MLMartin Leinung

Martin Leinung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Martin Leinung has a total of 78 co-authors. Here are the top co-authors by number of shared publications:

  • Timo Stöver

    Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany

    5 shared publications
  • Timo Stöver

    Goethe-Universität Frankfurt am Main, HE, Germany

    4 shared publications
  • Andreas G. Loth

    Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany

    3 shared publications
  • Silke Helbig

    Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany

    3 shared publications
  • Iris Burck

    Institute of Diagnostic and Interventional Radiology, University Hospital, Frankfurt, Germany

    2 shared publications
  • Silke Helbig

    Department of Otorhinolaryngology, Head and Neck Surgery, Goethe University Frankfurt, University Hospital, Frankfurt, Germany

    2 shared publications

Latest Publications

  • Open Access

    Postoperative radiological assessment of the mastoid facial canal in cochlear implant patients in correlation with facial nerve stimulation

    by Iris Burck, Rania A. Helal, Nagy N. N. Naguib, Nour-Eldin A. Nour-Eldin, Jan-Erik Scholtz, Simon Martin, Martin Leinung, Silke Helbig, Timo Stöver, Annette Lehn, et al.

    Objectives: To correlate the radiological assessment of the mastoid facial canal in postoperative cochlear implant (CI) cone-beam CT (CBCT) and other possible contributing clinical or implant-related factors with postoperative facial nerve stimulation (FNS) occurrence. Methods: Two experienced radiologists evaluated retrospectively 215 postoperative post-CI CBCT examinations. The mastoid facial canal diameter, wall thickness, distance between the electrode cable and mastoid facial canal, and facial-chorda tympani angle were assessed. Additionally, the intracochlear position and the insertion angle and depth of electrodes were evaluated. Clinical data were analyzed for postoperative FNS within 1.5-year follow-up, CI type, onset, and causes for hearing loss such as otosclerosis, meningitis, and history of previous ear surgeries. Postoperative FNS was correlated with the measurements and clinical data using logistic regression. Results: Within the study population (mean age: 56 ± 18 years), ten patients presented with FNS. The correlations between FNS and facial canal diameter (p = 0.09), wall thickness (p = 0.27), distance to CI cable (p = 0.44), and angle with chorda tympani (p = 0.75) were statistically non-significant. There were statistical significances for previous history of meningitis/encephalitis (p = 0.001), extracochlear-electrode-contacts (p = 0.002), scala-vestibuli position (p = 0.02), younger patients’ age (p = 0.03), lateral-wall-electrode type (p = 0.04), and early/childhood onset hearing loss (p = 0.04). Histories of meningitis/encephalitis and extracochlear-electrode-contacts were included in the first two steps of the multivariate logistic regression. Conclusion: The mastoid-facial canal radiological assessment and the positional relationship with the CI electrode provide no predictor of postoperative FNS. Histories of meningitis/encephalitis and extracochlear-electrode-contacts are important risk factors. Key Points: • Post-operative radiological assessment of the mastoid facial canal and the positional relationship with the CI electrode provide no predictor of post-cochlear implant facial nerve stimulation. • Radiological detection of extracochlear electrode contacts and the previous clinical history of meningitis/encephalitis are two important risk factors for postoperative facial nerve stimulation in cochlear implant patients. • The presence of scala vestibuli electrode insertion as well as the lateral wall electrode type, the younger patient’s age, and early onset of SNHL can play important role in the prediction of post-cochlear implant facial nerve stimulation.


  • Open Access

    Auswirkungen der SARS-CoV‑2-Pandemie auf die universitäre Hals-Nasen-Ohren-Heilkunde im Bereich der Forschung, Lehre und Weiterbildung

    by T. Stöver, S. Dazert, S. K. Plontke, S. Kramer, P. Ambrosch, C. Arens, C. Betz, D. Beutner, C. Bohr, K.-L. Bruchhage, et al.

    Zusammenfassung: Hintergrund: Ab Frühjahr 2020 kam es zur weltweiten Verbreitung von SARS-CoV‑2 mit der heute als erste Welle der Pandemie bezeichneten Phase ab März 2020. Diese resultierte an vielen Kliniken in Umstrukturierungen und Ressourcenverschiebungen. Ziel unserer Arbeit war die Erfassung der Auswirkungen der Pandemie auf die universitäre Hals-Nasen-Ohren(HNO)-Heilkunde für die Forschung, Lehre und Weiterbildung. Material und Methoden: Die Direktorinnen und Direktoren der 39 Universitäts-HNO-Kliniken in Deutschland wurden mithilfe einer strukturierten Online-Befragung zu den Auswirkungen der Pandemie im Zeitraum von März bis April 2020 auf die Forschung, Lehre und die Weiterbildung befragt. Ergebnisse: Alle 39 Direktorinnen und Direktoren beteiligten sich an der Umfrage. Hiervon gaben 74,4 % (29/39) an, dass es zu einer Verschlechterung ihrer Forschungstätigkeit infolge der Pandemie gekommen sei. Von 61,5 % (24/39) wurde berichtet, dass pandemiebezogene Forschungsaspekte aufgegriffen wurden. Von allen Kliniken wurde eine Einschränkung der Präsenzlehre berichtet und 97,5 % (38/39) führten neue digitale Lehrformate ein. Im Beobachtungszeitraum sahen 74,4 % der Klinikdirektoren die Weiterbildung der Assistenten nicht gefährdet. Schlussfolgerung: Die Ergebnisse geben einen Einblick in die heterogenen Auswirkungen der Pandemie. Die kurzfristige Bearbeitung pandemiebezogener Forschungsthemen und die Einführung innovativer digitaler Konzepte für die studentische Lehre belegt eindrücklich das große innovative Potenzial und die schnelle Reaktionsfähigkeit der HNO-Universitätskliniken, um auch während der Pandemie ihre Aufgaben in der Forschung, Lehre und Weiterbildung bestmöglich zu erfüllen.


  • Comparison of bandaging techniques to prevent cochlear implant magnet displacement following MRI

    by Martin Leinung, Andreas G. Loth, Michaela Kroth, Iris Burck, Timo Stöver, Silke Helbig

    Introduction For cochlear implants (CI) with removable magnets, a pressure bandage usually is recommended during MR imaging to avoid magnet dislocation. Nevertheless, this complication is regularly observed despite applying a pressure bandage. The aim of this study was to compare various bandaging techniques to avoid magnet displacement. Materials and methods As an experimental model a force measuring stand was developed and validated, on which the process of magnet dislocation could be simulated on a cochlear implant. In a test series with six combinations of cohesive and elastic bandages with different counter pressure elements (CPE), the forces required to induce magnet dislocation against the resistance of a compression bandage was determined. In addition, the inter- and intraindividual variability of the compression bandages was measured for ten different users. Results The cohesive bandage had the lowest average holding force of 10.70 N. The elastic bandage developed more than four times the retention force of the cohesive bandage (44.88 N, p < 0.01). By adding a CPE, these values could be increased highly significantly up to factor 3. The optimum combination in terms of fixation force against magnet dislocation was an elastic bandage plus a cylindrical CPE (76.60 N). The data showed a high interindividual variability. Conclusion Even though most CI manufacturers now offer 3T-conditional implants, a pressure bandage will have to be applied to thousands of patients with previous implant generations to prevent magnet dislocation. We examined for the first time force measurements to compare different bandaging techniques by detecting the holding force of the CI magnet. We were able to identify an optimized combination of a bandage and a CPE to immobilize the CI magnet. However, our data also demonstrated a significant scatter amongst different examiners. Although our data provide valuable data for potential clinical application, future development of the dressing technique is required for human use


  • In vitro comparison of surgical techniques in times of the SARS-CoV-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling

    by Daniela B. Guderian, Andreas G. Loth, Roxanne Weiß, Marc Diensthuber, Timo Stöver, Martin Leinung

    Introduction Based on current knowledge, the SARS-CoV-2 is transmitted via droplet, aerosols and smear infection. Due to a confirmed high virus load in the upper respiratory tract of COVID-19 patients, there is a potential risk of infection for health care professionals when performing surgical procedures in this area. The aim of this study was the semi-quantitative comparison of ENT-typical interventions in the head and neck area with regard to particle and aerosol generation. These data can potentially contribute to a better risk assessment of aerogenic SARS-CoV-2-transmission caused by medical procedures. Materials and methods As a model, a test chamber was created to examine various typical surgical interventions on porcine soft and hard tissues. Simultaneously, particle and aerosol release were recorded and semi-quantitatively evaluated time-dependently. Five typical surgical intervention techniques (mechanical stress with a passive instrument with and without suction, CO2 laser treatment, drilling and bipolar electrocoagulation) were examined and compared regarding resulting particle release. Results Neither aerosols nor particles could be detected during mechanical manipulation with and without suction. The use of laser technique showed considerable formation of aerosol. During drilling, mainly solid tissue particles were scattered into the environment (18.2 ± 15.7 particles/cm2/min). The strongest particle release was determined during electrocoagulation (77.2 ± 30.4 particles/cm2/min). The difference in particle release between electrocoagulation and drilling was significant (p < 0.05), while particle diameter was comparable. In addition, relevant amounts of aerosol were released during electrocoagulation (79.6% of the maximum flue gas emission during laser treatment). Discussion Our results demonstrated clear differences comparing surgical model interventions. In contrast to sole mechanical stress with passive instruments, all active instruments (laser, drilling and electrocoagulation) released particles and aerosols. Assuming that particle and aerosol exposure is clinically correlated to the risk of SARS-CoV-2-transmission from the patient to the physician, a potential risk for health care professionals for infection cannot be excluded. Especially electrocautery is frequently used for emergency treatment, e.g., nose bleeding. The use of this technique may, therefore, be considered particularly critical in potentially infectious patients. Alternative methods may be given preference and personal protective equipment should be used consequently.


  • Open Access

    Low-cost CI-Elektroden- und Cochleadummies für minimal-invasive Insertionsübungen

    by M Leinung, Ag Loth, M Gröger, R Weiß, T Stöver

    Einleitung Bei der Versorgung mit einem Cochlea-Implantat (CI) ist die Einführung der Elektrode in die Hörschnecke ein kritischer mikrochirurgischer Schritt. Dieser kann allerdings nicht annähernd so oft geübt werden, wie es für ein sicheres motorisches Lernen erforderlich wäre, da die benötigten Materialien teuer und nur limitiert verfügbar sind. Daher sollten ein Elektrodendummy und ein darauf abgestimmtes Cochleamodell gefertigt werden, die einen realitätsnahen Insertionsprozess ermöglichen. Material und Methoden Für das Elektrodendesign wurden ausschließlich kommerziell verfügbare Einwegmaterialien verwendet. Das Cochleamodell wurde aus einem gefärbtem Epoxidblock gefräst. Mit diesen Komponenten wurden wiederholte automatische Insertionen mit konstanter Vorschubgeschwindigkeit in je 10 Iterationen durchgeführt und die dabei auftretenden Insertionskräfte mithilfe eines Kraftsensors gemessen. Ergebnis: Es konnte eine Testelektrode entwickelt werden, die im Gegensatz zu echten Elektrodendummies kaum Verschleiß bei mehrfacher Anwendung zeigt und in der Herstellung extrem günstig (< 5ct) ist. Die Konfiguration der Scala tympani in dem Cochleamodell wurde in mehreren Iterationen angepasst, bis der resultierende Kraftverlauf dem Insertionsvorgang einer FLEX28-Elektrode (MED-EL) entsprach. Die Insertionstiefe wurde aus dem Videobild mit einer Genauigkeit < 0,1mm ermittelt. Schlußfolgerung Das Entwicklungsergebnis dieser Studie ist ein haptischer Simulator, der nur in der Kombination aus Elektrodendummy und Modellcochlea funktioniert und tiefenabhängig die Insertionskräfte realistisch wiedergibt. Hierdurch kann der Anwender Insertionsversuche mit vielen Wiederholungen durchführen, um die Technik der hörerhaltenden, minimal-invasiven Cochlea-Implantation zu erlernen. Publication Date: 10 June 2020 (online) © . © Georg Thieme Verlag KG Stuttgart · New York

  • Cochlear implant magnet dislocation after MRI: surgical management and outcome

    by Martin Leinung, Andreas Loth, Maximilian Gröger, Iris Burck, Thomas Vogl, Timo Stöver, Silke Helbig

    An increasing number of cochlear implant (CI) users is examined by magnetic resonance imaging which may cause the displacement of the implant magnet. This complication prevents the usage of the external processor and has to be treated surgically in most cases. The purpose of this study is to analyze the results of the surgical intervention and the consequences for the CI recipients.


  • Evaluation of a bone groove geometry for fixation of a cochlear implant electrode

    by Andreas German Loth, Youssef Adel, Roxanne Weiß, Silke Helbig, Timo Stöver, Martin Leinung

    Purpose Electrode migration is a rare, but relevant complication in cochlear implant (CI) surgery. An effective countermeasure is to create a bone groove in the facial recess to secure the electrode lead. We use this method routinely since 2013, but still experienced sporadic electrode migration events most likely due to an improper surgical execution. The aim of this study was to determine the optimum groove geometry. Methods Grooves of defined geometry were created in specimens of fresh porcine femur compacta by use of a CNC milling machine. Electrode dummies were fixed in the groove and then exposed to tensile stress. Force measurements were carried out to examine the effect of groove diameter and opening width on the holding force. The mechanical impact on the electrode cable during insertion into the groove was recorded and the electrode lead was examined under microscopic magnification to assess potential structural damage. Results Optimum groove geometry (diameter 1.10 mm, opening width 0.90 mm) ensured an average holding force of 830 mN which is equivalent to the established fixation by use of a titanium clip. None of the microscopic inspections revealed any morphological deterioration of the electrode lead. Conclusion The fixation of a CI electrode in a bone groove in the facial recess appears to be effective and safe. Furthermore, this method does not require additional costs or foreign material. The optimum geometry defined in this study helped us to refine our surgical standard produce and to generate more consistent results.


  • The Effect of a Bone Groove Against Cochlear Implant Electrode Migration

    by Martin Leinung, Silke Helbig, Youssef Adel, Timo Stöver, Andreas G. Loth

    Hypothesis: The risk of electrode migration in cochlear implant (CI) surgery can be reduced by securing the electrode lead in a bone groove in the chorda-facial angle. Background: Electrode migration is an important complication in CI surgery, which affects hearing performance, may induce pain and facial nerve stimulation, and requires surgical revision. A potential method to secure the electrode is to use a bone groove created in the facial recess to fixate the electrode lead. This surgical measure is a standard procedure for lateral wall electrodes (LWE) in our clinic since 2013. Methods: Retrospective analysis of consecutive CI cases of a tertiary referral center from 2006 to 2016 and comparison of incidence rates between group A (without bone groove, years 2006-2012) and group B (with bone groove fixation, years 2013-2016). Clinical cases were reviewed with respect to electrode type, migration length, time interval to migration, and findings during revision surgery. Results: Seventeen cases of electrode migration were found in a total of 1,603 cochlear implantations. Only LWE designs were affected by migration. The cumulative incidence for LWE in group B (0.5%) was significantly lower than in group A (3.7%, p < 0.01). The two migration cases in group B revealed insufficient geometric design of the bone grooves. Only one patient experienced a remigration after revision surgery. Conclusion: The fixation in a bone groove in the chordafacial angle is an effective measure against migration of LWE. Proper surgical execution is mandatory to ensure a tight and enduring fit.


  • Sekretbeurteilungsskala nach Murray et al. für FEES®

    by P. Pluschinski, Y. Zaretsky, A. Almahameed, J.-C. Koseki, M. Leinung, L. Girth, J. Wagenblast, R. Sader, T. Stöver, C. Hey

    Sekretansammlungen im Hypopharynx, Aditus laryngis und Trachea bilden eines der Kardinalmerkmale einer oropharyngealen Schluckstörung. Zur Einschätzung des Schweregrades wird international die 4-Punkte-Sekretbeurteilungsskala nach Murray et al. eingesetzt, existierend in einer Lang- und einer Kurzversion.


  • Die Bonebridge – das erste aktive Knochenleitungsimplantat

    by Martin Leinung, Tobias Rader, Timo Stöver

    Knochenleitungshörgeräte regen das Innenohr über Körperschall an, der auf unterschiedliche Arten auf den Schädelknochen übertragen werden kann. Die beste Ankopplung erhält man, wenn das Hörsystem fest mit dem Knochen verbunden wird. In der Praxis bedeutete dies bislang, dass die Patienten dauerhaft eine die Haut penetrierende und somit ständig sichtbare Titanschraube hinter dem Ohr trugen. Hierdurch besteht das Risiko einer Infektion, die schlimmstenfalls zum Verlust des Implantats führen könnte. Seit letztem Jahr ist nun erstmalig ein teilimplantierbares Knochenleitungsgerät verfügbar, das diese Nachteile umgeht. Bone conduction hearing aids stimulate the inner ear via the impact of sound waves, which can be transmitted to the cranial bone by various ways. The optimum coupling is achieved when the hearing device is tightly fixed to the bone. Therefore, the patients are equipped with a skin-penetrating and permanently visible screw behind the auricle. The patients thus bear an inherent risk of wound infection up to implant loss. In 2012 the first implantable bone conduction implant became available, which now avoids these drawbacks.