of the HSMEA are described (definition of the topic, team assembly, flowchart creation, hazard analysis, actions and outcome measures) and the surgical procedure of a caesarean section was used as a case study to assess the applicability of this method to improve its environmental impact. Applying the HSMEA to caesarean sections resulted in a 22% volume reduction and a 22% carbon footprint reduction in surgical waste. This was achieved by revising the disposable custom pack in order to reduce the overage that was present, and by intensifying waste stream segregation for plastic and paper recycling. The HSMEA is a practical work floor tool to aid in the reduction of the environmental impact of surgical waste that is applicable to all types of operations. It is reproducible, and because it identifies carbon hotspots, it enables an efficient approach to the issue of operating room pollution.


  • Open Access

    Reducing the Environmental Impact of Sterilization Packaging for Surgical Instruments in the Operating Room: A Comparative Life Cycle Assessment of Disposable versus Reusable Systems

    by Herman J. Friedericy, Cas W. van Egmond, Joost G. Vogtländer, Anne C. van der Eijk, Frank Willem Jansen

    The widespread use of single-use polypropylene packaging for sterilization of surgical instruments (blue wrap) results in enormous environmental pollution and plastic waste, estimated at 115 million kilograms on a yearly basis in the United States alone. Rigid sterilization containers (RSCs) are a well-known alternative in terms of quality and price. This paper deals with two research questions investigating the following aspects: (A) the environmental advantage of RCS for high volumes (5000 use cycles) in big hospitals, and (B) the environmental break-even point of use-cycles for small hospitals. An in-depth life cycle assessment was used to benchmark the two systems. As such a benchmark is influenced by the indicator system, three indicator systems were applied: (a) carbon footprint, (b) ReCiPe, and (c) eco-costs. The results are as follows: (1) the analyzed RSC has 85% less environmental impact in carbon footprint, 52% in ReCiPe, and 84.5% in eco-costs; and (2) an ecological advantage already occurs after 98, 228, and 67 out of 5000 use cycles, respectively. Given these two alternative packaging systems with comparable costs and quality, our results show that there are potentially large environmental gains to be made when RSC is preferred to blue wrap as a packaging system for sterile surgical instruments on a global scale.


    • 14 October 2019
      • Vol. 163

    [Steps for reducing the carbon footprint of the operating room].

    by H J Friedericy, N H Sperna Weiland, Anne C Van Der Eijk, Frank Willem Jansen

    The healthcare sector contributes significantly to global warming due to carbon emissions; this sector is, therefore, partially responsible for the negative effects of climate change on public health. Carbon emissions by the healthcare sector amount to 7% of the total carbon footprint of the Netherlands. It is anticipated that measures to reduce carbon emissions in the operating room (OR) can make an important contribution to reducing carbonemissions in the hospital as a whole. The most important elements contributing to the carbon footprint of the OR are: energy consumption for heating, ventilation and air conditioning (HVAC); the emission of inhalation anaesthetics; the purchase of materials and equipment; and waste production. Direct carbon emissions by the OR can be reduced through the use of sustainable energy and setback of the HVAC outside office hours. Anaesthetists can dramatically reduce the carbon footprint of the OR by choosing for intravenous anaesthetics instead of inhalation anaesthetics. Indirect carbon emissions and waste production by the OR can be reduced through circular procurement, choosing reusable over disposable products and recycling.