KPKornelis A. Poelstra

Kornelis A. Poelstra

*This is an algorithmically generated author record based on publicly available information.

Kornelis A. Poelstra has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    First experience with a novel image guidance technology for posterior pedicle screw fixation: A cadaveric study on 2D/3D registration-based spine surgery

    by Benno Bullert, Jula Gierse, Eric Mandelka, Holger Freischmidt, Kornelis Poelstra, Paul Alfred Gruetzner, Sven Yves Vetter

    Purpose: Minimally invasive pedicle screw insertion relies on imaging techniques due to limited anatomical visualization. A potential solution for intraoperative 3D guidance is using 2D/3D registration algorithms, which align intraoperative 2D X-rays with preoperatively acquired 3D datasets. This study aimed to evaluate the application of a novel 2D/3D image guidance software in posterior fixation with pedicle screws regarding accuracy, speed, and radiation exposure in a realistic clinical setting. Methods: Four human cadavers were instrumented with a total of 80 pedicle screws (from T8 to L5) by eight surgeons using 2D/3D image guidance. The surgeons, with varying levels of experience in spine surgery and navigation, utilized the software for the first time. Before the procedures, they underwent a structured one-hour training session. Accuracy, time parameters, and radiation exposure during pedicle screw insertion were assessed. Results: All K-wires were inserted correctly, demonstrating precise wire placement, regardless of the surgeons’ experience. For pedicle screw placement, the 2D/3D image guidance achieved high accuracy of 95.0%, with no superior or inferior perforations. The mean time for each pedicle screw placement was 7.62 ± 2.83 min, with an average radiation exposure of 1.24 µSv per pedicle screw for the surgeon. Conclusion: The use of 2D/3D image guidance in this study demonstrated high precision in the placement of K-wires and pedicle screws. Consequently, 2D/3D image guidance presents a promising tool for both experienced and inexperienced users, facilitating precise 3D guidance of pedicle screws with a standard 2D C-arm.


  • Open Access

    Generating a Synthetic Lumbar CT from a Standard MRI Protocol

    by Yehiel Shilo, Frank M. Phillips, Timothy F. Witham, Kornelis Poelstra, Lital Hodeda, Moshe Stavsky

    Background: Eliminating the need for a preoperative spine CT scan prior to spine surgery offers significant financial advantages, reduced radiation exposure, and a more streamlined workflow. This can be achieved by converting a standard-protocol MRI scan into a synthetic CT (sCT), which provides a precise representation of bone structures. The sCT is intended for use in the preoperative planning and navigation of spine surgeries, eliminating the need for an additional CT scan. Methods: The transformation is based on a neural network architecture that converts MRI data into high-resolution sCT images. Although the resolution of standard magnetic resonance imaging ranges from 3 to 5 mm, sCT achieves sub-millimeter accuracy (below 1 mm). In this study, we present the results of the generation of sCT and compare them with conventional CT scans of the same patients. Results: A comprehensive comparison was conducted using both 3D and 2D measurements on 500 different vertebrae. The 3D evaluation used 3D surface distance measurement to assess the full vertebrae and key anatomical elements. The 2D analysis focused on critical distances that define the vertebral body, pedicles, and spinous processes. All measurements were performed automatically and validated by orthopedic surgeons, ensuring clinical relevance. Conclusions: This study shows that converting a standard-protocol MRI scan into an sCT provides a precise representation of bone structures.


  • Unrecognized Provider Burden During Hospital EMR Introduction

    by Kornelis Poelstra, Lara Cooper

    Introduction: The introduction of—or the transition to—a new electronic health record system (EHR) places an unrecognized burden on health care providers in our ever-changing health care environment of increased mandates, increased overhead, and reduced reimbursement to practice medicine. Purpose: The purpose of this study was to track the non-reimbursed time investment required for 6 providers from an independent spine surgery practice after a hospital system independently decided to transition to a new EHR system. Results: Between the 6 providers of the practice, 266 hours of required classroom time, in-person training, and video and phone call teaching sessions had to be completed to become “proficient” so that clinical utilization of the system for in-patient care was certified by the hospital trainers and the EHR company. Conclusions: The burdens associated with the introduction of mandatory EHRs are putting tremendous pressure on providers from a time commitment perspective. This detracts from patient care during that time and deserves to be compensated for by the EHR companies that extract billions of dollars from both federal and private insurers’ health care budgets.

  • Reduction of Postoperative Spinal Implant Infection Using Gentamicin Microspheres

    by Alec C. Stall, Ed Becker, Steven C. Ludwig, Daniel Gelb, Kornelis A. Poelstra

    Study Design. Three noncontiguous spinal implant sites in 1 rabbit were challenged with Staphylococcus aureus and local antibiotic prophylaxis was given with gentamicin in controlled-release microspheres (poly(lactic-coglycolic-acid) [PLGA]). Postoperative biomaterial-centered infection on and around the titanium rods was assessed using standard bacterial quantification essays. Objective. To assess surgical site and biomaterial-centered infection reduction with controlled release gentamicin from microspheres against S. aureus. Summary of Background Data. A postoperative biomaterial-centered infection can be devastating after successful thoracolumbar spinal surgery and puts a high burden on patients, families, surgeons, and hospitals, endangering both our healthcare budget and our ability to perform challenging cases in patients with increasing numbers of comorbidities. Systemic antibiotics often do not reach “dead-space” hematomas where bacteria harbor after surgery, whereas local, controlled release gentamicin prophylaxis through PLGA microspheres showed favorable pharmacokinetics data to achieve local bactericidal concentrations for up to 7 days after surgery. Methods. A well published rabbit spinal implant model with systemic cephalosporin prophylaxis was challenged to create a baseline infection of ∼70% in control sites. We then challenged 3 noncontiguous titanium rods inside the laminectomy defect with 10e6 colony forming units S. aureus and randomly treated 2 sites with gentamicin PLGA microspheres and 1 site with PLGA carrier only (control). Standard quantification techniques were used to assess biomaterial centered and soft tissue bacterial growth after 7 days. Results. After establishing reliable infection rates in control sites, the therapeutic arm of the study was started. Surgical site infections were found in 75% of control sites, whereas gentamicin microspheres reduced the incidence down to 38% in the same rabbits. Biomaterial-centered infection was reduced from 58% to 23% only in all sites challenged with 10e6 S. aureus. Conclusion. Postoperative, biomaterial-centered infection was reduced at least 50% with intraoperative gentamicin microspheres in the face of systemic cephalosporin prophylaxis and high dose S. aureus in a laminectomy defect in rabbits. The data are statistically and clinically significant, and further animal testing is planned to confirm these results.


  • Techniques to Minimize Intraoperative Radiation Exposure

    by R. Bryan Butler, Kornelis A. Poelstra