MWMin Wang

Min Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Min Wang has a total of 94 co-authors. Here are the top co-authors by number of shared publications:

  • Jiaqiang Zhou

    Department of Endocrinology School of Medicine, Sir Run Run Shaw Hospital, Zhejiang University Hangzhou Zhejiang China

    5 shared publications
  • Yang Cao

    Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science Zhejiang University Hangzhou Zhejiang China

    5 shared publications
  • Dingyi Lin

    Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science Zhejiang University Hangzhou Zhejiang China

    2 shared publications
  • Dingyi Lin

    Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science Zhejiang University Hangzhou China

    2 shared publications
  • Ed Xuekui Wu

    The University of Hong Kong

    2 shared publications
  • Feng Chen

    Department of Radiology, The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou China

    2 shared publications

Latest Publications

  • Noise‐Level Adaptive Diffusion Priors for Zero‐Shot Low‐Field MRI Quality Enhancement

    by Jiacai Cai, Shoujin Huang, Zihao Wang, Shaojun Liu, Huaishui Yang, Min Wang, Lingfang Xiao, Zhuangzhuang Miao, Jiangbin Zhang, Yilong Liu, et al.

    Low‐field MRI (LF‐MRI) improves imaging accessibility, but its practical utility is often limited by reduced signal‐to‐noise ratio, weaker tissue contrast, and variable image quality. These challenges are further compounded by the limited availability of low‐field training data across scanners and the fact that raw k‐space data are not always accessible in research and clinical workflows. In this study, we adapted a high‐field‐trained diffusion model for LF‐MRI quality enhancement without low‐field retraining or fine‐tuning. During inference, the pretrained diffusion prior was combined with noise‐level adaptive measurement guidance to suppress low‐field noise while maintaining consistency with measurement‐supported anatomical structures. With phase augmentation, this framework was further extended to magnitude‐only DICOM‐exported inputs when measured phase information was unavailable. The method was evaluated on 10 locally recruited healthy volunteers scanned at 0.05, 0.3, and 3 T, a public 0.064‐T healthy‐subject dataset with 10 paired cases, and patient cases acquired at 0.05 and 0.35 T. Compared with raw LF input and representative baselines including BM3D, MiDiffusion, and NAFNet, the proposed method (Nila) improved visual image quality, noise suppression, and tissue contrast, while preserving lesion‐region appearance in patient cases. On the 0.3 and 0.064 T datasets with coregistered 3‐T references, Nila achieved the best LPIPS and the highest or tied‐highest NMI across contrasts, indicating improved similarity to the high‐field reference. Multisample posterior inference further produced uncertainty maps that provide an explainable‐AI view of spatial output variability, with elevated variance mainly localized to tissue boundaries and ambiguous regions. These results suggest that high‐field diffusion priors can serve as practical and reusable tools for LF‐MRI enhancement across heterogeneous systems.

  • Associations Between Biochemical Risk Markers and MRI ‐Determined Ectopic Fat Distribution in Liver and Pancreas of Pediatric Obesity

    by Yan‐Ci Zhao, Yang Cao, Yan‐Hong Mi, Feng‐Yu Tian, Hong‐Xi Zhang, Jia‐Qiang Zhou, Hong Zhang, Jun‐Fen Fu, Feng Chen, Min Wang

    Background: Ectopic fat deposition in the liver and pancreas is closely linked to metabolic dysfunction, a key driver of the global burden of chronic disease. However, studies on intra‐organ distribution of ectopic fat in the pediatric obese population remain limited. Purpose: To assess MRI‐based spatial distribution patterns of hepatic and pancreatic fat using a fully automated nnU‐Net model and evaluate their association with biochemical risk markers. Study Type: Prospective. Subject: Eighty‐one pediatric patients (age: 12 [11, 13] years, 57 males) with overweight or obesity based on body mass index z ‐score. Field Strength/Sequence: 1.5 T, gradient‐echo modified‐DIXON T 1 W. Assessment: The spatial distribution of fat in liver and pancreas, the correlations between hepatic and pancreatic fat fraction (FF), and the association between the fat measures and biochemical risk markers were evaluated. Statistical Tests: Paired Wilcoxon test or t ‐test, repeated measure ANOVA or Friedman's test, Kruskal–Wallis test, Spearman correlation analysis. Significance was set at p < 0.05. Results: Hepatic FF was significantly higher in the right lobe (median, 16.22%) than in the left lobe (median, 10.43%), and increased with distance from the portal vein. The degree of hepatic fat heterogeneity increased with the amount of fat deposition (whole variance: Level 0: 4.10; Level 1: 11.53; Level 2: 28.94; Level 3: 31.21). Then, the FF and its variance in the pancreatic body and tail were significantly higher than those in the head. A weak but statistically significant correlation ( r range, 0.29–0.38) was observed between hepatic and pancreatic FF. Hepatic FF correlated with triglyceride and apolipoprotein B, but pancreatic fat showed no association ( p range, 0.096–0.994) with lipid profiles, HOMA‐IR, or HOMA‐β. Data Conclusion: Intra‐hepatic and intra‐pancreatic fat were heterogeneously distributed in pediatric obese population. Although fat accumulation in the liver and pancreas was weakly correlated, hepatic and pancreatic fat may arise from distinct metabolic disorders. Evidence Level: 2. Technical Efficacy: Stage 1.


  • In Vivo Measurement of Taurine With Optimized Double‐Quantum Filtering Magnetic Resonance Spectroscopy

    by Yufan Zhou, Chenting Ye, Jiaqiang Zhou, Yang Cao, Dingyi Lin, Yefeng Yao, Hong Zhang, Min Wang

    Purpose: To enhance the accuracy and reproducibility for in vivo taurine quantification using the double‐quantum filtering (DQF) technique. Methods: Simulations and phantom experiments were conducted at both 7 T and 3 T to determine the optimal parameter τ by calculating the taurine purity index among other neighboring metabolites. The frequency‐selective read‐pulse bandwidth and the dephasing/rephasing gradient moments were further adjusted to reduce residual water side band interference. Rat models of C6 gliomas were compared to normal brain for taurine level at 7 T. Metabolomics was conducted to validate the accuracy of taurine quantification. Human gray and white matter taurine differences were revealed at 3 T. Test–retest reliability was evaluated on humans. Results: Simulations and phantom experiments identified optimal τ for maximizing taurine signal purity as 102 ms at 7 T and 92 ms at 3 T. The best combinations of parameters for minimal water interference were determined at 3 T. Optimized DQF sequences yielded lower CRLBs. In rat brains, taurine concentration measured with optimized DQF sequences exhibited strong correlation with metabolomics, outperforming both conventional MRS and nonoptimized DQF sequences. Only the optimized method revealed significant taurine concentration differences between gray and white matter. Test–retest demonstrated good reproducibility in gray matter (ICC = 0.82) for the optimized method. Conclusion: The optimized DQF method enhances taurine detection accuracy and robustness in both animal and human studies and was for the first time applied in human brain taurine test at 3 T.

  • Open Access

    Downfield magnetic resonance signals serve as endogenous imaging biomarkers of nucleotide metabolism in glioma

    by Xinyi Zhu, Ke Zhou, Yang Cao, Jiaqiang Zhou, Yingchao Liu, Yibo Liu, Sheng Chen, Min Wang

    Gliomas, the most common primary brain tumors, exhibit profound metabolic alterations that can be non-invasively probed using magnetic resonance spectroscopy (MRS). Compared to upfield signals in traditional MRS, downfield signals exhibit complex composition with limited understanding of their metabolite origins. Correlating high-throughput metabolic profiles provided by untargeted metabolomics with MRS signals can help elucidate the origins of metabolites in MRS. In this study, upfield and downfield MRS spectra are obtained from control and glioma-bearing male Wistar rats, followed by correlation analysis with untargeted metabolomics from corresponding brain tissues. Here, we show that multiple downfield MRS peaks are significantly elevated in glioma rats and correlate with metabolomic features. Notably, downfield MRS demonstrate the capability of capturing adenosine triphosphate (ATP)-associated nucleotide metabolism. Furthermore, MRS signatures exhibit predictive potential for tumor growth parameters. This work establishes an integrated MRS-metabolomics framework, providing a basis for non-invasively monitoring dynamic metabolic reprogramming and predicting glioma progression.


  • Open Access

    Spatial characterization of intrahepatic fat deposition across steatotic liver disease subcategories: a multicenter study

    by Yan-Ci Zhao, Min Wang, Shuzhen Wu, Yuanyuan Bao, Zeyan Wu, Shengze Jin, Yang Cao, Yanyan Zhu, Junhan Pan, Huizhen Huang, et al.

    Intrahepatic fat accumulation presents spatial heterogeneity, potentially varying across steatotic liver disease (SLD) subcategories. Current whole-liver s


  • Robust simultaneous multislice MRI reconstruction using slice-wise learned generative diffusion priors

    by Shoujin Huang, Guanxiong Luo, Yunlin Zhao, Yilong Liu, Yuwan Wang, Kexin Yang, Jingzhe Liu, Hua Guo, Min Wang, Lingyan Zhang, et al.


  • Lipid‐targeted echo‐planar spectroscopic imaging technique for in vivo lipid composition measurement

    by Dingyi Lin, Jiaqiang Zhou, Xinyi Zhu, Yufan Zhou, Wenjing Zhang, Feng Chen, Mengye Lyu, Chunli Cai, Hong Zhang, Min Wang

    Purpose: Accurate in vivo assessment of lipid composition with high resolution and full abdominal coverage is essential for understanding lipid metabolism. This study aimed to develop and evaluate a novel lipid‐targeted imaging technique, chemical shift–selective adiabatic refocusing spin‐echo echo‐planar spectroscopic imaging (EPSI) (Csar‐EPSI), for rapid, precise, and reliable lipid composition measurements.Methods: Csar‐EPSI was designed with adiabatic pulses to selectively refocus lipid signals, suppress water, minimize chemical‐shift displacement errors, and enable flexible voxel selection. Phantom and in vivo experiments were performed on a 7T Bruker MR system, comparing Csar‐EPSI with conventional spin‐echo EPSI (Con‐EPSI) and point‐resolved spectroscopy. Accuracy in lipid composition measurement was validated in phantoms, whereas test–retest reliability and sensitivity were assessed in the liver and subcutaneous white adipose tissue (WAT) of obese and healthy control mice.Results: Csar‐EPSI demonstrated higher time efficiency, improved water suppression, and reduced chemical‐shift displacement errors compared with traditional methods. It exhibited higher sensitivity for detecting low‐concentration lipid biomarkers, particularly polyunsaturation indices (PUI and PUIUFA), with lower test–retest variability and higher reliability. Csar‐EPSI effectively differentiated lipid profiles between obese and healthy control mice, revealing significant reductions in polyunsaturated lipids in the liver and WAT of obese mice. Additionally, significantly higher polyunsaturated lipid markers in the liver compared with WAT in both groups were identified.Conclusion: Csar‐EPSI enables rapid, precise, and reliable in vivo lipid composition assessment with enhanced sensitivity over conventional methods. This novel technique facilitates detailed studies of unsaturated lipid metabolism in the liver and other abdominal organs, providing valuable insights into disease pathology and metabolic pathways.

  • Open Access

    Altered dynamic functional connectivity in antagonistic state in first-episode, drug-naïve patients with major depressive disorder

    by Min Wang, Tao Chen, Zhongyi He, Lawrence Wing-Chi Chan, Qinger Guo, Shuyang Cai, Jingfeng Duan, Danbin Zhang, Xunda Wang, Yu Fang, et al.

    Major depressive disorder (MDD) is known to be characterized by disrupted brain functional network connectivity (FNC) patterns, while the dynamic change mode of different functional networks is unclear. This study aimed to characterize specific dynamic alterations pattern on intrinsic FNC in MDD by combining static FNC (sFNC) and dynamic FNC (dFNC). A total of 48 first-episode drug-naïve MDD and 48 matched healthy controls (HCs) were included in this study. The sFNC and dFNC were analyzed using complete time-series and sliding window approach, respectively. Both sFNC and dFNC differences between groups were analyzed and associations between disease severity and aberrant FNC were explored. MDD patients exhibited lower sFNC within and between sensory and motor networks than HC. Four dFNC states were identified, including a globally-weakly-connected state, a cognitive-control-dominated state, a globally-positively-connected state, and an antagonistic state. The antagonistic state was marked by strong positive connections within the sensorimotor domain and their anti-correlations with the executive-motor control domain. Notably, MDD patients exhibited significantly longer dwell time in the globally-weakly-connected state, at the cost of significantly shorter dwell time in the antagonistic state. Further, only the mean dwell time of this antagonistic state was significantly anticorrelated to disease severity measures. Our study highlights the altered dynamics of the antagonistic state as a fundamental aspect of disrupted FNC in early MDD.


  • Echo time optimization for in‐vivo measurement of unsaturated lipid resonances using J‐difference‐edited MRS

    by Dingyi Lin, Jiaqiang Zhou, Yang Cao, Ziyan Wang, Yi‐Cheng Hsu, Fenping Zheng, Hong Li, Shuiya Sun, Hong Ren, Liping Deng, et al.

    Purpose: Measuring lipid composition provides more information than just total lipid content. Hence, the non‐invasive measurement of unsaturated lipid protons with both high efficiency and precision is of pressing need. This study was to optimize echo time (TE) for the best resolving of J‐difference editing of unsaturated lipid resonances.Methods: The TE dependence of J‐difference‐edited (JDE) MRS was verified in the density‐matrix simulation, soybean oil phantom, in‐vivo experiments of white adipose tissue (WAT), and skeletal muscles using single‐voxel MEGA‐PRESS sequence at 3T. The peak SNRs and Cramér‐Rao lower bounds (CRLBs) acquired at the proposed TE of 45 ms and previously published TE of 70 ms were compared (eight pairs) in WAT, extramyocelluar lipids (EMCLs), and intramyocellular lipids (IMCLs). The lipid composition in skeletal muscles was compared between healthy males (n = 7) and females (n = 7).Results: The optimal TE was suggested as 45 ms. Compared to 70 ms, the mean signal gains at TE of 45 ms were 151% in WAT, 168% in EMCL, 204% in IMCL for allylic resonance, and 52% in EMCL for diallylic resonance. CRLBs were significantly reduced at TE of 45 ms in WAT, EMCL, IMCL for allylic resonance and in EMCL for diallylic resonance. With TE of 45 ms, significant gender differences were found in the lipid composition in EMCL pools, while no difference in IMCL pools.Conclusion: The JDE‐MRS protocol with TE of 45 ms allows improved quantification of unsaturated lipid resonances in vivo and future lipid metabolism investigations.


  • Multiparametric Magnetic Resonance Investigations on Acute and Long‐Term Kidney Injury

    by Bin Wang, Yongfang Wang, Jing Wang, Chentao Jin, Rui Zhou, Jinxia Guo, Hong Zhang, Min Wang

    Acute kidney injury (AKI) is a frequent complication of critical illness and carries a significant risk of short- and long-term mortality. The prediction of the progression of AKI to long-term injury has been difficult for renal disease treatment. Radiologists are keen for the early detection of transition from AKI to long-term kidney injury, which would help in the preventive measures. The lack of established methods for early detection of long-term kidney injury underscores the pressing needs of advanced imaging technology that reveals microscopic tissue alterations during the progression of AKI. Fueled by recent advances in data acquisition and post-processing methods of magnetic resonance imaging (MRI), multiparametric MRI is showing great potential as a diagnostic tool for many kidney diseases. Multiparametric MRI studies offer a precious opportunity for real-time noninvasive monitoring of pathological development and progression of AKI to long-term injury. It provides insight into renal vasculature and function (arterial spin labeling, intravoxel incoherent motion), tissue oxygenation (blood oxygen level-dependent), tissue injury and fibrosis (diffusion tensor imaging, diffusion kurtosis imaging, T1 and T2 mapping, quantitative susceptibility mapping). The multiparametric MRI approach is highly promising but the longitudinal investigation on the transition of AKI to irreversible long-term impairment is largely ignored. Further optimization and implementation of renal MR methods in clinical practice will enhance our comprehension of not only AKI but chronic kidney diseases. Novel imaging biomarkers for microscopic renal tissue alterations could be discovered and benefit the preventative interventions. This review explores recent MRI applications on acute and long-term kidney injury while addressing lingering challenges, with emphasis on the potential value of the development of multiparametric MRI for renal imaging on clinical systems. Evidence Level1 Technical EfficacyStage 2