Julie Lizon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Julie Lizon has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Arnaud Florentin
Department of Hygiene, Environmental Risks and Healthcare Associated Risks, University of Lorraine, Vandoeuvre-lès-Nancy, Nancy, France; Université de Lorraine, APEMAC, F-54000, Nancy, France
6 shared publications - Alexandre Baudet
Université de Lorraine, faculté d'odontologie Vandœuvre‐lès‐Nancy France
5 shared publications - Cédric Dananché
Department of Hospital Hygiene, Epidemiology, and Prevention, Croix-Rousse University Hospital, Lyon, France
2 shared publications - Céline Clément
Laboratoire Éducation Éthique Santé EA7505, Université de Tours, 37044 Tours Cédex 9, France
2 shared publications - Frédéric Camelot
Dental Private Practice, 88300 Neufchateau, France
2 shared publications - Jean-Marc Martrette
Faculty of Dentistry, University of Lorraine, 54505 Vandœuvre-lès-Nancy, France
2 shared publications
Latest Publications
- Open Access
- 19 December 2024
- Published by Springer Nature in BMC Microbiology
- Vol. 24 (1) , 1-7
Bacterial contamination of new dental unit waterlines and efficacy of shock disinfection
Bacterial contamination of outlet water from dental unit waterlines (DUWLs) may lead to healthcare-associated infection. The aim of this study was to evaluate the contamination of DUWLs from new dental chairs before and after their initial shock disinfection with ICX Renew® and to determine the efficacy of this method of shock disinfection. The microbiological quality of water samples obtained from the DUWLs of 17 new dental chairs installed at the University Hospital of Nancy, France, was assessed. Water samples were collected before and after an initial shock disinfection with one ICX Renew® treatment. Water analysis was used to assess total culturable aerobic bacteria (TCAB) at 22°C and 36°C, Legionella sp., Pseudomonas aeruginosa and total coliforms. All the DUWLs (17/17) were contaminated by viable aerobic bacteria (TCAB at 22°C and 36°C > 300 CFU/mL), including P. aeruginosa, before shock disinfection. After shock disinfection with ICX Renew®, 24% of DUWLs (4/17) remained contaminated by aerobic bacteria (TCAB at 36°C > 300 CFU/mL for 3/17) and P. aeruginosa (> 100 CFU/100 mL for 1/17). To reduce the contamination of new dental chairs, initial shock disinfection of DUWLs should be performed to remove biofilms and bacteria from the DUWLs. To ensure the security of care, microbiological analysis of outlet water from DUWLs should be systematically performed before the first clinical use of a new dental chair to determine the efficacy of shock disinfection and the agreement of the results with the dental recommendations for water quality. Not applicable.
- 19 December 2024
- Published by Springer Nature in BMC Microbiology
- Vol. 24 (1) , 1-7
Open AccessBacterial contamination of new dental unit waterlines and efficacy of shock disinfection
Bacterial contamination of outlet water from dental unit waterlines (DUWLs) may lead to healthcare-associated infection. The aim of this study was to evaluate the contamination of DUWLs from new dental chairs before and after their initial shock disinfection with ICX Renew® and to determine the efficacy of this method of shock disinfection. The microbiological quality of water samples obtained from the DUWLs of 17 new dental chairs installed at the University Hospital of Nancy, France, was assessed. Water samples were collected before and after an initial shock disinfection with one ICX Renew® treatment. Water analysis was used to assess total culturable aerobic bacteria (TCAB) at 22°C and 36°C, Legionella sp., Pseudomonas aeruginosa and total coliforms. All the DUWLs (17/17) were contaminated by viable aerobic bacteria (TCAB at 22°C and 36°C > 300 CFU/mL), including P. aeruginosa, before shock disinfection. After shock disinfection with ICX Renew®, 24% of DUWLs (4/17) remained contaminated by aerobic bacteria (TCAB at 36°C > 300 CFU/mL for 3/17) and P. aeruginosa (> 100 CFU/100 mL for 1/17). To reduce the contamination of new dental chairs, initial shock disinfection of DUWLs should be performed to remove biofilms and bacteria from the DUWLs. To ensure the security of care, microbiological analysis of outlet water from DUWLs should be systematically performed before the first clinical use of a new dental chair to determine the efficacy of shock disinfection and the agreement of the results with the dental recommendations for water quality. Not applicable.
- Open Access
- 4 June 2024
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 12 (6) , e0396223
Initial waterline contamination by Pseudomonas aeruginosa in newly installed dental chairs
Water contamination in dental unit waterlines (DUWLs) is a potential source of healthcare-associated infection during dental care. The aim of this study was to evaluate the microbiological quality of DUWLs water from newly installed dental chairs in a French University Hospital. The microbiological quality of water from 24 new DUWLs initially disinfected by ICX Renew—prior to use of the dental units for patient treatment—was assessed for total culturable aerobic bacteria at 22°C and 36°C, Legionella sp. , Pseudomonas aeruginosa , and total coliforms. Among the 24 samples analyzed, 21 were compliant with the water quality levels: 19 had no bacteria, and 2 contained only 4 and 1 CFU/mL for total culturable aerobic bacteria at 22°C and 36°C, respectively. Three samples were non-compliant due to contamination by P. aeruginosa (4, 2, and 2 CFU/100 mL). Controlling and preventing the microbiological contamination of DUWLs, especially by pathogenic bacteria, at the time of the installation of the new dental chairs are crucial to prevent healthcare-associated infection in dentistry. IMPORTANCE: Dental unit waterlines (DUWLs) of new dental chairs may be contaminated before their first clinical use, so an initial shock disinfection is crucial at the time of their installation. The microbiological analyses are crucial to control the water quality of DUWLs before their first clinical use because their disinfection does not guarantee the elimination of all bacteria.
- 4 June 2024
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 12 (6) , e0396223
Open AccessInitial waterline contamination by Pseudomonas aeruginosa in newly installed dental chairs
Water contamination in dental unit waterlines (DUWLs) is a potential source of healthcare-associated infection during dental care. The aim of this study was to evaluate the microbiological quality of DUWLs water from newly installed dental chairs in a French University Hospital. The microbiological quality of water from 24 new DUWLs initially disinfected by ICX Renew—prior to use of the dental units for patient treatment—was assessed for total culturable aerobic bacteria at 22°C and 36°C, Legionella sp. , Pseudomonas aeruginosa , and total coliforms. Among the 24 samples analyzed, 21 were compliant with the water quality levels: 19 had no bacteria, and 2 contained only 4 and 1 CFU/mL for total culturable aerobic bacteria at 22°C and 36°C, respectively. Three samples were non-compliant due to contamination by P. aeruginosa (4, 2, and 2 CFU/100 mL). Controlling and preventing the microbiological contamination of DUWLs, especially by pathogenic bacteria, at the time of the installation of the new dental chairs are crucial to prevent healthcare-associated infection in dentistry. IMPORTANCE: Dental unit waterlines (DUWLs) of new dental chairs may be contaminated before their first clinical use, so an initial shock disinfection is crucial at the time of their installation. The microbiological analyses are crucial to control the water quality of DUWLs before their first clinical use because their disinfection does not guarantee the elimination of all bacteria.
- Open Access
- 25 April 2024
- Published by MDPI AG in Antibiotics
- Vol. 13 (5) , 390
Pseudomonas aeruginosa Infections in Patients with Severe COVID-19 in Intensive Care Units: A Retrospective Study
Patients hospitalized in ICUs with severe COVID-19 are at risk for developing hospital-acquired infections, especially infections caused by Pseudomonas aeruginosa. We aimed to describe the evolution of P. aeruginosa infections in ICUs at CHRU-Nancy (France) in patients with severe COVID-19 during the three initial waves of COVID-19. The second aims were to analyze P. aeruginosa resistance and to describe the antibiotic treatments. We conducted a retrospective cohort study among adult patients who were hospitalized for acute respiratory distress syndrome due to COVID-19 and who developed a hospital-acquired infection caused by P. aeruginosa during their ICU stay. Among the 51 patients included, most were male (90%) with comorbidities (77%), and the first identification of P. aeruginosa infection occurred after a median ICU stay of 11 days. Several patients acquired infections with MDR (27%) and XDR (8%) P. aeruginosa strains. The agents that strains most commonly exhibited resistance to were penicillin + β-lactamase inhibitors (59%), cephalosporins (42%), monobactams (32%), and carbapenems (27%). Probabilistic antibiotic treatment was prescribed for 49 patients (96%) and was subsequently adapted for 51% of patients after antibiogram and for 33% of patients after noncompliant antibiotic plasma concentration. Hospital-acquired infection is a common and life-threatening complication in critically ill patients. Efforts to minimize the occurrence and improve the treatment of such infections, including infections caused by resistant strains, must be pursued.
- 25 April 2024
- Published by MDPI AG in Antibiotics
- Vol. 13 (5) , 390
Open AccessPseudomonas aeruginosa Infections in Patients with Severe COVID-19 in Intensive Care Units: A Retrospective Study
Patients hospitalized in ICUs with severe COVID-19 are at risk for developing hospital-acquired infections, especially infections caused by Pseudomonas aeruginosa. We aimed to describe the evolution of P. aeruginosa infections in ICUs at CHRU-Nancy (France) in patients with severe COVID-19 during the three initial waves of COVID-19. The second aims were to analyze P. aeruginosa resistance and to describe the antibiotic treatments. We conducted a retrospective cohort study among adult patients who were hospitalized for acute respiratory distress syndrome due to COVID-19 and who developed a hospital-acquired infection caused by P. aeruginosa during their ICU stay. Among the 51 patients included, most were male (90%) with comorbidities (77%), and the first identification of P. aeruginosa infection occurred after a median ICU stay of 11 days. Several patients acquired infections with MDR (27%) and XDR (8%) P. aeruginosa strains. The agents that strains most commonly exhibited resistance to were penicillin + β-lactamase inhibitors (59%), cephalosporins (42%), monobactams (32%), and carbapenems (27%). Probabilistic antibiotic treatment was prescribed for 49 patients (96%) and was subsequently adapted for 51% of patients after antibiogram and for 33% of patients after noncompliant antibiotic plasma concentration. Hospital-acquired infection is a common and life-threatening complication in critically ill patients. Efforts to minimize the occurrence and improve the treatment of such infections, including infections caused by resistant strains, must be pursued.
- 18 May 2023
- Published by Elsevier in Infectious Diseases Now
- Vol. 53 (6) , 104724
Carbapenemase-producing Enterobacteriaceae and vancomycin-resistant Enterococcus faecium: The value of a computerized monitoring system to limit their spread
- 18 May 2023
- Published by Elsevier in Infectious Diseases Now
- Vol. 53 (6) , 104724
Carbapenemase-producing Enterobacteriaceae and vancomycin-resistant Enterococcus faecium: The value of a computerized monitoring system to limit their spread
- 1 January 2023
- Published by JLE in Hépato-Gastro & Oncologie Digestive
- Vol. 30 (1) , 13-24
Recommandations de la Société Française d’Endoscopie Digestive (SFED), de la Société Française d’Hygiène Hospitalière (SF2H) et du Groupement Infirmier pour la Formation en Endoscopie (GIFE) pour l’organisation et le fonctionnement d’un plateau technique en endoscopie digestive
- 1 January 2023
- Published by JLE in Hépato-Gastro & Oncologie Digestive
- Vol. 30 (1) , 13-24
Recommandations de la Société Française d’Endoscopie Digestive (SFED), de la Société Française d’Hygiène Hospitalière (SF2H) et du Groupement Infirmier pour la Formation en Endoscopie (GIFE) pour l’organisation et le fonctionnement d’un plateau technique en endoscopie digestive
- Open Access
- 12 April 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (8) , 2634
Efficacy of BRS® and Alpron®/Bilpron® Disinfectants for Dental Unit Waterlines: A Six-Year Study
Biofilms in dental unit waterlines (DUWL) are a potentially significant source of contamination posing a significant health risk as these may come into contact with patients and dental staff during treatment. The aim of this study was to evaluate the microbiological quality of DUWL water treated by Biofilm-Removing-System® (BRS®) and Alpron®/Bilpron® disinfectant solutions for six years in a French university hospital. The microbiological quality of water supplied by 68 dental units—initially shock treated with BRS®, then continuously treated by Alpron® with sterile water during working days and Bilpron® during inactivity period, and combined with purging every morning and after each patient—was assessed biannually during six years for total culturable aerobic bacteria at 22 °C and 36 °C, Legionella sp., Pseudomonas aeruginosa, and total coliforms. A total of 628 samples were analyzed, 99.8% were compliant with extended microbiological levels, and we never detected pathogen bacteria like Legionella sp. and P. aeruginosa. Only one sample (0.2%) was noncompliant with the level of total culturable aerobic bacteria at 36 °C, which exceeded 140 colony forming units per mL. The protocol implemented in our university hospital gives excellent results and enables control of the microbiological quality of DUWL water in the long term.
- 12 April 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (8) , 2634
Open AccessEfficacy of BRS® and Alpron®/Bilpron® Disinfectants for Dental Unit Waterlines: A Six-Year Study
Biofilms in dental unit waterlines (DUWL) are a potentially significant source of contamination posing a significant health risk as these may come into contact with patients and dental staff during treatment. The aim of this study was to evaluate the microbiological quality of DUWL water treated by Biofilm-Removing-System® (BRS®) and Alpron®/Bilpron® disinfectant solutions for six years in a French university hospital. The microbiological quality of water supplied by 68 dental units—initially shock treated with BRS®, then continuously treated by Alpron® with sterile water during working days and Bilpron® during inactivity period, and combined with purging every morning and after each patient—was assessed biannually during six years for total culturable aerobic bacteria at 22 °C and 36 °C, Legionella sp., Pseudomonas aeruginosa, and total coliforms. A total of 628 samples were analyzed, 99.8% were compliant with extended microbiological levels, and we never detected pathogen bacteria like Legionella sp. and P. aeruginosa. Only one sample (0.2%) was noncompliant with the level of total culturable aerobic bacteria at 36 °C, which exceeded 140 colony forming units per mL. The protocol implemented in our university hospital gives excellent results and enables control of the microbiological quality of DUWL water in the long term.
- Open Access
- 1 November 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (21) , 4242
Dental Unit Waterlines: A Survey of Practices in Eastern France
Water is essential during dental care. Physical and chemical techniques should be used to maintain a good water quality with respect to bacteria, and to ensure the safety of exposed patients and dental staff. The aim of this survey was to assess the modalities used by dental practitioners in Eastern France to maintain the water quality of their dental unit waterlines (DUWLs). A questionnaire about water quality maintenance practices was sent to 870 dental offices in 2016. The questionnaires were completed by 153 dental offices, covering about 223 dental care units. The majority of units were fed by mains water (91.0%), which is generally unfiltered (71.3%). One-third (33.6%) of the units had an independent water bottle reservoir. Flushing, a basic physical technique to improve the quality of units’ outflow water, was practiced in 65.4% of dental offices. Concerning the chemical treatment of water, it was used for 62.1% of the units. An analysis of the microbiological quality of the DUWL water was only carried out in 2.6% of the offices. In conclusion, providing better training to dental staff seems necessary to improve their practices and to generalize procedures that improve the microbiological quality of the water used.
- 1 November 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (21) , 4242
Open AccessDental Unit Waterlines: A Survey of Practices in Eastern France
Water is essential during dental care. Physical and chemical techniques should be used to maintain a good water quality with respect to bacteria, and to ensure the safety of exposed patients and dental staff. The aim of this survey was to assess the modalities used by dental practitioners in Eastern France to maintain the water quality of their dental unit waterlines (DUWLs). A questionnaire about water quality maintenance practices was sent to 870 dental offices in 2016. The questionnaires were completed by 153 dental offices, covering about 223 dental care units. The majority of units were fed by mains water (91.0%), which is generally unfiltered (71.3%). One-third (33.6%) of the units had an independent water bottle reservoir. Flushing, a basic physical technique to improve the quality of units’ outflow water, was practiced in 65.4% of dental offices. Concerning the chemical treatment of water, it was used for 62.1% of the units. An analysis of the microbiological quality of the DUWL water was only carried out in 2.6% of the offices. In conclusion, providing better training to dental staff seems necessary to improve their practices and to generalize procedures that improve the microbiological quality of the water used.
- 1 December 2017
- Published by Elsevier in Journal of Medical Mycology
- Vol. 27 (4) , 449-456
Quelles mesures pour maîtriser le risque infectieux chez les patients immunodéprimés ? Recommandations formalisées d’experts
- 1 December 2017
- Published by Elsevier in Journal of Medical Mycology
- Vol. 27 (4) , 449-456
Quelles mesures pour maîtriser le risque infectieux chez les patients immunodéprimés ? Recommandations formalisées d’experts