Bin Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bin Tang has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Wei Yin
Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang, China
3 shared publicationsChao Cao
Institute of Nuclear Physics and Chemistry, CAEP, Mianyang of Sichuan Prov., 621900, China
2 shared publicationsHang Li
Institute of Nuclear Physics and Chemistry, CAEP, Mianyang of Sichuan Prov., 621900, China
2 shared publicationsHeyong Huo
Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang, China
2 shared publicationsSheng Wang
Institute of Nuclear Physics and Chemistry, CAEP, Mianyang of Sichuan Prov., 621900, China
2 shared publicationsYang Wu
Institute of Nuclear Physics and Chemistry, CAEP, Mianyang of Sichuan Prov., 621900, China
2 shared publications
Latest Publications
- Open Access
A Novel NDT Scanning System Based on Line Array Fast Neutron Detector and D-T Neutron Source
A novel non-destructive testing scanning system based on a large-size line array fast neutron detector and compact D-T neutron source has been constructed. The scanning range is up to 1000 mm, and the resolution is better than 1 mm. The fast neutron detection subsystem consists of a polypropylene zinc sulfide scintillator embedded with wavelength-shifting fibers, coupled with a light lens and a scientific CCD camera. With a new rotating tritium target, the lifetime of the compact D-T neutron source could achieve ten hours. The experimental results indicate that the scanning method based on line array fast neutron detector and D-T neutron source is feasible and enables the detection of slits on the order of 0.5 mm in width. Fast neutron tomography has been realized by this detection system too.
Open AccessA Novel NDT Scanning System Based on Line Array Fast Neutron Detector and D-T Neutron Source
A novel non-destructive testing scanning system based on a large-size line array fast neutron detector and compact D-T neutron source has been constructed. The scanning range is up to 1000 mm, and the resolution is better than 1 mm. The fast neutron detection subsystem consists of a polypropylene zinc sulfide scintillator embedded with wavelength-shifting fibers, coupled with a light lens and a scientific CCD camera. With a new rotating tritium target, the lifetime of the compact D-T neutron source could achieve ten hours. The experimental results indicate that the scanning method based on line array fast neutron detector and D-T neutron source is feasible and enables the detection of slits on the order of 0.5 mm in width. Fast neutron tomography has been realized by this detection system too.
- 1 March 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 169, 109564
A moveable neutron imaging facility using D-T neutron source based on a compact accelerator
- 1 March 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 169, 109564
A moveable neutron imaging facility using D-T neutron source based on a compact accelerator
- 1 February 2021
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 603
An improved reconstruction method for polarimetric neutron tomography
- 1 February 2021
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 603
An improved reconstruction method for polarimetric neutron tomography