Xin Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xin Wu has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Yangzhong Zhou
Fujian Key Laboratory of New Energy Generation and Power Conversion, Fuzhou University, Fuzhou, China
3 shared publications - Yao Chen
School of Marine Engineering, Jimei University, Xiamen 361021, China
1 shared publication
Latest Publications
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2861-2871
Fault-Tolerant Operation Control Strategy for Combined Winding Bearingless Flux-Switching Permanent Magnet Motor Drive System With One Opened Phase
The failure of the inverter bridge arm or the open circuit of the phase winding may occur during the operation of a combined winding bearingless flux-switching motor, causing both rotor rotation and suspension to malfunction, hence fault-tolerant control is vital for the motor's reliability and stability. In this paper, a fault-tolerant operation control strategy for combined winding bearingless flux-switching permanent magnet motors under open-circuit fault condition is proposed. Firstly, how to control the electromagnetic torque and suspension force acting on the rotor with the combined winding structure is explained, and then the mathematical models of the torque and suspension force which can be controlled individually by different current components are deduced in detail. Afterward, the relation of the phase current without and with winding fault is discussed, and the operation conditions of maintaining constant torque and suspension force after fault are demonstrated. Whereupon, the fault-tolerant control block diagram is constructed. Finally, the experimental results are presented to demonstrate the performance of the proposed strategy.
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2861-2871
Fault-Tolerant Operation Control Strategy for Combined Winding Bearingless Flux-Switching Permanent Magnet Motor Drive System With One Opened Phase
The failure of the inverter bridge arm or the open circuit of the phase winding may occur during the operation of a combined winding bearingless flux-switching motor, causing both rotor rotation and suspension to malfunction, hence fault-tolerant control is vital for the motor's reliability and stability. In this paper, a fault-tolerant operation control strategy for combined winding bearingless flux-switching permanent magnet motors under open-circuit fault condition is proposed. Firstly, how to control the electromagnetic torque and suspension force acting on the rotor with the combined winding structure is explained, and then the mathematical models of the torque and suspension force which can be controlled individually by different current components are deduced in detail. Afterward, the relation of the phase current without and with winding fault is discussed, and the operation conditions of maintaining constant torque and suspension force after fault are demonstrated. Whereupon, the fault-tolerant control block diagram is constructed. Finally, the experimental results are presented to demonstrate the performance of the proposed strategy.
- Open Access
- 25 February 2020
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 14 (5) , 872-884
Analytical calculation of magnetic field of bearingless flux‐switching permanent‐magnet machine based on doubly‐salient relative permeance method
A doubly‐salient relative permeance method is presented herein to predict the magnetic field of bearingless flux‐switching permanent‐magnet machines (BFSPMMs). Firstly, the subdomain model method is used to compute the magnetic field of slotless BFSPMMs. Then, the slotting effect of the stator and rotor is obtained by the doubly‐salient relative permeance method. By combining the two above, the air‐gap magnetic field of slotted BFSPMMs can be obtained. The doubly‐salient relative permeance method is based on the theory of the subdomain model method. The whole doubly‐salient structure is divided into several subdomains, and the Laplace equations for subdomains are established. Then, according to the boundary conditions between subdomains and the core, and the continuity conditions between adjacent subdomains, the equations are solved to calculate the slotting effect. Based on the proposed analytical model, the flux density and electromagnetic performances including back‐electromotive force (EMF), torque, and suspension force are predicted and compared with the finite element method results. Furthermore, the back‐EMF of the prototype motor is measured and the suspension experiments are carried out based on the analytical method. The comparison results and experiment results verify the validity of the analytical method.
- 25 February 2020
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 14 (5) , 872-884
Open AccessAnalytical calculation of magnetic field of bearingless flux‐switching permanent‐magnet machine based on doubly‐salient relative permeance method
A doubly‐salient relative permeance method is presented herein to predict the magnetic field of bearingless flux‐switching permanent‐magnet machines (BFSPMMs). Firstly, the subdomain model method is used to compute the magnetic field of slotless BFSPMMs. Then, the slotting effect of the stator and rotor is obtained by the doubly‐salient relative permeance method. By combining the two above, the air‐gap magnetic field of slotted BFSPMMs can be obtained. The doubly‐salient relative permeance method is based on the theory of the subdomain model method. The whole doubly‐salient structure is divided into several subdomains, and the Laplace equations for subdomains are established. Then, according to the boundary conditions between subdomains and the core, and the continuity conditions between adjacent subdomains, the equations are solved to calculate the slotting effect. Based on the proposed analytical model, the flux density and electromagnetic performances including back‐electromotive force (EMF), torque, and suspension force are predicted and compared with the finite element method results. Furthermore, the back‐EMF of the prototype motor is measured and the suspension experiments are carried out based on the analytical method. The comparison results and experiment results verify the validity of the analytical method.
- Open Access
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 158858-158871
Analytical Calculation of Electromagnetic Performances of Bearingless Flux-Switching Permanent-Magnet Machine Considering Iron Saturation Based on Exact Subdomain Model
In this paper, an accurate analytical subdomain model to calculate electromagnetic performances of bearingless flux-switching permanent magnet (BFSPM) machines is developed. The entire region of the machine is divided into six subdomains, including slots, air gap, magnets, and so on. According to the Neumann boundary conditions between the subdomains and the iron and the continuity conditions at the interface between the adjacent subdomains, the magnetic field distributions of subdomains are obtained by solving the Maxwell equations. In addition, a method to compensate the saturation effect is proposed, and the magnetic saturation of the stator and rotor is considered by the actual B-H characteristics. Based on the proposed analytical method, the air-gap flux density distributions of the machine with different iron material under linear and nonlinear conditions are predicted. Further, the electromagnetic performances including the cogging torque, electromagnetic torque, flux linkage, back-EMF, inductance, and suspension force are calculated. These analytical results are compared with those obtained by the Finite Element Analysis (FEA) to verify the accuracy of the proposed analytical method.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 158858-158871
Open AccessAnalytical Calculation of Electromagnetic Performances of Bearingless Flux-Switching Permanent-Magnet Machine Considering Iron Saturation Based on Exact Subdomain Model
In this paper, an accurate analytical subdomain model to calculate electromagnetic performances of bearingless flux-switching permanent magnet (BFSPM) machines is developed. The entire region of the machine is divided into six subdomains, including slots, air gap, magnets, and so on. According to the Neumann boundary conditions between the subdomains and the iron and the continuity conditions at the interface between the adjacent subdomains, the magnetic field distributions of subdomains are obtained by solving the Maxwell equations. In addition, a method to compensate the saturation effect is proposed, and the magnetic saturation of the stator and rotor is considered by the actual B-H characteristics. Based on the proposed analytical method, the air-gap flux density distributions of the machine with different iron material under linear and nonlinear conditions are predicted. Further, the electromagnetic performances including the cogging torque, electromagnetic torque, flux linkage, back-EMF, inductance, and suspension force are calculated. These analytical results are compared with those obtained by the Finite Element Analysis (FEA) to verify the accuracy of the proposed analytical method.