QWQiu Wang

Qiu Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qiu Wang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • Huafeng Liu

    Huazhong University of Science and Technology

    3 shared publications
  • Liangcheng Tu

    National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics, Huazhong University of Science and Technology, Wuhan, China

    3 shared publications
  • Chun Zhao

    School of Physics, Engineering, and Technology, and York Biomedical Research Institute, University of York, York, U.K.

    2 shared publications
  • Qiangwei Xu

    MOE Key Laboratory of Fundamental Physical Quantities Measurement, Hubei Key Laboratory of Gravitation and Quantum Physics, PGMF and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, China

    2 shared publications
  • Shaolin Zhang

    MOE Key Laboratory of Fundamental Physical Quantities Measurement, Hubei Key Laboratory of Gravitation and Quantum Physics, PGMF and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, China

    2 shared publications
  • Shitao Yan

    MOE Key Laboratory of Fundamental Physical Quantities Measurement, Hubei Key Laboratory of Gravitation and Quantum Physics, PGMF and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, China

    2 shared publications

Latest Publications

  • Tilt-Induced Noise Improvement of a Nano-g MEMS Accelerometer for Lunar Seismograph With Omnidirectional Deployment

    by Hao Ouyang, Ruikun Li, Qiu Wang, Yue Liu, Libo Qiu, Shaobo Qu, Huafeng Liu

    China’s Lunar Exploration plans to deploy Lunar Seismograph on the moon’s surface to detect moon-quakes. Given the unknown inclination angle of the lunar landing, it is important that these sensors possess the capability to adapt to different slopes. This article introduces a MEMS accelerometer that is capable of automatic levelling with omnidirectional deployment. Unlike traditional high-precision accelerometers, which require manual or motorized levelling at a large tilt angle, this accelerometer achieves levelling without any mechanical levelling system. Within this paper, a precise theoretical noise model is established, and by measuring each noise source against their theoretical noise gains, a total theoretical noise floor is calculated. The theoretical noise floor aligns perfectly with the actual measured noise floor, validating the correctness of the model. The noise tests indicate a noise floor reaching 3 ng/sqrt(Hz) @1-30Hz, with low-frequency noise performance achieving 20 ng/sqrt(Hz) @0.01Hz. The dual-axis turntable tests demonstrate that the accelerometer can work at any angle. Furthermore, it clearly detected earthquake signals of M5.5 from distances over 2000 km, matching the signals detected by a co-located commercial seismometer with residual of 8.6 ng. This article provides new insights into the levelling system design of subsequent MEMS accelerometer or seismometer.


  • An Opto-mechanical MEMS Accelerometer with Noise Floor of 40 ng/Hz1/2

    by Shimin Jiao, Hao Ouyang, Ziqiang Qu, Qiu Wang, Huafeng Liu, Liang-Cheng Tu

    Miniaturized accelerometers are in high demand for consumer electronics, acoustic monitoring, and unmanned aerial vehicles. However, there is a tradeoff between accelerometer resolution and size, which poses a major challenge. In this study, we introduce an optomechanical microelectro mechanical system (MEMS) accelerometer based on a Fabry-Perot (F-P) microcavity. The F-P microcavity consists of a fixed hemispherical mirror and a harmonic oscillator made of monocrystalline silicon. Despite its small size (only 10 mm), the MEMS accelerometer exhibits an acceleration noise floor of 40 ng/Hz$^{1/2}$ at 180 Hz, a bandwidth of 500 Hz (-3 dB), and a dynamic range of 80 dB. To suppress dominant laser intensity noise and the disturbance of temperature and pressure on the optical fiber, a balanced detection method is employed, reducing the overall noise floor from 250 ng/Hz$^{1/2}$ to 40 ng/Hz$^{1/2}$, which approaches the mechanical thermal noise limit (37 ng/Hz$^{1/2}$). These results demonstrate that the opto-mechanical coupling between the oscillator and microcavity is an excellent platform for precision measurement and opto-mechanics, benefiting from its extremely small mode volume and ability to restrain photons.


  • On the Air Buoyancy Effect in MEMS-Based Gravity Sensors for High Resolution Gravity Measurements

    by Xiaochao Xu, Qian Wang, Ji'AO Tian, Lujia Yang, Yanyan Fang, Qiu Wang, Chun Zhao, Fangjing Hu, Liangcheng Tu

    In this paper, the air buoyancy effect on Micro-Electro-Mechanical System (MEMS)-based gravity sensors for high-resolution gravity measurements is investigated. The MEMS gravimeter is operated in an atmospheric environment without any vacuum chamber; thus significantly simplifying the design, implementation and maintenance, and reducing the cost of the instrument. It is experimentally observed that the measured acceleration signal shows a clear correlation with the air buoyancy, and consequently the air pressure. A detailed theoretical model of the air buoyant force acting on the MEMS gravity sensor is proposed, giving a gravity-air pressure coefficient of 501.5 μGal/hPa for the silicon spring-mass system. After removing the error introduced by the air buoyant force, the MEMS gravity sensor exhibits an ultra-low self-noise floor of 1 μGal/√Hz@1 Hz, as well as an excellent stability, with an Allan deviation of 3 μGal (40 s integration time). The sensor is capable of measuring the Earth tides in a 16-day span. This discovery identified one major error source in high-resolution MEMS gravity sensors operating in atmosphere, which could potentially be useful for the development of future MEMS-based gravimeters.


  • MEMS Microgravity Measurement Module with Nano-g/Hz Noise Floor for Spaceborne Higher-Level Microgravity Scientific Experiment Applications

    by Qiu Wang, Zongfeng Li, Huafeng Liu, Qiangwei Xu, Shitao Yan, Leiming Zhang, Shaolin Zhang, Xiaoxiao Song, Ziqiang Qu, Li Liu, et al.


  • Open Access

    A Universal High-Sensitivity Area-Variation Capacitive Displacement Transducer (CDT) Based on Fringe Effect

    by Qiu Wang, Shitao Yan, Qiangwei Xu, Shaolin Zhang, Xiaoxiao Song, Chun Zhao, Fangjing Hu, Huafeng Liu, Liangcheng Tu

    Capacitive displacement transducers (CDTs) have been widely used in many physical sensors, attributing to high-resolution, simple electricity and easy manufacturing process. Gap-variation CDTs generally have higher displacement resolution due to small electrode gaps but suffer from the pull-in effect, the nonlinear effect and squeeze-film damping; whereas area-variation CDTs have intrinsically good linearity and much smaller slide-film damping. However, the parallel-plate-based area-variation CDTs have the electrode width much larger than the electrode gap with negligible fringe effect; therefore, the sensitivity is limited by periodic electrode numbers. In this paper, we introduce a novel fringe-effect dominated area-variation CDT with a much higher sensitivity within a certain electrode-deployable area. Both theoretical and numerical analysis are applied to investigate the working principle of the CDT design. The proposed fringe-effect-based CDT benefits from a much larger capacitance-to-displacement sensitivity than the traditional periodic array parallel-plate-based CDT, due to the more displacement-sensitive fringe field and more deployable electrode periods. A set of experiments are designed, and the proposed area-variation CDTs are evaluated. Experimental results suggested that the proposed CDT design, which had equal electrode width, separation and gap, could universally be applied to sensors with different featured dimensions either in macroscale or microscale. Angular misalignments with both out-of-plane tilts and in-plane rotations, which affect the output offset and sensitivity, should be minimized or alleviated. The proposed fringe-effect-based CDT are successfully applied to a single-axis in-plane sensing micro-electromechanical systems (MEMS) accelerometer, showing a noise floor as low as 0.25 ng/Hz $^{\mathrm {1/2}}$ @1 Hz. The corresponding displacement noise of the proposed CDT is 0.1 pm/Hz $^{\mathrm {1/2}}$ .