Adam Bayliss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Adam Bayliss has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Ahtesham Ullah Khan
Department of Medical Physics, School of Medicine and Public Health University of Wisconsin‐Madison Madison Wisconsin USA
1 shared publication - Andrew M. Baschnagel
University of Wisconsin Carbone Cancer Center, Madison, WI
1 shared publication - Andrzej P. Wojcieszynski
Department of Radiation Oncology, University of Pennsylvania, Philadelphia, USA
1 shared publication - Bhudatt R. Paliwal
Department of Human Oncology, University of Wisconsin - Madison, Madison, USA
1 shared publication Brett Morris
Department of Human Oncology, School of Medicine and Public Health University of Wisconsin‐Madison Madison Wisconsin USA
1 shared publicationCarri Glide‐Hurst
Department of Medical Physics, School of Medicine and Public Health University of Wisconsin‐Madison Madison Wisconsin USA
1 shared publication
Latest Publications
- Open Access
- 30 November 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (1) , e14229
Dose‐rate dependence and IMRT QA suitability of EBT3 radiochromic films for pulse reduced dose‐rate radiotherapy (PRDR) dosimetry
Background: Pulsed reduced dose rate (PRDR) is an emerging radiotherapy technique for recurrent diseases. It is pertinent that the linac beam characteristics are evaluated for PRDR dose rates and a suitable dosimeter is employed for IMRT QA.Purpose: This study sought to investigate the pulse characteristics of a 6 MV photon beam during PRDR irradiations on a commercial linac. The feasibility of using EBT3 radiochromic film for use in IMRT QA was also investigated by comparing its response to a commercial diode array phantom.Methods: A plastic scintillator detector was employed to measure the photon pulse characteristics across nominal repetition rates (NRRs) in the 5–600 MU/min range. Film was irradiated with dose rates in the 0.033–4 Gy/min range to study the dose rate dependence. Five clinical PRDR treatment plans were selected for IMRT QA with the Delta4 phantom and EBT3 film sheets. The planned and measured dose were compared using gamma analysis with a criterion of 3%/3 mm. EBT3 film QA was performed using a cumulative technique and a weighting factor technique.Results: Negligible differences were observed in the pulse width and height data between the investigated NRRs. The pulse width was measured to be 3.15 ± 0.01 and the PRF was calculated to be 3–357 Hz for the 5–600 MU/min NRRs. The EBT3 film was found to be dose rate independent within 3%. The gamma pass rates (GPRs) were above 99% and 90% for the Delta4 phantom and the EBT3 film using the cumulative QA method, respectively. GPRs as low as 80% were noted for the weighting factor EBT3 QA method.Conclusions: Altering the NRRs changes the mean dose rate while the instantaneous dose rate remains constant. The EBT3 film was found to be suitable for PRDR dosimetry and IMRT QA with minimal dose rate dependence.
- 30 November 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (1) , e14229
Open AccessDose‐rate dependence and IMRT QA suitability of EBT3 radiochromic films for pulse reduced dose‐rate radiotherapy (PRDR) dosimetry
Background: Pulsed reduced dose rate (PRDR) is an emerging radiotherapy technique for recurrent diseases. It is pertinent that the linac beam characteristics are evaluated for PRDR dose rates and a suitable dosimeter is employed for IMRT QA.Purpose: This study sought to investigate the pulse characteristics of a 6 MV photon beam during PRDR irradiations on a commercial linac. The feasibility of using EBT3 radiochromic film for use in IMRT QA was also investigated by comparing its response to a commercial diode array phantom.Methods: A plastic scintillator detector was employed to measure the photon pulse characteristics across nominal repetition rates (NRRs) in the 5–600 MU/min range. Film was irradiated with dose rates in the 0.033–4 Gy/min range to study the dose rate dependence. Five clinical PRDR treatment plans were selected for IMRT QA with the Delta4 phantom and EBT3 film sheets. The planned and measured dose were compared using gamma analysis with a criterion of 3%/3 mm. EBT3 film QA was performed using a cumulative technique and a weighting factor technique.Results: Negligible differences were observed in the pulse width and height data between the investigated NRRs. The pulse width was measured to be 3.15 ± 0.01 and the PRF was calculated to be 3–357 Hz for the 5–600 MU/min NRRs. The EBT3 film was found to be dose rate independent within 3%. The gamma pass rates (GPRs) were above 99% and 90% for the Delta4 phantom and the EBT3 film using the cumulative QA method, respectively. GPRs as low as 80% were noted for the weighting factor EBT3 QA method.Conclusions: Altering the NRRs changes the mean dose rate while the instantaneous dose rate remains constant. The EBT3 film was found to be suitable for PRDR dosimetry and IMRT QA with minimal dose rate dependence.
- Open Access
- 4 April 2018
- Published by Springer Nature in Cureus
- Vol. 10 (4) , e2422
A New Era of Image Guidance with Magnetic Resonance-guided Radiation Therapy for Abdominal and Thoracic Malignancies
Magnetic resonance-guided radiation therapy (MRgRT) offers advantages for image guidance for radiotherapy treatments as compared to conventional computed tomography (CT)-based modalities. The superior soft tissue contrast of magnetic resonance (MR) enables an improved visualization of the gross tumor and adjacent normal tissues in the treatment of abdominal and thoracic malignancies. Online adaptive capabilities, coupled with advanced motion management of real-time tracking of the tumor, directly allow for high-precision inter-/intrafraction localization. The primary aim of this case series is to describe MR-based interventions for localizing targets not well-visualized with conventional image-guided technologies. The abdominal and thoracic sites of the lung, kidney, liver, and gastric targets are described to illustrate the technological advancement of MR-guidance in radiotherapy.
- 4 April 2018
- Published by Springer Nature in Cureus
- Vol. 10 (4) , e2422
Open AccessA New Era of Image Guidance with Magnetic Resonance-guided Radiation Therapy for Abdominal and Thoracic Malignancies
Magnetic resonance-guided radiation therapy (MRgRT) offers advantages for image guidance for radiotherapy treatments as compared to conventional computed tomography (CT)-based modalities. The superior soft tissue contrast of magnetic resonance (MR) enables an improved visualization of the gross tumor and adjacent normal tissues in the treatment of abdominal and thoracic malignancies. Online adaptive capabilities, coupled with advanced motion management of real-time tracking of the tumor, directly allow for high-precision inter-/intrafraction localization. The primary aim of this case series is to describe MR-based interventions for localizing targets not well-visualized with conventional image-guided technologies. The abdominal and thoracic sites of the lung, kidney, liver, and gastric targets are described to illustrate the technological advancement of MR-guidance in radiotherapy.