Roman Korab
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Roman Korab has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Marcin Połomski
Department of Algorithmics and Software, Faculty of Automatic Control, Electronics and Computer Science, Silesian University of Technology, 44-100 Gliwice, Poland
6 shared publications - Tomasz Naczyński
Joint Doctoral School, Silesian University of Technology, 44-100 Gliwice, Poland
4 shared publications - Wojciech Jaworski
Interdisciplinary Division for Energy Analyses, National Centre for Nuclear Research, 02-724 Warsaw, Poland
4 shared publications - Endika Urresti Padrón
Interdisciplinary Division for Energy Analyses, National Centre for Nuclear Research, 02-724 Warsaw, Poland
3 shared publications Karol Wawrzyniak
3 shared publications- Marcin Smołka
Politech Slaska, Wspolna Szkola Doktorow, Ul Akad 2a, PL-44100 Gliwice, Poland
3 shared publications
Latest Publications
- 8 February 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 353
Impact of distributed battery energy storage controlled by optimization-based home energy management systems implementing various objective functions on the voltage profiles in the low-voltage network with a high saturation of prosumer photovoltaic micro-installations
- 8 February 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 353
Impact of distributed battery energy storage controlled by optimization-based home energy management systems implementing various objective functions on the voltage profiles in the low-voltage network with a high saturation of prosumer photovoltaic micro-installations
- Open Access
Optimal Scheduling of Energy Storage and Shiftable Loads in Grid-Connected Residential Buildings with Photovoltaic Micro-Installations
Photovoltaic (PV) systems are becoming increasingly popular, especially in residential buildings. However, the high penetration of prosumer PV micro-installations can have a negative impact on the operation of distribution networks due to the low self-consumption of the energy produced. One way to mitigate this problem is to use a residential energy storage system (RESS) and load shifting under a demand-side management (DSM) scheme. Energy management systems (EMSs) are used to control the operation of RESSs and to implement DSM. There are two main categories of EMSs: rule-based and optimization-based. Optimization-based EMSs provide better results than rule-based EMSs but can be computationally expensive. This article proposes an optimization-based EMS that is designed specifically for residential buildings. The proposed home energy management system (HEMS) uses a particle swarm optimization method to maximize the prosumer’s financial neutrality, which is calculated based on dynamic energy prices. Simulation-based evaluation using the measurements taken in a building equipped with a PV source, RESS, and shiftable loads shows the improved performance of the proposed HEMS compared to rule-based RESS control. The results show that the designed HEMS increases self-consumption, thus reducing the impact of the prosumer’s PV micro-installations on the distribution grid.
Open AccessOptimal Scheduling of Energy Storage and Shiftable Loads in Grid-Connected Residential Buildings with Photovoltaic Micro-Installations
Photovoltaic (PV) systems are becoming increasingly popular, especially in residential buildings. However, the high penetration of prosumer PV micro-installations can have a negative impact on the operation of distribution networks due to the low self-consumption of the energy produced. One way to mitigate this problem is to use a residential energy storage system (RESS) and load shifting under a demand-side management (DSM) scheme. Energy management systems (EMSs) are used to control the operation of RESSs and to implement DSM. There are two main categories of EMSs: rule-based and optimization-based. Optimization-based EMSs provide better results than rule-based EMSs but can be computationally expensive. This article proposes an optimization-based EMS that is designed specifically for residential buildings. The proposed home energy management system (HEMS) uses a particle swarm optimization method to maximize the prosumer’s financial neutrality, which is calculated based on dynamic energy prices. Simulation-based evaluation using the measurements taken in a building equipped with a PV source, RESS, and shiftable loads shows the improved performance of the proposed HEMS compared to rule-based RESS control. The results show that the designed HEMS increases self-consumption, thus reducing the impact of the prosumer’s PV micro-installations on the distribution grid.
- 3 October 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (10) , 3-8
Minimalizacja wpływu prosumenckich mikroinstalacji fotowoltaicznych na pracę sieci niskiego napięcia
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informujące swoich czytelników o najnowszych osiągnięciach naukowych i nowoczesnych rozwiązaniach technicznych w Polsce i na świecie, popularyzuje problemy techniczne oraz poszerza wiedzę i kulturę techniczną.
- 3 October 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (10) , 3-8
Minimalizacja wpływu prosumenckich mikroinstalacji fotowoltaicznych na pracę sieci niskiego napięcia
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informujące swoich czytelników o najnowszych osiągnięciach naukowych i nowoczesnych rozwiązaniach technicznych w Polsce i na świecie, popularyzuje problemy techniczne oraz poszerza wiedzę i kulturę techniczną.
- 28 January 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (1) , 314-319
Wpływ prosumenckich instalacji fotowoltaicznych na pracę sieci rozdzielczej niskiego napięcia
W artykule przedstawiono wpływ prosumenckich instalacji fotowoltaicznych na pracę sieci rozdzielczej niskiego napięcia. Symulacje pracy sieci zostały przeprowadzone w programie OpenDSS, z wykorzystaniem modelu sieci testowej CIGRE. Na podstawie uzyskanych wyników określono wpływ warunków atmosferycznych na ryzyko przekroczenia normalnych warunków pracy sieci. Ponadto określony został maksymalny stopień nasycenia sieci CIGRE źródłami PV, który nie powodował zaburzeń w pracy tej sieci
- 28 January 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (1) , 314-319
Wpływ prosumenckich instalacji fotowoltaicznych na pracę sieci rozdzielczej niskiego napięcia
W artykule przedstawiono wpływ prosumenckich instalacji fotowoltaicznych na pracę sieci rozdzielczej niskiego napięcia. Symulacje pracy sieci zostały przeprowadzone w programie OpenDSS, z wykorzystaniem modelu sieci testowej CIGRE. Na podstawie uzyskanych wyników określono wpływ warunków atmosferycznych na ryzyko przekroczenia normalnych warunków pracy sieci. Ponadto określony został maksymalny stopień nasycenia sieci CIGRE źródłami PV, który nie powodował zaburzeń w pracy tej sieci
- 28 September 2023
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (9) , 33-38
Short-term forecasting of photovoltaic power generation
In this article, a method for short-term forecasting of photovoltaic (PV) generation was proposed. The proposed method belongs to the group of physical methods and is based on numerical weather forecasts. The generation forecast was determined using the PV source model in the OpenDSS software. The results of calculations were compared with the results of measurements from the operating PV micro-installations
- 28 September 2023
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (9) , 33-38
Short-term forecasting of photovoltaic power generation
In this article, a method for short-term forecasting of photovoltaic (PV) generation was proposed. The proposed method belongs to the group of physical methods and is based on numerical weather forecasts. The generation forecast was determined using the PV source model in the OpenDSS software. The results of calculations were compared with the results of measurements from the operating PV micro-installations
- 14 February 2023
- Published by Elsevier in Energy Conversion and Management
- Vol. 280
A dynamic thermal model for a photovoltaic module under varying atmospheric conditions
- 14 February 2023
- Published by Elsevier in Energy Conversion and Management
- Vol. 280
A dynamic thermal model for a photovoltaic module under varying atmospheric conditions
- Open Access
Evaluating the Risk of Exceeding the Normal Operating Conditions of a Low-Voltage Distribution Network due to Photovoltaic Generation
Connecting photovoltaic micro-installations to a low-voltage network changes the operating conditions of the network. As a result, in certain situations, the permissible operating limits may be periodically exceeded. The risk of exceeding the normal operating conditions of the network depends on multiple factors, including the installed capacity of the photovoltaic sources. In this article, we use a time-series method to determine the annual risks of exceeding the bus voltage limits, the rated current of the lines and transformer, and the acceptable limit of the negative sequence component of bus voltage, as well as the risk of a reverse flow occurring, and the risk of energy losses increasing. We calculate these risks for different levels of penetration of the photovoltaic sources, different divisions of the rated power of the photovoltaic sources between individual phases, and different consumer load profiles. We perform calculations on a CIGRE test network using OpenDSS and statistical meteorological data for the Katowice (Poland) weather station. The results obtained indicate that connecting photovoltaic micro-installations to a low-voltage network has the greatest impact on the risk of reverse flow occurring and the risk of energy losses increasing. In addition, the risk of overvoltage and branch overload increases substantially. The method we present allows one to determine the value of the hosting capacity of a given low-voltage network, ensuring that the assumed risk of exceeding the normal operating conditions of the network is retained.
Open AccessEvaluating the Risk of Exceeding the Normal Operating Conditions of a Low-Voltage Distribution Network due to Photovoltaic Generation
Connecting photovoltaic micro-installations to a low-voltage network changes the operating conditions of the network. As a result, in certain situations, the permissible operating limits may be periodically exceeded. The risk of exceeding the normal operating conditions of the network depends on multiple factors, including the installed capacity of the photovoltaic sources. In this article, we use a time-series method to determine the annual risks of exceeding the bus voltage limits, the rated current of the lines and transformer, and the acceptable limit of the negative sequence component of bus voltage, as well as the risk of a reverse flow occurring, and the risk of energy losses increasing. We calculate these risks for different levels of penetration of the photovoltaic sources, different divisions of the rated power of the photovoltaic sources between individual phases, and different consumer load profiles. We perform calculations on a CIGRE test network using OpenDSS and statistical meteorological data for the Katowice (Poland) weather station. The results obtained indicate that connecting photovoltaic micro-installations to a low-voltage network has the greatest impact on the risk of reverse flow occurring and the risk of energy losses increasing. In addition, the risk of overvoltage and branch overload increases substantially. The method we present allows one to determine the value of the hosting capacity of a given low-voltage network, ensuring that the assumed risk of exceeding the normal operating conditions of the network is retained.
- 2 November 2021
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (11) , 205-208
Możliwości kształtowania bilansu energii elektrycznej odbiorcy indywidualnego wyposażonego w źródło fotowoltaiczne
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informujące swoich czytelników o najnowszych osiągnięciach naukowych i nowoczesnych rozwiązaniach technicznych w Polsce i na świecie, popularyzuje problemy techniczne oraz poszerza wiedzę i kulturę techniczną.
- 2 November 2021
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (11) , 205-208
Możliwości kształtowania bilansu energii elektrycznej odbiorcy indywidualnego wyposażonego w źródło fotowoltaiczne
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informujące swoich czytelników o najnowszych osiągnięciach naukowych i nowoczesnych rozwiązaniach technicznych w Polsce i na świecie, popularyzuje problemy techniczne oraz poszerza wiedzę i kulturę techniczną.
- Open Access
Fixed Transmission Charges Based on the Degree of Network Utilization
The core objective of transmission tariffs is the recovery of costs related to the transport of electricity. A usual component of a tariff is a fixed charge that covers the costs of the network infrastructure. As many customers use the power grid, the rate of this charge should reflect, as closely as possible, the actual costs of supplying energy to the individual consumers. These costs result from which network elements have been used in delivering the electricity, and to what extent these elements have been used. Therefore, the fixed transmission rates should depend on the degree of network utilization. This article investigates definitions of the degree of network utilization based on the active power flow. To calculate the degree of network utilization, the flow of electricity on a branch must be decomposed into the streams flowing to individual customers. For this decomposition, two methods are examined: a power flow tracing method, based on the proportional sharing principle, and an incremental power flow method, based on the superposition principle. The analyzed methodology is applied to a small test system for conceptual discussions, as well as to the transmission network of the Polish power system, as an example of practical application. The results of this study were then compared with the commonly used “postage stamp” method. Finally, several practical aspects related to the potential implementation of the presented methodology are discussed.
Open AccessFixed Transmission Charges Based on the Degree of Network Utilization
The core objective of transmission tariffs is the recovery of costs related to the transport of electricity. A usual component of a tariff is a fixed charge that covers the costs of the network infrastructure. As many customers use the power grid, the rate of this charge should reflect, as closely as possible, the actual costs of supplying energy to the individual consumers. These costs result from which network elements have been used in delivering the electricity, and to what extent these elements have been used. Therefore, the fixed transmission rates should depend on the degree of network utilization. This article investigates definitions of the degree of network utilization based on the active power flow. To calculate the degree of network utilization, the flow of electricity on a branch must be decomposed into the streams flowing to individual customers. For this decomposition, two methods are examined: a power flow tracing method, based on the proportional sharing principle, and an incremental power flow method, based on the superposition principle. The analyzed methodology is applied to a small test system for conceptual discussions, as well as to the transmission network of the Polish power system, as an example of practical application. The results of this study were then compared with the commonly used “postage stamp” method. Finally, several practical aspects related to the potential implementation of the presented methodology are discussed.
- Open Access
Risk-Based Active Power Redispatch Optimization
Risk-based redispatch optimization is proposed as a methodology to support the Transmission System Operator (TSO) with preventive remedial actions obtained by extending the security-constrained unit commitment/economic dispatch with constraints resulting from the risk assessed for the power system. Although being heuristic, the methodology is based on comprehensive dynamic security assessment as time-domain simulations are used, allowing to express the degree of all types of instabilities, e.g., caused by contingencies, in monetary terms. Therefore, the risk is assessed as the expected value of the cost incurred by the TSO. Such an approach forms a new pathway to including risk in planning procedures already used by TSOs. Results obtained for the IEEE39 dynamic power system, with costs assigned to load shedding and generator tripping due to single transmission lines short-circuits, are shown as a reference case.
Open AccessRisk-Based Active Power Redispatch Optimization
Risk-based redispatch optimization is proposed as a methodology to support the Transmission System Operator (TSO) with preventive remedial actions obtained by extending the security-constrained unit commitment/economic dispatch with constraints resulting from the risk assessed for the power system. Although being heuristic, the methodology is based on comprehensive dynamic security assessment as time-domain simulations are used, allowing to express the degree of all types of instabilities, e.g., caused by contingencies, in monetary terms. Therefore, the risk is assessed as the expected value of the cost incurred by the TSO. Such an approach forms a new pathway to including risk in planning procedures already used by TSOs. Results obtained for the IEEE39 dynamic power system, with costs assigned to load shedding and generator tripping due to single transmission lines short-circuits, are shown as a reference case.