Boyang Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Boyang Zhao has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Shenquan Liu
Department of Electrical Engineering, South China University of Technology, Guangzhou, China
4 shared publications Xifan Wang
4 shared publications- Gang Wang
School of Electric Power Engineering, South China University of Technology, Guangzhou 510641, China
2 shared publications Xiuli Wang
2 shared publicationsBangyan Wang
1 shared publicationFengting Wei
1 shared publication
Latest Publications
- Open Access
- 15 May 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 169
Stability and mutual effect analysis of the virtual synchronous generator based interconnected AC/DC systems
- 15 May 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 169
Open AccessStability and mutual effect analysis of the virtual synchronous generator based interconnected AC/DC systems
- 31 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3855-3862
Upgrading Transmission Capacity by Altering HVAC Into Fractional Frequency Transmission System
Transmission adequacy of power system has been challenged by high investment of new line construction and limit line-corridor space. In this paper, a novel solution to increase transmission capacity by altering HVAC lines into fractional frequency transmission system (FFTS) is proposed. FFTS is a transmission that utilizes a relatively low grid frequency, e.g., 50/3 Hz, to extend the transmission capacity of ac lines. The proposed solution can minimize the construction efforts since the existing HVAC transmission lines can be directly employed by FFTS without any change. The structure and principle of FFTS for transmission line conversion (TLC) are introduced firstly. Then, performance of conventional ac equipment in FFTS is evaluated and comparison with respective counterpart in HVDC is carried out. Next, the economic performance of FFTS for transmission capacity upgrade is conducted based on a typical benchmark, and sensitivity analysis results are presented to determine the economic zone of FFTS. The results show that the uniform annual value (UAV) of TLC into FFTS is 24.9% and 31.6% cheaper than TLC into HVDC and constructing new HVAC lines, respectively. Therefore, FFTS is a superior scheme for transmission capacity boost.
- 31 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3855-3862
Upgrading Transmission Capacity by Altering HVAC Into Fractional Frequency Transmission System
Transmission adequacy of power system has been challenged by high investment of new line construction and limit line-corridor space. In this paper, a novel solution to increase transmission capacity by altering HVAC lines into fractional frequency transmission system (FFTS) is proposed. FFTS is a transmission that utilizes a relatively low grid frequency, e.g., 50/3 Hz, to extend the transmission capacity of ac lines. The proposed solution can minimize the construction efforts since the existing HVAC transmission lines can be directly employed by FFTS without any change. The structure and principle of FFTS for transmission line conversion (TLC) are introduced firstly. Then, performance of conventional ac equipment in FFTS is evaluated and comparison with respective counterpart in HVDC is carried out. Next, the economic performance of FFTS for transmission capacity upgrade is conducted based on a typical benchmark, and sensitivity analysis results are presented to determine the economic zone of FFTS. The results show that the uniform annual value (UAV) of TLC into FFTS is 24.9% and 31.6% cheaper than TLC into HVDC and constructing new HVAC lines, respectively. Therefore, FFTS is a superior scheme for transmission capacity boost.
- 22 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3477-3490
Optimal Arm Current Reallocation of Modular Multilevel Matrix Converter Dedicated for Power Grid Interconnection
The modular multilevel matrix converter (M 3 C) is the high-power three-phase to three-phase AC/AC converter of the next generation. However, when the M 3 C is applied for power grid interconnection, with equal or close input and output frequency, the current distribution in its nine arms becomes significantly uneven. Furthermore, the current distribution pattern is directly influenced by the randomly changing input-output angle-difference, forcing each arm to be designed based on the highest-possible current, which significantly increases the required semiconductor rating and converter cost. To address this issue, a novel current reallocation is proposed to attenuate the highest-possible arm current of M 3 C. The equal-frequency operation of M 3 C is first modeled and analyzed, and the operation sweet-spot where each arm stays in natural energy balance is located. Then, the current reallocation is analytically derived for sweet-spot operation. By injecting proper circulating current, the highest-possible arm current is reduced by 13.4%, and the required circulating current component is analytically derived. The implementation method into the classic control structure of M 3 C is provided. Performance of the proposed strategy is validated by a simulation benchmark established in MATLAB/Simulink environment in the context of interconnection between two 220 kV/50 Hz power grids.
- 22 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3477-3490
Optimal Arm Current Reallocation of Modular Multilevel Matrix Converter Dedicated for Power Grid Interconnection
The modular multilevel matrix converter (M 3 C) is the high-power three-phase to three-phase AC/AC converter of the next generation. However, when the M 3 C is applied for power grid interconnection, with equal or close input and output frequency, the current distribution in its nine arms becomes significantly uneven. Furthermore, the current distribution pattern is directly influenced by the randomly changing input-output angle-difference, forcing each arm to be designed based on the highest-possible current, which significantly increases the required semiconductor rating and converter cost. To address this issue, a novel current reallocation is proposed to attenuate the highest-possible arm current of M 3 C. The equal-frequency operation of M 3 C is first modeled and analyzed, and the operation sweet-spot where each arm stays in natural energy balance is located. Then, the current reallocation is analytically derived for sweet-spot operation. By injecting proper circulating current, the highest-possible arm current is reduced by 13.4%, and the required circulating current component is analytically derived. The implementation method into the classic control structure of M 3 C is provided. Performance of the proposed strategy is validated by a simulation benchmark established in MATLAB/Simulink environment in the context of interconnection between two 220 kV/50 Hz power grids.
- 5 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (3) , 1744-1755
An Improved Phasor Method for Modelling and Analysis of Modular Multilevel Matrix Converter
modular multilevel matrix converter (M3C) has considerable application potential in motor driving and power systems, but its phasor model is rarely studied. This paper proposes a novel method for modelling and analysis of the M3C in the phasor domain. Firstly, an improved phasor method in matrix form is proposed for direct AC/AC MMC family. By including the frequency information into the phasor expression, it is capable of analysis towards interaction between AC variable groups with different frequencies. Secondly, based on the proposed phasor matrix method, the concept of two-dimensional phase-sequence is proposed to facilitate description and calculation of the AC variables in the 3-by-3 matrix-resembled circuit structure of M3C. Network of each phase-sequence is also derived. With the proposed methods, calculation burden for modelling and analysis of the M3C is significantly reduced. Then, the phasor model of M3C considering the DC, fundamental frequency and 2nd-order harmonic components is established. Finally, validation results with time-domain simulation is provided.
- 5 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (3) , 1744-1755
An Improved Phasor Method for Modelling and Analysis of Modular Multilevel Matrix Converter
modular multilevel matrix converter (M3C) has considerable application potential in motor driving and power systems, but its phasor model is rarely studied. This paper proposes a novel method for modelling and analysis of the M3C in the phasor domain. Firstly, an improved phasor method in matrix form is proposed for direct AC/AC MMC family. By including the frequency information into the phasor expression, it is capable of analysis towards interaction between AC variable groups with different frequencies. Secondly, based on the proposed phasor matrix method, the concept of two-dimensional phase-sequence is proposed to facilitate description and calculation of the AC variables in the 3-by-3 matrix-resembled circuit structure of M3C. Network of each phase-sequence is also derived. With the proposed methods, calculation burden for modelling and analysis of the M3C is significantly reduced. Then, the phasor model of M3C considering the DC, fundamental frequency and 2nd-order harmonic components is established. Finally, validation results with time-domain simulation is provided.
- 11 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 7 (4) , 2292-2302
A Current Reallocation Strategy to Attenuate the Peak Arm Current of the Modular Multilevel Matrix Converter
The modular multilevel matrix converter (M3C) is a promising candidate for direct AC to AC conversion systems. This paper proposes a novel arm current reallocation strategy for the M3C to attenuate the peak arm current. The principle of the proposed strategy is to dynamically adjust the distribution of the positive-sequence current components among the three star-figure subconverters according to their respective instantaneous zero-sequence current components. First, a square-value-based strategy is proposed and its performance in attenuating the peak arm current at different current conversion ratios is evaluated. Then, the impacts of the proposed strategy on the root-mean-square value of the arm current and submodule capacitor voltages ripple are analyzed. Based on the analysis, an algorithm for determination of the reallocation efficient, and embedment of the proposed strategy in the existing control methods is developed. Based on the proposed strategy and depending on the current conversion ratio of the M3C, up to 14.6% to 21.6% of the peak arm current can be attenuated. Performance and effectiveness of the proposed current reallocation strategy are verified by simulation studies conducted in the MATLAB/Simulink software environment.
- 11 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 7 (4) , 2292-2302
A Current Reallocation Strategy to Attenuate the Peak Arm Current of the Modular Multilevel Matrix Converter
The modular multilevel matrix converter (M3C) is a promising candidate for direct AC to AC conversion systems. This paper proposes a novel arm current reallocation strategy for the M3C to attenuate the peak arm current. The principle of the proposed strategy is to dynamically adjust the distribution of the positive-sequence current components among the three star-figure subconverters according to their respective instantaneous zero-sequence current components. First, a square-value-based strategy is proposed and its performance in attenuating the peak arm current at different current conversion ratios is evaluated. Then, the impacts of the proposed strategy on the root-mean-square value of the arm current and submodule capacitor voltages ripple are analyzed. Based on the analysis, an algorithm for determination of the reallocation efficient, and embedment of the proposed strategy in the existing control methods is developed. Based on the proposed strategy and depending on the current conversion ratio of the M3C, up to 14.6% to 21.6% of the peak arm current can be attenuated. Performance and effectiveness of the proposed current reallocation strategy are verified by simulation studies conducted in the MATLAB/Simulink software environment.