Yeoju Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yeoju Kim has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Woojae Han
Division of Speech Pathology and Audiology, Research Institute of Audiology and Speech Pathology, Hallym University, Chuncheon, Korea
6 shared publications - Da-Hui Kim
Department of Dental Hygiene, Andong Science College, Andong, Korea
2 shared publications - Jieun Joo
Laboratory of Hearing and Technology, College of Natural Sciences, Hallym University, Chuncheon, Korea
2 shared publications - Sangmin Park
Laboratory of Hearing and Technology, College of Natural Sciences, Hallym University, Chuncheon, Korea
2 shared publications - Sunghwa You
Research Institute of Hearing Enhancement, Yonsei University Wonju College of Medicine
2 shared publications - Sunmi Ma
Laboratory of Hearing and Technology, College of Natural Sciences, Hallym University, Chuncheon, Korea
2 shared publications
Latest Publications
- Open Access
- 30 January 2026
- Published by Korean Academy of Audiology in Audiology and Speech Research
- Vol. 22 (1) , 21-33
Perceptual Error Analysis of Korean Monosyllabic Word Recognition I: Error Rates and Types According to Hearing Level
Purpose: This study aims to analyze the error rates and types of Korean monosyllabic word perception according to hearing level, providing detailed insight into phoneme-specific error patterns among elderly individuals with varying degrees of hearing loss. Methods: Seventy-two elderly participants were assigned to four hearing groups: normal hearing, mild, moderate, and severe hearing loss. Each completed a monosyllabic word discrimination task using 726 Korean monosyllabic stimuli, presented at their most comfortable listening level. Error rates were calculated for onset consonant, vowel, and coda positions, and errors were classified by segmental pattern (substitution, addition, omission, compound). Data were analyzed using one-way analysis of variance and post-hoc tests for group differences. Results: Total error rates increased according to hearing loss severity, from 18.3% in normal listeners to 80.4% in severe loss. Initial consonant errors were notably high, with severe-impaired participants showing over 80% errors in high-frequency onset consonants. Substitution errors predominated in all groups but decreased as hearing loss worsened; omission and compound errors correspondingly increased, especially in severe cases. Compound segmental errors became more common as hearing deteriorated, signifying much global breakdowns in word perception. Conclusion: Age-related hearing loss leads to a marked shift from single-segment errors toward frequent multisegment and compound errors in monosyllabic word perception. These findings highlight the need for detailed error analysis in clinical speech tests and endorse individualized rehabilitation approaches tailored for older adults’ auditory-perceptual profiles.
- 30 January 2026
- Published by Korean Academy of Audiology in Audiology and Speech Research
- Vol. 22 (1) , 21-33
Open AccessPerceptual Error Analysis of Korean Monosyllabic Word Recognition I: Error Rates and Types According to Hearing Level
Purpose: This study aims to analyze the error rates and types of Korean monosyllabic word perception according to hearing level, providing detailed insight into phoneme-specific error patterns among elderly individuals with varying degrees of hearing loss. Methods: Seventy-two elderly participants were assigned to four hearing groups: normal hearing, mild, moderate, and severe hearing loss. Each completed a monosyllabic word discrimination task using 726 Korean monosyllabic stimuli, presented at their most comfortable listening level. Error rates were calculated for onset consonant, vowel, and coda positions, and errors were classified by segmental pattern (substitution, addition, omission, compound). Data were analyzed using one-way analysis of variance and post-hoc tests for group differences. Results: Total error rates increased according to hearing loss severity, from 18.3% in normal listeners to 80.4% in severe loss. Initial consonant errors were notably high, with severe-impaired participants showing over 80% errors in high-frequency onset consonants. Substitution errors predominated in all groups but decreased as hearing loss worsened; omission and compound errors correspondingly increased, especially in severe cases. Compound segmental errors became more common as hearing deteriorated, signifying much global breakdowns in word perception. Conclusion: Age-related hearing loss leads to a marked shift from single-segment errors toward frequent multisegment and compound errors in monosyllabic word perception. These findings highlight the need for detailed error analysis in clinical speech tests and endorse individualized rehabilitation approaches tailored for older adults’ auditory-perceptual profiles.
- Open Access
- 30 January 2026
- Published by Korean Academy of Audiology in Audiology and Speech Research
- Vol. 22 (1) , 34-41
Perceptual Error Analysis of Korean Monosyllabic Word Recognition II: Similarity and Distance According to Hearing Level
Purpose: This study aimed to analyze perceptual error patterns and mapping in Korean monosyllabic word recognition across different hearing levels, using confusion matrix analysis to quantify phoneme similarity and perceptual distance. By examining detailed phoneme-level confusions, the research sought to clarify how hearing loss alters recognition and discrimination. Methods: Seventytwo participants were divided into four hearing groups: normal hearing, mild, moderate, and severe hearing loss. Each participant listened to 726 Korean monosyllabic words spoken in a controlled acoustic environment and provided identifications for each. Recognition errors were systematically classified according to onset, nucleus, and coda positions. Confusion matrices were generated for each group and a six-level error bracket classification applied. Perceptual similarity and distance among phoneme pairs were assessed using Shepard’s Law and perceptual mapping was visualized for each hearing group. Results: Phoneme recognition accuracy declined with increasing hearing loss, most notably for onset and nucleus positions. Moderate and severe hearing loss groups exhibited significantly higher error rates and larger perceptual distances than normal hearing and mild loss groups. The total similarity counts for onset, vowel, and coda all increased as hearing impairment worsened. Severe hearing loss participants showed peak perceptual distances for critical phoneme pairs, indicating diminished discrimination ability. Group-wise perceptual maps clearly differentiated error patterns by hearing condition. Conclusion: Hearing loss substantially compromises Korean monosyllabic word recognition, leading to elevated error rates and increased perceptual distances among phonemes. These findings underscore the necessity for hearing-level-specific aural rehabilitation strategies and provide foundational auditory mapping data for hearing-impaired populations.
- 30 January 2026
- Published by Korean Academy of Audiology in Audiology and Speech Research
- Vol. 22 (1) , 34-41
Open AccessPerceptual Error Analysis of Korean Monosyllabic Word Recognition II: Similarity and Distance According to Hearing Level
Purpose: This study aimed to analyze perceptual error patterns and mapping in Korean monosyllabic word recognition across different hearing levels, using confusion matrix analysis to quantify phoneme similarity and perceptual distance. By examining detailed phoneme-level confusions, the research sought to clarify how hearing loss alters recognition and discrimination. Methods: Seventytwo participants were divided into four hearing groups: normal hearing, mild, moderate, and severe hearing loss. Each participant listened to 726 Korean monosyllabic words spoken in a controlled acoustic environment and provided identifications for each. Recognition errors were systematically classified according to onset, nucleus, and coda positions. Confusion matrices were generated for each group and a six-level error bracket classification applied. Perceptual similarity and distance among phoneme pairs were assessed using Shepard’s Law and perceptual mapping was visualized for each hearing group. Results: Phoneme recognition accuracy declined with increasing hearing loss, most notably for onset and nucleus positions. Moderate and severe hearing loss groups exhibited significantly higher error rates and larger perceptual distances than normal hearing and mild loss groups. The total similarity counts for onset, vowel, and coda all increased as hearing impairment worsened. Severe hearing loss participants showed peak perceptual distances for critical phoneme pairs, indicating diminished discrimination ability. Group-wise perceptual maps clearly differentiated error patterns by hearing condition. Conclusion: Hearing loss substantially compromises Korean monosyllabic word recognition, leading to elevated error rates and increased perceptual distances among phonemes. These findings underscore the necessity for hearing-level-specific aural rehabilitation strategies and provide foundational auditory mapping data for hearing-impaired populations.
- Open Access
- 31 December 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (4) , 120-127
In Vitro Evaluation of Stain Inhibition and Color Stability of a Multifunctional Dentifrice under Coffee and Black Tea Staining Conditions
Won-Ju Kang, Yeo-Ju Kim, Cheon-Hee Lee. IJCPD 2025;21:120-7. https://doi.org/10.15236/ijcpd.2025.21.4.120
- 31 December 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (4) , 120-127
Open AccessIn Vitro Evaluation of Stain Inhibition and Color Stability of a Multifunctional Dentifrice under Coffee and Black Tea Staining Conditions
Won-Ju Kang, Yeo-Ju Kim, Cheon-Hee Lee. IJCPD 2025;21:120-7. https://doi.org/10.15236/ijcpd.2025.21.4.120
- Open Access
- 31 December 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (4) , 136-142
In Vitro Evaluation of Whitening Efficacy, Color Stability, and Enamel Microhardness of Hydrogen Peroxide–Containing Dentifrices under Repeated Application Conditions
Seul-Ah Ji, Yeo-Ju Kim, Su-Kyung Jwa. IJCPD 2025;21:136-42. https://doi.org/10.15236/ijcpd.2025.21.4.136
- 31 December 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (4) , 136-142
Open AccessIn Vitro Evaluation of Whitening Efficacy, Color Stability, and Enamel Microhardness of Hydrogen Peroxide–Containing Dentifrices under Repeated Application Conditions
Seul-Ah Ji, Yeo-Ju Kim, Su-Kyung Jwa. IJCPD 2025;21:136-42. https://doi.org/10.15236/ijcpd.2025.21.4.136
- Open Access
- 31 December 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (4) , 97-102
Effects of a Multifunctional Dentifrice on Dentin Microhardness and Dentinal Tubule Occlusion: An In Vitro Study
Hyon-Mo Ku, Yeo-Ju Kim, Da-Hui Kim. IJCPD 2025;21:97-102. https://doi.org/10.15236/ijcpd.2025.21.4.97
- 31 December 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (4) , 97-102
Open AccessEffects of a Multifunctional Dentifrice on Dentin Microhardness and Dentinal Tubule Occlusion: An In Vitro Study
Hyon-Mo Ku, Yeo-Ju Kim, Da-Hui Kim. IJCPD 2025;21:97-102. https://doi.org/10.15236/ijcpd.2025.21.4.97
- Open Access
- 30 April 2023
- Published by Korean Academy of Audiology in Audiology and Speech Research
- Vol. 19 (2) , 77-90
Recommended Auditory Brainstem Responses to Stimulation and Recording Parameters for Hidden Hearing Loss: A Systematic Review and Meta-Analysis
Although a lesion of hidden hearing loss (HHL) has focused on the sprial ganglion, stimulation and recording parameters for auditory brainstem response (ABR) are not yet specific enough to confirm its dysfunction. In the current review, we identify ABR parameters, especially Wave I, for diagnosing HHL through both a systemic review and meta-analysis of 14 articles retrieved from seven journal data bases. The most commonly used parameters were a click or 4 kHz tone burst as the stimulus at a rate of less than 11/sec at more than 80 dB intensity levels with alternating polarity through the ear canal. For quantitative results, our meta-analysis from eight articles demonstrated a significant difference in the overall effect size for amplitude between HHL patients and their counterparts with normal hearing. For the subgroup and its analysis, tone burst and high intensity level revealed significantly lower effect size in HHL patients compared to the control group, whereas the stimuli rate and electrode montage statstically were not statistical significance. Although we examined a small number of studies and their heterogenity, obtaining ABR Wave I was clinically differentiated when noise-induced HHL was considered. We thus suggest that stimulation and recording parameters should be applied to a large number of patients and thereby standardized as sensitive features for Wave I in the clinic.
- 30 April 2023
- Published by Korean Academy of Audiology in Audiology and Speech Research
- Vol. 19 (2) , 77-90
Open AccessRecommended Auditory Brainstem Responses to Stimulation and Recording Parameters for Hidden Hearing Loss: A Systematic Review and Meta-Analysis
Although a lesion of hidden hearing loss (HHL) has focused on the sprial ganglion, stimulation and recording parameters for auditory brainstem response (ABR) are not yet specific enough to confirm its dysfunction. In the current review, we identify ABR parameters, especially Wave I, for diagnosing HHL through both a systemic review and meta-analysis of 14 articles retrieved from seven journal data bases. The most commonly used parameters were a click or 4 kHz tone burst as the stimulus at a rate of less than 11/sec at more than 80 dB intensity levels with alternating polarity through the ear canal. For quantitative results, our meta-analysis from eight articles demonstrated a significant difference in the overall effect size for amplitude between HHL patients and their counterparts with normal hearing. For the subgroup and its analysis, tone burst and high intensity level revealed significantly lower effect size in HHL patients compared to the control group, whereas the stimuli rate and electrode montage statstically were not statistical significance. Although we examined a small number of studies and their heterogenity, obtaining ABR Wave I was clinically differentiated when noise-induced HHL was considered. We thus suggest that stimulation and recording parameters should be applied to a large number of patients and thereby standardized as sensitive features for Wave I in the clinic.
- Open Access
- 30 September 2020
- Published by The Korean Academy of Preventive Dentistry and Oral Health in Journal of Korean Academy of Oral Health
- Vol. 44 (3) , 166-172
Preliminary study for the development of a visiting oral health care intervention program for the elderly based on community healthcare
Jong-Hwa Jang, Ja-Won Cho, Yeo-Ju Kim, Ji-Yun Ki, Kyung-Sook Jo, Ji-Ryang Kim, Jung-Eun Park, Da-Hui Kim. J Korean Acad Oral Health 2020;44:166-72. https://doi.org/10.11149/jkaoh.2020.44.3.166
- 30 September 2020
- Published by The Korean Academy of Preventive Dentistry and Oral Health in Journal of Korean Academy of Oral Health
- Vol. 44 (3) , 166-172
Open AccessPreliminary study for the development of a visiting oral health care intervention program for the elderly based on community healthcare
Jong-Hwa Jang, Ja-Won Cho, Yeo-Ju Kim, Ji-Yun Ki, Kyung-Sook Jo, Ji-Ryang Kim, Jung-Eun Park, Da-Hui Kim. J Korean Acad Oral Health 2020;44:166-72. https://doi.org/10.11149/jkaoh.2020.44.3.166
- Open Access
- 10 April 2020
- Published by The Korean Audiological Society in Journal of Audiology and Otology
- Vol. 24 (2) , 85-90
Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses
Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships.Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject’s right mastoid. While the subject’s thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual’s hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli.Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR.Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.
- 10 April 2020
- Published by The Korean Audiological Society in Journal of Audiology and Otology
- Vol. 24 (2) , 85-90
Open AccessBetter Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses
Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships.Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject’s right mastoid. While the subject’s thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual’s hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli.Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR.Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.
- Open Access
- 21 January 2020
- Published by Korean Society of Otorhinolaryngology-Head and Neck Surgery in Korean Journal of Otorhinolaryngology-Head and Neck Surgery
- Vol. 63 (1) , 14-20
Establishment of Normative Data for Auditory Brainstem Responses in White Noise Condition
서 론 청성유발전위(auditory evoked potentials)는 발현되는 전 위의 잠복기에 따라 초기반응(10~15 ms), 중기반응(10~80 ms), 후기반응(80~750 ms)으로 분류된다. 1) 그 중 초기반응에 해당하는 청성뇌간반응(auditory brainstem response, ABR) 은 Sohmer와 Feinmesser 2) 에 의해 처음 보고된 이후, 다양한 연구들이 수많은 임상가들에 의해 체계적으로 진행되었다. 청성뇌간반응은 외부로부터 자극된 청각적 신호가 대뇌에 전달되는 과정 중 주로 뇌간에서 발생하는 활동전위를 의미 하며, 신호 제시 후 약 10~15 ms 이내에서 파형들이 나타난 다. 청각 경로의 전달 과정에서 가장 두드러진 정점들인 I-V 번 파형의 결과를 통해 해부학적 위치에 따라 병변의 유무를 구분할 수 있다. 즉, I번과 II번 파형은 청신경(auditory nerve)의 말초와 근부, III번 파형은 와우핵 능형체(cochlear
- 21 January 2020
- Published by Korean Society of Otorhinolaryngology-Head and Neck Surgery in Korean Journal of Otorhinolaryngology-Head and Neck Surgery
- Vol. 63 (1) , 14-20
Open AccessEstablishment of Normative Data for Auditory Brainstem Responses in White Noise Condition
서 론 청성유발전위(auditory evoked potentials)는 발현되는 전 위의 잠복기에 따라 초기반응(10~15 ms), 중기반응(10~80 ms), 후기반응(80~750 ms)으로 분류된다. 1) 그 중 초기반응에 해당하는 청성뇌간반응(auditory brainstem response, ABR) 은 Sohmer와 Feinmesser 2) 에 의해 처음 보고된 이후, 다양한 연구들이 수많은 임상가들에 의해 체계적으로 진행되었다. 청성뇌간반응은 외부로부터 자극된 청각적 신호가 대뇌에 전달되는 과정 중 주로 뇌간에서 발생하는 활동전위를 의미 하며, 신호 제시 후 약 10~15 ms 이내에서 파형들이 나타난 다. 청각 경로의 전달 과정에서 가장 두드러진 정점들인 I-V 번 파형의 결과를 통해 해부학적 위치에 따라 병변의 유무를 구분할 수 있다. 즉, I번과 II번 파형은 청신경(auditory nerve)의 말초와 근부, III번 파형은 와우핵 능형체(cochlear
- Open Access
- 31 October 2019
- Published by Korean Academy of Audiology in Audiology and Speech Research
- Vol. 15 (4) , 343-351
Necessity of Noise Map for Smart Protection from Environmental Noise
- 31 October 2019
- Published by Korean Academy of Audiology in Audiology and Speech Research
- Vol. 15 (4) , 343-351
Open AccessNecessity of Noise Map for Smart Protection from Environmental Noise