FMFri Murdiya

Fri Murdiya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fri Murdiya has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental and DFT investigation of LiFePO₄/graphene composites prepared via shear exfoliation route

    by Amun Amri, Mawaddah Mawaddah, Alfatlian Alfatlian, Sunarno Sunarno, Fri Murdiya, Mazhibayev Assylzhan, Khairulazhar Jumbri, Mohammednoor Altarawneh, Chun-Chen Yang, Sulistyo Saputro, et al.

    The performance of LiFePO₄ (LFP) cathodes was successfully enhanced by incorporating two types of graphene obtained through green and low-cost liquid shear exfoliation processes. Commercial LFP was combined with few-layer graphene (FLG) and very few-layer graphene (VFLG), with compositions ranging from 0-4 wt.%. LFP, LFP/FLG, and LFP/VFLG, were characterized using electrochemical impedance spectroscopy (EIS), charge–discharge (CD), XRD, FTIR, and FESEM–EDX. Density functional theory (DFT) calculations were further employed to probe the electronic structure of LFP and an idealized LFP(001)/pristine-graphene interface as a baseline model for interfacial electronic coupling. DFT indicated interfacial charge redistribution and the emergence of C-2p π-derived states near the Fermi level, resulting in bandgap narrowing relative to pristine LFP and suggesting an additional electronic percolation pathway at the interface. Experimentally, EIS showed that VFLG reduced charge-transfer resistance and increased effective electrochemical conductivity, while FLG addition was associated with improved interfacial charge-transfer behavior inferred from EIS. CD tests at 0.5 C showed that the 4 wt.% FLG and 4 wt.% VFLG electrodes delivered the highest specific capacities of 29.98 mAh/g and 44.66 mAh/g, corresponding to increases of 81.9% and 170.5% compared to bare LFP. XRD and FTIR confirmed that LFP phase integrity was maintained, and FESEM–EDX revealed a uniform particle distribution with well-dispersed graphene networks. Overall, these results demonstrated that shear-exfoliated graphene effectively improved electronic connectivity and charge-transfer behavior in LFP cathodes, supported by consistent electrochemical measurements and electronic-structure insights from DFT.


  • Open Access

    Mechanical enhancement of natural-curing geopolymer via shear-exfoliation graphene addition for sustainable paving blocks

    by Amun Amri, Rahmat Zega, Namira Herliana Putri, Dhina Febryza, Desi Heltina, Azhari Azhari, Bambang Sujatmoko, Fri Murdiya

    The compressive strength and surface hardness of fly-ash based geopolymer paving block composites (GPBC), fabricated in a room temperture curing process (natural curing), have been successfully improved with the addition of low-cost liquid shear-exfoliation graphene (LSE-G) additives. The...


  • Open Access

    Carbon Conversion Using High Voltage Plasma Method Based on Mangrove Wood Charcoal

    by Robi Aldi, Feranita Feranita, Fri Murdiya, Ery Safrianti, Linna Oktaviana Sari

    This study investigates the conversion of mangrove wood charcoal into graphene using high voltage plasma technology through arc discharge. The experiment involves heating carbon with high voltage plasma generated from rod and plate electrodes. The variables examined are the electrode distance and carbon treatment time. The results demonstrate the successful conversion of mangrove wood charcoal into graphene. The generated plasma is influenced by the electrode distance, with a 1 cm gap producing stronger bluish-orange plasma. Varying the treatment time also affects the graphene yield, with a 3-minute treatment generating more graphene compared to 2 minutes, and 2 minutes yielding more graphene than 1 minute. XRD analysis reveals characteristic peak shifts indicative of graphene presence. SEM analysis confirms the graphene structure with porous features and sub-micrometer sizes. SEM images and diameter data further validate the successful conversion of carbon into graphene. These findings provide a foundation for the development of high voltage plasma-based production of graphene from mangrove wood charcoal. The utilization of a 10kV Neon Power Supply transformer enables the generation of high voltage plasma for the carbon-to-graphene conversion process. The electrode distance in the transformer plays a crucial role, as greater distances result in higher voltages, while shorter distances lead to lower voltages. This research significantly contributes to expanding the knowledge and application of graphene in various scientific and engineering fields. Moreover, the understanding of how electrode distance affects the generated voltage using a Neon Power Supply transformer is an important finding for optimizing the performance of this type of transformer.


  • Open Access

    The Characteristics of Dielectric Barrier Discharge with Different Magnetic Field Intensity in Narrow Gap and Ozone Production

    by Fri Murdiya, Ivan Saputra, Agus Ernawan, Amir Hamzah, Firdaus, Ramdani

    This investigation is the implementation of high voltage generator with the topology push-pull inverter that connected to fly-back transformer. This generator is used to examine the ozone generator with DBD model and it was enhanced with the variation of magnetic field. The plasma in all models at a distance of 1.2 mm (narrow gap) are shown that the highest light intensity in model 1, while the lowest light intensity in model 4. The light intensity in model 1 are also higher than model 2 and 3, respectively. There are many current pulse or noises for model 1 and 2. However, there is a bit of current pulse in model 3 and 4. It is indicated that there are any micro discharges in the gap. Furthermore, the effect of intensity of magnetic field is influence the micro discharges in the gap. The DBD in model 1 produces maximum voltage and current of 8 kV and 37 mA, respectively. Model 2 is at 8.1 kV and 36 mA for maximum voltage and current, respectively. Finally, the model 4 adjusts the maximum current and voltage of 8.12 kV and 36 mA, respectively. It is indicated that the intensity of magnetic field influences the maximum voltage of DBD. Then, it is also shown that the maximum currents of DBD has varied. It is indicated that the intensity of magnetic field and attractive and repulsive conditions of magnet has also influenced the ozone production for all models. Model 3 of DBD produces higher ozone concentration than model 1,2 and 4, respectively.


  • Open Access

    Dielectric Barrier Discharge Induced By Permanent Magnet In Attraction And Repulsion Conditions For Ozone Generator

    by Fri Murdiya, Ivan Saputra

    Ozone is used in various area including medicine, drinking water treatment and waste treatment. Ozone can be produced using dielectric barrier discharge which is supplied by high voltage. High voltage occurs in the dielectric barrier discharge such as air gap that it is as a result of the failure of air in maintaining its insulator properties. Power supply used in this study is a parallel resonant push-pull inverter using a fly back transformer. In order to produce good plasma in producing ozone, a magnetic filed is added to dielectric barrier discharge. In this study, a magnet was placed on each anode and cathode electrode with the condition of attraction (model I) and repulsion (model II). The addition of two magnets to each electrode was also carried out under the conditions of attraction (model III) and repulsion (model IV). It is shown that the plasma intensity in the model I and III was higher than model II and IV. The discharge current in the model I and III was higher than model II and IV. The highest ozone concentration was model III and the lowest ozone concentration was in model IV. Model I had a higher ozone concentration than model II.


  • Open Access

    The effect of lightning impulse characteristics and line arrester to the lightning protection performance on 150 kV overhead lines: ATP-EMTP computational approach

    by Fri Murdiya, Febrizal Febrizal, Cecilia Stevany, Havel Alindo Sano, Firdaus Firdaus

    This simulation study presents the effect of lightning strikes on the performance of arresters at 150 kV overhead lines. Lightning strikes have several parameters that affect the performance of line arresters (LA), namely lightning charge, and impulse energy. The simulation was attempted by injection of a direct strike to the ground wire with the peak voltage of 10 MV. The peak voltage was varied in terms of wavefront time (Tf) and the duration of lightning impulses (tau). In order to calculate current, charge and impulse energy of LA from various variations of Tf and tau, the trapezoidal numerical integration method is used. The current and impulse energy arising due to direct strikes and various variations of Tf and tau will be compared for each phase so that the influence of Tf and tau can be obtained from the performance of the LA and the current charge and impulse energy values are still within the limits of the IEEE C62.11 standard. The installation of LA and the position of arresters affected the peak voltage of lightning on the phase line when lightning struck it. The line arresters provide a drop in the peak voltage of lightning in phase lines. By installing line arresters in each tower, it will reduce the peak voltage of lightning on the phase line more significantly than the standalone line arrester. It is shown that the line arresters have to install at least six towers to reduce the peak voltage in the phase lines.


  • Open Access

    Evaluasi teknologi pencahayaan untuk ruangan kelas pada Pondok Pesantren Khairul Ummah

    by Azriyenni Azriyenni, Amir Hamzah, Riski Febriyursandi, Fri Murdiya, Nurhalim Nurhalim

    Pencahayaan dalam ruangan belajar yang baik akan menciptakan kenyamanan disetiap kegiatan adalah hal yang sangat baik. Pemasangan dan ketersediaan titik lampu dan jenis lampu yang baik dan tepat dapat mempengaruhi kondisi pencahayaan dalam sebuah ruangan. Permasalahannya adalah pemasangan titik lampu dan jenis lampu yang tidak sesuai dengan standar telah ditetapkan di Indonesia, dan ianya akan menyebabkan kerugian kepada manusia berupa gangguan pada fungsi mata. Tujuan pengabdian kepada masyarakat ini adalah untuk meningkatkan penerangan dan teknologi pencahayaan yang baik pada beberapa ruangan belajar (kelas) di MA dan MTs Pondok Pesantren Khairul Ummah. Kemudian, meningkatkan kualitas penerangan dan pencahayaan pada ruang belajar berbasis perangkat lunak. Metode yang akan dijalankan dalam pengabdian kepada masyarakat ini adalah mendesain dan teknik pencahayaan yang baik menggunakan perangkat lunak DIALux evo 8.1.

  • Open Access

    The Properties of Nitrogen Gas Breakdown Voltage under Direct Current Positive Polarity

    by Fri Murdiya, Firdaus Firdaus, Tumpal Pardede, Eddy Hamdani

    The type of insulation gases that are usually used in the power circuit breaker (circuit breaker) is the sulfur hexafluoride (SF6) gas, nitrogen (N2) and carbon dioxide (CO2). Most of the electric power systems are using insulating materials such as sulfur hexafluoride (SF6). Sulfur hexafluoride gas (SF6) has a higher dielectric strength than the air. However, Sulfur hexafluoride (SF6) gas is not friendly environmentally and very impact on global warming. The purpose of this study was to test the breakdown voltage of nitrogen gas (N2) (more friendly environmental) as alternative insulation of sulfur hexafluoride (SF6) gas. This study was used sphere and needle electrodes with a distance of 0.5-2 cm and a pressure of 1-4 bar; it was tested for 20 times. From the test results, it obtained that the breakdown voltage of sphere electrodes is more significant than the needle electrodes. Sphere and needle electrodes with a distance of 2 cm and a pressure of 4 bar have a most excellent value of breakdown voltage at the voltage of 140 kV and 79 kV, respectively.


  • When plasma jet is effective for chronic wound bacteria inactivation, is it also effective for wound healing?

    by Sri Darmawati, Afiana Rohmani, Laela Hayu Nurani, Muhammad Evy Prastiyanto, Sri Sinto Dewi, Nia Salsabila, Eka Sakti Wahyuningtyas, Fri Murdiya, Isabella Meliawati Sikumbang, Ratnasari Nur Rohmah, et al.


  • The performance surface barrier discharge in magnetic field driven by series resonance converter

    by Fri Murdiya, Febrizal

    In this research, the application of series resonance converter driving surface barrier discharge (high voltage plasma generator) was carried out. The high voltage is about 5 kV in frequency of 25 kHz was connected to a circular aluminum plate, it was used as an anode electrode and a rectangular aluminum plate was installed as a cathode electrode. These electrodes were separated by using a glass dielectric as barrier. The effect of magnetic field for producing plasma in surface barrier was shown detail different with surface barrier discharge without magnetic field. It is indicated that the discharge current in magnetic field is lower than without magnetic field. The plasma on surface barrier in magnetic field was more luminous rather than without magnetic field. It also indicated that the area of Lissajous diagram for surface barrier discharge in magnetic field was slightly decreased than without magnetic field. It could be concluded that the effect magnetic field would influence to the plasma progress on surface barrier.