Julia Koch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Julia Koch has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Martin Schuettler
3 shared publications- Thomas Stieglitz
Laboratory for Biomedical Microtechnology, IMTEK, University of Freiburg
3 shared publications Bettina Geiger
Laboratory for MEMS Applications, IMTEK - Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
1 shared publication- Cristian Pasluosta
University of Freiburg
1 shared publication - Elena Kipf
Laboratory for MEMS Applications, IMTEK - Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
1 shared publication - Johannes Erben
Laboratory for MEMS Applications, IMTEK - Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
1 shared publication
Latest Publications
- Open Access
- 29 October 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (6) , 061002
Electrical connectors for neural implants: design, state of the art and future challenges of an underestimated component
Technological advances in electrically active implantable devices have increased the complexity of hardware design. In particular, the increasing number of stimulation and recording channels requires innovative approaches for connectors that interface electrodes with the implant circuitry. Objective. This work aims to provide a common theoretical ground for implantable connector development with a focus on neural applications. Approach. Aspects and experiences from several disciplines are compiled from an engineering perspective to discuss the state of the art of connector solutions. Whenever available, we also present general design guidelines. Main results. Degradation mechanisms, material stability and design rules in terms of biocompatibility and biostability are introduced. Considering contact physics, we address the design and characterization of the contact zone and review contaminants, wear and contact degradation. For high-channel counts and body-like environments, insulation can be even more crucial than the electrical connection itself. Therefore, we also introduce the requirements for electrical insulation to prevent signal loss and distortion and discuss its impact on the practical implementation. Significance. A final review is dedicated to the state of the art connector concepts, their mechanical setup, electrical performance and the interface to other implant components. We conclude with an outlook for possible approaches for the future generations of implants.
- 29 October 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (6) , 061002
Open AccessElectrical connectors for neural implants: design, state of the art and future challenges of an underestimated component
Technological advances in electrically active implantable devices have increased the complexity of hardware design. In particular, the increasing number of stimulation and recording channels requires innovative approaches for connectors that interface electrodes with the implant circuitry. Objective. This work aims to provide a common theoretical ground for implantable connector development with a focus on neural applications. Approach. Aspects and experiences from several disciplines are compiled from an engineering perspective to discuss the state of the art of connector solutions. Whenever available, we also present general design guidelines. Main results. Degradation mechanisms, material stability and design rules in terms of biocompatibility and biostability are introduced. Considering contact physics, we address the design and characterization of the contact zone and review contaminants, wear and contact degradation. For high-channel counts and body-like environments, insulation can be even more crucial than the electrical connection itself. Therefore, we also introduce the requirements for electrical insulation to prevent signal loss and distortion and discuss its impact on the practical implementation. Significance. A final review is dedicated to the state of the art connector concepts, their mechanical setup, electrical performance and the interface to other implant components. We conclude with an outlook for possible approaches for the future generations of implants.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2017 (1557170X) , 238-241
Design of contact zone topography for implantable high-channel electrical connectors
Detachable high-channel electrical connections pose a bottleneck on the path to active implants with higher numbers of electrode contacts and miniaturized geometries. Not only low-resistance, reproducible and reliable contacts have to be realized but also seals that ensure electrical insulation in the harsh body environment. Using planar contact arrangements one can resort to laser microprocessing leading to minimal size connectors. However, this poses the need to carefully design the topographies within the contact zone. In this study, we assess different methods to design the topography of planar contact pad arrays. Using topographical analysis and evaluation of electrical functionality, influential mechanisms were identified and two functional ones have been selected.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2017 (1557170X) , 238-241
Design of contact zone topography for implantable high-channel electrical connectors
Detachable high-channel electrical connections pose a bottleneck on the path to active implants with higher numbers of electrode contacts and miniaturized geometries. Not only low-resistance, reproducible and reliable contacts have to be realized but also seals that ensure electrical insulation in the harsh body environment. Using planar contact arrangements one can resort to laser microprocessing leading to minimal size connectors. However, this poses the need to carefully design the topographies within the contact zone. In this study, we assess different methods to design the topography of planar contact pad arrays. Using topographical analysis and evaluation of electrical functionality, influential mechanisms were identified and two functional ones have been selected.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 805-808
Development of a multichannel implantable connector
Further development of active implantable medical devices (AIMDs) coming along with higher channel counts and improved maintainability raises the requirements for implantable connectors in such systems. We developed a concept for an implantable multichannel connector. Contact pads manufactured by laser-structuring that are embedded into a silicone substrate serve as contact partners. Processing features specific to two laser technologies were exploited not only to cut the materials but also to 3D-shape the surfaces of the contact pads. First tests for the long-term behavior show stable contact and isolation properties during 6 weeks of soaking at elevated temperature.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 805-808
Development of a multichannel implantable connector
Further development of active implantable medical devices (AIMDs) coming along with higher channel counts and improved maintainability raises the requirements for implantable connectors in such systems. We developed a concept for an implantable multichannel connector. Contact pads manufactured by laser-structuring that are embedded into a silicone substrate serve as contact partners. Processing features specific to two laser technologies were exploited not only to cut the materials but also to 3D-shape the surfaces of the contact pads. First tests for the long-term behavior show stable contact and isolation properties during 6 weeks of soaking at elevated temperature.
- 1 October 2013
- Published by Elsevier in Bioresource Technology
- Vol. 146, 386-392
Systematic screening of carbon-based anode materials for microbial fuel cells with Shewanella oneidensis MR-1
- 1 October 2013
- Published by Elsevier in Bioresource Technology
- Vol. 146, 386-392
Systematic screening of carbon-based anode materials for microbial fuel cells with Shewanella oneidensis MR-1