Yi Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yi Cao has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jingshi Dong
School of Mechanical and Aerospace Engineering, Jilin University, Changchun 130022, China
2 shared publications - Bowen Zhang
Jilin University, Changchun, 130012, China
1 shared publication - Jiru Wang
School of Mechanical and Aerospace Engineering, Jilin University, Changchun, China
1 shared publication Quanqu Chen
Jilin University, Changchun, China
1 shared publicationRui Gang Liu
Jilin University, Changchun, China
1 shared publicationWeishuai Liu
Jilin University, Changchun, China
1 shared publication
Latest Publications
- 12 August 2021
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 30 (9) , 095015
A stick-slip piezoelectric actuator with suppressed backward motion achieved using an active locking mechanism (ALM)
Backward motion commonly exists in the stick-slip linear piezoelectric actuator, resulting in deterioration of the output performance and limiting their applications. To solve the problem, a stick-slip linear piezoelectric actuator with suppressed backward motion, achieved using an active-locking mechanism (ALM) with two mechanisms, is proposed in this paper. One mechanism involves stick-slip driving, while the other actively suppresses backward motion by clamping the slider during the backward driving process through efficient control. A prototype actuator was designed and manufactured to verify the feasibility of this method, and an experimental system was established to obtain the detailed parameters. Also, to verify the feasibility and effectiveness of the suppression effect on backward motion of the proposed actuator, the output performance of the traditional stick-slip actuator and the actuator with the ALM were compared. Based on the results, we demonstrate that the maximum output speed and maximum output force of the prototype are 2.26 mm s −1 and 1.6 N under a voltage of 100 V, respectively.
- 12 August 2021
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 30 (9) , 095015
A stick-slip piezoelectric actuator with suppressed backward motion achieved using an active locking mechanism (ALM)
Backward motion commonly exists in the stick-slip linear piezoelectric actuator, resulting in deterioration of the output performance and limiting their applications. To solve the problem, a stick-slip linear piezoelectric actuator with suppressed backward motion, achieved using an active-locking mechanism (ALM) with two mechanisms, is proposed in this paper. One mechanism involves stick-slip driving, while the other actively suppresses backward motion by clamping the slider during the backward driving process through efficient control. A prototype actuator was designed and manufactured to verify the feasibility of this method, and an experimental system was established to obtain the detailed parameters. Also, to verify the feasibility and effectiveness of the suppression effect on backward motion of the proposed actuator, the output performance of the traditional stick-slip actuator and the actuator with the ALM were compared. Based on the results, we demonstrate that the maximum output speed and maximum output force of the prototype are 2.26 mm s −1 and 1.6 N under a voltage of 100 V, respectively.
- 7 November 2019
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 31 (1) , 117-126
Performance of single piezoelectric vibrator micropump with check valve
A new single vibrator piezoelectric micropump which integrated the check valve and the piezoelectric oscillator is designed in this research. The micropump mainly consists of a circular piezoelectric vibrator, a polyethylene terephthalate check valve, two rubber sealing rings, upper pump cover, and lower pump cover. In this research, in order to study output performance of the single vibrator piezoelectric pump, theoretical analysis and experimental verification of the piezoelectric pump check valve have been carried out by exploiting the method of check valves and vibrator mass separation. Experimental results show that the opening of the check valve is mainly caused by the pressure difference and the inertia force. The dominant factor of check valve opening is different under different drive frequencies. A maximum opening displacement of 19.625 μm of the check valve is obtained when the micropump is driven by a sinusoidal voltage of 60 V at 300 Hz. In addition, the maximum flow rate of 2034.7 mL min−1 is obtained when the micropump is driven by a sinusoidal voltage of 60 V at 320 Hz, and a maximum output pressure of 0.82 kPa is obtained when the micropump is driven by a sinusoidal voltage of 60 V at 140 Hz.
- 7 November 2019
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 31 (1) , 117-126
Performance of single piezoelectric vibrator micropump with check valve
A new single vibrator piezoelectric micropump which integrated the check valve and the piezoelectric oscillator is designed in this research. The micropump mainly consists of a circular piezoelectric vibrator, a polyethylene terephthalate check valve, two rubber sealing rings, upper pump cover, and lower pump cover. In this research, in order to study output performance of the single vibrator piezoelectric pump, theoretical analysis and experimental verification of the piezoelectric pump check valve have been carried out by exploiting the method of check valves and vibrator mass separation. Experimental results show that the opening of the check valve is mainly caused by the pressure difference and the inertia force. The dominant factor of check valve opening is different under different drive frequencies. A maximum opening displacement of 19.625 μm of the check valve is obtained when the micropump is driven by a sinusoidal voltage of 60 V at 300 Hz. In addition, the maximum flow rate of 2034.7 mL min−1 is obtained when the micropump is driven by a sinusoidal voltage of 60 V at 320 Hz, and a maximum output pressure of 0.82 kPa is obtained when the micropump is driven by a sinusoidal voltage of 60 V at 140 Hz.