MAMihrigül Ekşi Altan

Mihrigül Ekşi Altan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mihrigül Ekşi Altan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thermomechanical Tailoring of a DLP-Printable Shape Memory Polyurethane for Vascular Graft Applications

    by Ozan Azğüler, Mihrigül Ekşi Altan

    The increasing prevalence of cardiovascular diseases highlights the need to develop vascular grafts that match the mechanics of native vascular tissue and offer functional adaptability. This study reports the development and systematic optimization of a shape-memory polyurethane acrylate (PUA)-based photocurable resin for digital light processing (DLP)-based four-dimensional printing (4DP) applications. Resin formulations were designed by controlling hard/soft segment ratios, reactive diluent content, and crosslink density to position the glass transition temperature (Tg) within the physiological range (25–40 °C). Thermomechanical characterization was performed via dynamic mechanical analysis (DMA) and tensile testing, while a full-factorial Design of Experiments (DoE) approach was applied to optimize DLP process parameters—namely layer thickness, exposure time, and post-curing time. The developed resin formulation yielded a Tg of 38 °C as determined by DMA. Following process optimization, regression models showed high statistical fit (R2 > 99%), and experimental validation under optimal conditions (layer thickness: 82.83 µm, exposure time: 11 s, post-curing: 2 min) resulted in an elongation at break of 64.0 ± 3.4%, a Young’s modulus of 10.9 ± 0.1 MPa, and a tensile strength of 6.2 ± 0.3 MPa. The optimized system exhibited thermally triggerable shape memory behavior at near-body temperature, with mechanical properties consistent with natural arterial tissue benchmarks. These findings demonstrate a promising material design strategy for DLP-based 4D-printed vascular structures.


  • Open Access

    Two-Stage Optimization of Fluidized-Bed Powder Coating for Continuous Carbon Fiber-Reinforced Polyetheretherketone (CF/PEEK) Towpregs

    by Yusuf Yiğit, Mustafa Doğu, Mihrigül Ekşi Altan

    Solvent-free, continuous manufacture of carbon-fiber/poly(ether ether ketone) (CF/PEEK) towpregs via fluidized-bed powder coating requires stable powder fluidization together with controllable coating residence time. A laboratory-scale continuous coating line comprising a creel, guiding/tension rollers, a vibrated fluidized-bed coater, as well as a take-up unit was designed and commissioned. Subsequently, a two-stage optimization and modeling framework was developed. First, PEEK powder fluidization was optimized using a Taguchi L9 design, varying air pressure (P), powder weight (W), and vibration frequency (f); bed expansion ratio (ε) and average surface bubble diameter (Db) were measured and ANOVA identified air pressure as the primary contributor to ε (83.4%), establishing a stable operating window. Second, within this window, coating performance was assessed by varying line speed (Vline) and coating-roller position (Hr) in 12 runs and combining them into a geometry-based residence time (Rt) for simplified control. Coating quality was quantified based on fiber volume fraction (Vf) and composite tensile strength (σc) after consolidation. The best condition in the tested range was Hr=0.5 cm and Vline=1.5 m/min (Rt=0.54 s), achieving 61.5% Vf and 1800.5 MPa tensile strength. The resulting mathematical models predicted Vf and σc with good accuracy (R2≥0.92), supporting parameter selection and process optimization for continuous CF/PEEK towpreg production.

  • Wear behavior of additively manufactured auxetic re-entrant Ti6Al4V structures

    by Aysha Shawkat Hasan, Beyza Gavcar, Mihrigül Ekşi Altan

    Wear behavior plays a critical role in determining the durability and functional performance of lattice structures subjected to cyclic or contact loading. Auxetic lattice architectures, characterized by a negative Poisson's ratio, offer superior mechanical response and energy absorption compared to conventional cellular designs. This study investigates the reciprocating wear behavior of additively manufactured Ti6Al4V auxetic structures, focusing on the influence of unit cell geometry. Prismatic samples (20 × 10 × 10 mm 3 ) with varying strut thicknesses ( t 1 , t 2 ), inclined strut lengths ( L ), and inter-strut angles ( θ ) were fabricated using laser powder bed fusion. Reciprocating wear tests were performed under dry conditions using 100Cr6 steel balls as a counter body. The tribological response was evaluated based on the coefficient of friction (COF), specific wear rate, and worn surface morphology. Results revealed that the specific wear rate ranged from 2.023× 10 −4 to 1.875 × 10 −3 mm 3 /m·N, strongly influenced by both horizontal and inclined strut thicknesses as well as out-of-plane geometry. The COF varied between 0.31 and 0.45 and was primarily governed by the out-of-plane thickness and strut configuration. These findings highlight the critical role of unit cell geometry in controlling wear mechanisms and frictional response of additively manufactured auxetic lattices.


  • Development of porous customized Ti-6Al-4V cranial implant manufactured by laser beam powder bed fusion

    by Mihrigul Ekşi Altan, Alperen Acar, Seyhan Özen, Yeliz Güldorum, Eren Külle, Berke Apaydınlı, Abdulkadir Günay, Meltem Eryildiz

    Customized cranial implants play a crucial role in neurosurgery, serving to restore cranial integrity and protect the underlying brain tissue after trauma or surgical intervention. Ti-6Al-4V cranial implants exhibit high mechanical strength; however, their solid forms can be excessively heavy and possess a high elastic modulus, leading to stress shielding effects. This study focuses on designing a cranial implant utilizing computer tomography data, incorporating different lattice and porous structures to optimize weight and mechanical performance. The analysis, conducted with nTop software, compared displacement and von Mises stress values across different structures. The isotruss lattice structure emerged as the most effective, achieving a weight reduction of approximately 50% while maintaining a von Mises stress of 40 MPa. Following the computational analysis, Laser Beam Powder Bed Fusion (PBF-LB) was employed to fabricate the isotruss implant and the compression test was performed to mimic the cranial implant under realistic conditions. The isotruss lattice cranial implant exhibited a remarkable load-bearing capacity of up to 18,000 N while achieving a 50% weight reduction compared to the solid implant, indicating that this lightweight structure not only offers high-performance load-bearing capabilities but also shows great potential for use in surgical applications.


  • Open Access

    OPTIMIZATION OF 3D PRINTING PARAMETERS FOR PLA/PCL FILAMENT USING THE TAGUCHI METHOD: EFFECTS ON MECHANICAL PROPERTIES AND SHAPE MEMORY PERFORMANCE

    by Meltem Eryıldız, Bekir Kağan Kutluhan, Mihrigül Ekşi Altan

    This study investigates the optimization of 3D printing process parameters for PLA/PCL filament using the Taguchi method. A Taguchi L9 orthogonal array design was employed to explore the effects of print speed (40, 60, 80 mm/s), temperature (185,190,200°C), and infill pattern (the Lines, Gyroid, Triangle) on both mechanical and shape memory properties of the printed parts. The experiments were conducted using a Fused Deposition Modeling (FDM) 3D printer. The mechanical properties, including tensile strength, and shape memory properties such as shape recovery ratio, were evaluated for each combination of process parameters. The experiments revealed that a print speed of 40 mm/s, a nozzle temperature of 185°C, and the Lines infill pattern produced the best shape memory performance, achieving the shape recovery rate of 78.60% and the recovery time of 69 seconds. For tensile strength, the optimal conditions were found to be 40 mm/s, 185°C, and the Gyroid infill pattern, resulting in the highest tensile strength of 21.985 MPa. However, for simplicity and faster production, the Lines infill pattern is preferred. This research provides valuable insights for optimizing the 3D printing process of PLA/PCL filament and enhancing its mechanical and shape memory performance, which is crucial for various applications in biomedical, textile, and packaging industries.


  • Design, FEA and experimental validation of 3D-printed PLA/PCL intervertebral cages for lumbar spinal fusion

    by Meltem Eryildiz, Ozge Altintas Kadirhan, Mehmet Demirci, Aleyna Karakus, Mihrigul Eksi Altan

    This study examines the mechanical performance of novel PLA/PCL intervertebral cage designs for lumbar spinal fusion, using FEA and experimental compression testing. Four 3D-printed cage designs with varying graft window sizes and structural volumes were tested for load-bearing capacity. Experimental compressive strengths ranged from 43.36 MPa for Cage 4–50.43 MPa for Cage 3, all meeting the mechanical requirements of spinal applications. Cage 2, with a dual-window design, exhibited optimal load distribution and the highest compressive strength (50.00 MPa), indicating enhanced stability. Conversely, Cage 4, prioritizing graft space with the largest window, demonstrated the lowest compressive strength, revealing a trade-off between graft window size and structural support. FEA findings aligned well with experimental results, showing consistent trends in load distribution. Cage 2 exhibited the lowest von Mises stress, while Cage 4 had the highest stress concentrations, indicating vulnerability to deformation. This consistency between FEA and experimental data validates the reliability of FEA in evaluating cage designs. The findings suggest that PLA/PCL cages are viable alternatives to conventional materials, advancing the development of sustainable, patient-specific spinal fusion solutions. This study emphasizes the critical role of design in achieving a balance between structural support and potential for effective graft support in spinal implants.


  • Open Access

    Multifunctional property analysis of 3D ‐printed composite scaffolds from PLA / PCL filaments with graphene oxide reinforcement

    by Meltem Eryildiz, Aleyna Karakus, Mihrigül Eksi Altan

    This study investigates the multifunctional properties of three‐dimensional (3D)‐printed Polylactic acid (PLA) and Poly‐ε‐caprolactone (PCL) scaffolds reinforced with graphene oxide (GO) for advanced biomedical applications utilizing the fused filament fabrication method. PLA/PCL (80:20) was selected for its balance of stiffness and flexibility, while GO was incorporated at varying concentrations (0.5 weight percent (wt%), 1, 2, and 3 wt%). Composite filaments were produced through melt blending and extrusion, with subsequent 3D printing to create scaffolds. Fourier transform infrared spectroscopy analysis at 1 wt% GO revealed optimal functional group interactions. Differential scanning calorimetry and thermogravimetric analysis showed significantly enhanced thermal stability and crystallinity, while mechanical tests demonstrated 41.9% and 15% improvements in tensile and compressive strengths, respectively. Scanning electron microscopy analysis indicated morphological differences in the PLA/PCL matrix with increasing GO content. Rheological analysis indicated that lower GO concentrations led to an optimal viscosity, enhancing processability and maintaining structural integrity, with 1 wt% providing the best balance between ease of flow and mechanical stability. These findings highlight the potential of GO‐reinforced PLA/PCL scaffolds for biomedical applications, identifying 1 wt% GO as the optimal concentration for achieving superior thermal, mechanical, and rheological properties. Highlights: GO‐reinforced PLA/PCL filaments were successfully produced for scaffolds. GO enhances PLA/PCL scaffold strength, stability, and processability. 1 wt% GO improves thermal, mechanical, and rheological properties. GO boosts thermal stability, crystallinity, and structural integrity. SEM reveals PLA/PCL matrix changes with increasing GO content.


  • Open Access

    Optimization of Thermal, Mechanical, Biodegradation, and Shape Memory Properties in 4D‐Printed PLA/PCL Blends for Spinal Cages

    by Meltem Eryildiz, Aleyna Karakus, Mehmet Demirci, Ozge Altintas Kadirhan, Mihrigul Eksi Altan

    Spinal fusion cages play a crucial role in stabilizing the spine and promoting bone growth in degenerative spine disorders. Recent advancements in biodegradable polymer‐based cages have introduced materials with shape memory properties, enabling minimally invasive implantation and improved adaptability. This study focuses on the development of 4D‐printed PLA/PCL blend spinal cages, investigating their thermal, mechanical, biodegradation, and shape memory properties, alongside surface wettability through contact angle measurements. The novelty of this study lies in identifying the optimal PLA/PCL ratio, balancing mechanical strength, biodegradability, and shape memory behavior for spinal fusion applications. The findings highlight PLA/PCL (80:20) as the most suitable composition, offering a well‐balanced combination of properties. Differential scanning calorimetry (DSC) analysis revealed that 20 wt% PCL enhances toughness, flexibility, and crystallinity while slightly reducing the glass transition temperature. Mechanical testing showed improved fracture behavior and elongation at this ratio, with tensile stress peaking before decreasing at higher PCL concentrations due to increased ductility. Biodegradation studies confirmed an increasing degradation rate with higher PCL content, while contact angle measurements indicated greater hydrophilicity, though this trend reversed at higher concentrations. Shape memory analysis demonstrated that as PCL content increased from 10 to 60 wt%, shape recovery decreased from 76.07% to 61.28%, while high shape fixity (96.42%–99.80%) was maintained. The PLA/PCL20 blend exhibited a 74.5% shape memory effect and a 68.75% recovery rate in the spinal cage design, making it a promising material for minimally invasive spinal fusion applications.