Jakob Højlund
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jakob Højlund has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Nicolai Bang Foss
Department of Anesthesiology and Intensive Care Copenhagen University Hospital–Hvidovre Copenhagen Denmark
4 shared publicationsDavid René Petersen
Department of Anaesthesiology, Hvidovre University Hospital, Capital Region, Denmark
2 shared publicationsMarianne Agerskov
Department of Anaesthesiology, Hvidovre University Hospital, Capital Region, Denmark
2 shared publicationsMirjana Cihoric
Department of Anesthesiology and Intensive Care Copenhagen University Hospital–Hvidovre Copenhagen Denmark
2 shared publicationsC. G. Clemmesen
Department of Anaesthesiology, Hvidovre University Hospital, Capital Region, Kettegaard Allé 30, 2650, Hvidovre, Denmark
1 shared publicationHenrik Wolsted
Department of Anesthesiology and Intensive Care Copenhagen University Hospital–Hvidovre Copenhagen Denmark
1 shared publication
Latest Publications
- Open Access
- 27 September 2026
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 70 (10) , e70338
Ability of the PulseCO Algorithm to Assess Changes in Stroke Volume Induced by Changes in Vascular Tone
Background: Vasoconstriction during anesthesia can influence stroke volume (SV) by preload modulation, making accurate SV monitoring essential to guide vasopressor therapy. Since gold standard methods like pulmonary artery catheterization and lithium dilution provide only intermittent estimates, continuous and less invasive arterial pulse contour analysis systems are increasingly used. However, their accuracy under altered vascular tone remains uncertain. We aimed to evaluate the PulseCO algorithm's (SV‐P) ability to detect clinically relevant changes in SV index (SVI) during manipulation of vascular tone, using lithium dilution with the LiDCO method (CI‐Li) as reference, and to assess how absolute systemic vascular resistance index (SVRI) levels influenced agreement between methods. Methods: In this prospective observational study, adult patients undergoing general anesthesia were monitored using continuous SV‐P and intermittent CI‐Li at three predefined time points: (1) supine baseline after anesthetic induction, (2) after head‐up tilt (HUT), and (3) during phenylephrine infusion in HUT. Agreement in SVI changes was assessed by directional concordance, absolute changes and Bland–Altman analysis, and the impact of vascular load was further explored by examining SVRI. A ≥ 10% change in SVI was defined as clinically relevant. Results: A total of 19 patients were included. Directional concordance between the two methods was 100% in both interventions. The SV‐P registered SVI changes ≥ 10% in all patients during both interventions, while lithium dilution registered this in 16 and 18 patients, respectively. The SV‐P consistently overestimated SVI changes compared with CI‐Li, with a non‐significant mean difference of −1.6 mL/m 2 (95% CI: −4.2 to 1.1, p = 0.28) from baseline to HUT, and a significant overestimation during phenylephrine infusion with a mean difference of 4.9 mL/m 2 (95% CI: 2.5 to 7.4, p = 0.001). Relative discrepancies between SV‐P and CI‐Li appeared to increase with higher SVRI. Conclusion: The arterial pulse wave‐based algorithm detected clinically relevant changes in SVI with 100% sensitivity and showed a 100% concordance with lithium dilution in the direction of change. However, it generally overestimated absolute SVI changes, and most markedly so during phenylephrine administration. Relative discrepancies in absolute SVI values appeared to increase with higher SVRI, highlighting that vascular load affects agreement. Editorial Comment: This study compares the performance of one device's pulse contour‐based estimates for stroke volume to estimates of stroke volume, same device, based on dilution‐based cardiac output and observed heart rate. This was also tracked during anesthesia interventions expected to alter peripheral vascular tone. These 2 methods for stroke volume (index) estimation agreed in direction of change with the clinical interventions, while pulse contour analysis appeared to overestimate changes in stroke volume compared to the flow‐based estimates.
- 27 September 2026
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 70 (10) , e70338
Open AccessAbility of the PulseCO Algorithm to Assess Changes in Stroke Volume Induced by Changes in Vascular Tone
Background: Vasoconstriction during anesthesia can influence stroke volume (SV) by preload modulation, making accurate SV monitoring essential to guide vasopressor therapy. Since gold standard methods like pulmonary artery catheterization and lithium dilution provide only intermittent estimates, continuous and less invasive arterial pulse contour analysis systems are increasingly used. However, their accuracy under altered vascular tone remains uncertain. We aimed to evaluate the PulseCO algorithm's (SV‐P) ability to detect clinically relevant changes in SV index (SVI) during manipulation of vascular tone, using lithium dilution with the LiDCO method (CI‐Li) as reference, and to assess how absolute systemic vascular resistance index (SVRI) levels influenced agreement between methods. Methods: In this prospective observational study, adult patients undergoing general anesthesia were monitored using continuous SV‐P and intermittent CI‐Li at three predefined time points: (1) supine baseline after anesthetic induction, (2) after head‐up tilt (HUT), and (3) during phenylephrine infusion in HUT. Agreement in SVI changes was assessed by directional concordance, absolute changes and Bland–Altman analysis, and the impact of vascular load was further explored by examining SVRI. A ≥ 10% change in SVI was defined as clinically relevant. Results: A total of 19 patients were included. Directional concordance between the two methods was 100% in both interventions. The SV‐P registered SVI changes ≥ 10% in all patients during both interventions, while lithium dilution registered this in 16 and 18 patients, respectively. The SV‐P consistently overestimated SVI changes compared with CI‐Li, with a non‐significant mean difference of −1.6 mL/m 2 (95% CI: −4.2 to 1.1, p = 0.28) from baseline to HUT, and a significant overestimation during phenylephrine infusion with a mean difference of 4.9 mL/m 2 (95% CI: 2.5 to 7.4, p = 0.001). Relative discrepancies between SV‐P and CI‐Li appeared to increase with higher SVRI. Conclusion: The arterial pulse wave‐based algorithm detected clinically relevant changes in SVI with 100% sensitivity and showed a 100% concordance with lithium dilution in the direction of change. However, it generally overestimated absolute SVI changes, and most markedly so during phenylephrine administration. Relative discrepancies in absolute SVI values appeared to increase with higher SVRI, highlighting that vascular load affects agreement. Editorial Comment: This study compares the performance of one device's pulse contour‐based estimates for stroke volume to estimates of stroke volume, same device, based on dilution‐based cardiac output and observed heart rate. This was also tracked during anesthesia interventions expected to alter peripheral vascular tone. These 2 methods for stroke volume (index) estimation agreed in direction of change with the clinical interventions, while pulse contour analysis appeared to overestimate changes in stroke volume compared to the flow‐based estimates.
- 11 August 2026
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 145 (3) , 800-801
Vasopressor Management in Surgical Patients: Comment
- 11 August 2026
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 145 (3) , 800-801
Vasopressor Management in Surgical Patients: Comment
- Open Access
- 21 June 2024
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (5) , 997-1002
Vasoconstriction with phenylephrine increases cardiac output in preload dependent patients
General Anaesthesia (GA) is accompanied by a marked decrease in sympathetic outflow and thus loss of vasomotor control of cardiac preload. The use of vasoconstriction during GA has mainly focused on maintaining blood pressure. Phenylephrine (PE) is a pure α1-agonist without inotropic effects widely used to correct intraoperative hypotension. The potential of PE for augmenting cardiac stroke volume (SV) and -output (CO) by venous recruitment is controversial and no human studies have explored the effects of PE in preload dependent circulation using indicator dilution technique. We hypothesized that PE-infusion in patients with cardiac stroke volume limited by reduced preload would restore preload and thus augment SV and CO. 20 patients undergoing GA for gastrointestinal surgery were monitored with arterial catheter and LiDCO unity monitor. Upon stable haemodynamics after induction patients were placed in head-up tilt (HUT). All patients became preload responsive as verified by a stroke volume variation (SVV) of > 12%. PE-infusion was then started at 15-20mikrg/min and adjusted until preload was restored (SVV < 12%). Li-dilution cardiac output (CO) was initially measured after induction (baseline), again with HUT in the preload responsive phase, and finally when preload was restored with infusion of PE.At baseline SVV was 10 ± 3% (mean ± st.dev.), CI was 2,6 ± 0,4 L/min*m2, and SVI 43 ± 7mL/m2. With HUT SVV was 19 ± 4%, CI was 2,2 ± 0,4 L/min*m2, SVI 35 ± 7mL/m2. During PE-infusion SVV was reduced to 6 ± 3%, CI increased to 2,6 ± 0,5 L/min*m2, and SVI increased to 49 ± 11mL/m2. All differences p < 0,001. In conclusion: Infusion of phenylephrine during preload dependency increased venous return abolishing preload dependency as evaluated by SVV and increased cardiac stroke volume and -output as measured by indicator-dilution technique. (ClinicalTrials.gov NCT05193097).
- 21 June 2024
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (5) , 997-1002
Open AccessVasoconstriction with phenylephrine increases cardiac output in preload dependent patients
General Anaesthesia (GA) is accompanied by a marked decrease in sympathetic outflow and thus loss of vasomotor control of cardiac preload. The use of vasoconstriction during GA has mainly focused on maintaining blood pressure. Phenylephrine (PE) is a pure α1-agonist without inotropic effects widely used to correct intraoperative hypotension. The potential of PE for augmenting cardiac stroke volume (SV) and -output (CO) by venous recruitment is controversial and no human studies have explored the effects of PE in preload dependent circulation using indicator dilution technique. We hypothesized that PE-infusion in patients with cardiac stroke volume limited by reduced preload would restore preload and thus augment SV and CO. 20 patients undergoing GA for gastrointestinal surgery were monitored with arterial catheter and LiDCO unity monitor. Upon stable haemodynamics after induction patients were placed in head-up tilt (HUT). All patients became preload responsive as verified by a stroke volume variation (SVV) of > 12%. PE-infusion was then started at 15-20mikrg/min and adjusted until preload was restored (SVV < 12%). Li-dilution cardiac output (CO) was initially measured after induction (baseline), again with HUT in the preload responsive phase, and finally when preload was restored with infusion of PE.At baseline SVV was 10 ± 3% (mean ± st.dev.), CI was 2,6 ± 0,4 L/min*m2, and SVI 43 ± 7mL/m2. With HUT SVV was 19 ± 4%, CI was 2,2 ± 0,4 L/min*m2, SVI 35 ± 7mL/m2. During PE-infusion SVV was reduced to 6 ± 3%, CI increased to 2,6 ± 0,5 L/min*m2, and SVI increased to 49 ± 11mL/m2. All differences p < 0,001. In conclusion: Infusion of phenylephrine during preload dependency increased venous return abolishing preload dependency as evaluated by SVV and increased cardiac stroke volume and -output as measured by indicator-dilution technique. (ClinicalTrials.gov NCT05193097).
- Open Access
- 8 June 2023
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 37 (6) , 1533-1540
“The peripheral perfusion index discriminates haemodynamic responses to induction of general anaesthesia”
Induction of general anaesthesia is often accompanied by hypotension. Standard haemodynamic monitoring during anaesthesia relies on intermittent blood pressure and heart rate. Continuous monitoring systemic blood pressure requires invasive or advanced modalities creating a barrier for obtaining important information of the circulation. The Peripheral Perfusion Index (PPI) is obtained non-invasively and continuously by standard photoplethysmography. We hypothesized that different patterns of changes in systemic haemodynamics during induction of general anaesthesia would be reflected in the PPI. Continuous values of PPI, stroke volume (SV), cardiac output (CO), and mean arterial pressure (MAP) were evaluated in 107 patients by either minimally invasive or non-invasive means in a mixed population of surgical patients. 2 min after induction of general anaesthesia relative changes of SV, CO, and MAP was compared to the relative changes of PPI. After induction total cohort mean(± st.dev.) MAP, SV, and CO decreased to 65(± 16)%, 74(± 18)%, and 63(± 16)% of baseline values. In the 38 patients where PPI decreased MAP was 57(± 14)%, SV was 63(± 18)%, and CO was 55(± 18)% of baseline values 2 min after induction. In the 69 patients where PPI increased the corresponding values were MAP 70(± 15)%, SV 80(± 16)%, and CO 68(± 17)% (all differences: p < 0,001). During induction of general anaesthesia changes in PPI discriminated between the degrees of reduction in blood pressure and algorithm derived cardiac stroke volume and -output. As such, the PPI has potential to be a simple and non-invasive indicator of the degree of post-induction haemodynamic changes.
- 8 June 2023
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 37 (6) , 1533-1540
Open Access“The peripheral perfusion index discriminates haemodynamic responses to induction of general anaesthesia”
Induction of general anaesthesia is often accompanied by hypotension. Standard haemodynamic monitoring during anaesthesia relies on intermittent blood pressure and heart rate. Continuous monitoring systemic blood pressure requires invasive or advanced modalities creating a barrier for obtaining important information of the circulation. The Peripheral Perfusion Index (PPI) is obtained non-invasively and continuously by standard photoplethysmography. We hypothesized that different patterns of changes in systemic haemodynamics during induction of general anaesthesia would be reflected in the PPI. Continuous values of PPI, stroke volume (SV), cardiac output (CO), and mean arterial pressure (MAP) were evaluated in 107 patients by either minimally invasive or non-invasive means in a mixed population of surgical patients. 2 min after induction of general anaesthesia relative changes of SV, CO, and MAP was compared to the relative changes of PPI. After induction total cohort mean(± st.dev.) MAP, SV, and CO decreased to 65(± 16)%, 74(± 18)%, and 63(± 16)% of baseline values. In the 38 patients where PPI decreased MAP was 57(± 14)%, SV was 63(± 18)%, and CO was 55(± 18)% of baseline values 2 min after induction. In the 69 patients where PPI increased the corresponding values were MAP 70(± 15)%, SV 80(± 16)%, and CO 68(± 17)% (all differences: p < 0,001). During induction of general anaesthesia changes in PPI discriminated between the degrees of reduction in blood pressure and algorithm derived cardiac stroke volume and -output. As such, the PPI has potential to be a simple and non-invasive indicator of the degree of post-induction haemodynamic changes.
- Open Access
- 9 January 2023
- Published by Springer Nature in Research Square
“The Peripheral Perfusion Index Discriminates Haemodynamic Responses to Induction of General Anaesthesia”
Purpose: Induction of general anaesthesia is often accompanied by hypotension. Standard haemodynamic monitoring during anaesthesia relies on intermittent blood pressure and heart rate. Continuous monitoring systemic blood pressure requires invasive or advanced modalities creating a barrier for obtaining important information of the circulation. The Peripheral Perfusion Index (PPI) is obtained non-invasively and continuously by standard photoplethysmography. We hypothesized that different patterns of changes in systemic haemodynamics during induction of general anaesthesia would be reflected in the PPI. Methods: PPI, stroke volume (SV), cardiac output (CO), and mean arterial pressure (MAP) was evaluated in 107 patients by either minimally invasive or non-invasive means in a mixed population of surgical patients. 2 minutes after induction of general anaesthesia relative changes of SV, CO and MAP was compared to the relative changes of PPI. Results: After induction total cohort mean(±st.dev.) MAP, SV, and CO decreased to 65(±16)%, 74(±18)%, and 63(±16)% of baseline values. In the 38 patients where PPI decreased MAP was 57(±14)% , SV was 63(±18)%, and CO was 55(±18)% of baseline values 2 minutes after induction. In the 69 patients where PPI increased the corresponding values were MAP 70(±15)%, SV 80(±16)%, and CO 68(±17)% (all differences: p < 0,001). Conclusion: During induction of general anaesthesia changes in PPI discriminated between the degrees of reduction in cardiac stroke volume and -output, and blood pressure. As such, the PPI has potential to be a simple and non-invasive indicator of the degree of post-induction haemodynamic changes.
- 9 January 2023
- Published by Springer Nature in Research Square
Open Access“The Peripheral Perfusion Index Discriminates Haemodynamic Responses to Induction of General Anaesthesia”
Purpose: Induction of general anaesthesia is often accompanied by hypotension. Standard haemodynamic monitoring during anaesthesia relies on intermittent blood pressure and heart rate. Continuous monitoring systemic blood pressure requires invasive or advanced modalities creating a barrier for obtaining important information of the circulation. The Peripheral Perfusion Index (PPI) is obtained non-invasively and continuously by standard photoplethysmography. We hypothesized that different patterns of changes in systemic haemodynamics during induction of general anaesthesia would be reflected in the PPI. Methods: PPI, stroke volume (SV), cardiac output (CO), and mean arterial pressure (MAP) was evaluated in 107 patients by either minimally invasive or non-invasive means in a mixed population of surgical patients. 2 minutes after induction of general anaesthesia relative changes of SV, CO and MAP was compared to the relative changes of PPI. Results: After induction total cohort mean(±st.dev.) MAP, SV, and CO decreased to 65(±16)%, 74(±18)%, and 63(±16)% of baseline values. In the 38 patients where PPI decreased MAP was 57(±14)% , SV was 63(±18)%, and CO was 55(±18)% of baseline values 2 minutes after induction. In the 69 patients where PPI increased the corresponding values were MAP 70(±15)%, SV 80(±16)%, and CO 68(±17)% (all differences: p < 0,001). Conclusion: During induction of general anaesthesia changes in PPI discriminated between the degrees of reduction in cardiac stroke volume and -output, and blood pressure. As such, the PPI has potential to be a simple and non-invasive indicator of the degree of post-induction haemodynamic changes.
- 9 November 2019
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 34 (6) , 1177-1184
The Peripheral Perfusion Index tracks systemic haemodynamics during general anaesthesia
Stable intraoperative haemodynamics are associated with improved outcome and even short periods of instability are associated with an increased risk of complications. During anaesthesia intermittent non-invasive blood pressure and heart rate remains the cornerstone of haemodynamic monitoring. Continuous monitoring of systemic blood pressure or even -flow requires invasive or advanced modalities creating a barrier for obtaining important real-time haemodynamic insight. The Peripheral Perfusion Index (PPI) is obtained continuously and non-invasively by standard photoplethysmography. We hypothesized that changes in indices of systemic blood flow during general anaesthesia would be reflected in the PPI. PPI, stroke volume (SV), cardiac output (CO) and mean arterial pressure (MAP) were evaluated in 20 patients. During general anaesthesia but before start of surgery relative changes of SV, CO and MAP were compared to the relative changes of PPI induced by head-up (HUT) and head-down tilt (HDT). Furthermore, the effect of phenylephrine (PE) during HUT on these parameters was investigated. ∆PPI correlated significantly (p < 0.001) with ∆SV (r = 0.9), ∆CO (r = 0.9), and ∆MAP (r = 0.9). HUT following induction of anaesthesia resulted in a decrease in PPI of 41% (25–52) [median (IQR)], SV 27% (23–31), CO 27% (25–35), and MAP 28% (22–35). HDT led to an increase in PPI of 203% (120–375), SV of 29% (21–41), CO 22% (16–34), and MAP 47% (42–60). After stabilizing a second HUT decreased PPI 59% (49–76), SV 33% (28–37), CO 31% (28–36), and MAP 34% (26–38). Restoration of preload with PE increased PPI by 607% (218–1078), SV by 96% (82–116), CO by 65% (56–99), and MAP by 114% (83–147). During general anaesthesia changes in PPI tracked changes in systemic haemodynamics.
- 9 November 2019
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 34 (6) , 1177-1184
The Peripheral Perfusion Index tracks systemic haemodynamics during general anaesthesia
Stable intraoperative haemodynamics are associated with improved outcome and even short periods of instability are associated with an increased risk of complications. During anaesthesia intermittent non-invasive blood pressure and heart rate remains the cornerstone of haemodynamic monitoring. Continuous monitoring of systemic blood pressure or even -flow requires invasive or advanced modalities creating a barrier for obtaining important real-time haemodynamic insight. The Peripheral Perfusion Index (PPI) is obtained continuously and non-invasively by standard photoplethysmography. We hypothesized that changes in indices of systemic blood flow during general anaesthesia would be reflected in the PPI. PPI, stroke volume (SV), cardiac output (CO) and mean arterial pressure (MAP) were evaluated in 20 patients. During general anaesthesia but before start of surgery relative changes of SV, CO and MAP were compared to the relative changes of PPI induced by head-up (HUT) and head-down tilt (HDT). Furthermore, the effect of phenylephrine (PE) during HUT on these parameters was investigated. ∆PPI correlated significantly (p < 0.001) with ∆SV (r = 0.9), ∆CO (r = 0.9), and ∆MAP (r = 0.9). HUT following induction of anaesthesia resulted in a decrease in PPI of 41% (25–52) [median (IQR)], SV 27% (23–31), CO 27% (25–35), and MAP 28% (22–35). HDT led to an increase in PPI of 203% (120–375), SV of 29% (21–41), CO 22% (16–34), and MAP 47% (42–60). After stabilizing a second HUT decreased PPI 59% (49–76), SV 33% (28–37), CO 31% (28–36), and MAP 34% (26–38). Restoration of preload with PE increased PPI by 607% (218–1078), SV by 96% (82–116), CO by 65% (56–99), and MAP by 114% (83–147). During general anaesthesia changes in PPI tracked changes in systemic haemodynamics.