Alissa R. Dangel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Alissa R. Dangel has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Alexander H. Slocum
Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue Building 3 Room 443, Cambridge, MA 02139, USA
1 shared publication Corinne M. Prigo
Tufts Medical Center - Dept. OB/GYN, 800 Washington St., Boston, MA, United States
1 shared publication- Elizabeth Chang-Davidson
Department of Mechanical Engineering,Carnegie Mellon University, Pittsburgh, PA 15213; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
1 shared publication - Galit H. Frydman
Division of Comparative Medicine and Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States
1 shared publication Jeannie C. Kelly
Tufts Medical Center - Dept. OB/GYN, 800 Washington St., Boston, MA, United States
1 shared publicationMallory Whalen
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
1 shared publication
Latest Publications
- 18 December 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 15 (2) , 021002
Device Prototype for Vaginal Delivery of Extremely Preterm Fetuses in the Breech Presentation
Vaginal delivery is typically avoided in the extremely preterm breech population due to the concern of entrapment by the cervix of the aftercoming head. A mechanical device concept is presented to enable vaginal delivery by preventing retraction of the cervix against the fetus during delivery. The two-part device was designed to dilate the cervix, prevent prolapse of small fetal parts and maintain sufficient dilation during delivery. The two-part device was designed and manufactured with the following modules: an inflatable saline-filled cervical balloon for dilation and a cervical retractor composed of semirigid beams to stabilize the cervix and maintain adequate dilation. The device was tested using a cervical phantom designed to simulate the compressive force the cervix exerts. The cervical balloon reached a maximum dilation of 8.5 cm, after which there was leakage of saline from the balloon. While this dilation was less than the target goal of 10 cm, the leaking was attributed to prototype manufacturing defects, which could be resolved with further development. The cervical retractor was able to withstand between 1–3 kPa. Although estimates of cervical pressure values can be upward of 30 kPa, there are no in vivo measurements to formally identify the pressure values for patients in preterm labor. This device serves as a viable proof-of-concept for utilizing an inflatable balloon device to prevent cervical retraction in the setting of extremely preterm vaginal breech delivery. Further manufacturing improvements and design changes could improve the device for continued development and testing.
- 18 December 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 15 (2) , 021002
Device Prototype for Vaginal Delivery of Extremely Preterm Fetuses in the Breech Presentation
Vaginal delivery is typically avoided in the extremely preterm breech population due to the concern of entrapment by the cervix of the aftercoming head. A mechanical device concept is presented to enable vaginal delivery by preventing retraction of the cervix against the fetus during delivery. The two-part device was designed to dilate the cervix, prevent prolapse of small fetal parts and maintain sufficient dilation during delivery. The two-part device was designed and manufactured with the following modules: an inflatable saline-filled cervical balloon for dilation and a cervical retractor composed of semirigid beams to stabilize the cervix and maintain adequate dilation. The device was tested using a cervical phantom designed to simulate the compressive force the cervix exerts. The cervical balloon reached a maximum dilation of 8.5 cm, after which there was leakage of saline from the balloon. While this dilation was less than the target goal of 10 cm, the leaking was attributed to prototype manufacturing defects, which could be resolved with further development. The cervical retractor was able to withstand between 1–3 kPa. Although estimates of cervical pressure values can be upward of 30 kPa, there are no in vivo measurements to formally identify the pressure values for patients in preterm labor. This device serves as a viable proof-of-concept for utilizing an inflatable balloon device to prevent cervical retraction in the setting of extremely preterm vaginal breech delivery. Further manufacturing improvements and design changes could improve the device for continued development and testing.
- 1 January 2020
- Published by Elsevier in Complementary Therapies in Medicine
- Vol. 48, 102235
Inpatient prenatal yoga sessions for women with high-risk pregnancies: A feasibility study
- 1 January 2020
- Published by Elsevier in Complementary Therapies in Medicine
- Vol. 48, 102235
Inpatient prenatal yoga sessions for women with high-risk pregnancies: A feasibility study