Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kosuke Hata has a total of 66 co-authors. Here are the top co-authors by number of shared publications:

  • Takeshi Bamba

    Medical Institute of Bioregulation, Kyushu University

    8 shared publications
  • Yoshihiro Izumi

    Division of Metabolomics, Medical Research Center for High Depth Omics, Medical Institute of Bioregulation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Fukuoka, Japan

    8 shared publications
  • Masatomo Takahashi

    Division of Metabolomics, Medical Research Center for High Depth Omics, Medical Institute of Bioregulation, Kyushu University, Fukuoka, Japan

    6 shared publications
  • Akiyoshi Hirayama

    Institute for Advanced Biosciences, Keio University, Yamagata, Japan

    2 shared publications
  • Daisuke Saigusa

    Faculty of Pharmaceutical Sciences, Teikyo University, Itabashi-Ku, Tokyo, Japan

    2 shared publications
  • Fumio Matsuda

    Department of Bioinformatic Engineering, Graduate School of Information Science and Technology, The University of Osaka, 1-5 Yamadaoka, Suita, Osaka 565-0871, Japan; The University of Osaka Shimadzu Omics Innovation Research Laboratories, The University of Osaka, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan; Industrial Biotechnology Initiative Division, Institute for Open and Transdisciplinary Research Initiatives, The University of Osaka, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan

    2 shared publications

Latest Publications

  • Open Access

    Single-cell mass spectrometry imaging of lipids in HeLa cells via tapping-mode scanning probe electrospray ionization

    by Yoichi Otsuka, Kazuya Kabayama, Ayane Miura, Masatomo Takahashi, Kosuke Hata, Yoshihiro Izumi, Takeshi Bamba, Koichi Fukase, Michisato Toyoda

    The development of analytical technology that allows investigation of the diversity of cells that form biological tissues based on molecular information is important to elucidate the heterogeneity of cells and pathological mechanisms. Here, we present a proof-of-concept demonstration of single-cell mass spectrometry imaging (SC-MSI) via tapping-mode scanning probe electrospray ionization (t-SPESI), which is an atmospheric-pressure sampling ionization technique. We developed a novel t-SPESI unit that can be used in combination with an inverted fluorescence microscope and basic technologies to extract components from microregions of cells and measure ions with high sensitivity. We performed multimodal (fluorescence, lipid ion, and topographic) imaging of two types of HeLa cells labeled with fluorescent dyes and chemically fixed and showed the potential for subcellular-scale analysis of both cell structure and chemical composition. Furthermore, we evaluated the lipid species by comparing the SC-MSI results with those of supercritical fluid chromatography tandem mass spectrometry. The technical advancement presented here is effective for distinguishing cell types based on the signal intensity of lipid ions in single cells and investigating differences in the subcellular localization of lipids in different types of cells.


  • Open Access

    Characterizing lipoprotein profiles in coronary atherosclerosis development through quantitative lipidomics and proteomics approaches

    by Hiroaki Takeda, Yoshihiro Izumi, Yui Koike, Tomonari Koike, Kohta Nakatani, Kosuke Hata, Masaki Matsumoto, Masashi Shiomi, Takeshi Bamba

    Lipoproteins, which are synthesized in hepatic cells and secreted into the blood, play an important role in lipid transport. The quality of lipoproteins, including small dense low-density lipoproteins and the cholesterol efflux capacity of high-density lipoproteins, influences cardiovascular outcomes, although the relationship between lipid changes and lipoprotein quality remains unclear. This study characterized lipid molecules and apolipoproteins in lipoprotein particles during the development of coronary atherosclerosis in myocardial infarction-prone rabbits. Using quantitative lipidomics and proteomics techniques, the lipid composition in lipoprotein particles was evaluated by normalizing lipidomics data with lipoprotein particle numbers estimated by apolipoprotein B-100 concentration. While apolipoproteins and common risk factors for abnormal lipid metabolism, including cholesterol and triacylglycerol, did not change across stages of coronary atherosclerosis, ceramide molecules in lipoprotein particles were significantly associated with early stage progression. This study provides a perspective on the role of lipid composition in the progression of coronary atherosclerosis.

  • Open Access

    Membrane structure-responsive lipid scrambling by TMEM63B to control plasma membrane lipid distribution

    by Yugo Miyata, Katsuya Takahashi, Yongchan Lee, Cheryl S. Sultan, Risa Kuribayashi, Masatomo Takahashi, Kosuke Hata, Takeshi Bamba, Yoshihiro Izumi, Kehong Liu, et al.

    Phospholipids are asymmetrically distributed in the plasma membrane (PM), with phosphatidylcholine and sphingomyelin abundant in the outer leaflet. However, the mechanisms by which their distribution is regulated remain unclear. Here, we show that transmembrane protein 63B (TMEM63B) functions as a membrane structure-responsive lipid scramblase localized at the PM and lysosomes, activating bidirectional lipid translocation upon changes in membrane curvature and thickness. TMEM63B contains two intracellular loops with palmitoylated cysteine residue clusters essential for its scrambling function. TMEM63B deficiency alters phosphatidylcholine and sphingomyelin distributions in the PM. Persons with heterozygous mutations in TMEM63B are known to develop neurodevelopmental disorders. We show that V44M, the most frequent substitution, confers constitutive scramblase activity on TMEM63B, disrupting PM phospholipid asymmetry. We determined the cryo-electron microscopy structures of TMEM63B in its open and closed conformations, uncovering a lipid translocation pathway formed in response to changes in the membrane environment. Together, our results identify TMEM63B as a membrane structure-responsive scramblase that controls PM lipid distribution and we reveal the molecular basis for lipid scrambling and its biological importance.


  • Open Access

    In-Needle Pre-Column Derivatization for Amino Acid Quantification (iPDAQ) Using HPLC

    by Yuki Soma, Yoshihiro Izumi, Takehiko Shimohira, Masatomo Takahashi, Yuri Imado, Saki Tominaga, Kanako Tokito, Kosuke Hata, Shoji Shinadama, Mana Oshiro, et al.

    Pre-column fluorescent derivatization has been used for the fast quantification of amino acids using high-performance liquid chromatography (HPLC) systems. However, it generally requires an offline in-vial derivatization process with multiple derivatization reagents. The offline derivatization requires the same number of reaction vials as the number of sample vials for use as a reaction chamber for the derivatization reaction in an autosampler. Therefore, the number of samples analyzed per batch using the pre-column derivatization method is halved. To benefit from the pre-column derivatization method, we transformed the derivatization process from an offline chamber process to an online in-needle process (in-needle Pre-column Derivatization for Amino acids Quantification; iPDAQ). Fluorescent derivatization in the injection needle obviated the need for vacant vials as reaction chambers. Consequently, the throughput per batch improved up to two times, and the consumption of derivatization reagents was reduced to less than one-tenth of that in the conventional vial method. We demonstrated to separate and quantify the amino acids in various biological samples. Herein, we presented a novel HPLC-based amino acid quantification method that enables the continuous analysis of a large number of samples. The iPDAQ facilitates accurate amino acid quantification due to the automation of derivatization and achieves improvement in the throughput and reduction of analysis labor.


  • Open Access

    Comparative Evaluation of Plasma Metabolomic Data from Multiple Laboratories

    by Shin Nishiumi, Yoshihiro Izumi, Akiyoshi Hirayama, Masatomo Takahashi, Motonao Nakao, Kosuke Hata, Daisuke Saigusa, Eiji Hishinuma, Naomi Matsukawa, Suzumi M. Tokuoka, et al.

    In mass spectrometry-based metabolomics, the differences in the analytical results from different laboratories/machines are an issue to be considered because various types of machines are used in each laboratory. Moreover, the analytical methods are unique to each laboratory. It is important to understand the reality of inter-laboratory differences in metabolomics. Therefore, we have evaluated whether the differences in analytical methods, with the exception sample pretreatment and including metabolite extraction, are involved in the inter-laboratory differences or not. In this study, nine facilities are evaluated for inter-laboratory comparisons of metabolomic analysis. Identical dried samples prepared from human and mouse plasma are distributed to each laboratory, and the metabolites are measured without the pretreatment that is unique to each laboratory. In these measurements, hydrophilic and hydrophobic metabolites are analyzed using 11 and 7 analytical methods, respectively. The metabolomic data acquired at each laboratory are integrated, and the differences in the metabolomic data from the laboratories are evaluated. No substantial difference in the relative quantitative data (human/mouse) for a little less than 50% of the detected metabolites is observed, and the hydrophilic metabolites have fewer differences between the laboratories compared with hydrophobic metabolites. From evaluating selected quantitatively guaranteed metabolites, the proportion of metabolites without the inter-laboratory differences is observed to be slightly high. It is difficult to resolve the inter-laboratory differences in metabolomics because all laboratories cannot prepare the same analytical environments. However, the results from this study indicate that the inter-laboratory differences in metabolomic data are due to measurement and data analysis rather than sample preparation, which will facilitate the understanding of the problems in metabolomics studies involving multiple laboratories.


  • Open Access

    Calibration-Curve-Locking Database for Semi-Quantitative Metabolomics by Gas Chromatography/Mass Spectrometry

    by Kosuke Hata, Yuki Soma, Toshiyuki Yamashita, Masatomo Takahashi, Kuniyo Sugitate, Takeshi Serino, Hiromi Miyagawa, Kenichi Suzuki, Kayoko Yamada, Takatomo Kawamukai, et al.

    Calibration-Curve-Locking Databases (CCLDs) have been constructed for automatic compound search and semi-quantitative screening by gas chromatography/mass spectrometry (GC/MS) in several fields. CCLD felicitates the semi-quantification of target compounds without calibration curve preparation because it contains the retention time (RT), calibration curves, and electron ionization (EI) mass spectra, which are obtained under stable apparatus conditions. Despite its usefulness, there is no CCLD for metabolomics. Herein, we developed a novel CCLD and semi-quantification framework for GC/MS-based metabolomics. All analytes were subjected to GC/MS after derivatization under stable apparatus conditions using (1) target tuning, (2) RT locking technique, and (3) automatic derivatization and injection by a robotic platform. The RTs and EI mass spectra were obtained from an existing authorized database. A quantifier ion and one or two qualifier ions were selected for each target metabolite. The calibration curves were obtained as plots of the peak area ratio of the target compounds to an internal standard versus the target compound concentration. These data were registered in a database as a novel CCLD. We examined the applicability of CCLD for analyzing human plasma, resulting in time-saving and labor-saving semi-qualitative screening without the need for standard substances.


  • Open Access

    An Analytical System for Single-Cell Metabolomics of Typical Mammalian Cells Based on Highly Sensitive Nano-Liquid Chromatography Tandem Mass Spectrometry

    by Kohta Nakatani, Yoshihiro Izumi, Kousuke Hata, Takeshi Bamba

    The rapid development of next-generation sequencing techniques has enabled single-cell genomic and transcriptomic analyses, which have revealed the importance of heterogeneity in biological systems. However, analytical methods to accurately identify and quantify comprehensive metabolites from single mammalian cells with a typical diameter of 10–20 μm are still in development. The aim of this study was to develop a single-cell metabolomic analytical system based on highly sensitive nano-liquid chromatography tandem mass spectrometry (nano-LC/MS/MS) with multiple reaction monitoring. A packed nano-LC column (3-μm particle-size pentafluorophenylpropyl particles of dimensions 100 μm × 180 mm) was prepared using a slurry technique. The optimized nano-LC/MS/MS method showed 3–132-fold (averaged value, 26-fold) greater sensitivity than semimicro-LC/MS/MS, and the detection limits of several hydrophilic metabolites, including amino acids and nucleic acid related metabolites were in the sub-fmol range. By combining live single-cell sampling and nano-LC/MS/MS, we successfully detected 18 relatively abundant hydrophilic metabolites (16 amino acids and 2 nucleic acid related metabolites) from single HeLa cells (n = 22). Based on single-cell metabolic profiles, the 22 HeLa cells were classified into three distinct subclasses, suggesting differences in metabolic function in cultured HeLa cell populations. Our single-cell metabolomic analytical system represents a potentially useful tool for in-depth studies focused on cell metabolism and heterogeneity.


  • Open Access

    Inter-Laboratory Comparison of Metabolite Measurements for Metabolomics Data Integration

    by Yoshihiro Izumi, Fumio Matsuda, Akiyoshi Hirayama, Kazutaka Ikeda, Yoshihiro Kita, Kanta Horie, Daisuke Saigusa, Kosuke Saito, Yuji Sawada, Hiroki Nakanishi, et al.

    Background: One of the current problems in the field of metabolomics is the difficulty in integrating data collected using different equipment at different facilities, because many metabolomic methods have been developed independently and are unique to each laboratory. Methods: In this study, we examined whether different analytical methods among 12 different laboratories provided comparable relative quantification data for certain metabolites. Identical samples extracted from two cell lines (HT-29 and AsPc-1) were distributed to each facility, and hydrophilic and hydrophobic metabolite analyses were performed using the daily routine protocols of each laboratory. Results: The results indicate that there was no difference in the relative quantitative data (HT-29/AsPc-1) for about half of the measured metabolites among the laboratories and assay methods. Data review also revealed that errors in relative quantification were derived from issues such as erroneous peak identification, insufficient peak separation, a difference in detection sensitivity, derivatization reactions, and extraction solvent interference. Conclusion: The results indicated that relative quantification data obtained at different facilities and at different times would be integrated and compared by using a reference materials shared for data normalization.