WLWenjun Lei

Wenjun Lei

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wenjun Lei has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The combustion and smoke spread characteristics of wood crib fires under sprinkler and mechanical smoke exhaust

    by Wenjun Lei, Zhenzhen Zhang, Chuanmin Tai, Ying Xu, Linhua Zhang

    Wood crib fires are a significant concern for fire safety, as they involve complex combustion and smoke dispersion behaviours that pose challenges for both prevention and control. This study investigated the combustion characteristics and smoke dispersion of wood crib fires, focusing on the role of mechanical smoke exhaust and sprinkler systems in fire safety management. The results showed that mechanical smoke exhaust increased the pyrolysis rate of the wood crib, with flame height rising by approximately 8.3% compared to natural combustion. The smoke layer height was effectively controlled by the mechanical exhaust, stabilizing at approximately 2.5 m when the system was activated. When the sprinkler system was turned on, flame height and combustion intensity were suppressed. The maximum flame height was reduced to 50% of that observed during natural combustion. Smoke temperature distribution along the height direction decreased linearly. A height of 1.0 m was reached by the smoke layer, which had decreased significantly. When both systems were used together, flame height and temperature were reduced by 15.8% and 53.7%, respectively, compared to natural combustion. The smoke layer reached a height of 1.5 m. These findings offer insights and guidance for optimizing fire prevention and control in wood crib fires.

  • Subcritical Velocity to Maintain the Fire-Induced Smoke Stratification in Tunnels During Construction Under Press-in Ventilation

    by Junhao Yu, Shengzhong Zhao, Tiantian Xu, Fei Wang, Zhaoyi Zhuang, Lin Xu, Wenjun Lei, Imad Obadi


  • Investigation on the effects of water mist and mechanical smoke extraction on fire combustion and smoke dispersion characteristics

    by Wenjun Lei, Yanhong Li, Chuanmin Tai, Mingqing Cai, Long Wang

    The combustion characteristics and smoke dispersion behaviours of indoor fires have always been critical topics in the field of building environment. The effects of a water mist system and a mechanical smoke extraction system on fire source combustion and smoke spread characteristics were investigated through full-scale experiments. The results indicated that mechanical smoke extraction could accelerate fire source combustion, resulting in the highest flame height. It could effectively reduce indoor temperature and would raise the smoke layer height to approximately 1.7 m. In contrast, the water mist system would suppress fire source combustion, reducing the flame height and controlling the temperature rise below 2 m to within 25°C. Albeit with a 0.2 m decrease in smoke layer height compared to the mechanical smoke extraction system. When both systems were operating synergistically, the fire source combustion was significantly suppressed, resulting in the lowest flame height observed. The smoke temperature was notably reduced, limiting the overall temperature increase in the room to within 15°C. However, the combined effect of both systems accelerated the downward spread of smoke, causing the smoke layer height to fall below 1.0 m. These findings suggest avenues for further exploration in optimizing fire prevention and control strategies.


  • Open Access

    Experimental study on the effect of makeup air inlets height on the fire combustion and smoke diffusion

    by Wenjun Lei, Zhenzhen Zhang, Yanhong Li, Zhanjiang Zheng, Chuanmin Tai, Linhua Zhang


  • Study on the Effect of Makeup Air Supplementation on Fire Smoke Control in Subway Tunnel

    by Xuming Zhao, Yufeng Gao, Wenjun Lei, Yue Qi, Chuanmin Tai, Debao Wang, Changlin Song

  • Open Access

    Effects of Train-Induced Unsteady Airflow on Air Quality and Air Distribution in a Subway Station

    by Hu Li, Hong Han, Xinjin Liu, Shujing Chen, Jingqian Wang, Wenjun Lei

    Using train-induced unsteady airflow in transitional seasons can greatly reduce the energy consumption of a subway station’s mechanical ventilation. However, the unsteady airflow carries the particles from tunnels into subway platforms, and airflow distribution at controllable vents is uneven. To determine the variation in PM2.5 (particulate matter of 2.5 micrograms or less) concentration and the air velocity distribution at the vents, field tests were conducted. The results showed that the PM2.5 concentrations at the vents and platform were positively correlated with the air velocity. The average ratio of the PM2.5 concentration at the vents to that on the platform was 71.15%. The maximum PM2.5 concentration and average PM2.5 concentration on the platform were 0.067 mg/m3 and 0.037 mg/m3, respectively. The air velocity distribution along the length of the platform conformed to logistic regression. Adjustment of the opening height of the vents was proposed to improve the air velocity distribution. Through numerical simulation, the ratio of the minimum airflow rate to the maximum airflow rate was increased from 5.9% to 37.5% after adjustment. This method is helpful for the uniform distribution of the airflow rate. This study will provide references for the design and operation of the vents of subway stations.


  • Open Access

    Analysis of dehumidification method and discussion on improvement measures in solar greenhouse

    by Hemei Lu, Wenjun Lei, Chuanmin Tai, Junbao Ye, Xinye Qi, Linhua Zhang, Xiaolong Wang

    The solar greenhouse is a passive agricultural facility building which can realize the anti-seasonal production. The main enclosure structure of solar greenhouse is composed of thermal insulation wall, thermal insulation roof and daylighting shed film. The transmittance of sunlight is an important index affecting the healthy growth of plants in solar greenhouse. After testing, the difference between the solar radiation intensity received through the greenhouse film and the outdoor solar radiation intensity during a day has large fluctuations. The reason for this phenomenon is that the humidity in the greenhouse is large, and there is condensation on the greenhouse film, which seriously affects the transmittance of sunlight. The dehumidification methods commonly used in solar greenhouses are summarized, and their advantages and disadvantages are analyzed in this paper. In addition, the problems existing in the current dehumidification methods are discussed. In view of the characteristics of the solar greenhouse that the high temperature needs ventilation and cooling during the day and the low temperature at night needs to supplement heat, a composite ventilation system with anti-condensation, heat storage, cooling and dehumidification is proposed, and its performance is analyzed.


  • Open Access

    Field measurement of indoor environment of underground garage in winter and analysis of its influence on people

    by Zhanjiang Zheng, Wenjun Lei, Haocheng Wang, Jinming Fu, Guohong Sun

    Since the National Fitness has become a national strategy, people’s enthusiasm for fitness has also been increasing. When winter comes, the outdoor temperature becomes unsuitable for people to carry out exercise activities. Therefore, more community residents choose underground garages as a place for fitness activities. Due to the frequently entry and exit of vehicles and ventilation restrictions in the underground garage, whether the internal air quality in an underground garage meets the requirements of personnel activities remains to be studied. In this study, an underground garage in a residential area of Jinan was tested. The parameters involved CO2, CO, PM2.5, temperature and relative humidity. Select areas where people often gather for measurement. According to the test results, the distribution of CO2, CO, PM2.5, temperature and relative humidity in the underground garage were quantitatively analyzed. It is found that the air quality in some areas of the underground garage is poor, and long-term activities in this environment will affect people’s health. To solve this problem, in this study, the area with relatively good air quality in the underground garage is found to provide personnel activities, and the optimization measu.res of winter ventilation in the underground garage were put forward.

  • Open Access

    Study on influence of breathing zone combined with underfloor makeup air supplement on smoke exhaust of road tunnel fire

    by Wenjun Lei, Yue Qi, Xinyu Zhang, Chuanmin Tai, Linhua Zhang, Guohong Sun

    In the era of rapid economic development, tunnel construction projects are increasing year by year in China, continuously expanding the urban network In the era of rapid economic development, tunnel construction projects are increasing year by year in China, continuously expanding the urban network radiation area, and accelerating the progress of the national modernization project. The subsequent tunnel traffic fire accidents are also increasing When a tunnel fire occurs, how to effectively supply makeup air to prevent the fire smoke from spreading to the evacuation passage of the When a tunnel fire occurs, how to effectively supply makeup air to prevent the fire smoke from spreading to the evacuation passage of the tunnel and exhaust the smoke as soon as possible has become a key concern in the field of tunnel disaster prevention. The layout of the smoke exhaust outlets under the mode of breathing zone combined with underfloor makeup air supplement was mainly used to study the problem of smoke exhaust in tunnel fires. The results show that under the same smoke exhaust flow rate, with the increase in the area of the results show that under the same smoke exhaust flow rate, with the increase in the area of the smoke outlet, the smoke exhaust efficiency of each exhaust outlet increases, and the total efficiency also increases. The width of the exhaust outlet has a significant effect on the smoke exhaust efficiency. However, the length of the exhaust vent has little effect on the efficiency of smoke exhaust. Under the mode of breathing zone combined with underfloor makeup air supplement, arranging smoke outlet with a size of 2 m×1.5 m every 10 m has a better smoke extraction effect, and the total smoke exhaust efficiency can reach 75.77%. Fire safety of road tunnels has always been the focus of social concern. The makeup air supplement and smoke exhaust mode proposed in this study is expected the makeup air supplement and smoke exhaust mode proposed in this study is expected to provide a theoretical basis for the design of tunnel smoke prevention and exhaust systems.