Moataz Elsisy

Moataz Elsisy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Moataz Elsisy has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analytical model for stress calculation of ultra-thin cobalt chromium L605 coronary stent

    by Amr F. Mohamed, Chahinaz A. Saleh, Youngjae Chun, Chang Hun Kum, Jae Hwa Cho, Gyuhyun Jin, Sang Hyun An, Moataz Elsisy


  • In vitro and in vivo assessment of a novel ultra-flexible ventriculoamniotic shunt for treating fetal hydrocephalus

    by Stephen P Emery, Stephanie Greene, Moataz Elsisy, Kaitlin Chung, Sang-Ho Ye, Seungil Kim, William R Wagner, Nika Hazen, Youngjae Chun

    Fetal aqueductal stenosis (AS) is one of the most common causes of congenital hydrocephalus, which increases intracranial pressure due to partial or complete obstruction of cerebrospinal fluid (CSF) flow within the ventricular system. Approximately 2–4 infants per 10,000 births develop AS, which leads to progressive hydrocephalus, which enlarges the head often necessitating delivery by cesarean section. Most babies born with AS are severely neurologically impaired and experience a lifetime of disability. Therefore, a new device technology for venticuloamniotic shunting is urgently needed and has been studied to ameliorate or prevent fetal hydrocephalus development, which can provide a significant impact on patients and their family’s quality of life and on the decrease of the healthcare dollars spent for the treatment. This study has successfully validated the design of shunt devices and demonstrated the mechanical performance and valve functions. A functional prototype shunt has been fabricated and subsequently used in multiple in vitro tests to demonstrate the performance of this newly developed ventriculoamniotic shunt. The shunt contains a main silicone-nitinol composite tube, a superelastic 90° angled dual dumbbell anchor, and an ePTFE valve encased by a stainless-steel cage. The anchor will change its diameter from 1.15 mm (collapsed state) to 2.75 mm (deployed state) showing up to 1.4-fold diameter change in human body temperature. Flow rates in shunts were quantified to demonstrate the valve function in low flow rates mimicking the fetal hydrocephalus condition showing “no backflow” for the valved shunt while there is up to 15 mL/h flow through the shunt with pressure difference of 20 Pa. In vivo ovine study results show the initial successful device delivery and flow drainage with sheep model.


  • In vitro and In vivo assessment of a novel organ perfusion stent for successful flow separation in donation after cardiac death

    by Moataz Elsisy, Bryan Tillman, Lynn Chau, Catherine Go, Sung Kwon Cho, Youngjae Chun

    Shortage of healthy donors’ organs has appeared as one of the main challenges for organ transplantation. This study focuses on the novel endovascular device development to increase the number of available organs from cardiac death donors. The primary objective of this study is the design validation of a newly developed stent graft for the abdominal organ perfusion with cardiac blood flow isolation. In this paper, the effectiveness of the device design has been validated via the assessment of the device performance both in vitro and in vivo. The radial force of stent structure was first numerically analyzed using finite element method, then was quantified experimentally. The blood perfusion parameters were investigated to demonstrate their effect on the blood delivered to the abdominal organs, maintaining the organs healthy for donation. In vitro flow leakage was measured using a 3-D printing-based silicone aortic model to evaluate the isolation between cardiac flow and perfusion flow with minimum values. Following the design validation process, a functional prototype stent graft has been successfully fabricated using optimized laser welding conditions and subsequent joining processes. In vivo porcine study results have demonstrated smooth delivery and successful placement of the device showing complete cardiac flow separation isolating abdominal regions only with the oxygenated blood flow.


  • A retrievable, dual-chamber stent protects against warm ischemia of donor organs in a model of donation after circulatory death

    by Catherine Go, Moataz Elsisy, Brian Frenz, J.B. Moses, Amit D. Tevar, Anthony J. Demetris, Youngjae Chun, Bryan W. Tillman


  • Assessment of mechanical and biocompatible performance of ultra-large nitinol endovascular devices fabricated via a low-energy laser joining process

    by Moataz Elsisy, Mahdis Shayan, Yanfei Chen, Bryan W Tillman, Catherine Go, Youngjae Chun

    Nitinol is an excellent candidate material for developing various self-expanding endovascular devices due to its unique properties such as superelasticity, biocompatibility and shape memory effect. A low-energy laser joining technique suggests a high potential to create various large diameter Nitinol endovascular devices that contain complex geometries. The primary purpose of the study is to investigate the effects of laser joining process parameters with regard to the mechanical and biocompatible performance of Nitinol stents. Both the chemical composition and the microstructure of the laser-welded joints were evaluated using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). In vitro study results on cytotoxicity demonstrated that the joining condition of 8 Hz frequency and 1 kW laser power showed the highest degree of endothelial cell viability after thermal annealing in 500°C for 30 min. Also, in vitro study results showed the highest oxygen content at 0.9 kW laser power, 8 Hz frequency, and 0.3 mm spot size after the thermal annealing. Mechanical performance test results showed that the optimal condition for the highest disconnecting force was found at 1 Hz frequency and 1 kW power with 0.6 mm spot size. Two new endovascular devices have been fabricated using the optimized laser joining parameters, which have demonstrated successful device delivery and retrieval, as well as acute biocompatibility.


  • Development of a nanosensor-integrated stent for wireless, continuous monitoring of restenosis progression

    by Moataz Elsisy, Robert Herbert, Woon-Hong Yeo, John J. Pacella, Youngjae Chun

    SPIE Digital Library Proceedings


  • Open Access

    Modeling of a Symmetric Five-Bar Displacement Amplification Compliant Mechanism for Energy Harvesting

    by Moataz M. Elsisy, Mustafa H. Arafa, Chahinaz A. Saleh, Yasser H. Anis

    This paper presents an analytical model to determine a closed form mathematical representation for the output displacement of a displacement amplification compliant mechanism used for energy harvesting. A symmetric five-bar compliant mechanism with right-circular and corner-filleted flexure hinges was mathematically modeled and its displacement was determined using the Castigliano energy theorem. The stresses within the flexure joints, the weakest points in the mechanism body, were calculated. The mathematical model expresses both the displacement amplification and the stresses as functions of the design parameters and the load caused by the harvester. The developed model can be used to optimize the mechanism dimensions for maximum harvested power, while minimizing its structural stresses. The mechanism was also modeled numerically using finite element methods; both the analytical and numerical models were verified experimentally. The mathematical model of the mechanism was integrated with a model representing a piezoelectric energy harvester to calculate the open-circuit voltage. As a proof of concept, experiments were performed using an unimorph piezoelectric cantilever at low-frequency (less than 1 Hz) harmonic excitation inputs. The measured open-circuit voltage was found to be in agreement with that calculated using the proposed model, when integrated with the model representing the piezoelectric beam. The power generated by the piezoelectric harvester, equipped with the proposed displacement amplification mechanism, was more than a hundred times that without amplification.


  • Open Access

    Current-Dependent Dynamics of Bidirectional Self-Folding for Multi-Layer Polymers Using Local Resistive Heating

    by Moataz Elsisy, Evan Poska, Moataz Abdulhafez, Mostafa Bedewy

    The purpose of this paper is to characterize the dynamics and direction of self-folding of pre-strained polystyrene (PSPS) and non-pre-strained styrene (NPS), which results from local shrinkage using a new process of directed self-folding of polymer sheets based on a resistively heated ribbon that is in contact with the sheets. A temperature gradient across the thickness of this shape memory polymer (SMP) sheet induces folding along the line of contact with the heating ribbon. Varying the electric current changes the degree of folding and the extent of local material flow. This method can be used to create practical three-dimensional (3D) structures. Sheets of PSPS and NPS were cut to 10 × 20 mm samples, and their folding angles were plotted with respect to time, as obtained from in situ videography. In addition, the use of polyimide tape (Kapton) was investigated for controlling the direction of self-folding. Results show that folding happens on the opposite side of the sample with respect to the tape, regardless of which side the heating ribbon is on, or whether gravity is opposing the folding direction. The results are quantitatively explained using a viscoelastic finite element model capable of describing bidirectional folds arising from the interplay between viscoelastic relaxation and strain mismatch between polystyrene and polyimide. Given the tunability of fold times and the extent of local material flow, resistive-heat-assisted folding is a promising approach for manufacturing complex 3D lightweight structures by origami engineering.


  • Comprehensive assessment of mechanical behavior of an extremely long stent graft to control hemorrhage in torso

    by Moataz Elsisy, Bryan W. Tillman, Catherine Go, Jenna Kuhn, Sung K. Cho, William W. Clark, Junkyu Park, Youngjae Chun

    Traumatic vascular injuries, resulting from either civilian accidents or wounded soldiers, require new endovascular devices (i.e., stent graft) to rapidly control the excessive internal hemorrhage in torso region. Current stent designs are limited by their permanent nature, which is note well suited for emergent placement. A retrievable stent graft could regulate the internal bleeding temporarily, as fast as possible with the most feasible performance, until the patients arrive the hospital to receive the proper treatment. The novel endovascular device of this study is designed according to the anatomy of a porcine model with plans to transition to a human model in the future. The stent graft is manufactured using a substantially long nitinol backbone and covered selectively based on anatomic measurements, with highly stretchable expanded‐polytetrafluoroethylene (ePTFE). In this study, our group comprehensively explored designing and manufacturing methods, and their impact on the stent graft performance. Geometric parameters and heat treatment conditions were investigated to show their effect on the radial force of the metallic backbone. As a retrievable device, the resistance force for retrieval as well as deployment were measured, and analyzed to be manipulated through ePTFE covering configurations. In vitro measurements for bleeding were measured using swine aorta to show the functionality of the stent graft under the simulated pulsatile flow circulation. Finally, the stent graft showed substantial effectiveness for hemorrhage control in vivo, using swine model. The new design and fabrication methods enable rapid hemorrhage control that can be removed at the time of a dedicated surgical repair.


  • Open Access

    Use of Superelastic Nitinol and Highly-Stretchable Latex to Develop a Tongue Prosthetic Assist Device and Facilitate Swallowing for Dysphagia Patients

    by Mahdis Shayan, Neil Gildener-Leapman, Moataz Elsisy, Jack T. Hastings, Shinjae Kwon, Woon-Hong Yeo, Jee-Hong Kim, Puneeth Shridhar, Gabrielle Salazar, Youngjae Chun

    We introduce a new tongue prosthetic assist device (TPAD), which shows the first prosthetic application for potential treatment of swallowing difficulty in dysphagia patients. The native tongue has a number of complex movements that are not feasible to mimic using a single mechanical prosthetic device. In order to overcome this challenge, our device has three key features, including (1) a superelastic nitinol structure that transfers the force produced by the jaws during chewing towards the palate, (2) angled composite tubes for guiding the nitinol strips smoothly during the motion, and (3) highly stretchable thin polymeric membrane as a covering sheet in order to secure the food and fluids on top of the TPAD for easy swallowing. A set of mechanical experiments has optimized the size and angle of the guiding tubes for the TPAD. The low-profile TPAD was successfully placed in a cadaver model and its mobility effectively provided a simplistic mimic of the native tongue elevation function by applying vertical chewing motions. This is the first demonstration of a new oral device powered by the jaw motions in order to create a bulge in the middle of the mouth mimicking native tongue behavior.