Moataz Elsisy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Moataz Elsisy has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Youngjae Chun
Department of Industrial Engineering, University of Pittsburgh, Pittsburgh, PA, USA
7 shared publications Catherine Go
University of Pittsburgh Medical Center, Pittsburgh, PA, USA
4 shared publications- Chahinaz A. Saleh
Cairo University, Giza, Egypt
3 shared publications - Yasser H. Anis
Mechanical Design and Production Department, Faculty of Engineering, Cairo University, Giza, Egypt
3 shared publications Mustafa Arafa
American University in Cairo, New Cairo, Egypt
2 shared publications- Woon-Hong Yeo
George W. Woodruff School of Mechanical Engineering Georgia Institute of Technology Atlanta Georgia USA
2 shared publications
Latest Publications
- 18 February 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 211
Analytical model for stress calculation of ultra-thin cobalt chromium L605 coronary stent
- 18 February 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 211
Analytical model for stress calculation of ultra-thin cobalt chromium L605 coronary stent
- 5 September 2022
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 37 (8) , 1423-1435
In vitro and in vivo assessment of a novel ultra-flexible ventriculoamniotic shunt for treating fetal hydrocephalus
Fetal aqueductal stenosis (AS) is one of the most common causes of congenital hydrocephalus, which increases intracranial pressure due to partial or complete obstruction of cerebrospinal fluid (CSF) flow within the ventricular system. Approximately 2–4 infants per 10,000 births develop AS, which leads to progressive hydrocephalus, which enlarges the head often necessitating delivery by cesarean section. Most babies born with AS are severely neurologically impaired and experience a lifetime of disability. Therefore, a new device technology for venticuloamniotic shunting is urgently needed and has been studied to ameliorate or prevent fetal hydrocephalus development, which can provide a significant impact on patients and their family’s quality of life and on the decrease of the healthcare dollars spent for the treatment. This study has successfully validated the design of shunt devices and demonstrated the mechanical performance and valve functions. A functional prototype shunt has been fabricated and subsequently used in multiple in vitro tests to demonstrate the performance of this newly developed ventriculoamniotic shunt. The shunt contains a main silicone-nitinol composite tube, a superelastic 90° angled dual dumbbell anchor, and an ePTFE valve encased by a stainless-steel cage. The anchor will change its diameter from 1.15 mm (collapsed state) to 2.75 mm (deployed state) showing up to 1.4-fold diameter change in human body temperature. Flow rates in shunts were quantified to demonstrate the valve function in low flow rates mimicking the fetal hydrocephalus condition showing “no backflow” for the valved shunt while there is up to 15 mL/h flow through the shunt with pressure difference of 20 Pa. In vivo ovine study results show the initial successful device delivery and flow drainage with sheep model.
- 5 September 2022
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 37 (8) , 1423-1435
In vitro and in vivo assessment of a novel ultra-flexible ventriculoamniotic shunt for treating fetal hydrocephalus
Fetal aqueductal stenosis (AS) is one of the most common causes of congenital hydrocephalus, which increases intracranial pressure due to partial or complete obstruction of cerebrospinal fluid (CSF) flow within the ventricular system. Approximately 2–4 infants per 10,000 births develop AS, which leads to progressive hydrocephalus, which enlarges the head often necessitating delivery by cesarean section. Most babies born with AS are severely neurologically impaired and experience a lifetime of disability. Therefore, a new device technology for venticuloamniotic shunting is urgently needed and has been studied to ameliorate or prevent fetal hydrocephalus development, which can provide a significant impact on patients and their family’s quality of life and on the decrease of the healthcare dollars spent for the treatment. This study has successfully validated the design of shunt devices and demonstrated the mechanical performance and valve functions. A functional prototype shunt has been fabricated and subsequently used in multiple in vitro tests to demonstrate the performance of this newly developed ventriculoamniotic shunt. The shunt contains a main silicone-nitinol composite tube, a superelastic 90° angled dual dumbbell anchor, and an ePTFE valve encased by a stainless-steel cage. The anchor will change its diameter from 1.15 mm (collapsed state) to 2.75 mm (deployed state) showing up to 1.4-fold diameter change in human body temperature. Flow rates in shunts were quantified to demonstrate the valve function in low flow rates mimicking the fetal hydrocephalus condition showing “no backflow” for the valved shunt while there is up to 15 mL/h flow through the shunt with pressure difference of 20 Pa. In vivo ovine study results show the initial successful device delivery and flow drainage with sheep model.
- 25 April 2022
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 37 (3) , 389-401
In vitro and In vivo assessment of a novel organ perfusion stent for successful flow separation in donation after cardiac death
Shortage of healthy donors’ organs has appeared as one of the main challenges for organ transplantation. This study focuses on the novel endovascular device development to increase the number of available organs from cardiac death donors. The primary objective of this study is the design validation of a newly developed stent graft for the abdominal organ perfusion with cardiac blood flow isolation. In this paper, the effectiveness of the device design has been validated via the assessment of the device performance both in vitro and in vivo. The radial force of stent structure was first numerically analyzed using finite element method, then was quantified experimentally. The blood perfusion parameters were investigated to demonstrate their effect on the blood delivered to the abdominal organs, maintaining the organs healthy for donation. In vitro flow leakage was measured using a 3-D printing-based silicone aortic model to evaluate the isolation between cardiac flow and perfusion flow with minimum values. Following the design validation process, a functional prototype stent graft has been successfully fabricated using optimized laser welding conditions and subsequent joining processes. In vivo porcine study results have demonstrated smooth delivery and successful placement of the device showing complete cardiac flow separation isolating abdominal regions only with the oxygenated blood flow.
- 25 April 2022
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 37 (3) , 389-401
In vitro and In vivo assessment of a novel organ perfusion stent for successful flow separation in donation after cardiac death
Shortage of healthy donors’ organs has appeared as one of the main challenges for organ transplantation. This study focuses on the novel endovascular device development to increase the number of available organs from cardiac death donors. The primary objective of this study is the design validation of a newly developed stent graft for the abdominal organ perfusion with cardiac blood flow isolation. In this paper, the effectiveness of the device design has been validated via the assessment of the device performance both in vitro and in vivo. The radial force of stent structure was first numerically analyzed using finite element method, then was quantified experimentally. The blood perfusion parameters were investigated to demonstrate their effect on the blood delivered to the abdominal organs, maintaining the organs healthy for donation. In vitro flow leakage was measured using a 3-D printing-based silicone aortic model to evaluate the isolation between cardiac flow and perfusion flow with minimum values. Following the design validation process, a functional prototype stent graft has been successfully fabricated using optimized laser welding conditions and subsequent joining processes. In vivo porcine study results have demonstrated smooth delivery and successful placement of the device showing complete cardiac flow separation isolating abdominal regions only with the oxygenated blood flow.
- 22 May 2021
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 36 (2) , 332-345
Assessment of mechanical and biocompatible performance of ultra-large nitinol endovascular devices fabricated via a low-energy laser joining process
Nitinol is an excellent candidate material for developing various self-expanding endovascular devices due to its unique properties such as superelasticity, biocompatibility and shape memory effect. A low-energy laser joining technique suggests a high potential to create various large diameter Nitinol endovascular devices that contain complex geometries. The primary purpose of the study is to investigate the effects of laser joining process parameters with regard to the mechanical and biocompatible performance of Nitinol stents. Both the chemical composition and the microstructure of the laser-welded joints were evaluated using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). In vitro study results on cytotoxicity demonstrated that the joining condition of 8 Hz frequency and 1 kW laser power showed the highest degree of endothelial cell viability after thermal annealing in 500°C for 30 min. Also, in vitro study results showed the highest oxygen content at 0.9 kW laser power, 8 Hz frequency, and 0.3 mm spot size after the thermal annealing. Mechanical performance test results showed that the optimal condition for the highest disconnecting force was found at 1 Hz frequency and 1 kW power with 0.6 mm spot size. Two new endovascular devices have been fabricated using the optimized laser joining parameters, which have demonstrated successful device delivery and retrieval, as well as acute biocompatibility.
- 22 May 2021
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 36 (2) , 332-345
Assessment of mechanical and biocompatible performance of ultra-large nitinol endovascular devices fabricated via a low-energy laser joining process
Nitinol is an excellent candidate material for developing various self-expanding endovascular devices due to its unique properties such as superelasticity, biocompatibility and shape memory effect. A low-energy laser joining technique suggests a high potential to create various large diameter Nitinol endovascular devices that contain complex geometries. The primary purpose of the study is to investigate the effects of laser joining process parameters with regard to the mechanical and biocompatible performance of Nitinol stents. Both the chemical composition and the microstructure of the laser-welded joints were evaluated using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). In vitro study results on cytotoxicity demonstrated that the joining condition of 8 Hz frequency and 1 kW laser power showed the highest degree of endothelial cell viability after thermal annealing in 500°C for 30 min. Also, in vitro study results showed the highest oxygen content at 0.9 kW laser power, 8 Hz frequency, and 0.3 mm spot size after the thermal annealing. Mechanical performance test results showed that the optimal condition for the highest disconnecting force was found at 1 Hz frequency and 1 kW power with 0.6 mm spot size. Two new endovascular devices have been fabricated using the optimized laser joining parameters, which have demonstrated successful device delivery and retrieval, as well as acute biocompatibility.
- 22 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 4
Development of a nanosensor-integrated stent for wireless, continuous monitoring of restenosis progression
SPIE Digital Library Proceedings
- 22 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 4
Development of a nanosensor-integrated stent for wireless, continuous monitoring of restenosis progression
SPIE Digital Library Proceedings
- Open Access
Modeling of a Symmetric Five-Bar Displacement Amplification Compliant Mechanism for Energy Harvesting
This paper presents an analytical model to determine a closed form mathematical representation for the output displacement of a displacement amplification compliant mechanism used for energy harvesting. A symmetric five-bar compliant mechanism with right-circular and corner-filleted flexure hinges was mathematically modeled and its displacement was determined using the Castigliano energy theorem. The stresses within the flexure joints, the weakest points in the mechanism body, were calculated. The mathematical model expresses both the displacement amplification and the stresses as functions of the design parameters and the load caused by the harvester. The developed model can be used to optimize the mechanism dimensions for maximum harvested power, while minimizing its structural stresses. The mechanism was also modeled numerically using finite element methods; both the analytical and numerical models were verified experimentally. The mathematical model of the mechanism was integrated with a model representing a piezoelectric energy harvester to calculate the open-circuit voltage. As a proof of concept, experiments were performed using an unimorph piezoelectric cantilever at low-frequency (less than 1 Hz) harmonic excitation inputs. The measured open-circuit voltage was found to be in agreement with that calculated using the proposed model, when integrated with the model representing the piezoelectric beam. The power generated by the piezoelectric harvester, equipped with the proposed displacement amplification mechanism, was more than a hundred times that without amplification.
Open AccessModeling of a Symmetric Five-Bar Displacement Amplification Compliant Mechanism for Energy Harvesting
This paper presents an analytical model to determine a closed form mathematical representation for the output displacement of a displacement amplification compliant mechanism used for energy harvesting. A symmetric five-bar compliant mechanism with right-circular and corner-filleted flexure hinges was mathematically modeled and its displacement was determined using the Castigliano energy theorem. The stresses within the flexure joints, the weakest points in the mechanism body, were calculated. The mathematical model expresses both the displacement amplification and the stresses as functions of the design parameters and the load caused by the harvester. The developed model can be used to optimize the mechanism dimensions for maximum harvested power, while minimizing its structural stresses. The mechanism was also modeled numerically using finite element methods; both the analytical and numerical models were verified experimentally. The mathematical model of the mechanism was integrated with a model representing a piezoelectric energy harvester to calculate the open-circuit voltage. As a proof of concept, experiments were performed using an unimorph piezoelectric cantilever at low-frequency (less than 1 Hz) harmonic excitation inputs. The measured open-circuit voltage was found to be in agreement with that calculated using the proposed model, when integrated with the model representing the piezoelectric beam. The power generated by the piezoelectric harvester, equipped with the proposed displacement amplification mechanism, was more than a hundred times that without amplification.
- Open Access
- 3 February 2021
- Published by ASME International in Journal of Engineering Materials and Technology
- Vol. 143 (3)
Current-Dependent Dynamics of Bidirectional Self-Folding for Multi-Layer Polymers Using Local Resistive Heating
The purpose of this paper is to characterize the dynamics and direction of self-folding of pre-strained polystyrene (PSPS) and non-pre-strained styrene (NPS), which results from local shrinkage using a new process of directed self-folding of polymer sheets based on a resistively heated ribbon that is in contact with the sheets. A temperature gradient across the thickness of this shape memory polymer (SMP) sheet induces folding along the line of contact with the heating ribbon. Varying the electric current changes the degree of folding and the extent of local material flow. This method can be used to create practical three-dimensional (3D) structures. Sheets of PSPS and NPS were cut to 10 × 20 mm samples, and their folding angles were plotted with respect to time, as obtained from in situ videography. In addition, the use of polyimide tape (Kapton) was investigated for controlling the direction of self-folding. Results show that folding happens on the opposite side of the sample with respect to the tape, regardless of which side the heating ribbon is on, or whether gravity is opposing the folding direction. The results are quantitatively explained using a viscoelastic finite element model capable of describing bidirectional folds arising from the interplay between viscoelastic relaxation and strain mismatch between polystyrene and polyimide. Given the tunability of fold times and the extent of local material flow, resistive-heat-assisted folding is a promising approach for manufacturing complex 3D lightweight structures by origami engineering.
- 3 February 2021
- Published by ASME International in Journal of Engineering Materials and Technology
- Vol. 143 (3)
Open AccessCurrent-Dependent Dynamics of Bidirectional Self-Folding for Multi-Layer Polymers Using Local Resistive Heating
The purpose of this paper is to characterize the dynamics and direction of self-folding of pre-strained polystyrene (PSPS) and non-pre-strained styrene (NPS), which results from local shrinkage using a new process of directed self-folding of polymer sheets based on a resistively heated ribbon that is in contact with the sheets. A temperature gradient across the thickness of this shape memory polymer (SMP) sheet induces folding along the line of contact with the heating ribbon. Varying the electric current changes the degree of folding and the extent of local material flow. This method can be used to create practical three-dimensional (3D) structures. Sheets of PSPS and NPS were cut to 10 × 20 mm samples, and their folding angles were plotted with respect to time, as obtained from in situ videography. In addition, the use of polyimide tape (Kapton) was investigated for controlling the direction of self-folding. Results show that folding happens on the opposite side of the sample with respect to the tape, regardless of which side the heating ribbon is on, or whether gravity is opposing the folding direction. The results are quantitatively explained using a viscoelastic finite element model capable of describing bidirectional folds arising from the interplay between viscoelastic relaxation and strain mismatch between polystyrene and polyimide. Given the tunability of fold times and the extent of local material flow, resistive-heat-assisted folding is a promising approach for manufacturing complex 3D lightweight structures by origami engineering.
- 14 January 2020
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 108 (5) , 2192-2203
Comprehensive assessment of mechanical behavior of an extremely long stent graft to control hemorrhage in torso
Traumatic vascular injuries, resulting from either civilian accidents or wounded soldiers, require new endovascular devices (i.e., stent graft) to rapidly control the excessive internal hemorrhage in torso region. Current stent designs are limited by their permanent nature, which is note well suited for emergent placement. A retrievable stent graft could regulate the internal bleeding temporarily, as fast as possible with the most feasible performance, until the patients arrive the hospital to receive the proper treatment. The novel endovascular device of this study is designed according to the anatomy of a porcine model with plans to transition to a human model in the future. The stent graft is manufactured using a substantially long nitinol backbone and covered selectively based on anatomic measurements, with highly stretchable expanded‐polytetrafluoroethylene (ePTFE). In this study, our group comprehensively explored designing and manufacturing methods, and their impact on the stent graft performance. Geometric parameters and heat treatment conditions were investigated to show their effect on the radial force of the metallic backbone. As a retrievable device, the resistance force for retrieval as well as deployment were measured, and analyzed to be manipulated through ePTFE covering configurations. In vitro measurements for bleeding were measured using swine aorta to show the functionality of the stent graft under the simulated pulsatile flow circulation. Finally, the stent graft showed substantial effectiveness for hemorrhage control in vivo, using swine model. The new design and fabrication methods enable rapid hemorrhage control that can be removed at the time of a dedicated surgical repair.
- 14 January 2020
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 108 (5) , 2192-2203
Comprehensive assessment of mechanical behavior of an extremely long stent graft to control hemorrhage in torso
Traumatic vascular injuries, resulting from either civilian accidents or wounded soldiers, require new endovascular devices (i.e., stent graft) to rapidly control the excessive internal hemorrhage in torso region. Current stent designs are limited by their permanent nature, which is note well suited for emergent placement. A retrievable stent graft could regulate the internal bleeding temporarily, as fast as possible with the most feasible performance, until the patients arrive the hospital to receive the proper treatment. The novel endovascular device of this study is designed according to the anatomy of a porcine model with plans to transition to a human model in the future. The stent graft is manufactured using a substantially long nitinol backbone and covered selectively based on anatomic measurements, with highly stretchable expanded‐polytetrafluoroethylene (ePTFE). In this study, our group comprehensively explored designing and manufacturing methods, and their impact on the stent graft performance. Geometric parameters and heat treatment conditions were investigated to show their effect on the radial force of the metallic backbone. As a retrievable device, the resistance force for retrieval as well as deployment were measured, and analyzed to be manipulated through ePTFE covering configurations. In vitro measurements for bleeding were measured using swine aorta to show the functionality of the stent graft under the simulated pulsatile flow circulation. Finally, the stent graft showed substantial effectiveness for hemorrhage control in vivo, using swine model. The new design and fabrication methods enable rapid hemorrhage control that can be removed at the time of a dedicated surgical repair.
- Open Access
Use of Superelastic Nitinol and Highly-Stretchable Latex to Develop a Tongue Prosthetic Assist Device and Facilitate Swallowing for Dysphagia Patients
We introduce a new tongue prosthetic assist device (TPAD), which shows the first prosthetic application for potential treatment of swallowing difficulty in dysphagia patients. The native tongue has a number of complex movements that are not feasible to mimic using a single mechanical prosthetic device. In order to overcome this challenge, our device has three key features, including (1) a superelastic nitinol structure that transfers the force produced by the jaws during chewing towards the palate, (2) angled composite tubes for guiding the nitinol strips smoothly during the motion, and (3) highly stretchable thin polymeric membrane as a covering sheet in order to secure the food and fluids on top of the TPAD for easy swallowing. A set of mechanical experiments has optimized the size and angle of the guiding tubes for the TPAD. The low-profile TPAD was successfully placed in a cadaver model and its mobility effectively provided a simplistic mimic of the native tongue elevation function by applying vertical chewing motions. This is the first demonstration of a new oral device powered by the jaw motions in order to create a bulge in the middle of the mouth mimicking native tongue behavior.
Open AccessUse of Superelastic Nitinol and Highly-Stretchable Latex to Develop a Tongue Prosthetic Assist Device and Facilitate Swallowing for Dysphagia Patients
We introduce a new tongue prosthetic assist device (TPAD), which shows the first prosthetic application for potential treatment of swallowing difficulty in dysphagia patients. The native tongue has a number of complex movements that are not feasible to mimic using a single mechanical prosthetic device. In order to overcome this challenge, our device has three key features, including (1) a superelastic nitinol structure that transfers the force produced by the jaws during chewing towards the palate, (2) angled composite tubes for guiding the nitinol strips smoothly during the motion, and (3) highly stretchable thin polymeric membrane as a covering sheet in order to secure the food and fluids on top of the TPAD for easy swallowing. A set of mechanical experiments has optimized the size and angle of the guiding tubes for the TPAD. The low-profile TPAD was successfully placed in a cadaver model and its mobility effectively provided a simplistic mimic of the native tongue elevation function by applying vertical chewing motions. This is the first demonstration of a new oral device powered by the jaw motions in order to create a bulge in the middle of the mouth mimicking native tongue behavior.