ACAndrea Nóbrega Cavalcanti

Andrea Nóbrega Cavalcanti

*This is an algorithmically generated author record based on publicly available information.

Andrea Nóbrega Cavalcanti has a total of 167 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Interferência do aparelho fotopolimerizador e envelhecimento térmico na aparência de restaurações adesivas

    by Bianca Franco Públio Pereira Fernandes, Juliana Souza Carvalho, Lívia Vitória, Paula Mathias, Andrea Cavalcanti

    Ntrodução: Restaurações em resina composta (RC) reproduzem propriedades ópticas de dentes naturais, porém, podem sofrer alterações em sua aparência em função de características relacionadas ao material. Objetivo: avaliar a interferência da cor do sistema adesivo (SA) e do tipo de aparelho fotopolimerizador na coloração final de restaurações estéticas. Metodologia: 80 fragmentos de esmalte bovino previamente clareados, foi distribuído em 4 grupos: G1) SA com fotoiniciador APS + RC translúcida neutra; G2) SA com fotoiniciador APS + RC de esmalte B1; G3) SE com fotoiniciador canforoquinona + RC translúcida neutra; G4) SE com fotoiniciador canforoquinona + RC de esmalte B1. Cada grupo foi subdividido de acordo com o fotoativador utilizado (LED do tipo monowave ou polywave). As amostras receberam envelhecimento térmico e em seguida foi realizada avaliação da cor da luminosidade e Delta E, em três momentos: antes da restauração (Delta E1), após a restauração (Delta E2) e após o envelhecimento térmico (Delta E3). Foi realizada análise estatística (Anova com Medidas Repetidas no Tempo/Tukey, alfa=5%). Resultados: Após o envelhecimento, a luminosidade do G4 foi estatisticamente superior à do G1 e G3. O envelhecimento térmico elevou a luminosidade na maior parte das situações testadas. A variação entre Delta E1 e Delta E2 indicou diferenças entre os grupos polimerizados pelo polywave, com valores significativamente menores para o G2, comparado ao G1. Conclusão: a luminosidade e o Delta E das amostras não parecem influenciadas pela cor do SA. A presença de cor na RC parece estar diretamente relacionada com a luminosidade e Delta E da restauração.

  • Open Access

    Bond strength in class V cavities: an in vitro study on beveling, universal adhesive strategy, and composite type

    by Felipe José Ribeiro de Melo, Viviane Rocha, Vivian Leite Martins, Marcos Vinícius Salvador, Adriano Fonseca Lima, Andrea Nóbrega Cavalcanti

    Cervical Class V lesions present restorative challenges due to their multifactorial etiology and complex bonding substrates. Objectives: This study evaluated the influence of marginal bevel, bonding using a universal adhesive (etch-and-rinse or self-etch), and the resin composite type (conventional or bulk-fill) on the bond strength of simulated Class V cavities. Methodology: A total of 80 dental fragments (7mm×7 mm×2 mm) were obtained from bovine incisors. Cylindrical cavities with enamel margins and internal dentin walls were prepared centrally in each specimen. Samples were randomly assigned to groups based on three factors: presence or absence of bevel, bonding strategy (etch-and-rinse or self-etch), and resin composite type (conventional or bulk-fill). Groups with bevel received a 1 mm enamel bevel along the preparation margins using a conical diamond bur. Adhesive and restorative procedures were performed following the manufacturer’s recommendations. Bond strength was assessed using a push-out test on a universal testing machine. Data were analyzed using three-way ANOVA and Tukey’s post-hoc test (α=5%). Results: Presence of a marginal bevel did not significantly influence bond strength. The etch-and-rinse bonding strategy resulted in significantly higher bond strength than the self-etch approach, and bulk-fill composites presented superior performance compared with conventional composites. Conclusions: Combining a universal adhesive applied with the etch-and-rinse strategy and a bulk-fill composite proved to be an effective approach for enhancing bond strength with enamel and dentin substrates. Beveling of enamel margins did not improve the bond strength of Class V restorations, suggesting that this procedure may be unnecessary when margins are in enamel. Avoiding beveling in such situations contributes to preserve sound tooth structure and supports a more conservative restorative approach.

  • Open Access

    Color stability of an artificially aged nanofilled composite resin post-cured with different techniques

    by Lais Sampaio Souza, Tais Rocha Donato, Gabriela Alves Cerqueira, Andrea Nobrega Cavalcanti, Paula Mathias

    Background. Post-cured composite resins exhibit improvements in physical and mechanical properties due to additional polymerization conversion. However, the post-curing techniques might influence the color stability of composite resin materials. Thus, this study evaluated the color stability of a nanofilled composite resin (Filtek Z350 XT - 3M ESPE) subjected to different post-curing techniques. Methods. Sixty samples (color A2) were randomly allocated to six experimental groups (n=10): G1: photoactivation (P) (control); G2: P + microwave oven with distilled water; G3: P + microwave oven without distilled water; G4: P + conventional oven; G5: P + dry-heat sterilizer; G6: P + steam autoclave. All the groups were stored in distilled water for 60 days and immersed daily in 5 mL of a coffee solution for 3 minutes. The color readings (CIEL*a*b* system) were performed at two different time intervals, initially and after 60 days, in a reflectance spectrophotometer (UV-2600; Shimadzu). The colorimetric readings were performed using the Color Analysis software (CIEL*a*b* system). Results. Group G6 exhibited significantly low values of total color change (ΔE=13.16). The control (ΔE=15.32) and G5 (ΔE=15.49) groups exhibited intermediate values, with no difference between them. In turn, the groups in which the resin was heated in a microwave (G2 ΔE=18.55 and G3 ΔE=19.45) exhibited the most significant color changes (one-way ANOVA and Tukey test, P≤0.05). Conclusion. Steam autoclave post-polymerization increased the color stability of the nanofilled resin subjected to artificial aging and coffee immersion.


  • Open Access

    In vitro study of marginal, internal and proximal adaptation of implant-supported single-crown CAD/CAM restorations

    by Kamila Aguiar Figueiredo Alves, Janaina Emanuela Damasceno, Viviane Maia Barreto de Oliveira, Luiz Gustavo Cavalcanti Bastos, Andrea Nóbrega Cavalcanti

    Aim: This study evaluated the precision of a CAD/CAM system by measuring marginal, internal and proximal fits in implantsupported single-crown restorations. Methods: Ten models of the upper arch were made in which implants replaced the upper left premolars. For fabrication of the zirconia infrastructures, titanium bases (TiBase) were coded and scanned using a scan body. A second digital impression was made for the fabrication of prostheses. Silicone impression material was used to determine the internal clearance between the TiBase and infrastructure and between the infrastructure and crown, whose thickness was measured at three points [P1 (cervical), P2 (middle) and P3 (occlusal)] with a stereoscopic microscope at 70x and 100x magnification. One-way ANOVA for repeated measures and the Student t-test were used for the analysis of internal and marginal adaptation. Proximal contacts were analyzed qualitatively. Results: There was no significant difference between the teeth evaluated (Student’s t-test; p>0.05) or between the corresponding points evaluated in either tooth (one-way ANOVA; p>0.05). Analysis of the internal clearance between the infrastructure and crown demonstrated that all points were significantly different compared to the reference standardized at 100 μm (Student’s t-test p<0.0001). There was no significant difference between P1 and P2, with the thickness at these two points being lower than that obtained at P3 (one-way ANOVA, p<0.05). The proximal contacts did not coincide with the quality defined by the device. Conclusion: The system tested was unable to produce implantsupported single-crown ceramic restorations with marginal, internal and proximal fits matching the digital workflow, with the inferior fits requiring adjustment prior to cementation.


  • Open Access

    Effect of the ceramic translucency on the long-term water sorption and solubility of resin cements

    by Ana Paula Menezes Vaz Queiroz, Mariana Menezes Vaz Queiroz, Saryta Argolo, Richard Mark Foxton, Paula Mathias, Andrea Nóbrega Cavalcanti

    Aim: The aim of this study was to evaluate the influence of the translucency of ceramic on water sorption and solubility of resin cements over time. Methods: Lithium disilicate ceramic slides (15x15x1 mm), A1 in color and with different translucencies (high-medium-low) were manufactured; and a glass slide with similar dimension was used as control. Under every slide, 15 specimens (8x0.5 mm) from each resin cement were prepared: light-cured (RelyX Veneer); conventional dual-cured (RelyX ARC); and self-adhesive dual-cured (Rely-X U200). The specimens were then sub-divided according to the period of evaluation (immediately, after 6 and 12 months of storage) (n=5). To evaluate the loss or gain of mass, the specimens were dried until a constant mass was reached. Subsequently, they were divided according to the respective period of storage at 37°C in distilled water and weighed immediately following removal from water. After each period, specimens underwent a new dehydration. Values from water sorption and solubility were calculated and statistically analyzed (Anova 3-way/Tukey test). Results: The lower translucency resulted in greater water sorption and solubility for all cements, regardless of the experimental period. The self-adhesive dual-cured cement showed higher water sorption under all experimental periods and had worse values after 1 year aging. Differences among solubility could only be detected after aging, and the light-cured material had higher values after 6 and 12 months. Conclusions: It could be concluded that the low degree of translucency can negatively influence the passage of light and interfere on the durability of the resin cement. The conventional dual-cured resinous agent seemed to be less affected by such condition.


  • Open Access

    Marginal adaptation of provisional crowns made of acrylic and bisacrylic resins using different impression materials

    by Camilla Lopes Cerqueira, Roniel Kappler, Andrea Araújo Nobrega Cavalcanti, Emilena Maria Castor Xisto Lima

    Aim: To evaluate the marginal adaptation of provisional crowns made of acrylic and bisacrylic resins using different impression materials. Methods: a metal die and a matrix applied through a direct technique were used to fabricate the specimens. The impression materials used as a matrix were divided into four groups: Irreversible hydrocolloid (IH), laboratory silicone (LS), condensation silicone (CS), and addition silicone (AS). After the impression procedures, each matrix was loaded with the provisional prosthetic materials, Alike, Duralay, Protemp 4, and Structur 3 (n = 12). Marginal discrepancy was evaluated using a stereomicroscope at ×45 magnification. The images obtained were transferred to the Corel Draw X7 program, and the distances from the cervical margins of the specimen to the reference lines at the metal die were measured vertically. The data were analyzed by using 2-way ANOVA followed by the Tukey test (α=.05). Results: the acrylic resins had higher values ​​of marginal discrepancy compared to the bisacrylic resins. A statistically significant difference was found between all impression materials, and the irreversible hydrocolloid presented higher values of discrepancy (303.28–613.31 μm), whereas addition silicone had the lowest (48.61–190.06 μm). Conclusions: the bisacrylic resins had a better marginal adaptation compared to the acrylic resins. The addition silicone promoted a better marginal adaptation of the provisional prosthetic materials tested, followed by condensation silicone, laboratory silicone, and irreversible hydrocolloid.


  • Open Access

    Can surface protection prevent damage in margins of composite resin restorations after simulated endogenous erosion?

    by Luana Mendonça Dias, Janaina Emanuela Damasceno, Patricia Akemi Nishitani Shibasaki, Max José Pimenta Lima, Roberto Paulo Correia de Araújo, Richard Mark Foxton, Andrea Nóbrega Cavalcanti

    Aim: The study investigated the effect of using surface protection agents in the adaptation of external and internal margins of restorations subjected to simulated erosion. Methods: Cavities with margins in dentin were prepared in bovine incisors (n=120). Adhesive restorations were placed using a three-step etch&rinse adhesive system and nanofilled composite resin. The specimens were divided into four groups, according to the surface protection: negative control, topical application of fluoride (TAF), resin sealant and resin-modified glass ionomer varnish (RMGI varnish). Afterwards, they were divided into three sub-groups, according to the exposure to a simulated solution of gastric acid (DES) (5% HCl, pH=2,2) and subsequent remineralization (RE): negative control, 9 and 18 cycles of DES-RE. The evaluation of the tooth-restoration interface was performed on the internal and frontal images with the aid of a stereoscopic microscope (15x), and the percentage of continuous margins without adhesive failures was quantified. Results: In the external margins, only those groups with surface protection using sealants (resin and glass-ionomer) did not exhibit a significant decrease in the percentage of continuous margins after the erosive challenges. After 18 cycles of DES-RE, the use of resin-modified glass ionomer varnish resulted in the highest percentage of continuous margins. Conclusion: It was concluded that physically covering the surfaces with a sealing agent preserved the marginal adaptation of composite resin restorations exposed to endogenous erosive challenges.

  • Open Access

    Light curing resin cements containing iodonium salts promote suitable apical bonding of posts to radicular dentin

    by Thatiana de Vicente Leite, Andrea Nóbrega Cavalcanti, Adriano Fonseca de Lima, Luciano de Souza Gonçalves, David Christopher Watts, Giselle Maria Marchi Baron, Luis Roberto Marcondes Martins

    The aim of this study was to analyze the efficiency of experimental light-curing resin cements (ERCs) with a ternary photo-initiator system containing diphenyliodonium hexafluorphosphate (DPI) and different amines on retention of glass-fiber posts to dentin (GFP). ERCs formulations: a 1:1 mass ratio of 2,2-bis[4-(2-hydroxy-3-methacryloxypropoxy)phenylpropane and triethyleneglycol dimethacrylate. Camphorquinone was used as initiator. Six experimental groups were established according to the amine used: [ethyl-4-(dimethylamino)benzoate-EDMAB or 2-(dimethylamino)ethyl methacrylate-DMAEMA] and the concentration of DPI (0, 0.5 mol%, 1 mol%). The resin cements Variolink II (dual- and light-cured versions) were used as commercial reference. Eighty recently extracted bovine incisors (n = 10) were selected for this study. The roots were prepared and the fiber posts were cemented with the resin cement specified for each experimental group. Specimens from coronal, middle, and apical thirds of the root were subjected to push-out bond strength test 24 hours after bonding. Data were subjected to split-plot ANOVA and the Tukey test (p = 0.05). ERCs containing DPI showed statistically significant higher bond strengths compared with ERCs without DPI. ERCs containing DPI were statistically similar to VARIOLINK II – dual-cured and superior to VARIOLINK II – light-cured (except for EDMAB – 1DPI in the medium third and DMAEMA – 1DPI in the coronal third). Different amines did not influence post retention. The apical root region showed the lowest bond strength for the groups EDAB-0DPI, DMAEMA-0DPI and VARIOLINK II light-cured. Light-cured ERCs containing DPI were efficient for GFP retention to radicular dentin, with similar behaviour to that of dual-curing commercial resin cement.


  • Open Access

    Effect of surface protection on the permeability of eroded dentin

    by Vivian Leite Martins, Rodrigo Vitoria Da Costa Ramos, Max José Pimenta Lima, Roberto Paulo Correia De Araújo, Andrea Nóbrega Cavalcanti

    Eroded dentin might present the opening of dentinal tubules, increasing permeability, and consequently dentinal hypersensitivity. This study evaluated the permeability of dentin surfaces exposed to different levels of erosion and methods of surface protection. Dentine samples (3 mm × 3 mm × 1 mm) were prepared from bovine incisors (n = 90) and divided into three groups according to the method of controlling erosive challenge: Negative control, topical fluoride application, and glass ionomer sealant. Subsequently, they were randomly divided into three subgroups according to the exposure of simulated gastric acid solution (Demineralization – DES) (5% HCl, pH = 2.2), and remineralization (RE); negative control, 9 and 18 cycles DES-RE. The dentin permeability was measured by assessing the hydraulic conductance (μl/min.cmH2O.cm2). Statistical analysis was performed by two-way ANOVA and Tukey's test. Greater permeability was observed after 18 erosive cycles, followed by exposure to 9 cycles and negative control (P < 0.0001). The application of glass ionomer sealant resulted in a major reduction of the hydraulic conductivity, regardless of the erosive challenge. Control groups and topical fluoride application showed similar results. In conclusion, the severity of erosive challenge contributed to the increase of dentin permeability. Besides, the glass ionomer sealant was the only protection agent that promoted significant effects in dentin permeability.


  • Open Access

    Effect of air-polishing on properties of nanocomposite submitted to coffee, red wine and cigarette smoke

    by Paula Mathias, Thayz Mota de Souza Cunha, Isadora Almeida Rios Rocha, Lívia Andrade Vitória, Caroline Mathias, Andrea Nóbrega Cavalcanti

    AIM: The aim of this study was to evaluate the surface roughness and the color stability of nanocomposite exposed to the sodium bicarbonate air-polishing (SBAP) followed by red wine, coffee and cigarette smoke exposure. MATERIALS AND METHODS: 64 nanocomposite specimens were prepared and allocated in 8 groups: G1 (SBAP + distilled water), G2 (SBAP + coffee), G3 (SBAP + red wine), G4 (SBAP + cigarette smoke), G5 (distilled water), G6 (coffee), G7 (red wine) and G8 (cigarette smoke). The surface roughness was evaluated in three periods: before and after SBAP and after exposuring to agents tested. The color was evaluated according to CIEL*a*b* parameters using reflection spectrophotometer in two moments: initial and 30 days after the exposure to staining agents. Data were subjected to three-way repeated measures ANOVA and Tukey’s test (5%). RESULTS: The results showed a higher surface roughness of the nanocomposite submitted only to the SBAP and those exposed to the SBAP followed by exposure to the coffee or wine solution. The previous application of SBAP followed by cigarette smoke exposure did not increase the roughness of nanocomposite. The SBAP procedure just increased the staining for cigarette smoke group. CONCLUSION: The SBAP increases resin surface roughness, which worsens when there is exposure to coffee and red wine solution. In addition, SBAP may also provide increased staining of nanocomposites exposed to cigarette smoke.