Paul C. McAfee

Paul C. McAfee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paul C. McAfee has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Biomechanical Analysis of Rotational Motions After Disc Arthroplasty

    by Paul C. McAfee, Bryan W. Mmech Cunningham, Victor Hayes, Farhan Sidiqi, Michael Dabbah, John C. Do Sefter, Nianbin Hu, Helen Bs Beatson

    Study Design. An anatomic and biomechanical bench-top basic scientific comparative analysis to determine the appropriateness of total disc replacement (TDR) in a lumbar spine with scoliotic tendencies. Objectives. Only limited data are currently available studying the application of disc replacement adjacent to scoliosis fusions. Theoretically, motion preservation should help delay the continuum of lumbar degeneration adjacent to scoliosis fusions and rotationally unstable lumbar segments. Summary of Background Data. As a tertiary referral center for failed TDR, we noticed an alarming number of lumbar spinal rotational iatrogenic instability patterns but none occurring in the cervical spine. It is appropriate to analyze the bench-top rotational stability of disc replacement to predict whether this new technology is feasible for a larger prospective clinical study in the treatment of degenerative scoliosis. Methods. Measurements were taken from 60 human specimens from the Hamann-Todd Osteological Collection: 1) to determine the rotational arc of influence (AOI) = the angle formed from the center of axial rotation to the outermost extent of the facet joints; and 2) to determine the relative anatomic size discrepancy between the left and right facets proportionately with the cross-sectional area of the intervertebral disc = facet/endplate ratio (FER). Biomechanical testing was performed using fresh frozen human cadaveric spines with the following conditions to determine the rotational stability: 1) intact; 2) resection of ALL, anulus, disc, and PLL simulating the preparation for a TDR; 3) a more radical anular resection; 4) entire 360° anular resection; and 4) insertion of the respective unconstrained-type disc replacement. Using a 6 degrees of freedom spine simulator, unconstrained pure moments of ±8.0 Nm (lumbar) and ±3.0 Nm (cervical) were used for axial rotation with quantification of the operative level range of motion and neutral zone, with data normalized to the intact spine condition. Results. There were anatomic limitations in the lumbar spine that make it less desirable to apply uncon-strained disc replacements; indeed, the spine was at risk for iatrogenic lumbar scoliosis. The anulus fibrosis, anterior longitudinal ligament, and the posterior longitudinal ligament are critical structures in preventing iatrogenic scoliosis. The lumbar facet joints are more posteriorly located and are smaller relative to the intervertebral disc, compared with this association in the cervical spine. Because the facet capsular ligaments are mechanically less effective with lower tensile strength in the lumbar spine, multiple-level arthroplasty tends to accentuate scoliotic tendencies; this is independent of prosthetic design and surgical technique. Discussion. Implantation of the lumbar TDR never restored the motion segment back to the rotational stability of the intact segment achieving a range of 120% to 140% rotational range of motion compared with the intact condition. This rotational instability proved to be additive as a two-level lumbar TDR resulted in between 240% and 260% increase in rotational instability compared with the intact condition. Conclusion. The neutral zone of the intact cervical spine was restored even using an unconstrained cervical TDR. The greater inherent rotational constraints of the cervical spine make it more amenable to stable multilevel arthroplasty compared with the lumbar spine.


  • Revisability of the CHARITÉ Artificial Disc Replacement

    by Paul C. McAfee, Fred H. Geisler, Samer S. Saiedy, Sandra V. Moore, John J. Regan, Richard D. Guyer, Scott L. Blumenthal, Ira L. Fedder, P Justin Tortolani, Bryan Cunningham

    A prospective, randomized, multicenter, FDA-regulated Investigational Device Exemption clinical trial. To analyze the incidence of, and reasons for, reoperation in all patients (treatment and control) enrolled in the IDE study. This is the first report of the incidence and nature of reoperations following lumbar TDR as part of a controlled, prospective, multicenter trial. A total of 688 patients meeting the inclusion and exclusion criteria were enrolled in one of three arms of the study at 14 centers across the United States. This cohort includes 71 nonrandomized cases, 205 randomized cases, and 313 continued access cases, all receiving the CHARITE Artificial Disc, as well as 99 randomized cases in the control group (ALIF with threaded fusion cages and autograft). A detailed analysis was performed of clinical chart notes, operative notes, and adverse event reports for all patients requiring reoperation following their index surgery. Of the 589 patients with TDR, 52 (8.8%) required reoperation. Of the 99 patients with lumbar fusion, 10 (10.1%) required reoperation, and an additional 2 required surgery for adjacent level disease (P = 0.7401). There were 24 TDR patients who underwent a repeated anterior retroperitoneal approach, with 22 (91.7%) having had a successful removal of the prosthesis. Seven of the 24 TDR prostheses requiring removal were revised to another CHARITE Artificial Disc. The mean time to reoperation in all patients was 9.7 months. A total of 29 patients (4.9%) in the TDR group required posterior instrumentation and fusion as did 10 (10.1%) in the control group (P = 0.0562). At 2 years or more follow-up, 93.9%(553/589 = 93.9%) of patients receiving TDR with the CHARITE Artificial Disc had a successfully functioning prosthesis with a mean of over 7 degrees of flexion-extension mobility. Lumbar TDR with the CHARITE Artificial Disc did not preclude any further procedures at the index level during primary insertion, with nearly one third being revisable to a new motion-preserving prosthesis and just over two thirds being successfully converted to ALIF and/ or posterior pedicle screw arthrodesis, the original alternative procedure.


  • A Prospective, Randomized, Multicenter Food and Drug Administration Investigational Device Exemption Study of Lumbar Total Disc Replacement With the CHARITÉ ™ Artificial Disc Versus Lumbar Fusion

    by Paul C. McAfee, Bryan Cunningham, Gwen Holsapple, Karen Adams, Scott Blumenthal, Richard D. Guyer, Anton Dmietriev, James H. Maxwell, John J. Regan, Jorge Isaza

    A prospective, randomized, multicenter, Food and Drug Administration-regulated, investigational device exemption clinical trial. To compare the safety and effectiveness of lumbar total disc replacement (TDR) with the CHARITE artificial disc (DePuy Spine, Raynham, MA) to anterior lumbar interbody fusion for the treatment of single-level degenerative disc disease from L4-S1 unresponsive to nonoperative treatment. In addition, to evaluate the radiographic outcomes of lumbar artificial disc replacement at either L4-L5 or L5-S1 with the CHARITE artificial disc as compared to anterior lumbar interbody fusion with cylindrical cages and iliac crest bone graft; and to determine if a correlation exists between clinical outcomes and surgical accuracy of TDR placement within the disc space. Prior investigators have reported excellent radiographic results with the CHARITE artificial disc for the treatment of lumbar degenerative disc disease. These encouraging results are the product of retrospective reviews without a control. Very few studies have reported on the segmental motion of an intervertebral level implanted with an artificial disc, and no studies have reported a correlation of radiographic and clinical outcomes. A prospective, randomized, multicenter, US Food and Drug Administration, investigational device exemption study with 24-month follow-up was performed at 14 centers throughout the United States. A total of 304 subjects were randomized in a 2:1 ratio, with 205 in the investigational group (TDR with the CHARITE artificial disc) and 99 in the control group (anterior lumbar interbody fusion with BAK cages and iliac crest bone graft). A total of 71 TDR training cases were performed (up to 5 at each site) before randomization beginning at each site. Plain radiographs were analyzed for each subject in both groups regarding range of motion (ROM) in flexion/extension, restoration of disc space height, and subsidence. Prosthesis placement in the coronal and midsagittal planes was analyzed for the 276 patients with TDR. Correlations were performed between prosthesis placement and clinical outcomes. Patients in the investigational group had a 13.6% mean increase, and those in the control group an 82.5% decrease in mean flexion/extension ROM at 24 months postoperatively compared to baseline. Patients in the investigational group had significantly better restoration of disc height than the control group (P < 0.05). There was significantly less subsidence in the investigational group compared to the control group (P < 0.05). The surgical technical accuracy of CHARITE artificial disc placement was divided into 3 groups: I, ideal (83%); II, suboptimal (11%); and III, poor (6%), and correlated with clinical outcomes. The flexion/extension ROM and prosthesis function improved with the surgical technical accuracy of radiographic placement (P = 0.003). Preoperative ROM in flexion/extension was restored and maintained in patients receiving a TDR. TDR with the CHARITE artificial disc resulted in significantly better restoration of disc space height, and significantly less subsidence than anterior interbody fusion with BAK cages. Clinical outcomes and flexion/extension ROM correlated with surgical technical accuracy of CHARITE artificial disc placement. In the majority of cases, placement of the CHARITE artificial disc was ideal.


  • The Indications for Interbody Fusion Cages in the Treatment of Spondylolisthesis

    by Paul C. McAfee, John G. DeVine, Christopher D. Chaput, Brad G. Prybis, Ira L. Fedder, Bryan W. Msc Cunningham, Dennis J. Bs Farrell, Samuel J. Hess, Franco E. Vigna

    Study Design. This study retrospectively examines outcomes of unilateral transforaminal lumbar interbody fusion (TLIF) with posterior fixation using anterior carbon fiber cages and 360° fusion in spondylolisthesis. Objectives. The goals were to examine the outcomes and perioperative complications of using anterior column support in the treatment of various types of spondylolisthesis. Summary of Background Data. In 2000, Brantigan et al reported the Brantigan interbody fusion cage used as a posterior lumbar interbody fusion in the US IDE clinical trial. This is the largest series to date of TLIF cages specifically used in the treatment of spondylolisthesis. Methods. A comprehensive long-term follow-up study was conducted to evaluate the fusion success and morbidity following implantation with an anterior column support and posterior pedicle screw fixation. The 120 patients with spondylolisthesis were comprised by 11 cases, dysplastic; 58 cases, degenerative; and 51 cases, isthmic-acquired spondylolisthesis. Anterior column support was either a rectangular carbon fiber/PEEK device or a cylindrical carbon fiber/PEEK device. Twenty-eight cases (23%) were revisions. Results. There were no pseudarthrosis, instrumentation failures, or significant subsidence at the TLIF level. The disc space height and foraminal height were restored as part of the surgical procedure. Disc height, as measured from the posterior edge of the superior vertebral body, increased from a mean of 5.6 mm before surgery to a mean of 9.3 mm after surgery. Although reduction of the slip was not the primary goal during the surgical procedure for the 120 cases with spondylolisthesis (isthmic-acquired = 51, degenerative = 58, and dysplastic = 11), the 23% slip reduction achieved at surgery was maintained at follow-up. Mean operative time was 143 ± 33 minutes (range, 70–255 minutes) for all cases. Mean blood loss was 724 ± 431 mL (range, 300–2,500 mL).There were seven incidental durotomies and three infections. One patient with Grade I degenerative spondylolisthesis required revision of the carbon fiber cage for posterior migration secondary to a traumatic event 3 months after surgery. Fusion success was 98% using the criteriaof Lenke for the posterior fusion and Brantigan and Steffee for the TLIF graft incorporation. Conclusions. Interbody cages in spondylolisthesis are useful to increase neuroforaminal height, to facilitate reduction, and to improve the chances of achieving a successful 360° fusion.


  • Experimental Design of Total Disk Replacement—Experience with a Prospective Randomized Study of the SB Charitè

    by Paul C. McAfee, Ira L. Fedder, Samer Saiedy, Erin M. Shucosky, Bryan W. Cunningham

    Prospective randomized clinical trial. To determine if a prospective randomized study of patients with symptomatic degenerative disc disease treated with disc arthroplasty could be safely completed. Sixty patients with one-level discogenic pain confirmed by plain radiography, magnetic resonance imaging, and provocative discography for degenerative disc disease were randomized comparing 1/3 BAK anterior interbody fusion and 2/3 anterior SB Charitè artificial disc replacement. The mean age was 40.3 years (range 21–56 years). Nineteen cases were at L4–L5 and 41 cases were at L5–S1. Nineteen cases had BAK anterior interbody fusion and 41 cases were randomized as SB Charitè disc replacement. The length of surgery was mean 88.4 minutes (range 54–137 minutes) for both groups. The estimated blood loss was mean 289.5 cc (range 50–1800 cc). The length of hospital stay was a mean of 3.03 days (range 2 to 6 days). Oswestry Disability Index for the BAK control group was 45.9 ± 10.4 before surgery and 23.5 ± 17.2 at follow-up (P < 0.001). The corresponding ODI scores for the SB Charitè disc were 50.0 ± 14.3 before surgery and 25.0 ± 20.1 at a mean of 2 years’ follow-up (P < 0.001). This is the first study that shows improvement of functional outcome measures in a prospective randomized design treating primarily mechanical back pain and achieving comparable successful results to lumbar spinal stenosis decompression.


  • Cervical Disc Replacement—Porous Coated Motion Prosthesis

    by Paul C. McAfee, Bryan Cunningham, Anton Dmitriev, Niabin Hu, Seok Woo Kim, Andy Cappuccino, Luiz Pimenta

    Benchtop cadaveric biomechanical comparative testing and caprine animal model in vivo implantation. To evaluate the role of the posterior longitudinal ligament in cervical arthroplasty and to understand the relative contribution of this ligament in nonfusion applications. Rauschning refers to the posterior longitudinal ligament as "The Kleenex Ligament" due to its apparent anatomic insignificance. White and Panjabi found the posterior longitudinal ligament ranked only fourth in importance in tensile load-to-failure biomechanical testing. In the postoperative situation following anterior cervical diskectomy fusion, posterior longitudinal ligament integrity is overlooked by physicians because the entire disc space usually fuses into a homogeneous block of bone. This biomechanical study was undertaken to determine the relative importance of the posterior longitudinal ligament following two different degrees of anterior decompression, anterior disc replacement, and anterior arthrodesis procedures. A total of seven fresh frozen human cadaveric cervical spines (C3-C7) (mean age 68 +/- 19 years) were used for biomechanical testing. Each vertebra was equipped with three non-colinear light emitting diodes designed for detection by an optoelectronic motion measurement system (3020 Optotract System). To determine the multidirectional flexibility, six pure moments (flexion, extension, right + left lateral bending, right + left axial rotation) and axial compression were applied using a servohydraulic 858 Bionix testing device configured with a six-degree-of-freedom spine simulator. Range of motion was defined as the peak displacement from the initial neutral position to the maximum load, whereas the neutral zone represents the motion from the initial neutral position to the unloaded position at the beginning of the third cycle. Seven groups of (N = 7 each) constructs at C5-C6 were: 1) intact "native" C5-C6 level; 2) anterior diskectomy (posterior longitudinal ligament intact); 3) a Low Profile Porous Coated Motion cervical disc replacement; 4) posterior longitudinal ligament resected; 5) Porous Coated Motion cervical disc replacement fixed with anterior flanges and screws; 6) tricortical structural allograft; and 7) an anterior cervical translational plate + allograft. The caprine model was evaluated for suitability as an animal model with 12 goats undergoing C3-C4 anterior cervical Porous Coated Motion disc replacement. Group 2 (anterior diskectomy alone) was significantly more stable than Group 4 (anterior diskectomy + posterior longitudinal ligament resection) in flexion-extension, 18.7 +/- 4.76 degrees versus 24.8 +/- 4.42 degrees (P < 0.05) and in lateral bending, 5.9 +/- 1.79 degrees versus 10.7 +/- 2.8 degrees (P < 0.05). The comparison for the two conditions for axial rotation, 10.4 +/- 13.9 degrees versus 13.9 +/- 2.7 degrees, and axial compression, 1.19 +/-.98 degrees versus 1.52 +/- 1.14 degrees, showed the same trend. Twelve goats undergoing porous coated motion cervical disc replacement had no evidence of prosthesis loosening, neurologic complications, or experienced inflammatory reactions from particulate wear debris after 6 months of implantation. This study confirms the pivotal role of the posterior longitudinal ligament in postsurgical stability of the cervical spine following anterior diskectomy. This is because the lateral anulus, uncovertebral ligaments, and lateral capsular ligaments are stretched and plastically deformed in the surgical distraction process of restoring the disc space height following anterior surgical decompression. There should be a separate determination of the range of motion of cervical disc replacements depending of the integrity and the amount of the posterior longitudinal ligament that has been resected. There are two basic types of total knee replacements, posterior cruciate ligament-preserving and posterior cruciate ligament-sacrificing designs. In the cervical spine, an analogous situation exists biomechanically depending on whether the posterior longitudinal ligament needs to be removed in its entirety as part of the spinal cord decompression part of the procedure--it may be helpful to conceptually differentiate between posterior longitudinal ligament-preserving and posterior longitudinal ligament-sacrificing total cervical disc replacements.


  • Clinical Summary Statement

    by Paul C. McAfee, David W. Polly, Bryan Cunningham, Bob Gaines, Nadim Hallab, John Lubicky, Larry Lenke, Keith Bridwell


  • Classification of Heterotopic Ossification (HO) in Artificial Disk Replacement

    by Paul C. McAfee, Bryan W. Cunningham, John Devine, Eric Williams, Janet Yu-Yahiro

    There is currently no structured classification system to quantitate heterotopic bone formation after artificial disk replacement procedures. The purpose of this work was to develop a method of classifying heterotopic bone formation that is reliable between investigators with different levels of training and easy to remember with only five gradations of severity. One hundred one radiographs of clinical patients and 17 microradiographs from nonhuman primates having undergone various types of disk replacement were classified by seven independent reviewers. The κ statistics were calculated for interobserver variation between the seven participants with various levels of spinal training and the intraobserver error based on two assessments made at least 2 months apart. The interobserver reliability correlation coefficient for seven raters calculated using the intraclass κ correlation coefficient and the Kish ρ was r = 0.9683 (P < 0.0001). The intraobserver reliability based on readings at two time intervals at a minimum of 2 months apart was r = 0.8949 (P = 0.01). This classification of heterotopic ossification, periannular calcification, and ectopic bone formation associated with total disk arthroplasty proved to be highly reliable and reproducible.


  • SB Charité Disc Replacement

    by Paul C. McAfee, Ira L. Fedder, Samer Saiedy, Erin M. Shucosky, Bryan W. Cunningham

    Sixty patients with one-level discogenic pain confirmed by plain radiography, magnetic resonance imaging, and provocative discography for degenerative disc disease were randomized: one-third BAK anterior interbody fusion and two-thirds anterior SB Charité artificial disc replacement. The mean age was 40.3 years (range 21–56 years). Nineteen cases were at L4–L5 and 41 cases were at L5–S1. Nineteen cases had BAK anterior interbody fusion and 41 cases were randomized as SB Charité disc replacement. The length of surgery was mean 88.4 minutes (range 54–137 minutes) for both groups. The estimated blood loss was mean 289.5 mL (range 50–1800 mL). The length of hospital stay was a mean of 3.03 days (range 2–6 days). Oswestry Disability Index scores for the SB Charité disc (aggregate study group) were 50.0 ± 14.3 preoperatively and 25.0 ± 20.1 at 1–3 years' follow-up (P < 0.001). This is the first study that shows improvement of functional outcome measures in a prospective randomized design with disc arthroplasty treating primarily mechanical back pain and achieving comparable successful results to lumbar fusion—interbody fusion cage and BMP or interbody autograft and pedicle screw instrumentation.